3UA Thermally Delayed Overload Relays CLASS 10 Technical data according to IEC 947-4 Type 3UA70 11/ 3UA70 21 Trip class CLASS 10A (2 s < tA ≤10 s at 7.2 ×Ie from cold state and tA ≤2 min at 1.5 ×Ie from hot state) Phase failure sensitivity by differential phase shift yes yes yes yes yes Changeover to automatic reset no yes yes yes RESET button with trip-free feature yes yes yes Temperature compensation yes yes Switch position indicator yes yes Test button actuates the NO and NC contacts yes Terminal for contactor coil Permissible ambient temperature °C Degree of protection 3UA50/ 3UA52 3UA55 3UA58 3UA59 3UA60 3UA61/ 3UA62 3UA66 3UA68 yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes no1) yes yes no1) no1) no1) no1) no1) no1) –25 to +552) –25 to +55 IP 00/open or IP 20 to IEC 947-1 and DIN 40 050 g/ms 8/10 AC/DC V 690 690 690 1000 690 1000 1000 1000 1000 6 6 6 8 6 8 8 8 8 Shock resistance Main circuit Rated insulation voltage Ui (pollution degree 3) Rated impulse withstand voltage Uimp kV Type of current, frequency range DC; AC up to 400 Hz AC 50 to 400 Hz Conductor cross-sections Terminal screw solid or stranded finely stranded with end sleeve Flat bars Setting range (≤200 A/ >200 A) mm2 mm2 mm Tightening torque Nm lb. in Nm lb. in M3 0.5 to 2.5 0.5 to 1.5 M4 2.5 to 6 1.5 to 4 M5 1.5 to 25 1 to 16 M5 2.5 to 35 1.5 to 25 M5 1.5 to 25 1 to 16 M6 25 to 70 25 to 50 M8 50 to 120 25 to 95 M 8/M 10 185/240 – M 10 2 ×240 – – – – – – – 2 0× 3 1 to 1.5 9 to 13 2.5 to 3 22 to 26.5 2.5 to 3 22 to 26.5 2.5 to 3 22 to 26.5 6 to 8 52 to 50 10 to 14 89 to 124 2 0× 3/ 2 ×30 ×5 10 to 14 89 to 124/ 14 to 24 124 to 210 2 ×30 ×5 0.4 to 0.7 4 to 6.5 14 to 24 124 to 210 Power loss per conducting path (max.) at lowest value W (VA) 0.6 0.9 1.2 2.6 0.8 5 5 4 ( 5) 6 ( 9) at highest value of the setting range W (VA) 2.3 2.25 3 4 2 7 7 10 (12) 15 (22) 1) Not required. 2) The upper setting Io is to be reduced by 0.5% per 1°C excess temperature or a min. space of 5 mm is to be maintained between the units when several overload relays are series mounted and simultaneously operated at ambient temperatures exceeding 25 °C. 3UA Thermally Delayed Overload Relays CLASS 10 Technical data according to IEC 947-4 Type 3UA70 11/ 3UA70 21 3UA50/ 3UA52 3UA55 3UA58 1 NO + 1 NC 1 NO + 1 NC M3 2×(0.5 to 2.5) 2×(0.5 to 1.5) M 3.5 2 ×(0.5 to 1)/2× (1 to 2.5) 2 ×(0.5 to 1)/2× (0.75 to 2.5) 0.4 to 0.7 4 to 6.5 0.8 to 1.4 7 to 12 3UA59 3UA60 3UA61/ 3UA62 3UA66 3UA68 Auxiliary circuit Rated insulation voltage Ui (pollution degree 3) V Rated impulse withstand voltage Uimp kV 690 24 A 2 Conventional thermal current Ith A 60 at DC-13: 125 1.5 230 1.25 400 1.15 1.1 500 690 1 24 0.8 60 2 0.5 110 0.3 220 0.2 6 Fuses LV HRC Type 3NA, DIAZED Type 5SA/5SB, NEOZED Type 5SE: utilization category gL/gG 6 A Miniature circuit-breaker (C characteristic): 3 A -Ratings, main circuit Rated current Rated voltage a -, u -, r 400 at AC-15: V Short-circuit protection Equal potential (NO + NC connected as changeover contact) 690 6 Switching capacity Rated operational voltage Ue Rated operational current Ie a -, u -, r Unequal potential (NO + NC) NS1-5329 NC 1 NO + 1 NC NS1-5331 Conductor cross-sections Terminal screw solid or stranded mm2 finely stranded with end mm2 sleeve Tightening torque Nm lb. in NS1-5330 Auxiliary contacts A AC V 12 600 14.5 (25)1) 600 45 600 88 600 63 