E Series Multifunction DAQ – 500 kS/s, 12-Bit, 16 or 64 Analog Inputs NI 606xE NI 606xE NI 6060E (MIO-16E-2) AT-MIO-16E-2 NI 6061E (MIO-64E-3) AT-MIO-64E-3 Counter/Timers NI 6062E Analog and digital 2 up/down, 24-bit resolution Triggering DAQCard-6062E Driver Software Analog Inputs NI-DAQ Windows 2000/NT/Me/9x 16 single-ended, 8 differential channels (6060E, 6062E) 64 single-ended, 32 differential channels (6061E) Up to 500 kS/s sampling rate Up to 500 kS/s stream-to-disk rate 12-bit resolution Application Software LabVIEW Measurement Studio VirtualBench Measure Lookout Analog Output Calibration Certificate Included 2 channels, 12-bit resolution See page 256. Digital I/O 8 (5 V/TTL) lines Overview Calibration DACs Voltage REF 3 Muxes Calibration Mux 12-Bit Sampling A/D Converter NI-PGIA Gain Amplifier – Mux Mode Selection Switches I/O Connector AI Control EEPROM IRQ DMA Analog Trigger Circuitry Trigger Data Transceivers Dither Circuitry Configuration Memory 2 Trigger Level DACs ADC FIFO Analog Input Timing/Control DMA/ Interrupt Request PFI / Trigger Trigger Timing Counter/ Timing I/O DAQ - STC Bus Interface Digital I/O Analog Output Timing/Control RTSI Bus Interface Digital I/O (8) 8 Analog Input Control EEPROM Control DMA Interface DAQ-STC Bus Interface DAQ-PnP Plug and Play Analog Output Control 8255 DIO Control Bus Interface 3 ISA – I/O Channel (8/32) + Analog Data (16) (8/32) AO Control DAC FIFO DAC0 Data (16) DAC1 6 Calibration DACs RTSI Bus Figure 1. NI 6060E and NI 6061E Hardware Block Diagram EXPRESS The NI 6060E, NI 6061E, and NI 6062E CODES DAQ devices use E Series technology to deliver high performance and reliable data For information or to acquisition capabilities for a wide range of buy products online, visit ni.com/catalog applications. You get up to 500 kS/s, 12-bit and enter: performance and either 16 or 64 singleatmio16e2 ended analog inputs. Depending on your atmio64e3 daqcard6062e hard drive type, these devices can stream data to disk at rates up to 500 kS/s. These E Series DAQ devices feature analog and digital triggering capability, as well as two 12-bit analog outputs, two 24bit 20 MHz counter/timers, and eight digital I/O lines. See the E Series Multifunction DAQ Overview on page 306 for a more detailed hardware overview. Family NI 6060E NI 6061E NI 6062E Bus ISA ISA PCMCIA Analog Inputs 16 SE/8 DI 64 SE/32 DI 16 SE/8 DI Resolution 12 bits 12 bits 12 bits Sampling Rate (S/s) 500 k 500 k/333 k 500 k Input Range ±0.05 to ± 10 V ±0.05 to ± 10 V ±0.05 to ± 10 V Analog Outputs 2 2 2 Resolution 12 bits 12 bits 12 bits Output Rate 1 MS/s 1 MS/s 850 kS/s* Output Range up to ± 10 V up to ± 10 V up to ± 10 V Digital I/O 8 8 8 Counter/ Timers 2, 24-bit 2, 24-bit 2, 24-bit Triggers Analog and Digital Analog and Digital Analog and Digital Measurements Also consider the NI 6070E devices. See page 314. *Single channel rate Table 1. NI 606xE Families Channel, Speed, and Resolution Specifications (refer to page 344 for detailed specifications) National Instruments Tel: (512) 794-0100 • Fax: (512) 683-9300 • [email protected] • ni.com 317 NI 606xE E Series Multifunction DAQ – 500 kS/s, 12-Bit, 16 or 64 Analog Inputs Absolute Accuracy Relative Accuracy Noise + Quantization (mV) Nominal Range (V) Positive Offset (mV) Negative FS % of Reading FS Single Pt. Absolute Accuracy Averaged NI 6060E/ DAQCard- NI 6060E/ DAQCard- NI 6060E/ DAQCard6062E Temp Drift Resolution (mV) at Full Scale (mV) Single Pt. Averaged NI 6060E/ DAQCard- NI 6060E/ DAQCard- NI 6060E/ DAQCard- 24 Hrs 1 Year NI 6061E 6062E NI 6061E NI 6061E 6062E (%/°C) NI 6061E NI 6061E 6062E NI 6061E 10 -10 0.0672 0.0714 6.38 9.83 4.64 6.10 0.846 0.975 0.0010 14.369 17.945 6062E 6.27 7.37 1.11 6062E 1.28 5 -5 0.0272 0.0314 3.20 4.92 2.32 3.05 0.423 0.488 0.0005 5.193 6.983 3.14 3.68 0.557 0.642 2.5 -2.5 0.0672 0.0714 1.61 2.47 1.16 1.53 0.211 0.244 0.0010 3.605 4.502 1.57 1.84 0.278 0.321 1 -1 0.0672 0.0714 0.653 1.001 0.464 0.610 0.085 