ETC HFA35HB120C

PD - 20371D
HFA35HB120C
Ultrafast, Soft Recovery Diode
FRED
Features
•
•
•
•
•
VR = 1200V
Reduced RFI and EMI
Reduced Snubbing
Extensive Characterization of Recovery Parameters
Hermetic
Ceramic Eyelets
IF(AV) = 15A
Qrr = 370ns
Description
These Ultrafast, soft recovery diodes are optimized to reduce losses and EMI/RFI in high frequency power
conditioning systems. An extensive characterization of the recovery behavior for different values of current,
temperature and di/dt simplifies the calculations of losses in the operating conditions. The softness of the recovery
eliminates the need for a snubber in most applications. These devices are ideally suited for power converters, motors
drives and other applications where switching losses are significant portion of the total losses.
Absolute Maximum Ratings
Parameter
VR
IF(AV)
IFSM
PD @ TC = 25°C
TJ, TSTG
Cathode to Anode Voltage ( Per Leg )
Continuous Forward Current, Q TC =100 °C
Single Pulse Forward Current, R TC = 25°C ( Per Leg )
Maximum Power Dissipation
Operating Junction and Storage Temperature Range
Max.
Units
1200
15
80
63
-55 to +150
V
A
W
°C
Note: Q D.C. = 50% rect. wave
R 1/2 sine wave, 60 Hz , P.W. = 8.33 ms
CASE STYLE
(ISOLATED BASE)
ANODE
TO-254AA
www.irf.com
COMMON
CATHODE
ANODE
1
08/29/02
HFA35HB120C
Electrical Characteristics (Per Leg) @ TJ = 25°C (unless otherwise specified)
Parameter
VBR
VFM
IRM
CT
LS
Cathode Anode Breakdown Voltage
Max Forward Voltage
See Fig. 1
Max Reverse Leakage Current
See Fig. 2
Junction Capacitance, See Fig. 3
Series Inductance
Min. Typ. Max. Units
1200 —
—
—
—
—
—
—
—
—
—
—
—
10
—
8.7
—
3.3
4.4
2.8
10
1.0
15
—
V
V
µA
mA
pF
nH
Test Conditions
IR = 250µA
IF = 7.0A
IF = 15A
IF = 7.0A, TJ = 125°C
VR = VR Rated
VR = VR Rated, TJ = 125°C
VR = 200V
Measured from anode lead to cathode
lead, 6mm ( 0.025 in) from package
Dynamic Recovery Characteristics (Per Leg) @ TJ = 25°C (unless otherwise specified)
Parameter
trr1
trr2
IRRM1
IRRM2
Q rr1
Q rr2
di(rec)M/dt1
di(rec)M/dt2
Reverse Recovery Time
Peak Recovery Current
Reverse Recovery Charge
Peak Rate of Fall of Recovery Current
During tb
Min. Typ. Max. Units
—
—
—
—
—
—
—
—
58
110
5.4
7.2
185
395
255
160
100
165
8.1
10.8
370
590
380
240
Test Conditions
ns
TJ = 25°C See Fig.
TJ = 125°C
5
IF = 7A
TJ = 25°C See Fig.
A
TJ = 125°C
6
VR = 200V
TJ = 25°C See Fig.
nC
TJ = 125°C
7
dif/dt = 200A/µs
TJ = 25°C See Fig.
A/µs
TJ = 125°C
8
Thermal - Mechanical Characteristics
Parameter
RthJC
Wt
2
Junction-to-Case, Single Leg Conducting
Weight
Typ.
Max.
Units
—
9.3
2.0
—
°C/W
g
www.irf.com
HFA35HB120C
R e ve rse C u rre n t - I R (µ A )
1000
TJ = 150°C
TJ = 125°C
TJ = 25°C
TJ = 15 0°C
100
TJ = 1 25°C
10
1
0.1
T = 2 5 °C
J
0.01
0.001
0
10
300
600
900
1200
R e ve rse V o lta g e - V R (V )
Fig. 2 - Typical Reverse Current Vs. Reverse
Voltage ( Per Leg )
Ju n c tio n C a p a c itan ce - C T (p F )
In sta n ta n e o u s F o rw a rd C u rre n t - I F (A )
100
1
1.0
3.0
5.0
7.0
F o rw a rd V o lta g e D ro p - V FM (V )
100
A
TJ = 2 5 °C
10
1
1
10
Fig. 1 - Maximum Forward Voltage Drop Vs.
