10/01 Page 1 of 8 43-TV-03-08 eZtrend V5 Electronic Data Recorder Specification Function Honeywell’s eZtrend recorder provides cost effective electronic data recording in a compact DIN size recorder. The recorder accepts up to 6 universal analog inputs and stores data on an integral, removable storage media. The data is displayed on a five inch color LCD with wide viewing angles. The operator interface provides easy access to the recorder menus for quick set up and replaying of the data. Data is stored under pen configurations, in secure files and since the data is directly related to a pen there is no need to remember file names and files structures. An Ethernet connection is provided standard to allow direct connection of the recorder to a LAN or the Internet. The TrendManager Software Suite ties your process together. Access the recorders through the plant wide LAN or Internet. Trend Manager provides the tools for real-time communications, data analysis, and configuration, for the entire family of electronic data recorders including the eZtrend recorder. Features Features, continued Features, continued • Five Inch Color Display — makes it easy to interpret process data and take action with the easy to understand bar charts, digital values and trends. • Ethernet Connectivity — provides unlimited connectivity to local area networks (LANs) or the internet. • Paperless Chart Recording — eliminates the need for paper and pens with their associated cost and mess. • Total Data Integrity — data is stored in secure files based on pen designations making it easy to retrieve the data based on process information rather then having to remember file names. • Up to 6 Analog Inputs — up to six universal analog inputs that can monitor process variables from a variety of sensors. • Data Storage — data is stored on a standard 1.44MB floppy. • DIN Standard Mounting — fits standard DIN cutout and allows for easy replacement of existing 100mm paper chart recorders. • CE Mark — Conformity with 73/23/EEC, Low Voltage Directive • Independent Display Chart Speeds and Logging rates — logging rates can be programmed completely separate from the chart display speed, allowing the data to be displayed and stored at the rates that are best suits the application. • Universal Power — no concern with plugging the recorder into the wrong voltage - the instrument is designed to work between 90 and 250 Vac. • Real Time Clock — provides accurate time stamping of logged data and events and is battery backed up to prevent a loss of the clock time/date • Large Memory Buffer — 2Mbyte battery backed buffer insures that data is not lost during routine operation • Password Protection — multiple levels of password protection provided to insure compliance with 21CFR Part 11. Up to 4 levels of password protection with up to ten different passwords are available for use. The password can prevent unauthorized entry to the entire recorder configuration or just portions of the recorder configuration or • Fuzzy Logging — This standard feature provides a unique method to increase the storage capacity of the recorder. The data is monitored to determine changes in process data, if no changes are observed data is logged periodically. If data is changing