ETC CXA20

CXA20 Series | 20W DC/DC
Isolated DC/DC converters
CXA20 SERIES
Single and dual output
4:1 input voltage range
No minimum load required
6A on 3.3V (48V) output at 50˚C in still air
Wide operating temperature with overtemperature protection
±10% output voltage trim
Overvoltage protection
Remote ON/OFF control
Approved to EN60950, UL1950, cUL1950
Complies with ETS 300 019-1-3/2-3
Complies with ETS 300 132-2 input voltage and current requirements
Complies with ETS 300 386-1
Pin compatible with NFC15 and NFC20 series
Fixed switching frequency
Basic insulation system (input to output)
The CXA20 is a new 20W addition to the
enhanced performance and reliability
CXA family of open-frame, isolated, DC/DC
through low component count and
converters. The five model series features a
conservative component deratings.
4:1 input voltage range of 18 to 75VDC,
The CXA20 offers remote on/off, as well as
making it suitable for a wide variety of
overvoltage, overtemperature and short
communications and distributed power
circuit protection features.
applications. With its 2.0 x 1.6 inch industry
With full international safety approval
standard footprint, the CXA20 provides an
including EN60950 and cUL1950, the
easy upgrade option for new and existing
CXA20 reduces system compliance costs
Artesyn customers seeking a high-
and time to market. It provides basic
performance, cost-effective power supply.
insulation from input to output and can
The CXA20 is available in output voltages of
operate in high ambient temperatures with
3.3V, 5V, 12V, ±5V and ±12V. The 3.3V
or without airflow.
version delivering up to 6A is fully rated to
20W. Typical efficiency for the CXA20 is 83
[ 2 YEAR WARRANTY ]
percent.
Designed using Artesyn’s custom control
chip, automated component placement and
planar magnetics, the CXA20 affords
1
DC/DC
SXA10 Series
| 10W
CXA20 Series
| 20W
DC/DC
Isolated DC/DC converters
Stresses in excess of the maximum ratings can cause permanent damage to the device. Operation of the device is not implied at these or any
other conditions in excess of those given in the specification. Exposure to absolute maximum ratings can adversely affect device reliability.
Absolute Maximum Ratings
Characteristic
Symbol
Min
Input voltage - continuous
Vin (cont)
Input voltage - peak/surge
or standard/level
Typ
Max
Units
Notes and Conditions
-0.3
80
VDC
Vin(+) - Vin(-)
Vin (peak)
-0.3
100
VDC
2s max. non repetitive
Input voltage remote pin
Vrem (peak)
-0.3
75
VDC
Peaks of any duration
Operating temp. - singles
Top
-40
+105
˚C
Operating temp. - duals
Top
-40
+105
˚C
Measured at thermal reference
point, see Note 1 and Fig. 8.1
Measured at thermal reference
point, see Note 1 and Fig. 8.2
Storage temperature
Tstorage
-55
+125
˚C
All specifications are at nominal input, full resistive load and 25˚C unless otherwise stated.
Input Characteristics
Characteristic
Symbol
Min
Typ
Max
Units
Input voltage - operating
Vin (oper)
18
-
75
VDC
Input current - no load
lin
18
22
mADC
Vin (min) - Vin (max), enabled
Input current - Quiescent
lin (off)
5
10
mADC
Converter disabled
Input voltage rise/fall time
dv/dt
5
V/ms
As per ETS300-132
Inrush current (i t or peak)
linrush
-
As
As per ETS300-132
-
dB
Frequency <1 kHz
2
A
Slow blow/anti-surge, HRC
recommended, 200 V rated
Notes and Conditions
2
Input ripple rejection
60
Input fuse
2
Notes and Conditions
Turn On/Off
Characteristic
Symbol
Min
Typ
Max
Units
Input voltage - turn on
Vin (on)
-
16.5
18
VDC
Input voltage - turn off
Vin (off)
14
15.5
18
VDC
Hysteresis
1
VDC
Turn on delay - enabled,
then power applied
Tdelay
(power)
-
10
20
msec
With the enable signal asserted,
this is the time from when the
input voltage reaches the
minimum specified operating
voltage until the output voltage
is within the total regulation
band
Turn on delay - power
applied, then enabled
Tdelay
(enable)
-
10
20
msec
Vin = Vin (nom), then enabled.
