Bussmann® Specialty Fuse GMQ & HLQ Time-Delay, Rejection Style Dimensional Data FUSE 0.63" (15.9mm) FUSE AND CARRIER 57.15 2.250 Catalog Symbol: GMQ (Fuse) HLQ (Fuseholder) Time-Delay Rejection Style Fuse Ampere Rating: ⁄Ω™ to 6⁄Ω¢ Amperes Voltage Rating: 300 Volts AC or less Interrupting Rating: 10,000 Amperes Agency Approvals: Fuse: U.L. Listed, Guide JDYX, File E19180 CSA Certified, Class 1422-01, File 53787 Fuseholder: U.L. Recognized, Guide IZLT2, File E14853 CSA Certified, Class 6225-01, File 47235 18.29 .720 21.59 .850 22.10 .870 Knockout Hole Carrier Fuse Carrier GMQ-⁄Ω™ HLQ-⁄Ω™ GMQ-2⁄Ω™ HLQ-3¤Ω¡º GMQ-flΩ¡º HLQ-1flΩ¡º GMQ-3 HLQ-3¤Ω¡º GMQ-°Ω¡º HLQ-1flΩ¡º GMQ-3¤Ω¡º HLQ-3¤Ω¡º GMQ-1 HLQ-1flΩ¡º GMQ-4 HLQ-5 GMQ-1⁄Ω¢ HLQ-1flΩ¡º GMQ-5 HLQ-5 GMQ-1flΩ¡º HLQ-1flΩ¡º GMQ-6⁄Ω¢ HLQ-8 GMQ-2 HLQ-3¤Ω¡º — — CE logo denotes compliance with European Union Low Voltage Directive (50-1000 Vac, 75-1500 Vdc). Refer to BIF document #8002 or contact Bussmann Application Engineering at 314-527-1270 for more information. 6.48 .255 16.13 .635 18.80 .740 Fuse Rev. A C L MOUNTING HOLE Electrical Ratings for Type GMQ Fuses and Rejection Style Carriers 12-18-98 SB98107 21.59 .850 10.41 .410 Keyhole Punch General Information: • HLQ carrier comes with 6∑ of #18 red insulated solid copper wire attached to the line side. • Customer inserts a #18 insulated solid copper wire into load side receptacle. • Size of type GMQ fuses varies with ampere ratings. • Mounts in type HLQ size rejection (size limiting) carrier (prevents overfusing). • Fuse and knob are an integral one-piece unit. There are no replacement knobs (caps). • Units can be panel-mounted with a separate steel clip (BK/A-104). Form No. GMQ Page 1 of 2 BIF Doc #2030 Bussmann® Specialty Fuse GMQ & HLQ Time-Delay, Rejection Style Time-Current Characteristic Curves–Average Melt AMPERE RATING 100 AMPERE RATING 10 200 .1 1 CURRENT IN AMPERES 200 .01 100 .01 10 .1 .1 .1 100 1 10 1 1 TIME IN SECONDS 10 TIME IN SECONDS 5 7 3 3.2 4 1 1.6 2 .5 .3 100 .2 Time-Current Characteristic Curves–Average Melt CURRENT IN AMPERES The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 12-18-98 SB98107 Rev. A Form No. GMQ Page 2 of 2 BIF Doc #2030