rapidly it is recorder normally at the programmed rate. By not logging data that is static, data compression of up to 100:1 or more can be observed saving valuable disk space. The amount of disk space left is easily observed and can be set up as an alarm limit to insure that data is not lost. • Alarms — up to thirty-two integral “soft” alarms are easily set by users to announce selected, out-of-limit conditions. Sensing and Control, 11 West Spring Street, Freeport, Illinois 61032 Printed in U.S.A. © Copyright 2001—Honeywell 43-TV-03-08 Page 2 and 89/336/EEC EMC Directive. operation. Options •Alarm Output — up to six integral SPDT relays are available to activate user’s external equipment. • Math — A full function math capability is provided. This feature handles up to a 200-character math expression. Math also includes 6 extra virtual pens. • Digital Input — the six-relay option also includes two digital inputs. The digital inputs allow users to initiate from a remote location through the two dry contact closures, selected recorder functions, such as start/stop/reset totalization, mark the chart. • Event Markers — provides an easy method for a user to mark an event or message on the electronic recorder. These messages are time stamped and can be up to 44 characters long. Additionally, certain recorder actions such as start/stop recording, digital inputs actions, user key presses, etc. can also be logged. • Customer ID Tagging 3 Vertical Trends w/Horizonal Bars 6 Vertical Bars 3 Horizontal Trends w/ Vertical Bars 6 Horizontal Bars Trend Manager Suite • TrendViewer — Standard software package for viewing, graphing, and printing stored data. • TrendManager Pro — this is an advanced data analysis/archiving software package. It provides full configuration of the recorders along with e-mail set up. TrendManager Pro also allows files to be exported using comma separated variables (CSV) format. • TrendServer Pro — is a fully network aware software package for communicating with the recorders. It supports all the capabilities of Trend Manager Pro plus FTP (file transfer protocol) and Web browser access. TrendServer Pro provides multi-level, multi-user access to the recorder data by various departments with security. 4 Vertical Trends w/ Horizontal Bars 3 Horizontal Trends Panel Meter 3 Vertical Trends 43-TV-03-08 Page 3 Specifications Design Attributes Digital Indication & Display Display Type: Color STN QVGA Display Screen Size: 5” diagonal Resolution: 320 x 240 pixels Display update rate: Values updated every 250 ms Analog Trace Colors Pen 1 - Dark Red, Pen 2 - Blue, Pen 3 - Green, Pen 4 - Magenta, Pen 5 - Cyan, Pen 6 - Bright Red Data Storage Media: 3.5” 1.44MB floppy (Standard) Internal Data Buffer: 2 Mbytes Setup: Stored in EEPROM Data Storage Capacity # of Pens Estimated Disk Capacity (1.44MB Floppy) 2 4D, 2Hr 40D, 17Hr 122D 244D 3.3 Years 6.6 Years 4 2D, 1Hr 20D, 8Hr 61D 122D 1.67 Years 3.3 Years 6 1D, 8Hr 13D, 8Hr 40.5D 81D 1.1 Years 2.2 Years Rate 1 Sec 10 Sec 30 Sec 60 Sec 5 Min 10 Min Display Chart Speeds mm/hour: 1, 5, 20, 30, 60, 120, 600, 1200 (2.7 days to 3.25 minutes) Communications Ethernet 10 Base-T connector (Standard) supports FTP Protocol, Trendbus (Real Time), Web. Clock Calendar function, daylight