This is the time taken until the
output voltage is within the total
error band
Rise time
Trise
-
5
10
msec
From 10% to 90%; full resistive
load, no external capacitance
2
CXA20 Series | 20W DC/DC
Isolated DC/DC converters
Signal Electrical Interface
Characteristic - Signal Name Symbol
Min
Typ
Max
Units
Notes and Conditions
At remote/control ON/OFF pin
Control pin open circuit voltage Vih (oc)
3
5
6
V
See Notes 2 and 3
Iih = 0µA; open circuit voltage
High level input voltage
Vih
2
High level input current
Iih
Acceptable high level
leakage current
V
Converter guaranteed on
when control pin is
greater than Vih (min)
100
µA
Current flowing into control pin
when pin is pulled high
Iih (leakage)
-50
µA
Acceptable leakage current from
signal pin into the open collector
driver (neg = from converter)
Low level input voltage
ViI
1.2
V
Converter guaranteed off
when control pin is
less than Vil (max)
Low level input current
IiI
-150
µA
Vil = 0.4 V
Low level input current
Iil (max)
-200
µA
ViI = 0.0 V; maximum source
current from converter with
short circuit
Common Protection/Control
Characteristic
Symbol
Min
Typ
Max
Units
Notes and Conditions
Overtemperature shutdown
threshold (singles)
Tots
115
120
125
˚C
PCB temperature at PTC(s),
non-latching shutdown
protection
Overtemperature shutdown
- restart hysteresis
-
-
1
-
˚C
Remote sense compensation
NA
mV
There is no remote compensation
available on this device
Units
Notes and Conditions
Reliability and Service Life
Characteristic
Symbol
Min
Typ
Max
Mean time between failure
MTBF
400,000
Hours
MIL-HDBK-217F,
Vin = Vin (nom); Iout = Iout
(max); ambient 25˚C;
ground benign environment
Mean time between failure
MTBF
TBD
Hours
Demonstrated
Symbol
Min
Max
Units
Notes and Conditions
1500
VDC
Test duration 1s
Isolation
Characteristic
Typ
Input to output test voltage
Input to output capacitance
Input to output resistance
Input to output insulation
system
3
www.artesyn.com
1500
100
pF
MΩ
Basic
Measured with 500 VDC
SXA10 Series
| 10W
DC/DC
CXA20 Series
| 20W
DC/DC
Isolated DC/DC converters
Other Specifications
Characteristic
Symbol
Min
Typ
Max
Units
Notes and Conditions
Switching frequency
Fsw
360
400
440
kHz
Fixed frequency
Weight
-
26
-
g
Min
Typ
Max
Units
Notes and Conditions
-40
+60
˚C
Dependent on input voltage
See Notes 1, 5 and
Figures 1.1-1.5 and 8
m
ft
m
ft
Derate max. output
current by 20%
Derate max. output
current by 50%
Environmental Requirements
Characteristic
Symbol
Thermal performance
Altitude
3,000
9,864
10,000
32,821
Characteristic
Parameter
Reference
Test Level
Notes and Conditions
Air temperature
Low
High
Change
IEC 68-2-1
IEC 68-2-2
IEC 68-2-14
-40˚C
+60˚C (T3.4)
-40˚C to +60˚C
All characteristics and parameters
extracted from ETS 300 019
classes 3.1, 3.2, 3.3, 3.4 and 3.5
Relative humidity
Low
High
Condensation
IEC 68-2-56
IEC 68-2-30
10%
93%
90 to 100%
Damp heat, 4 days
Damp heat, 2 cycles, 25 to 35˚C
Vibration IEC class 3M5
Shocks IEC class 3M5
Freq. velocity
IEC 68-2-6
Freq. acceleration IEC 68-2-6
MIL-STD-202F
Acceleration
IEC 68-2-29
MIL-STD-202F
5-9Hz 5mm/s
9-200Hz 1g
Method 204 cond. A
10g
Method 213B cond. F
Referenced ETSI standards:
ETS 300 019: Environmental conditions and environmental tests for telecommunications equipment
ETS 300 019: Part 1-3 (1997) Classification of environmental conditions stationary use at weather protected locations
ETS 300 019: Part 2-3 (1997) Specification of environmental tests stationary use at weather protected locations
EMC
Electromagnetic Compatibility
Phenomenon
Port
Standard
Test level Criteria
Notes and conditions
ESD
Enclosure
EN61000-4-2
6kV cont
8kV air
8kV cont
15kV air
NP
NP
RP
RP
As per ETS 300 386-1 table 5
EFT
DC power
EN61000-4-4
EN61000-4-4
NP
LFS
NP
LFS
As per ETS 300 386-1 table 5
Signal
2kV
4kV
1kV
2kV
Radiated field
Enclosure
EN61000-4-3
10V/m
NP
As per ETS 300 386-1 table 5
Surges
Indoor signal
EN61000-4-5
500V
RP
As per ETS 300 386-1 table 5
Conducted
DC power
Signal
EN61000-4-6
EN61000-4-6
10V
10V
NP
NP
As per ETS 300 386-1 table 5
Input transients
DC power
Immunity:
4
As per ETS 300 386-1 table 5
ETS 300 132, ETR 283
CXA20 Series | 20W DC/DC
Isolated DC/DC converters
EMC
Electromagnetic Compatibility
Phenomenon
Port
Standard
Test level Criteria
Notes and conditions
DC power
EN55022
Level A
EN55022
Level B
EN55022
Level B
See recommended external filter
(See Application Note 107) for compliance.
Bandwidth 20 kHz to 30 MHz,
as per ETS 300 386-1
See recommended external filter (See
Application Note 107) for compliance.
