DESCRIPTION
LAA110 is a 350V, 120mA, 35Ω 2-Form-A relay. It
provides an integrated solution to fit most applications
where two Form-A relays are required. Current limiting
version is available (“L” suffix, see specification for
variations in performance).
FEATURES
APPLICATIONS
■ Small 8 Pin DIP Package
■ Low Drive Power Requirements (TTL/CMOS
■ Telecommunications
■
■
■
■
■
■
■
■
■
Compatible)
No Moving Parts
High Reliability
Arc-Free With No Snubbing Circuits
3750VRMS Input/Output Isolation
FCC Compatible
VDE Compatible
No EMI/RFI Generation
Machine Insertable, Wave Solderable
Current Limiting, Surface Mount and Tape & Reel
Versions Available
APPROVALS
■ UL Recognized: File Number E76270
■ CSA Certified: File Number LR 43639-10
■ BSI Certified to:
■
■
BS EN 60950:1992 (BS7002:1992)
Certificate #: 7344
BS EN 41003:1993
Certificate #: 7344
P: Flatpack Package
L: Current Limiting
S: Surface Mount Package
TR: Tape & Reel
10ms
■
■
■
RATINGS (@ 25˚ C)
Parameter
+
90%
10%+
10%+
TOFF
Min
Typ
Max
Units
-
-
1501
50
1
mW
mA
A
Reverse Input Voltage
-
-
5
V
Total Power Dissipation
-
-
8002
mW
-
3
-
pF
VRMS
3750
-
-
Operational Temperature
-40
-
+85
°
C
Storage Temperature
-40
-
+125
°
C
-
-
+260
°
C
-
-
+220
°
C
Soldering Temperature
DIP Package
Flatpack/Surface Mount
Package
(10 Seconds Max.)
CONTROL
TON
■
Capacitance
Input to Output
Isolation Voltage
Input to Output
Switching Characteristics of
Normally Open (Form A) Devices
LOAD
■
■
Input Power Dissipation
Input Control Current
Peak (10ms)
OPTIONS / SUFFIXES
■
■
■
■
Telecom Switching
Tip/Ring Circuits
Modem Switching (Laptop, Notebook, Pocket Size)
■ Hookswitch
■ Dial Pulsing
■ Ground Start
■ Ringer Injection
Instrumentation
■ Multiplexers
■ Data Acquisition
■ Electronic Switching
■ I/O Subsystems
■ Meters (Watt-Hour, Water, Gas)
■ Medical Equipment-Patient/Equipment Isolation
Security
Aerospace
Industrial Controls
■
1
2
Derate Linearly 1.33 mw/˚C
Derate Linearly 6.67 mw/˚C
Note: For Mechanical Dimensions See Pages 408-415
North America: 1-800-272-5273
Europe: 32-11-300868
146
Powered by ICminer.com Electronic-Library Service CopyRight 2003
Asia: 886-2-2523-6368
Japan: 03-3980-2212
DUAL POLE OptoMOS® RELAYS
LAA110/LAA110L
SPECIFICATIONS
LAA110
PARAMETER
Output Characteristics @
LAA110L
CONDITIONS
SYMBOL
MIN
TYP
MAX
MIN
TYP
MAX
UNITS
-
VL
-
-
350
-
-
350
V
25°C
Load Voltage (Peak)
Load Current (Continuous)
AC/DC Configuration
-
IL
-
-
120
-
-
120
mA
Peak Load Current
10ms max
ILPK
-
-
350
-
-
-
mA
On-Resistance
AC/DC Configuration
IL=120mA
RON
-
25
35
-
30
35
Ω
Off-State Leakage Current
VL=350V
ILEAK
-
-
1
-
-
1
µA
IF=5mA, VL=10V
IF=5mA, VL=10V
TON
TOFF
-
-
3
3
-
-
3
3
ms
ms
50V; f=1MHz
COUT
-
25
-
-
25
-
pF
ICL
-
-
-
130
170
210
mA
Switching Speeds
Turn-On
Turn-Off
Output Capacitance
Load Current Limiting
Input Characteristics @ 25°C
Input Control Current
IL=120mA
IF
5
-
50
5
-
50
mA
Input Dropout Current
-
-
0.4
0.7
-
0.4
0.7
-
mA
Input Voltage Drop
IF=5mA
VF
0.9
1.2
1.4
0.9
1.2
1.4
V
Reverse Input Voltage
-
VR
-
-
5
-
-
5
V
Reverse Input Current
VR=5V
IR
-
-
10
-
-
10
µA
Input to Output Capacitance
-
CI/O
-
3
-
-
3
-
pF
Input to Output Isolation
-
VI/O
3750
-
-
3750
-
-
VRM
LAA110 Pinout
LAA110L Pinout
AC/DC Configuration
+ Control - Switch #1
– Control - Switch #1
+ Control - Switch #2
– Control - Switch #2
AC/DC Configuration
1
8
2
7
3
6
4
5
Load - Switch #1
+ Control - Switch #1
Load - Switch #1
– Control - Switch #1
Load - Switch #2
+ Control - Switch #2
Load - Switch #2
– Control - Switch #2
1
8
2
7
3
6
4
5
Load - Switch #1
Load - Switch #1
Load - Switch #2
Load - Switch #2
Note: For Mechanical Dimensions See Pages 408-415