savings time adjustable manually or with comms Time can be adjusted and synchronized using Ethernet scheduler Tolerance: 20ppm to resolution of 1 second Battery backed up, Lithium battery - 10 years life (powered) Alarm Set Points Up to 32 integral “soft” alarm set points easily set by user to announce selected out of limit conditions. Languages English, French, German, Italian, Spanish This product is in conformity with the protection requirements of the following European Council CE Conformity Directives: 73/23/EEC, the Low Voltage Directive, and 89/336/EEC, the EMC Directive. Conformity of this product with any other “CE Mark” Directive(s) shall not be assumed. Product Classification Enclosure Rating Installation Category (Overvoltage Category) Pollution Degree EMC Classification Safety Class I: Cord Connected, Panel Mounted Industrial Control Equipment with protective earthing (grounding). (EN 61010-1) Front panel IP 65 (IEC 529) Category II: (EN 61010-1) Pollution Degree 2: (Ref. IEC 664-1) Group 1,Class A, ISM Equipment (EN 55011, emissions), Industrial Equipment (EN 61326, immunity) Complies with EN61010-1. Panel Mounted Equipment, Terminals must be enclosed within the panel. Analog Inputs Number of Inputs Input Types Minimum Input Span Input Resolution Input Impedance Source Impedance Input Sampling Rate Input Sampling Method Input Filter Linear Input Scaling Input Isolation Insulation Resistance 2, 4 or 6 Universal inputs EMF (mv, V, mA), Thermocouple, RTD Range is fully configurable with span limitation of the operating range selected 16 bits (0.015%) Current loop resistance dc: 10 ohms ± 5% All others: 1 Meg Ohm RTD: 40 ohms per lead maximum 100msec for all inputs Method: Sample, Average, Min-Max Single Low pass filter software adjustable 1 to 15 seconds -999999 to 999999, scale factor of 1 to 9999 Decimal Point automatic or programmable Engineering units, user definable (5 characters) Common Mode: 250 Volts AC Normal Mode: 250 Volts AC >9.9MΩ Each terminal to ground terminal Logging Logging Method Logging Types Logging Rates Fuzzy Logging Method: Sample, Average, Min-Max Continuous, Events, Fuzzy 100mSec to 4 days per log A secure data storage technique which typically delivers data compression ratio of 100:1. or more; self teaching, storing the data at a variable rate to match the process 43-TV-03-08 Page 4 Performance Input Actuation (Linear) Millivolts dc Volts dc Range Accuracy -100 to 100 -200 to 200 -1.0 to 1.0 -10 to 10 ±0.04% ±0.04% ±0.04% ±0.04% Temp. Stability ±0.01%/˚C ±0.01%/˚C ±0.01%/˚C ±0.01%/˚C Note for 4-20mA inputs: signal needs to be converted to millivolt or voltage signal and input actuation set to this. (That is, 10 ohm resistor and use ±200 mv input actuation or 250 ohm and use ±10 volt actuation.) Input Actuation (Thermocouples) B C(W5) E J K L N (Nicrosil Nisil) Range °F 32 to 32 to 1182 to 32 to 32 to 32 to -328 to -328 to 32 to -328 to -328 to 32 to 1832 to -328 to -328 to 212 to -328 to -328 to 3182 1112 3182 4172 4172 1472 2174 32 2174 2192 32 1832 2462 1652 212 1652 2372 32 32 to 2732 R S T W Chromel/Copel Input Actuation (RTD’s) PT100 100 ohms (To BS1904) PT200 200 ohms CU53 Ni120 Accuracy °C 32 to 3092 32 to 572 572 to 3092 32 to 3092 32 to 572 572 to 