Bandwidth 20 kHz to 30 MHz,
as per ETS 300 386-1
Bandwidth 150kHz to 30MHz,
as per ETS 300 386-1
EN55022
Level B
Emission:
Conducted
Signal
Radiated
(See Application Note 107)
Bandwidth 30 MHz to 1 GHz, as per
ETS 300 386-1, with Cu ground plane
Performance criteria:
NP: Normal Performance: EUT shall withstand applied test and operate within relevant limits as specified without damage.
RP: Reduced Performance: EUT shall withstand applied test. Reduced performance is permitted within specified limits, resumption to
normal performance shall occur at the cessation of the test.
LFS: Loss of Function (self recovery): EUT shall withstand applied test without damage, temporary loss of function permitted during test.
Unit will self recover to normal performance after test.
Referenced ETSI standards:
ETS 300 386-1 table 5 (1997): Public telecommunication network equipment, EMC requirements
ETS 300 132-2 (1996): Power supply interface at the input to telecommunication equipment: Part 2 operated by direct current (DC)
ETR 283 (1997): Transient voltages at interface A on telecommunications direct current (DC) power distributions
Safety Agency Approvals
Characteristic
UL/cUL 1950 File Number
VDE Reference Number
VDE License Number
E136005
10401-3336-0154/31HJK
DE1-8142 (CB Certificate Number)
TBA
Standards Compliance List
Standard
Category
EN60950
UL/cUL1950
VDE
3rd edition
EN60950 (VDE0805) : 1997 + A11
Material Ratings
Characteristic - Signal Name Notes and Conditions
Flammability rating
Material type
UL94V-0
FR4 PCB
Model Numbers
Model
Number
Input
Voltage
CXA20-48S3V3
CXA20-48S05
CXA20-48S12
CXA20-48D05
CXA20-48D12
5
www.artesyn.com
18-75
18-75
18-75
18-75
18-75
VDC
VDC
VDC
VDC
VDC
Output
Voltage
Overvoltage
Protection (6)
Output Current
(Max.)
Typical
Efficiency
3.3V
5V
12V
±5V
±12V
3.7V
6.67V
14.25V
6.67V
14.25V
6A
4A
1.66A
2A ea.
0.83A ea.
80%
83%
83%
84%
84%
SXA10 Series
| 10W
DC/DC
CXA20 Series
| 20W
DC/DC
Isolated DC/DC converters
CXA20-48S3V3 Model
Input Characteristics
Characteristic
Symbol
Input current - operating
Min
Typ
Max
Units
Notes and Conditions
Iin
0.52
0.53
ADC
Vin = Vin (nom); Iout = Iout
(max); Vo = Vo (nom)
Input current - maximum
Iin (max)
1.41
1.45
ADC
Vin = Vin (min); Iout = Iout
(max); Vo = nom
Reflected ripple current
Iin (ripple)
3
10
mA RMS
Iout = Iout (max), measured with
no external bypass capacitor
Reflected ripple current
Iin (ripple)
20
40
mA pk-pk Iout = Iout (max), measured with
no external bypass capacitor
Input capacitance - internal
filter (all models)
Cinput
1.5
µF
Internal to converter
(ceramic)
CXA20-48S3V3 Model
Electrical Characteristics - O/P
Characteristic
Symbol
Min
Typ
Max
Units
Notes and Conditions
Nominal set-point voltage
Vout (nom)
3.25
3.30
3.35
VDC
Vin = Vin (Nom);
Iout = Iout (nom); T = 25˚C
Total regulation band
Vout
3.16
-
3.43
VDC
For all line, static load and
temperature until end of life.
Line regulation
-
0.10
0.20
%
Iout = Iout (nom)
Vin (min) - Vin (max)
Load regulation
-
0.20
0.30
%
Vin = Vin (Nom)
Iout (min) - Iout (max)
0.02
±%/˚C
Vin = Vin (Nom)
Iout = Iout (nom)
6.00
ADC
Temperature regulation
Output current continuous
Iout
Output current - short circuit
Isc
5.00
6.00
A RMS
Output voltage - noise
Vp-p
Vrms
50
13
75
20
mV pk-pk Measurement bandwidth 20 MHz
mV RMS Measurement bandwidth 20 MHz
See Application Note 107 for
measurement set-up details
6
0.00
Continuous, unit auto recovers
from short, load resistance <20 mΩ
CXA20 Series | 20W DC/DC
Isolated DC/DC converters
CXA20-48S3V3 Model
Electrical Characteristics - O/P
Characteristic
Symbol
Load transient response peak deviation
Min
Typ
Max
Units
Notes and Conditions
Vdynamic
1.0
2.0
%
Peak deviation for 50% to 75%
step load, di/dt = 100 mA/µsec
Load transient response recovery
Trecovery
100
300
µsec
Settling time to within 1% of
output set point voltage for 50%
to 75% step load
External load capacitance
Cext
0
10,000
2,000
µF
µF
Vin = 18 to 36 VDC
Vin = 36 to 75 VDC
Characteristic
Symbol
Min
Max
Units
Notes and Conditions
Overvoltage clamp voltage
Vov
3.70
4.10
VDC
Non-latching.
