DUAL POLE OptoMOS® RELAYS LAA110/LAA110L DESCRIPTION LAA110 is a 350V, 120mA, 35Ω 2-Form-A relay. It provides an integrated solution to fit most applications where two Form-A relays are required. Current limiting version is available (“L” suffix, see specification for variations in performance). FEATURES APPLICATIONS ■ Small 8 Pin DIP Package ■ Low Drive Power Requirements (TTL/CMOS ■ Telecommunications ■ ■ ■ ■ ■ ■ ■ ■ ■ Compatible) No Moving Parts High Reliability Arc-Free With No Snubbing Circuits 3750VRMS Input/Output Isolation FCC Compatible VDE Compatible No EMI/RFI Generation Machine Insertable, Wave Solderable Current Limiting, Surface Mount and Tape & Reel Versions Available APPROVALS ■ UL Recognized: File Number E76270 ■ CSA Certified: File Number LR 43639-10 ■ BSI Certified to: ■ ■ BS EN 60950:1992 (BS7002:1992) Certificate #: 7344 BS EN 41003:1993 Certificate #: 7344 P: Flatpack Package L: Current Limiting S: Surface Mount Package TR: Tape & Reel 10ms ■ ■ ■ RATINGS (@ 25˚ C) Parameter + 90% 10%+ 10%+ TOFF Min Typ Max Units - - 1501 50 1 mW mA A Reverse Input Voltage - - 5 V Total Power Dissipation - - 8002 mW - 3 - pF VRMS 3750 - - Operational Temperature -40 - +85 ° C Storage Temperature -40 - +125 ° C - - +260 ° C - - +220 ° C Soldering Temperature DIP Package Flatpack/Surface Mount Package (10 Seconds Max.) CONTROL TON ■ Capacitance Input to Output Isolation Voltage Input to Output Switching Characteristics of Normally Open (Form A) Devices LOAD ■ ■ Input Power Dissipation Input Control Current Peak (10ms) OPTIONS / SUFFIXES ■ ■ ■ ■ Telecom Switching Tip/Ring Circuits Modem Switching (Laptop, Notebook, Pocket Size) ■ Hookswitch ■ Dial Pulsing ■ Ground Start ■ Ringer Injection Instrumentation ■ Multiplexers ■ Data Acquisition ■ Electronic Switching ■ I/O Subsystems ■ Meters (Watt-Hour, Water, Gas) ■ Medical Equipment-Patient/Equipment Isolation Security Aerospace Industrial Controls ■ 1 2 Derate Linearly 1.33 mw/˚C Derate Linearly 6.67 mw/˚C Note: For Mechanical Dimensions See Pages 408-415 North America: 1-800-272-5273 Europe: 32-11-300868 146 Powered by ICminer.com Electronic-Library Service CopyRight 2003 Asia: 886-2-2523-6368 Japan: 03-3980-2212 DUAL POLE OptoMOS® RELAYS LAA110/LAA110L SPECIFICATIONS LAA110 PARAMETER Output Characteristics @ LAA110L CONDITIONS SYMBOL MIN TYP MAX MIN TYP MAX UNITS - VL - - 350 - - 350 V 25°C Load Voltage (Peak) Load Current (Continuous) AC/DC Configuration - IL - - 120 - - 120 mA Peak Load Current 10ms max ILPK - - 350 - - - mA On-Resistance AC/DC Configuration IL=120mA RON - 25 35 - 30 35 Ω Off-State Leakage Current VL=350V ILEAK - - 1 - - 1 µA IF=5mA, VL=10V IF=5mA, VL=10V TON TOFF - - 3 3 - - 3 3 ms ms 50V; f=1MHz COUT - 25 - - 25 - pF ICL - - - 130 170 210 mA Switching Speeds Turn-On Turn-Off Output Capacitance Load Current Limiting Input Characteristics @ 25°C Input Control Current