3092 -328 to 752 -328 to 32 32 to 752 1832 to 4172 1832 to 3272 3272 to 4172 -74 to 1110 -74 to 1110 °F ± °F 0 to 1820 0 to 600 600 to 1750 0 to 2300 0 to 2300 -200 to 1000 -200 to 1190 -200 to 0 0 to 1190 -200 to 1350 -200 to 0 0 to 1000 1000 to 1350 -200 to 900 -200 to 100 100 to 900 -200 to 1300 -200 to 0 0 to 1300 0 to 1750 0 to 300 300 to 1750 0 to 1750 0 to 300 300 to 1750 -200 to 400 -200 to 0 0 to 400 1000 to 2300 1000 to 1800 1800 to 2300 -50 to 600 -50 to 600 °C Temp. Stability ± Degrees Error Per 1 Degree ∆T ± °C ±% Span 18 7.2 10 4 0.7% 0.3% 0.15%/˚C 0.13%/˚C 9 3.6 5.5 2 0.3% 0.3% 0.06%/˚C 0.06%/˚C 5.4 2.7 3 1.5 0.25% 0.15% 0.03%/˚C 0.03%/˚C 5.4 3.6 4.5 3 2 2.5 0.2% 0.15% 0.15% 0.03%/˚C 0.03%/˚C 0.03%/˚C 5 2.7 2.75 1.5 0.3% 0.3% 0.03%/˚C 0.03%/˚C 5.4 5 3 2.75 0.2% 0.2% 0.05%/˚C 0.04%/˚C 7.2 5.4 4 3 0.3% 0.2% 0.1%/˚C 0.1%/˚C 7.2 5.4 4 3 0.3% 0.2% 0.1%/˚C 0.1%/˚C 3.6 1.8 2 1 0.35% 0.2% 0.08%/˚C 0.08%/˚C 5.4 5.4 3 3 0.3% 0.3% 0.15%/˚C 0.15%/˚C 1.8 ± °F 1 ± °C 0.3% ±% Span 0.05%/˚C –328 to 752 –200 to 650 2.7 1.5 0.2% 0.05%/˚C –328 to 752 32 to 300 -112 to 464 –200 to 180 0 to 150 2.7 2.7 2.7 1.5 1.5 1.5 0.4% 0.9% 0.5% 0.05%/˚C 0.05%/˚C 0.05%/˚C Reference Temperature: 20°C Reference Humidity: 65% RH ±15% Reference junction Accuracy: ±1.0 degrees Centigrade. -80 to 240 Reference sample rate:2 Hz (500 msec) CJC Temperature Effect: ±0.05°C/°C Long term stability: 0.2%/year 43-TV-03-08 Page 5 Specifications, continued Physical Parameters Enclosure Mounting (Panel) Dimensions Weight Color Wiring Connections Galvanized steel with high impact resistant polycarbonate plastic bezel and scratch resistant lens. With proper panel mounting and required gasketing the eZtrend is designed to be splashproof. Mounting adjustable for panel thickness of 2 to 20mm Adapter kits available for covering existing panel cutouts. See Figure 3 2.5Kg Bezel: Black IEC Power Plug. Removable terminal strip for input and alarm connections Options Alarm Output Digital Input Totalizers Math Algorithms Event Markers Miscellaneous Four or six relays. Six Relay Option includes two digital inputs Relay Contact Ratings: 3 Amp 120VAC with Resistive Load, SPDT Two voltage free contacts available as part of the Six Relay Option Available as part of Math Option. One totalizer per input. Totalizer value is assigned to a pen for data storage. Totalization values are ten digits plus exponent Free form math, supports 200 character expression. Supports common operators +, -, *, /, Totals, Modulus, Over, Under, , Out, CJC, Memory Use, Disk Use, PC Card Use, Pens, Outputs, Absolute Value, Hi, Lo, Idle. Math includes 6 extra virtual pens Event Messages can be up to 44 Characters, Event Causes: Into Alarm, Out of Alarm, Disk % Full, Totalizer Start/Stop/Reset, Dig. In High, Dig. In Low, Relay High, Relay Low, T/C Open Circuit Event Effects: Mark Chart, Logging, Start/Stop Totalizer, Set/Clear Relay, e-Mail Customer ID Tagging (3 lines of up to 22 characters each line) Environmental and Operating Conditions Parameter Ambient Temperature Relative Humidity (%RH) Vibration Frequency (Hz) Acceleration (g) Mechanical Shock Acceleration (g) Duration (ms) Mounting Position from Vertical Tilted Forward Tilted Backward Tilted to Side (±) Power Requirements