Refer to Application Note 107
Overcurrent limit inception
Ioc
-
8
9
ADC
Vout = 90% of Vout (nom)
Output voltage trim range
10.0
10.0
11.0
11.0
15.0
15.0
%
%
Trim up
Trim down
Open sense voltage
NA
NA
NA
VDC
No sense pins on this device
Max
Units
Notes and Conditions
CXA20-48S3V3 Model
Protection and Control Features
Typ
CXA20-48S3V3 Model
Efficiency
Characteristic
Symbol
Min
Typ
Efficiency
η
79.0
80.0
%
Iout = 100% Iout (max),
Vin = 48 VDC
Efficiency
η
78.0
79.0
%
Iout = 50% Iout (max),
Vin = 48 VDC
7
www.artesyn.com
SXA10 Series
| 10W
DC/DC
CXA20 Series
| 20W
DC/DC
Isolated DC/DC converters
CXA20-48S05 Model
Input Characteristics
Characteristic
Symbol
Input current - operating
Min
Typ
Max
Units
Notes and Conditions
Iin
0.50
0.51
ADC
Vin = Vin (nom); Iout = Iout
(max); Vo = Vo (nom)
Input current - maximum
Iin (max)
1.31
1.40
ADC
Vin = Vin (min); Iout = Iout
(max); Vo = nom
Reflected ripple current
Iin (ripple)
3
10
mA RMS
Iout = Iout (max), measured with
no external bypass capacitor
Reflected ripple current
Iin (ripple)
20
40
mA pk-pk Iout = Iout (max), measured with
no external bypass capacitor
Input capacitance - internal
filter (all models)
Cinput
1.5
µF
Internal to converter
(ceramic)
CXA20-48S05 Model
Electrical Characteristics - O/P
Characteristic
Symbol
Min
Typ
Max
Units
Notes and Conditions
Nominal set-point voltage
Vout (nom)
4.925
5.00
5.075
VDC
Vin = Vin (Nom);
Iout = Iout (nom); T = 25˚C
Total regulation band
Vout
4.80
-
5.20
VDC
For all line, static load and
temperature until end of life
Line regulation
-
0.10
0.20
%
Iout = Iout (nom)
Vin (min) - Vin (max)
Load regulation
-
0.10
0.20
%
Vin = Vin (Nom)
Iout (min) - Iout (max)
Temperature regulation
-
-
0.02
±%/˚C
Vin = Vin (nom), Iout = Iout (nom)
4.00
ADC
5.00
A RMS
Output current continuous
Iout
Output current - short circuit
Isc
0
3.30
Continuous, unit auto recovers
from short, load resistance <20 mΩ
Output voltage - noise
8
Vp-p
60
75
mV pk-pk Measurement bandwidth 20 MHz
Vrms
9.5
20
mV RMS
Measurement bandwidth 20 MHz
See Application Note 107 for
measurement set-up details
CXA20 Series | 20W DC/DC
Isolated DC/DC converters
CXA20-48S05 Model
Electrical Characteristics - O/P
Characteristic
Symbol
Load transient response peak deviation
Min
Typ
Max
Units
Notes and Conditions
Vdynamic
0.5
2.0
%
Peak deviation for 50% to 75%
step load, di/dt = 100 mA/µsec
Load transient response recovery
Trecovery
100
300
µsec
Settling time to within 1% of
output set point voltage for 50%
to 75% step load
External load capacitance
Cext
0
10,000
2,000
µF
µF
Vin = 18 to 36 VDC
Vin = 36 to 75 VDC
Characteristic
Symbol
Min
Max
Units
Notes and Conditions
Overvoltage clamp voltage
Vov
6.67
7.67
VDC
Non-latching
Refer to Application Note 107
Overcurrent limit inception
Ioc
-
6.1
6.50
ADC
Vout = 90% of Vout (nom)
Output voltage trim range
10.0
10.0
11
11
13.0
13.0
%
%
Trim up
Trim down
Open sense voltage
NA
NA
NA
VDC
No sense pins on this device
Max
Units
Notes and Conditions
CXA20-48S05 Model
Protection and Control Features
Typ
CXA20-48S05 Model
Efficiency
Characteristic
Symbol
Min
Typ
Efficiency
η
82.0
83.0
%
Iout = 100% Iout (max),
Vin = 48 VDC
Efficiency
η
81.0
82.0
%
Iout = 50% Iout (max),
Vin = 48 VDC
9
www.artesyn.com
SXA10 Series
| 10W
DC/DC
CXA20 Series
| 20W
DC/DC
Isolated DC/DC converters
CXA20-48S12 Model
Input Characteristics
Characteristic
Symbol
Input current - operating
Min
Typ
Max
Units
Notes and Conditions
Iin
0.50
0.52
ADC
Vin = Vin (nom);
Iout = Iout (max); Vo = Vo (nom)
Input current - maximum
Iin (max)
1.30
1.40
ADC
Vin = Vin (min);
Iout = Iout (max);
Vo = nom
Reflected ripple current
Iin (ripple)
3
10
mA RMS
Iout = Iout (max), measured with
no external bypass capacitor
Reflected ripple current
Iin (ripple)
20
40
mA pk-pk Iout = Iout (max), measured with
no external bypass capacitor
Input capacitance - internal
filter (all models)
Cinput
1.5
µF
Internal to converter (ceramic)
CXA20-48S12 Model
Electrical Characteristics - O/P
Characteristic
Symbol
Min
Typ
Max
Units
Notes and Conditions
Nominal set-point voltage
Vout (nom.)