IL=120mA IF 5 - 50 5 - 50 mA Input Dropout Current - - 0.4 0.7 - 0.4 0.7 - mA Input Voltage Drop IF=5mA VF 0.9 1.2 1.4 0.9 1.2 1.4 V Reverse Input Voltage - VR - - 5 - - 5 V Reverse Input Current VR=5V IR - - 10 - - 10 µA Input to Output Capacitance - CI/O - 3 - - 3 - pF Input to Output Isolation - VI/O 3750 - - 3750 - - VRM LAA110 Pinout LAA110L Pinout AC/DC Configuration + Control - Switch #1 – Control - Switch #1 + Control - Switch #2 – Control - Switch #2 AC/DC Configuration 1 8 2 7 3 6 4 5 Load - Switch #1 + Control - Switch #1 Load - Switch #1 – Control - Switch #1 Load - Switch #2 + Control - Switch #2 Load - Switch #2 – Control - Switch #2 1 8 2 7 3 6 4 5 Load - Switch #1 Load - Switch #1 Load - Switch #2 Load - Switch #2 Note: For Mechanical Dimensions See Pages 408-415 www.clare.com 147 Powered by ICminer.com Electronic-Library Service CopyRight 2003 DUAL POLE OptoMOS® RELAYS LAA110/LAA110L PERFORMANCE DATA LAA110 Typical LED Forward Voltage Drop (N=50 Ambient Temperature = 25°C) IF = 5mADC 35 LAA110 Typical On-Resistance Distribution (N=50 Ambient Temperature = 25°C) (Load Current = 120mADC) 35 35 30 25 20 15 10 5 30 25 Device Count (N) Device Count (N) 20 15 10 5 0 1.19 1.21 1.23 1.25 15 10 5 0 1.43 1.69 Blocking Voltage (V) LAA110 Typical Turn-On Time (N=50 Ambient Temperature = 25°C) (Load Current = 120mADC; IF = 5mADC) 25 25 20 20 Device Count (N) Device Count (N) Device Count (N) 20 1.17 15 10 5 0.39 0.65 0.91 1.17 1.43 1.69 Load Current (mA) 20 15 10 5 0.15 0 0.035 0.105 0.175 0.245 0.315 0.385 0.455 180 0.016 160 0.014 140 0.012 120 100 20mA 10mA 5mA 80 60 0.008 0.006 -20 0 20 40 60 80 100 -40 120 -20 0 405 400 395 60 80 100 5mA 10mA 20mA -40 -20 0 Temperature (°C) North America: 1-800-272-5273 20 40 60 80 100 Temperature (°C) Europe: 32-11-300868 148 Powered by ICminer.com Electronic-Library Service CopyRight 2003 40 60 80 100 LAA110 Typical Turn-Off vs. Temperature (Load Current = 120mA) Asia: 886-2-2523-6368 Turn-Off (ms) Turn-On (ms) 410 5.000 4.500 4.000 3.500 3.000 2.500 2.000 1.500 1.000 0.500 0 20 Temperature (°C) LAA110 Typical Turn-On vs. Temperature (Load Current = 120mADC) 415 1.95 0 LAA110 Typical Blocking Voltage vs. Temperature 420 1.65 0.010 Temperature (°C) 425 1.35 0.002 -40 430 1.05 0.004 40 Turn-Off (ms) Blocking Voltage (VRMS) 0.75 LAA110 Typical Leakage vs. Temperature (Measured across Pins 5 & 6 or 7 & 8) 0 40 0.45 Turn-On (ms) 20 20 5 1.95 LAA110 Typical Load Current vs. Temperature 25 0 10 LED Current (mA) LAA110 Typical Turn-Off Time (N=50 Ambient Temperature = 25°C) (Load Current = 120mADC; IF = 5mADC) -20 15 0 0 1.95 LED Current (mA) -40 10 377.5 388.5 399.5 410.5 421.5 432.5 443.5 LAA110 Typical IF for Switch Dropout (N=50 Ambient Temperature = 25°C) (Load Current = 120mADC) 25 0.91 15 On-Resistance (Ω) LAA110 Typical IF for Switch Operation (N=50 Ambient Temperature = 25°C) (Load Current = 120mADC) 0.65 20 0 18.75 19.85 20.95 22.05 23.15 24.25 25.35 LED Forward Voltage Drop (V) 0.39 25 5 0 1.17 Leakage (µA) Device Count (N) 30 Device Count (N) LAA110 Typical Blocking Voltage Distribution (N=50 Ambient Temperature = 25°C) 1.000 0.900 0.800 0.700 0.600 0.500 0.400 0.300 0.200 0.100 0 5mA -40 -20 0 20 40 60 Temperature (°C) Japan: 03-3980-2212 80 100 DUAL POLE OptoMOS® RELAYS LAA110/LAA110L PERFORMANCE DATA LAA110 Typical Turn-On vs. LED Forward Current (Load Current = 120mADC) 1.6 1.4 50mA 30mA 20mA 10mA 5mA 1.2 1.0 0.8 -40 -20 0 20 40 60 80 100 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 120 0.7 0.6 0.4 0.3 0.2 0 0 5 0 10 15 20 25 30 35 40 45 50 LAA110 Typical IF for Switch Operation vs. Temperature (Load Current = 120mADC) 2.500 30 20 2.000 1.500 1.000 10 0.500 0 0 0 20 40 60 80 Load Current (A) 0 -50 -100 -150 -3 -2 -1 0 1 2 3 Load Voltage (V) 30 35 40 45 50 2.000 1.500 1.000 0 20 40 60 80 100 -40 -20 0 20 40 60 80 100 Temperature (°C) LAA110 Energy Rating Curve 100 50 25 0 -20 Temperature (°C) LAA110 Typical Load Current vs. Load Voltage (Ambient Temperature = 25°C) IF = 5mADC 20 0.500 -40 100 Temperature (°C) 150 LED Current (mA) 3.000 2.500 LED Current (mA) 3.000 40 15 LAA110 Typical IF for Switch Dropout vs. Temperature (Load Current = 120mADC) 50 -20 10 LED Forward Current (mA) 60 -40 5 LED Forward Current (mA) LAA110 Typical On-Resistance vs. Temperature (Load Current = 120mADC; IF = 5mADC) On-Resistance (Ω) 0.5 0.1 Temperature (°C) Load Current (mA) LAA110 Typical Turn-Off vs. LED Forward Current (Load Current = 120mADC) Turn-Off (ms) 1.8 Turn-On (ms) LED Forward Voltage Drop (V) LAA110 Typical LED Forward Voltage Drop vs. Temperature 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 10µs 100µs 1ms 10ms 100ms 1s 10s 100s Time www.clare.com 149 Powered by ICminer.com Electronic-Library Service CopyRight 2003 DUAL POLE OptoMOS® RELAYS LAA110/LAA110L PERFORMANCE DATA LAA110L Typical On-Resistance Distribution (N=50 Ambient Temperature = 25°C) (Load Current = 120mADC; IF = 5mADC) Device Count (N) Device Count (N) 30 25 20 15 10 35 35 30 30 25 20 15 10 5 5 0 0 1.17 1.19 1.21 1.23 15 10 17.0 17.4 17.8 18.2 18.6 19.0 19.4 376.3 382.8 389.3 395.8 402.3 408.8 415.3 On-Resistance (Ω) Blocking Voltage (V) LAA110L Typical IF for Switch Dropout (N=50 Ambient Temperature = 25°C) (Load Current = 120mADC) LAA110L Typical Turn-On Time (N=50 Ambient Temperature = 25°C) (Load Current = 120mADC; IF = 5mADC) 25 20 20 20 15 10 15 10 5 5 0 0 0.75 1.05 1.35 1.65 1.95 Device Count (N) 25 Device Count (N) 25 0.45 0.75 1.05 1.35 1.65 1.95 2.25 0.15 5 100 20mA 10mA 5mA 80 60 40 0.225 LAA110L Typical Blocking Voltage vs. Temperature 0 20 380 40 60 80 120 0 20 40 60 80 100 0 20 40 60 80 100 LAA110L Typical Turn-Off vs. Temperature (Load Current = 120mADC) 1.600 0.700 1.400 0.600 1.200 0.500 1.000 0.800 0.600 5mA 10mA 20mA 