Voltage (VRMS) Frequency (Hz) Power Consumption Reference 67 to 77 °F 19 to 25 °C Rated 58 to 104 °F 15 to 40 °C Extreme 32 to 122 °F 0 to 50 °C (without Floppy) Transport and storage –14 to 140 °F –10 to 60 °C 50 to 65* 10 to 90* 5 to 90* 5 to 95* 0 0 0 to 70 0.1 0 to 100 0.2 0 to 100 0.5 0 0 1 30 5 30 20 30 5° 5° 5° 20° 20° 20° 25° 25° 25° Any Any Any 119 to 121 49.8 to 60.2 20 VA maximum 90 to 250 47 to 440 90 to 250 47 to 440 N/A N/A * The maximum rating only applies up to 104°F (40°C). For higher temperatures, the RH specification is derated to maintain constant moisture content. 43-TV-03-08 Page 6 WARNING Recorder Wiring DISCONNECT POWER BEFORE REMOVING COVER Accepts T/C, mV, V, mA, RTD IEC Power Plug for AC Power Accepts up to 6 Alarm Outputs/2 Digital CH a CH b * * Compensation ETHERNET 10 BASE T CH1 CH2 CH3 CH4 ANALOGUE INPUTS CH5 T/C, mV,V, mA RTD CH6 2 -25 (.08"-1.0") 144 (5.67") 138 (5.43") Panel Rear of "box" Mounting 144 Bar slots top & bottom (5.67") Panel Panel 138 Cutout Cutout (5.43") >7 (0.28") >60 (2.37") Front bezel dimensions 17 (.67") Panel Cutout 192 (7.56") 175 (6.89") 205 (8.07")Min.* NOTE: Dimensions in mm (inches) * Power Plug dependent For straight plug allow additional 30mm min. Figure 3— eZtrend recorder dimensions - for reference only Spacing for adjacent mounting 43-TV-03-08 Page 7 Ordering Information For complete ordering information, request Model Selection Guide 43-TV-16-08 Honeywell offers a full line of sensors and transmitters that produce a compatible range of dc voltage or current signals which can be used as inputs to the eZtrend Recorder. T V E Z 2 = 2 Analog Inputs 4 = 4 Analog Inputs 6 = 6 Analog Inputs Discrete I/O 0 = None 4 = 4 Relay Out 6 = 6 Relay/2 Digital Inputs Firmware Options 0 = None M = Totalizers (Math) Communications/ Inst. Power 0 _ _ = Ethernet (FTP, Web, Real Time Trendbus) Instrument Power _ 0 _ = Universal Power (90 - 240 Vac) Future Factory Use Options 0_____ H_____ P_____ _U____ __0___ __L___ __S___ ___0__ ____0_ ____B_ ____C_ ____ E_ _____ 0 _____V _____P _____S = Std. Panel Mount = Case with Handle Attached = Portable Case = English Manual = None = Linen Tag = Stainless Steel Tag = CE Approval Std = None = Cert. of Conformance = Calibration Certificate = Calib & Conformance Certificate = None = Trend Viewer = Trend Manager Pro = Trend Server Pro _ _ 0 = None Data Storage 0 = 1.44MB Floppy WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local sales office for warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace without charge those items it finds defective. The foregoing is Buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. 43-TV-03-08 Page 8 ARGENTINA BULGARIA GERMANY NORWAY REPUBLIC OF SOUTH SWEDEN HONEYWELL S.A.I.C. HONEYWELL EOOD HONEYWELL AG HONEYWELL A/S AFRICA HONEYWELL A.B. BELGRANO 1156 14, Iskarsko Chausse Kaiserleistrasse 39 Askerveien 61 HONEYWELL S-127 86 Skarholmen BUENOS AIRES POB 79 D-63067 OFFENBACH PO Box 263 Southern Africa STOCKHOLM ARGENTINA BG- 1592 Sofia GERMANY N-1371 ASKER PO BOX 138 SWEDEN Tel. : 54 1 383 9290 BULGARIA Tel. : 49 69 80 64299 NORWAY Milnerton 7435 Tel. : 46 8 775 55 00 Tel. : 47 66 76 20 00 REPUBLIC OF SOUTH ASIA PACIFIC HONEYWELL ASIA Tel : 359-791512/ 794027/ 792198 HUNGARY