0.098 0.0010 1.452 1.813 0.627 0.737 0.111 0.128 0.5 -0.5 0.0672 0.0714 0.335 0.511 0.232 0.305 0.042 0.049 0.0010 0.735 0.917 0.314 0.368 0.056 0.064 0.25 -0.25 0.0672 0.0714 0.176 0.266 0.116 0.208 0.021 0.029 0.0010 0.376 0.474 0.157 0.238 0.028 0.039 0.1 -0.1 0.0672 0.0714 0.081 0.119 0.068 0.098 0.010 0.012 0.0010 0.162 0.203 0.080 0.111 0.013 0.016 0.05 -0.05 0.0672 0.0714 0.049 0.070 0.049 0.071 0.006 0.008 0.0010 0.090 0.113 0.056 0.082 0.007 0.010 3.20 4.92 2.32 3.05 0.423 0.488 0.0005 6.765 8.555 3.14 3.68 0.557 0.642 10 0 0.0272 0.0314 5 0 0.0672 0.0714 1.61 2.47 1.16 1.53 0.211 0.244 0.0010 5.391 6.288 1.57 1.84 0.278 0.321 2 0 0.0672 0.0714 0.653 1.001 0.464 0.610 0.085 0.098 0.0010 2.167 2.528 0.627 0.737 0.111 0.128 1 0 0.0672 0.0714 0.335 0.511 0.232 0.305 0.042 0.049 0.0010 1.092 1.274 0.314 0.368 0.056 0.064 0.5 0 0.0672 0.0714 0.176 0.266 0.116 0.208 0.021 0.029 0.0010 0.554 0.653 0.157 0.238 0.028 0.039 0.2 0 0.0672 0.0714 0.081 0.119 0.068 0.098 0.010 0.012 0.0010 0.233 0.274 0.080 0.111 0.013 0.016 0.1 0 0.0672 0.0714 0.049 0.070 0.049 0.071 0.006 0.008 0.0010 0.126 0.149 0.056 0.082 0.007 0.010 Note: Accuracies are valid for measurements following an internal E Series Calibration. Averaged numbers assume dithering and averaging of 100 single-channel readings. Measurement accuracies are listed for operational temperatures within ±1 °C of internal calibration temperature and ±10 °C of external or factory-calibration temperature. One-year calibration interval recommended. The Absolute Accuracy at Full Scale calculations were performed for a maximum range input voltage (for example, 10 V for the ±10 V range) after one year, assuming 100 pt averaging of data. See overview on page 312 for an example calculation of this type. Table 2. NI 606xE Analog Input Accuracy Specifications Absolute Accuracy Absolute Accuracy at Offset (mV) Nominal Range (V) % of Reading Positive FS Negative FS Full Scale (mV) NI 6060E/ DAQCard- Temp NI 6060E/ DAQCard- NI 6061E 6062E 24 Hrs 90 Days 1 Year NI 6061E 6062E Drift (%/°C) 10 -10 0.0177 0.0197 0.0219 5.93 8.37 0.0005 8.127 10 0 0.0177 0.0197 0.0219 3.49 - 0.0005 5.685 10.568 - Note: Temp Drift applies only if ambient is greater than ±10 °C of previous external calibration. See page 312 for example calculations. Table 3. NI 606xE Families Analog Output Accuracy Specifications Voltage REF Calibration DACs 3 (8) Muxes + I/O Connector Calibration Mux 12-Bit Sampling A/D Converter NI-PGIA Gain Amplifier – Mux Mode Selection Switches Ordering Information ADC FIFO Dither Circuitry Configuration Memory AI Control NI 6060E PCMCIA Connector Analog Data (16) (8) EEPROM 2 Trigger Level DACs Trigger IRQ Analog Trigger Circuitry PFI / Trigger Trigger Analog Input Timing/Control Interrupt Request Timing Counter/ Timing I/O DAQ – STC Bus Interface Digital I/O Analog Output Timing/Control RTSI Bus Interface Digital I/O (8) Analog Input Control EEPROM Control NI 6061E AT-MIO-64E-3.....................................................776911-01 DAQ-PCMCIA DAQ-STC Bus Interface Analog Output Control Bus Interface NI 6062E DAQCard-6062E................................................777976-01 DAC0 Measurements AT-MIO-16E-2.....................................................776791-01 AO Control DAC1 Includes NI-DAQ for Windows 2000/NT/Me/9x. DAC FIFO 6 Calibration DACs Figure 4. NI 6062E Hardware Block Diagram See page 310 in the E Series Multifunction DAQ Overveiw for I/O connector diagrams. Extended warranty and value added services ...........................................page 880 Recommended Configurations Family NI 6060E NI 6061E NI 6062E DAQ Device AT-MIO-16E-2 AT-MIO-64E-3 DAQCard-6062E Accessory SCB-68 (776844-01) SCB-100 (776990-01) SCB-68 (776844-01) See page 334 for accessory and cable information. 318 National Instruments Tel: (512) 794-0100 • Fax: (512) 683-9300 • [email protected] • ni.com Cable SH6868-EP (184749-01) SH100100 (182853-01) SHC6868-EP (186838-01)