0.400 0.300 0.200 0.100 5mA 0 -40 -20 0 Temperature (°C) North America: 1-800-272-5273 -20 LAA110L Typical Turn-On vs. Temperature (Load Current = 120mADC) 0 -20 -40 Temperature (°C) 0.200 360 0.004 Temperature (°C) 0.400 370 100 Turn-Off (ms) Turn-On (ms) 390 0.006 0 -20 Turn-Off (ms) 400 0.01 0.008 0.002 -40 410 0.65 0.012 120 0 420 0.55 140 20 0 0.45 0.014 Leakage (µA) 10 -40 0.35 LAA110L Typical Leakage vs. Temperature (Measured across Pins 5 & 6 or 7 & 8) 180 Load Current (mA) 15 0.175 0.25 Turn-On (ms) 160 20 0.125 5 LAA110L Typical Load Current vs. Temperature 25 0.075 10 LED Current (mA) LAA110L Typical Turn-Off Time (N=50 Ambient Temperature = 25°C) (Load Current = 120mADC; IF = 5mADC) 0.025 15 0 0.45 2.25 LED Current (mA) Device Count (N) 20 0 1.25 LAA110L Typical IF for Switch Operation (N=50 Ambient Temperature = 25°C) (Load Current = 120mADC) Blocking Voltage (VRMS) 25 5 LED Forward Voltage Drop (V) Device Count (N) LAA110L Typical Blocking Voltage Distribution (N=50 Ambient Temperature = 25°C) Device Count (N) 35 LAA110L Typical LED Forward Voltage Drop (N=50 Ambient Temperature = 25°C) IF = 5mADC 20 40 60 80 100 Temperature (°C) Europe: 32-11-300868 150 Powered by ICminer.com Electronic-Library Service CopyRight 2003 Asia: 886-2-2523-6368 -40 -20 0 20 40 60 Temperature (°C) Japan: 03-3980-2212 80 100 DUAL POLE OptoMOS® RELAYS LAA110/LAA110L PERFORMANCE DATA LAA110L Typical Turn-On vs. LED Forward Current (Load Current = 120mADC) 1.6 1.4 50mA 30mA 20mA 10mA 5mA 1.2 1.0 0.9 0.40 0.8 0.35 0.7 0.30 0.6 0.5 0.4 0.3 -20 0 20 40 60 80 100 0.25 0.20 0.15 0.2 0.10 0.1 0.05 0 0.8 -40 0 0 120 5 10 15 20 25 30 35 40 45 0 50 3.000 20.000 2.500 2.000 1.500 1.000 10.000 0.500 0 0 -20 0 20 40 60 80 Load Current (A) Load Current (mA) 0 -50 -100 -150 -4 -3 -2 -1 0 1 2 3 4 Load Voltage (V) 30 35 40 45 50 2.500 2.000 1.500 1.000 0 20 40 60 80 100 -40 -20 0 20 40 60 80 100 Temperature (°C) LAA110L Energy Rating Curve 100 50 25 0 -20 Temperature (°C) LAA110L Typical Load Current vs. Load Voltage (Ambient Temperature = 25°C) IF = 5mADC 20 0.500 -40 100 Temperature (°C) 150 LED Current (mA) 3.500 3.000 Current (mA) 3.500 50.000 30.000 15 LAA110L Typical IF for Switch Dropout vs. Temperature (Load Current = 120mADC) 60.000 40.000 10 LED Forward Current (mA) LAA110L Typical IF for Switch Operation vs. Temperature (Load Current = 120mADC) LAA110L Typical On-Resistance vs. Temperature (Load Current = 120mADC; IF = 5mADC) -40 5 LED Forward Current (mA) Temperature (°C) On-Resistance (Ω) LAA110L Typical Turn-Off vs. LED Forward Current (Load Current = 120mADC) Turn-Off (ms) 1.8 Turn-On (ms) LED Forward Voltage Drop (V) LAA110L Typical LED Forward Voltage Drop vs. Temperature 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 10µs 100µs 1ms 10ms 100ms 1s 10s 100s Time www.clare.com 151 Powered by ICminer.com Electronic-Library Service CopyRight 2003