600 135 600 150/180 600 400 600 630 600 -Ratings, auxiliary circuit Rated voltage Switching capacity AC V 600, >150 same polarity B 600, R 300 Adapter for installing the relay as a single unit Type 3UX1 418 3UX1 420 3UX1 421 3UX1 424 3UX1 425 For overload relay 3UA50 3UA52 3UA58 3UA60 3UA55 Conductor cross-sections Terminal screw solid or stranded mm2 finely stranded with end sleeve mm2 M 3.5 1 to 4 M4 2.5 to 10 M6 2.5 to 35 M6 2×25 to 70 M5 1 to 25 0.75 to 2.5 1.5 to 6 1.5 to 25 2×25 to 50 1 to 16 Trip class A Tripping time tA in seconds at 7.2 ×Ie from cold state 10 10 20 30 2< 4< 6< 9< Trip classes of thermal, delayed magnetic or solid-state overload relays – Excerpt from IEC 947-4 1) Value in brackets only valid for 3UA52. tA tA tA tA ≤ 10 ≤ 10 ≤ 20 ≤ 30 3UA Thermally Delayed Overload Relays CLASS 10 Technical data according to IEC 947-4 and DIN VDE 0660 Part 102 Short circuit protection with fuses for motor feeders with short-circuit currents up to 50 kA at 690 V1), 50/60 Hz Overload relay Type Setting range A Permissible short-circuit fuses for motor starters consisting of overload relay and contactor, contactor assembly Fuse links LV HRC Type 3NA DIAZED Type 5SB NEOZED Type 5SE Utilization category gL/gG LV HRC Type 3ND Utilization category aM Type of coordination2) “1” “2” A A Type of coordination2) Type of coordination2) “2” “1” “2” A A A u -listed fuses CLASS R K5 British standards fuses BS 88 Type T Short-circuit protection with circuit breakers, fuseless motor feeders, combination of devices for mounting onto busbars, see "Circuit breakers" and "Fuseless load feeders". A 3UA70 21 0.1 – 0.16 0.16– 0.25 0.25– 0.4 25 25 25 0.5 slow3) 13) 1.63) – 25 25 25 0.4 – 0.63 0.63– 1 0.8 – 1.25 25 25 25 2 4 4 – 25 25 25 2 4 4 3 5 6 1 – 1.6 1.25– 2 1.6 – 2.5 25 25 25 6 6 6 – 25 25 25 6 6 10 8 10 12 2 – 3.2 2.5 – 4 3.2 – 5 25 25 25 10 10 10 – 25 25 25 10 10 10 12 12 12 4 – 6.3 5 – 8 6.3 –10 25 25 25 10 10 10 – 25 25 25 10 10 10 15 20 20 – 1 1 2 – 1 1 2 3UA50 0.1 – 0.16 0.16– 0.25 0.25– 0.4 35 35 35 0.5 slow3) 13) 1.63) – 25 25 25 0.4 – 0.63 0.63– 1 0.8 – 1.25 35 35 35 2 4 4 – 25 25 25 2 4 4 3 5 6 1 – 1.6 1.25– 2 1.6 – 2.5 35 35 35 6 6 6 – 25 25 25 6 6 10 8 10 12 2 – 3.2 2.5 – 4 3.2 – 5 35 35 35 10 10 16 – 25 25 25 10 10 16 12 12 12 4 – 6.3 5 – 8 6.3 –10 35 35 35 16 20 25 – 25 25 25 16 16 20 15 20 20 35 35 25 25 – 25 35 20 32 20 20 – 1 1 2 8 10 –12.5 –14.5 3UA52 0.1 – 0.16 0.16– 0.25 0.25– 0.4 63 63 63 0.5 slow3) 13) 1.63) – 63 63 63 0.4 – 0.63 0.63– 1 0.8 – 1.25 63 63 63 2 4 4 – 63 63 63 2 4 4 3 5 6 1 – 1.6 1.25– 2 1.6 – 2.5 63 63 63 6 6 6 – 63 63 63 6 6 10 8 10 12 2 – 3.2 2.5 – 4 3.2 – 5 63 63 63 10 10 16 – 63 63 63 10 10 16 12 12 12 4 – 6.3 5 – 8 6.3 –10 63 63 63 16 20 25 – 63 63 63 16 20 20 15 20 20 63 63 63 63 25 25 25 25 16 20 20 20 63 63 63 63 20 25 35 35 30 30 30 45 1 – 1.6 1.25– 2 1.6 – 2.5 80 80 80 6 6 6 – 100 100 100 6 6 10 8 10 12 2 – 3.2 2.5 – 4 3.2 – 5 80 80 80 10 10 16 – 100 100 100 10 10 16 12 12 15 4 – 6.3 5 – 8 6.3 –10 80 80 80 16 20 25 – 100 100 100 16 20 25 15 20 25 8 –12.5 10 –16 12.5 –20 80 80 80 25 35 50 16 20 20 100 100 100 20 40 50 25 40 50 16 20 25 –25 –32 –36 80 80 80 50 80 80 40 50 50 100 100 100 63 80 80 60 60 60 32 36 –40 –45 80 80 80 80 50 50 100 100 80 80 60 60 8 10 12.5 16 –12.5 –16 –20 –25 3UA55 1) Voltage tolerance +5%. 