Instantaneous Forward Current ( Per Leg )
100
1000
R e ve rse V o lta g e - V R (V )
Fig. 3 - Typical Junction Capacitance Vs.
Reverse Voltage ( Per Leg )
Thermal Response (Z thJC )
10
1
D = 0.50
0.20
0.10
PDM
0.05
0.1
0.01
0.00001
0.02
0.01
t1
SINGLE PULSE
(THERMAL RESPONSE)
t2
Notes:
1. Duty factor D = t 1 / t 2
2. Peak TJ = P DM x Z thJC + TC
0.0001
0.001
0.01
0.1
1
t1 , Rectangular Pulse Duration (sec)
Fig. 4 - Maximum Thermal Impedance Zthjc Characteristics ( Per Leg )
www.irf.com
3
HFA35HB120C
150
100
IF = 1 4 A
IF = 7 A
I F = 3 .5 A
120
IF = 14A
- (A )
90
IRRM
trr - (n s)
IF = 7 A
I F = 3 .5 A
10
60
30
VR = 2 0 0 V
T J = 1 2 5 °C
T J = 2 5 °C
VR = 2 0 0 V
T J = 1 2 5 °C
T J = 2 5 °C
0
100
1
100
1000
d i f /d t - (A /µ s )
Fig. 5 - Typical Reverse Recovery vs. dif/dt
1000
d i f /d t - (A /µ s)
Fig. 6 - Typical Recovery Current vs. dif/dt
1000
10000
d i(re c )M /d t - (A /µ s )
R R - (n C )
Qrr-Q(nC)
I F = 3 .5 A
100
IF = 1 4 A
IF = 7 A
I F = 3 .5 A
1000
IF = 7A
100
IF = 1 4 A
VR = 2 0 0 V
T J = 1 2 5 °C
T J = 2 5 °C
10
100
VR = 2 0 0 V
TJ = 1 2 5 °C
TJ = 2 5 °C
d i f /d t - (A /µ s)
1000
Fig. 7 - Typical Stored Charge vs. dif/dt
4
10
100
1000
d i f /d t - (A /µ s)
Fig. 8 - Typical di(rec)M/dt vs. dif/dt
www.irf.com
HFA35HB120C
3
t rr
IF
tb
ta
0
R E V E R S E R E C O V E R Y C IR C U IT
Q rr
V R = 2 00 V
2
I RRM
0.5 I R R M
di(rec)M /dt
0.01 Ω
5
0.75 I R R M
L = 70µH
D .U .T.
1
D
d if/d t
A D JU S T
4
IR F P 2 50
G
di f /dt
1. dif/dt - Rate of change of current
through zero crossing
2. IRRM - Peak reverse recovery current
S
3. trr - Reverse recovery time measured
from zero crossing point of negative
going IF to point where a line passing
through 0.75 IRRM and 0.50 IRRM
extrapolated to zero current
Fig. 9 - Reverse Recovery Parameter Test Circuit
4. Qrr - Area under curve defined by trr
and IRRM
trr X IRRM
Qrr =
2
5. di(rec)M/dt - Peak rate of change of
current during tb portion of trr
Fig. 10 - Reverse Recovery Waveform and Definitions
Case Outline and Dimensions — TO-254AA
0.12 [.005]
6.60 [.260]
6.32 [.249]
13.84 [.545]
13.59 [.535]
3.78 [.149]
3.53 [.139]
1.27 [.050]
1.02 [.040]
A
20.32 [.800]
20.07 [.790]
17.40 [.685]
16.89 [.665]
1
C
2
B
13.84 [.545]
13.59 [.535]
3
17.40 [.685]
16.89 [.665]
0.84 [.033]
MAX.
1.14 [.045]
0.89 [.035]
3X
3.81 [.150]
0.36 [.014]
2X
2X
NOT ES :
1. DIMENSIONING & T OLERANCING PER ASME Y14.5M-1994.
2. ALL DIMENSIONS ARE S HOWN IN MILLIMET ERS [INCHES ].
3. CONT ROLLING DIMENS ION: INCH.
4. CONFORMS TO JEDEC OUTLINE TO-254AA.
3.81 [.150]
B A
PIN AS S IGNMENTS
PIN ASS IGNMENTS
DRAIN1
11==ANODE
2 = COMMON CATHODE
3 = ANODE 2
IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105
TAC Fax: (310) 252-7903
Visit us at www.irf.com for sales contact information.
Data and specifications subject to change without notice. 08/02
www.irf.com
5