11.82
12.0
12.18
VDC
Vin = Vin (Nom);
Iout = Iout (nom); T = 25˚C
Total regulation band
Vout
11.52
-
12.48
VDC
For all line, static load and
temperature until end of life
Line regulation
-
0.10
0.20
%
Iout = Iout (nom)
Vin (min) - Vin (max)
Load regulation
-
0.10
0.20
%
Vin = Vin (Nom)
Iout (min) - Iout (max)
Temperature regulation
-
-
0.02
±%/˚C
Vin = Vin (nom), Iout = Iout (nom)
1.66
ADC
2.50
A RMS
Output current continuous
Iout
Output current - short circuit
Isc
0.00
2.00
Continuous, unit auto recovers
from short, load resistance <20 mΩ
Output voltage - noise
10
Vp-p
Vrms
60
11
100
20
mV pk-pk Measurement bandwidth 20 MHz
mV RMS Measurement bandwidth 20 MHz
See Application Note 107 for
measurement set-up details
CXA20 Series | 20W DC/DC
Isolated DC/DC converters
CXA20-48S12 Model
Electrical Characteristics - O/P
Characteristic
Symbol
Load transient response peak deviation
Min
Typ
Max
Units
Notes and Conditions
Vdynamic
0.5
2.0
%
Peak deviation for 50% to 75%
step load, di/dt = 100 mA/µsec
Load transient response recovery
Trecovery
100
300
µsec
Settling time to within 1% of
output set point voltage for 50%
to 75% step load
External load capacitance
Cext
0
1,000
220
µF
µF
Vin = 18 to 36 VDC
Vin = 36 to 75 VDC
Characteristic
Symbol
Min
Max
Units
Notes and Conditions
Overvoltage clamp voltage
Vov
14.25
15.75
VDC
Non-latching
Refer to Application Note 107
Overcurrent limit inception
Ioc
2.7
3.20
ADC
Vout = 90% of Vout (nom)
10
10
NA
11
11
NA
13
13
NA
%
%
VDC
Cannot trim up for Vin <20 V
Trim down
No sense pins on this device
Max
Units
Notes and Conditions
CXA20-48S12 Model
Protection and Control Features
Output voltage trim range
Open sense voltage
Typ
CXA20-48S12 Model
Efficiency
Characteristic
Symbol
Min
Typ
Efficiency
η
81.0
83.0
%
Iout = 100% Iout (max),
Vin = 48 VDC
Efficiency
η
79.0
81.0
%
Iout = 50% Iout (max),
Vin = 48 VDC
11
www.artesyn.com
SXA10 Series
| 10W
DC/DC
CXA20 Series
| 20W
DC/DC
Isolated DC/DC converters
CXA20-48D05 Model
Input Characteristics
Characteristic
Symbol
Input current - operating
Min
Typ
Max
Units
Notes and Conditions
Iin
0.50
0.51
ADC
Vin = Vin (nom);
Iout = Iout (max);
Vo = Vo (nom)
Input current - maximum
Iin (max)
1.30
1.40
ADC
Vin = Vin (min);
Iout = Iout (max);
Vo = nom
Reflected ripple current
Iin (ripple)
3
10
mA RMS
Iout = Iout (max), measured with
no external bypass capacitor
Reflected ripple current
Iin (ripple)
20
40
mA pk-pk Iout = Iout (max), measured with
no external bypass capacitor
Input capacitance - internal
filter (all models)
Cinput
1.5
µF
Internal to converter (ceramic)
CXA20-48D05 Model
Electrical Characteristics - O/P
Characteristic
Symbol
Min
Typ
Max
Units
Notes and Conditions
Nominal set-point voltage
Vout (1)
4.925
5.00
5.075
VDC
Vout (2)
4.925
5.00
5.075
VDC
Vin = Vin (Nom);
Iout = Iout (nom); T = 25˚C
Vin = Vin (Nom);
Iout = Iout (nom); T = 25˚C
Total regulation band
Vout (1)
Vout (2)
4.80
4.75
-
5.20
5.25
VDC
VDC
For all line, static load and
temperature until end of life.