2) Coordination of short-circuit equipment according to IEC 947-4/DIN VDE 0660 Part 102: Type of coordination “1”: The contactor or starter must not endanger persons or the installation in the event of a short-circuit. They do not need to be suitable for further operation without repair and the renewal of parts. Type of coordination “2”: The contactor or starter must not endanger persons or the installation and must be suitable for further use.There is a danger of contact welding. 3) D-fuse links UN = 500 V, make SIBA. 3UA Thermally Delayed Overload Relays CLASS 10 Technical data according to IEC 947-4 and DIN VDE 0660 Part 102 Short-circuit protection with fuses for motor feeders with short-circuit currents up to 50 kA at 690 V1), 50/60 Hz Overload relay Type Permissible short-circuit fuses for motor starters consisting of overload relay and contactor, contactor assembly Setting range A Fuse links LV HRC Type 3NA DIAZED Type 5SB NEOZED Type 5SE Utilization category gL/gG LV HRC Type 3ND Utilization category aM Type of coordination3) “1” “2” A A Type of coordination3) Type of coordination3) “2” “1” “2” A A A u -listed fuses CLASS R K5 British standards fuses BS 88 Type T Short-circuit protection with circuit breakers, fuseless motor feeders, combination of devices for mounting onto busbars, see "Circuit breakers" and "Fuseless load feeders". A 3UA58 16 20 25 32 – – – – 25 32 40 50 160 160 160 160 50 63 80 125 25 35 40 50 160 160 160 160 63 63 80 80 60 70 70 70 40 50 57 63 70 – – – – – 57 63 70 80 88 160 160 160 250 250 125 125 125 160 160 63 63 63 80 100 160 160 160 160 160 100 100 100 125 125 70 100 125 150 175 3UA70 11, 3UA59 0.1 – 0.16– 0.25– 0.16 0.25 0.4 25 25 25 0.5 slow4) 14) 1.64) – 25 25 25 0.4 – 0.63– 0.8 – 0.63 1 1.25 25 25 25 2 4 4 – 25 25 25 2 4 4 3 5 6 1 – 1.25– 1.6 – 1.6 2 2.5 25 25 25 6 6 6 – 25 25 25 6 6 10 8 10 12 2 – 2.5 – 3.2 – 3.2 4 5 25 25 25 10 10 10 – 25 25 25 10 10 16 12 12 12 4 – 6.3 5 – 8 6.3 – 10 25 25 25 10 10 10 – 25 35 35 16 16 20 15 20 20 8 – 12.52) 10 – 16 12.5 – 20 35 63 63 16 25 25 – 16 20 63 63 63 32 32 35 20 30 45 – 1 1 2 16 20 25 – 25 – 32 – 40 63 80 125 25 63 80 25 35 40 80 80 160 50 63 80 45 60 70 32 40 50 – 45 – 57 – 63 160 160 160 100 125 125 50 63 63 160 160 160 80 100 100 70 100 100 3UA60, 3UA61, 3UA62 55 – 80 250 160 80 160 125 150 63 – 90 250 160 100 160 125 150 80 –110 400 200 125 315 160 175 90 –120 400 224 125 315 200 175 110 –135 400 224 160 315 200 175 120 –150 400 250 160 315 200 200 135 –160 400 250 160 355 250 200 150 –180 400 250 200 355 250 200 3UA66, 3UA68 80 –125 355 224 125 355 224 300 125 –200 355 224 200 355 224 300 160 –250 500 400 250 500 355 300 200 –320 500 400 315 500 400 300 250 –400 800 500 400 800 450 400 320 –500 800 500 630 800 500 400 –630 1000 500 (630)5) 630 1000 500 400 1200 CLASS L 1) Voltage tolerance +5%. 2) For 3UA70 11 setting range 8 to 12 A. 3) Coordination of short-circuit equipment according to IEC 947-4/DIN VDE 0660 Part 102: Type of coordination “1”: The contactor or starter must not endanger persons or the installation in the event of a short-circuit. They do not need to be suitable for further operation without repair and the renewal of parts. Type of coordination “2”: The contactor or starter must not endanger persons or the installation and must be suitable for further use.There is a danger of contact welding. 4) D-fuse links UN = 500 V, make SIBA. 5) Valid for 3TB contactor.