HONEYWELL Kft POLAND AFRICA Tel. : 27 11 805 12 01 SWITZERLAND HONEYWELL A.G. PACIFIC Inc. CANADA Gogol u 13 HONEYWELL Sp.z.o.o Room 3213-3225 HONEYWELL H-1133 BUDAPEST UI Domainewksa 41 ROMANIA 8304 WALLISELLEN Sun Kung Kai Centre The Honeywell Centre HUNGARY 02-672 WARSAW HONEYWELL Office SWITZERLAND N° 30 Harbour Road 155 Gordon Baker Road Tel. : 36 1 451 43 00 POLAND Bucharest Tel. : 41 1 831 02 71 WANCHAI Toronto, Ontario M2H 3N7 Tel. : 48 22 606 09 00 147 Aurel Vlaicu Str., HONG KONG Tel. : 416-502-4666 ICELAND Sc.Z., HONEYWELL PORTUGAL CZECH Hataekni .hf AUSTRALIA REPUBLIC HONEYWELL LIMITED Hertistrasse 2 TURKEY Apt 61/62 HONEYWELL HONEYWELL R-72921 Bucharest Otomasyon ve Kontrol Armuli 26 PORTUGAL LDA ROMANIA Sistemlen San ve Tic A.S. HONEYWELL, Spol.s.r.o. PO Box 8336 Edificio Suecia II Tel40-1 211 00 76/ (Honeywell Turkey A.S.) 5 Thomas Holt Drive Budejovicka 1 128 reykjavik Av. do Forte nr 3 - Piso 3 211 79 Emirhan Cad No 144 North Ryde Sydney 140 21 Prague 4 Iceland 2795 CARNAXIDE NSW AUSTRALIA 2113 Czech Republic Tel. : 61 2 353 7000 Tel. : 42 2 6112 3434 AUSTRIA DENMARK Via P. Gobetti, 2/b REPUBLICOF Builiding of AO "Luzhniki" HONEYWELL AUSTRIA HONEYWELL A/S 20063 Cernusco Sul IRELAND Management G.m.b.H. Automatikvej 1 Naviglio HONEYWELL 24 Luzhniki UNITED Handelskai 388 DK 2860 Soeborg ITALY Unit 1 119048 Moscow KINGDOM A1020 VIENNA DENMARK Tel. : 39 02 92146 1 Robinhood Business Park RUSSIA HONEYWELL AUSTRIA Tel. : 45 39 55 56 58 Robinhood Road Tel : 7 095 796 98 00/01 Unit 1,2 &4 Zodiac House Tel. : 852 829 82 98 Tel. : 43 1 727 800 ITALY HONEYWELL S.p.A. MEXICO PORTUGAL Tel. : 351 1 424 50 00 DUBLIN 22 RUSSIA HONEYWELL INC 4 th Floor Administrative Barbaros Plaza C. Blok Kat 18 Dikilitas 80700 Istanbul TURKEY Tel : 90-212 258 18 30 Calleva Park FINLAND HONEYWELL S.A. DE BELGIUM HONEYWELL OY CV HONEYWELL S.A. Ruukintie 8 AV. CONSTITUYENTES 3 Avenue de Bourget FIN-02320 ESPOO 32 900 REPUBLICOF PO Box 75 B-1140 BRUSSELS FINLAND COL. LOMAS ALTAS SINGAPORE 820 07 BRATISLAVA 27 BELGIUM Tel. : 358 0 3480101 11950 MEXICO CITY HONEYWELL PTE LTD SLOVAKIA U.S.A. Tel. : 32 2 728 27 11 FRANCE MEXICO BLOCK 750E CHAI CHEE Tel. : 421 7 52 47 400/ HONEYWELL INC. Tel : 52 5 259 1966 ROAD 425 1100 VIRGINIA DRIVE BRAZIL HONEYWELL S.A. HONEYWELL DO BRA- Bâtiment « le Mercury » THE ZIL AND CIA Parc Technologique de St NETHERLANDS Rua Jose Alves Da Aubin HONEYWELL BV Chunha Route de l’Orme Laaderhoogtweg 18 Lima 172 (CD 128) 1101 EA AMSTERDAM BUTANTA 91190 SAINT-AUBIN 05360.050 SAO PAULO Republic of Ireland Tel. : 353 1 4565944 06-01 CHAI CHEE IND. PARK 1646 SINGAPORE REP. OF SINGAPORE Tel. : 65 2490 100 SLOVAKIA HONEYWELL Ltd Mlynske nivy 73 SPAIN HONEYWELL S.A Factory Josefa Valcarcel, 24 Aldermaston Berkshire RG7 8HW UNITED KINGDOM Tel : 44 118 906 2600 FT. WASHINGTON PA 19034-3260 U.S.A. Tel. : 1-800-343-0228 28027 MADRID VENEZUELA ZO SPAIN HONEYWELL CA FRANCE THE NETHERLANDS Tel. : 34 91 31 3 61 00 APARTADO 61314 SP Tel. from France: Tel : 31 20 56 56 911 BRAZIL 01 60 19 80 00 VENEZUELA Tel. : 55 11 819 3755 From other countries: Tel. : 58 2 239 0211 33 1 60 19 80 00 Sensing and Control Honeywell 11 West Spring Street Freeport, IL 61032 43-TV-03-08 1001 Printed in USA www.honeywell.com/sensing 1060 CARACAS