Does not include cross
regulation
Line regulation
Vout (1)
-
0.10
0.20
%
Vout (2)
-
0.10
0.50
%
Iout = Iout (nom);
Vin (min) - Vin (max);
positive output
Iout = Iout (nom);
Vin (min) - Vin (max);
negative output
Vout (1)
-
0.10
0.20
%
Vout (2)
-
0.10
0.50
%
Vout (1)
-
0.10
0.20
%
Vout (2)
-
7.00
10.00
%
Iout (1) = 100%,
Iout (2) = 10% to 100% or
Iout (2) = 100%,
Iout (1) = 10% to 100%
Vin = Vin (nom)
0.02
±%/˚C
Vin = Vin (nom), Iout = Iout (nom)
2.00
ADC
Each output (See Note 7)
Load regulation
Cross regulation
Temperature regulation
Output current continuous
12
Iout
0
Vin = Vin (nom), positive output,
Iout (1) = Iout (2) = 0% to 100%
Vin = Vin (nom), negative output,
Iout (1) = Iout (2) = 10% to 100%
CXA20 Series | 20W DC/DC
Isolated DC/DC converters
CXA20-48D05 Model
Electrical Characteristics - O/P
Characteristic
Symbol
Output current - short circuit
Isc
Output voltage - noise
Vp-p
Vrms
Load transient response peak deviation
Min
Typ
Max
Units
Notes and Conditions
2.50
A RMS
Continuous, unit auto recovers
from short load resistance
<20 mΩ between Vout1 (+)
and Vout2 (-)
55
9
75
20
mV pk-pk Measurement bandwidth: 20 MHz
mV RMS Measurement bandwidth 20 MHz
See Application Note 107 for
measurement set-up details
Vdynamic
0.5
2.0
%
Peak deviation for 50% to 75%
Step load, di/dt = 100 mA/µsec
Load transient response recovery
Trecovery
100
300
µsec
Settling time to within 1% of
output set point voltage for
50% to 75% step load
External load capacitance
Cext
0
5,000
1,000
µF
µF
Vin = 18 to 36 VDC
Vin = 36 to 75 VDC
Characteristic
Symbol
Min
Max
Units
Notes and Conditions
Overvoltage clamp voltage
Vov
6.67
7.67
VDC
Non-latching, see Note 6
Refer to Application Note 107
Overcurrent limit inception
Ioc
2.9
3.50
ADC
Vout = 90% of Vout (nom),
Iout (1) = Iout (2)
CXA20-48D05 Model
Protection and Control Features
Typ
Output voltage trim range
10.0
10.0
11
11
13.0
13.0
%
%
Trim up
Trim down
Open sense voltage
NA
NA
NA
VDC
No sense pins on this device
Max
Units
Notes and Conditions
CXA20-48D05 Model
Efficiency
Characteristic
Symbol
Min
Typ
Efficiency
η
82
84
%
Iout = 100% Iout (max),
Vin = 48 VDC
Efficiency
η
80
82
%
Iout = 50% Iout (max),
Vin = 48 VDC
13
www.artesyn.com
SXA10 Series
| 10W
DC/DC
CXA20 Series
| 20W
DC/DC
Isolated DC/DC converters
CXA20-48D12 Model
Input Characteristics
Characteristic
Symbol
Input current - operating
Min
Typ
Max
Units
Notes and Conditions
Iin
0.50
0.51
ADC
Vin = Vin (nom); Iout = Iout
(max); Vo = Vo (nom)
Input current - maximum
Iin (max)
1.32
1.40
ADC
Vin = Vin (min); Iout = Iout
(max); Vo = nom
Reflected ripple current
Iin (ripple)
3
10
mA RMS
Iout = Iout (max), measured with
no external bypass capacitor
Reflected ripple current
Iin (ripple)
20
40
mA pk-pk Iout = Iout (max), measured with
no external bypass capacitor
Input capacitance - internal
filter (all models)
Cinput
1.5
µF
Internal to converter
(ceramic)
CXA20-48D12 Model
Electrical Characteristics - O/P
Characteristic
Symbol
Min
Typ
Max
Units
Notes and Conditions
Nominal set-point voltage
Vout (1)
11.82
12.0
12.18
VDC
Vout (2)
11.82
12.0
12.18
VDC
Vin = Vin (Nom);
Iout = Iout (nom); T = 25˚C
Vin = Vin (Nom);
Iout = Iout (nom); T = 25˚C
Total regulation band
Vout
11.52
-
12.48
VDC
For all line, static load and
temperature until end of life
Does not include cross
regulation
Line regulation
Vout (1)
-
0.10
0.20
%
Vout (2)
-
0.10
0.50
%
Iout = Iout (nom);
Vin (min) - Vin (max);
positive output
Iout = Iout (nom);
Vin (min) - Vin (max);
negative output
Vout (1)
-
0.10
0.20
%
Vout (2)
-
0.10
0.50
%
Vout (1)
-
0.10
0.20
%
Vout (2)
-
7.00
10.0
%
Iout (1) = 100%,
Iout (2) = 10% to 100% or
Iout (2) = 100%,
Iout (1) = 10% to 100%
Vin = Vin (nom)
0.02
±%/˚C
Vin = Vin (nom), Iout = Iout (nom)
0.83
ADC
Each output (See Note 7)
Load regulation
Cross regulation
Temperature regulation
Output current continuous
14
Iout
0
Vin = Vin (nom), positive output,
Iout (1) = Iout (2) = 0% to 100%
Vin = Vin (nom), negative output,
Iout (1) = Iout (2) = 10% to 100%
CXA20 Series | 20W DC/DC
Isolated DC/DC converters
CXA20-48D12 Model
Electrical Characteristics - O/P
Characteristic
Symbol
Output current - short circuit
Isc
Output voltage - noise
Vp-p
Vrms
Load transient response peak deviation
Min
Typ
Max
Units
Notes and Conditions
1.40
A RMS
Continuous, unit auto recovers
from short load resistance
<20 mΩ between Vout1 (+) and
Vout2 (-)
65
100
12
20
mV pk-pk Measurement bandwidth: 20 MHz
mV RMS Measurement bandwidth 20 MHz
See Application Note 107 for
measurement set-up details
Vdynamic
0.5
2.0
%
Peak deviation for 50% to 75%
step load, di/dt = 100 mA/µsec
Load transient response recovery
Trecovery
100
300
µsec
Settling time to within 1% of
output set point voltage for
50% to 75% step load
External load capacitance
Cext
0
500
100
µF
µF
Vin = 18 to 36 VDC
Vin = 36 to 75 VDC
Characteristic
Symbol
Min
Max
Units
Notes and Conditions
Overvoltage clamp voltage
Vov
14.25
15.75
VDC
Non-latching, see Note 6
See Application Note
Overcurrent limit inception
Ioc
1.4
1.60
ADC
Vout = 90% of Vout (nom),
Iout (1) = Iout (2)
10.0
11
13.0
%
10.0
11
13.0
%
Trim up, cannot trim up for
Vin <20V
Trim down
NA
NA
NA
VDC
No sense pins on this device
Max
Units
Notes and Conditions
CXA20-48D12 Model
Protection and Control Features
Output voltage trim range
Open sense voltage
Typ
CXA20-48D12 Model
Efficiency
Characteristic
Symbol
Min
Typ
Efficiency
η
82
84
%
Iout = 100% Iout (max),
Vin = 48 VDC
Efficiency
η
80
82
%
Iout = 50% Iout (max),
Vin = 48 VDC
15
www.artesyn.com
SXA10 Series
| 10W
DC/DC
CXA20 Series
| 20W
DC/DC
Isolated DC/DC converters
Vin > 60
Vin < 60
100%
Rated Output Current (%)
Rated Output Current (%)
100%
80%
75%
60%
40%
20%
0%
80%
60%
50%
40%
20%
0%
-40˚C
-20˚C
0˚C
20˚C
40˚C
60˚C
80˚C
100˚C
-40˚C
-20˚C
0˚C
20˚C
40˚C
60˚C
80˚C
100˚C
Ambient Temperature (˚C)
Ambient Temperature (˚C)
Figure 1.1: Derating Curve Output Current vs Temperature S3V3
Natural Convection (<0.1m/s airflow)
Figure 1.2: Derating Curve Output Current vs Temperature S05
Natural Convection (<0.1m/s airflow)
Vin > 60
36 < Vin < 60
Vin < 36
Vin > 60
Vin < 60
100%
100%
Rated Output Current (%)
Rated Output Current (%)
60˚
80%
60%
40%
20%
-20˚C
0˚C
20˚C
40˚C
60˚C
80˚C
100˚C
Figure 1.3: Derating Curve Output Current vs Temperature S12
Natural Convection (<0.1m/s airflow)
Vin > 60
Vin < 60
Rated Output Current (%)
100%
80%
60%
50%
40%
20%
0%
-20˚C
0˚C
20˚C
40˚C
60˚C
80˚C
100˚C
Ambient Temperature (˚C)
Figure 1.5: Derating Curve Output Current vs Temperature D12
Natural Convection (<0.1m/s airflow)
16
50%
40%
20%
-40˚C
-20˚C
0˚C
20˚C
40˚C
60˚C
80˚C
100˚C
Ambient Temperature (˚C)
Ambient Temperature (˚C)
-40˚C
60%
0%
0%
-40˚C
80%
Figure 1.4: Derating Curve Output Current vs Temperature D05
Natural Convection (<0.1m/s airflow)
CXA20 Series | 20W DC/DC
Isolated DC/DC converters
85%
86%
84%
S05
D05
S12
D12
82%
80%
S3V3
78%
18V
28V
38V
48V
58V
68V
Efficiency Vs Vin
17
Efficiency
Efficiency
84%
D05
D12
S12
SO5
83%
82%
81%
80%
S3V3
79%
-50˚C
-25˚C
0˚C
25˚C
50˚C
75˚C
100˚C
Efficiency Vs Temperature
Figure 2: Typical Efficiency vs Vin
Figure 3: Typical Efficiency vs Ambient Temperature
Figure 4: Typical Power-up Characteristic S05
(Ch1 : Input V, Ch2 : Vo), Vin = 48V, Load = 4A, 2000µF
Figure 5: Control On/Off Characteristic S05
(Ch1 : Control, Ch2 : Vo), Vin = 48V, Load = 4A, 2000µF
Figure 6.1: Typical Transient Response of S3V3
Ch1 Vo, 20mVAC/div. Ch2 Io, 2A/div
Figure 6.2: Typical Transient Response of S05
Ch1 Vo, 20mVAC/div. Ch2 Io, 1A/div
www.artesyn.com
SXA10 Series
| 10W
DC/DC
CXA20 Series
| 20W
DC/DC
Isolated DC/DC converters
18
Figure 6.3: Typical Transient Response of S12
Ch1 Vo, 50mVAC/div. Ch2 Io, 0.5A/div
Figure 6.4: Typical Transient Response of D05
Ch1 Vo2, 50mVAC/div. R1 Vo1 50mVAC/div. Ch2 Io, 1A/div
Figure 6.5: Typical Transient Response of D12
Ch1 Vo2, 50mVAC/div. R1 Vo1 50mVAC/div. Ch2 Io, 0.5A/div
Figure 7.1: Typical Ripple and Noise S3V3 on
Test Card at Nominal Conditions
Figure 7.2: Typical Ripple and Noise S05 on
Test Card at Nominal Conditions
Figure 7.3: Typical Ripple and Noise S12 on
Test Card at Nominal Conditions
CXA20 Series | 20W DC/DC
Isolated DC/DC converters
Figure 7.4: Typical Ripple and Noise D05 on
Test Card at Nominal Conditions
Figure 7.5: Typical Ripple and Noise D12 on
Test Card at Nominal Conditions
L100
NC
NC
S1 F1
F2 S2
NC
F3 S3
S1 F1
S2 F2
L100
Q102
Figure 8.1: Hot Spot Locations on S3V3,
S05 and S12 Models
19
www.artesyn.com
Figure 8.2: Hot Spot Location on D05
and D12 Models
CXA20 Series | 20W DC/DC
Isolated DC/DC converters
0.02 ±0.004
(0.50 ±0.1)
0.413
(10.50)
MAX.
OPEN
FRAME
HEIGHT
STAND-OFFS
4 PLACES
Ø0.040 ±0.004
(Ø1.02 ±0.1)
0.14 ±0.02
(3.60 ±0.5)
2.00 ±0.02
(50.80 ±0.5)
1.80
(45.72)
5
0.70
(17.78)
2.54
(0.10)
0.20
(5.08)
1.60 ±0.02
(40.64 ±0.5)
1
BOTTOM
VIEW
2
0.60
(15.24)
0.50
(12.70)
6
7
0.30
(7.62)
0.70
(17.78)
8
4
ALL DIMENSIONS IN INCHES (mm)
General tolerance ±0.010 (±0.25)
unless otherwise specified
Pin Connections
Pin Number
Single Output
Dual Output
1
2
3
4
5
6
7
8
Vin+
VinNo Pin
Remote On/Off
No Pin
Vo+
VoTrim
Vin+
VinNo Pin
Remote On/Off
Vo+
Common
VoTrim
Figure 9: Dimensions and Pinout
20
CXA20 Series | 20W DC/DC
Isolated DC/DC converters
Note 1
Hot spot temperature is defined as the highest temperature
measured at any one of the specified temperature hotspot
checkpoints. See Figure 8: Hotspot temperature check points.
Note 2
The control pin is referenced to Vin-.
Note 3
The CXA20 is supplied as standard with active high logic.
Control input pulled low: unit disabled.
Control input floating: unit enabled.
The unit can be supplied with active low logic.
Note 4
Parallel operation of multiple units is not recommended. If
parallel operation is required outputs should be decoupled by
diodes. Control inputs of multiple units should not be connected
but decoupled by diodes or transistors.
Note 5
Thermal reference set up: Unit mounted centrally on a 200mm x
240 mm testboard. Testboard is mounted vertically in a fully
enclosed 300mm x 300mm x 300mm testbox. Ambient
temperature measured at the bottom of the textbox. Altitude sea
level.
Note 6
On the dual output models OVP protection is on positive outputs
only. See Application Note for details.
Note 7
For balanced loads. In the case of unbalanced loads a minimum
load of 10% is required on each output to maintain cross
regulation.
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is accessible only to trained personnel. The user
must provide the recommended fusing in order to comply with
safety approvals.
21
www.artesyn.com
CXA20 Series | 20W DC/DC
Isolated DC/DC converters
NORTH AMERICA
e-mail: [email protected]
☎ 800 769 7274
☎+ 508 628 5600
EUROPEAN LOCATIONS
e-mail: [email protected]
IRELAND
☎+ 353 24 93130
AUSTRIA
☎+ 43 1 80150
FAR EAST LOCATIONS
e-mail: [email protected]
HONG KONG
☎+ 852 2699 2868
DS_CXA20_20000119.PDF
Data Sheet  Artesyn Technologies® 2000
The information and specifications contained in this data sheet are
believed to be correct at time of publication. However, Artesyn
Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to
change without notice. No rights under any patent accompany the
sale of any such product(s) or information contained herein.
22
www.artesyn.com