www.clare.com
147
Powered by ICminer.com Electronic-Library Service CopyRight 2003
DUAL POLE OptoMOS® RELAYS
LAA110/LAA110L
PERFORMANCE DATA
LAA110
Typical LED Forward Voltage Drop
(N=50 Ambient Temperature = 25°C)
IF = 5mADC
35
LAA110
Typical On-Resistance Distribution
(N=50 Ambient Temperature = 25°C)
(Load Current = 120mADC)
35
35
30
25
20
15
10
5
30
25
Device Count (N)
Device Count (N)
20
15
10
5
0
1.19
1.21
1.23
1.25
15
10
5
0
1.43
1.69
Blocking Voltage (V)
LAA110
Typical Turn-On Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 120mADC; IF = 5mADC)
25
25
20
20
Device Count (N)
Device Count (N)
Device Count (N)
20
1.17
15
10
5
0.39
0.65
0.91
1.17
1.43
1.69
Load Current (mA)
20
15
10
5
0.15
0
0.035 0.105 0.175 0.245 0.315 0.385 0.455
180
0.016
160
0.014
140
0.012
120
100
20mA
10mA
5mA
80
60
0.008
0.006
-20
0
20
40
60
80
100
-40
120
-20
0
405
400
395
60
80
100
5mA
10mA
20mA
-40
-20
0
Temperature (°C)
North America: 1-800-272-5273
20
40
60
80
100
Temperature (°C)
Europe: 32-11-300868
148
Powered by ICminer.com Electronic-Library Service CopyRight 2003
40
60
80
100
LAA110
Typical Turn-Off vs. Temperature
(Load Current = 120mA)
Asia: 886-2-2523-6368
Turn-Off (ms)
Turn-On (ms)
410
5.000
4.500
4.000
3.500
3.000
2.500
2.000
1.500
1.000
0.500
0
20
Temperature (°C)
LAA110
Typical Turn-On vs. Temperature
(Load Current = 120mADC)
415
1.95
0
LAA110
Typical Blocking Voltage
vs. Temperature
420
1.65
0.010
Temperature (°C)
425
1.35
0.002
-40
430
1.05
0.004
40
Turn-Off (ms)
Blocking Voltage (VRMS)
0.75
LAA110
Typical Leakage vs. Temperature
(Measured across Pins 5 & 6 or 7 & 8)
0
40
0.45
Turn-On (ms)
20
20
5
1.95
LAA110
Typical Load Current vs. Temperature
25
0
10
LED Current (mA)
LAA110
Typical Turn-Off Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 120mADC; IF = 5mADC)
-20
15
0
0
1.95
LED Current (mA)
-40
10
377.5 388.5 399.5 410.5 421.5 432.5 443.5
LAA110
Typical IF for Switch Dropout
(N=50 Ambient Temperature = 25°C)
(Load Current = 120mADC)
25
0.91
15
On-Resistance (Ω)
LAA110
Typical IF for Switch Operation
(N=50 Ambient Temperature = 25°C)
(Load Current = 120mADC)
0.65
20
0
18.75 19.85 20.95 22.05 23.15 24.25 25.35
LED Forward Voltage Drop (V)
0.39
25
5
0
1.17
Leakage (µA)
Device Count (N)
30
Device Count (N)
LAA110
Typical Blocking Voltage Distribution
(N=50 Ambient Temperature = 25°C)
1.000
0.900
0.800
0.700
0.600
0.500
0.400
0.300
0.200
0.100
0
5mA
-40
-20
0
20
40
60
Temperature (°C)
Japan: 03-3980-2212
80
100
DUAL POLE OptoMOS® RELAYS
LAA110/LAA110L
PERFORMANCE DATA
LAA110
Typical Turn-On vs. LED Forward Current
(Load Current = 120mADC)
1.6
1.4
50mA
30mA
20mA
10mA
5mA
1.2
1.0
0.8
-40
-20
0
20
40
60
80
100
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
120
0.7
0.6
0.4
0.3
0.2
0
0
5
0
10 15 20 25 30 35 40 45 50
LAA110
Typical IF for Switch Operation
vs. Temperature
(Load Current = 120mADC)
2.500
30
20
2.000
1.500
1.000
10
0.500
0
0
0
20
40
60
80
Load Current (A)
0
-50
-100
-150
-3
-2
-1
0
1
2
3
Load Voltage (V)
30
35
40
45
50
2.000
1.500
1.000
0
20
40
60
80
100
-40
-20
0
20
40
60
80
100
Temperature (°C)
LAA110
Energy Rating Curve
100
50
25
0
-20
Temperature (°C)
LAA110
Typical Load Current vs. Load Voltage
(Ambient Temperature = 25°C)
IF = 5mADC
20
0.500
-40
100
Temperature (°C)
150
LED Current (mA)
3.000
2.500
LED Current (mA)
3.000
40
15
LAA110
Typical IF for Switch Dropout
vs. Temperature
(Load Current = 120mADC)
50
-20
10
LED Forward Current (mA)
60
-40
5
LED Forward Current (mA)
LAA110
Typical On-Resistance vs. Temperature
(Load Current = 120mADC; IF = 5mADC)
On-Resistance (Ω)
0.5
0.1
Temperature (°C)
Load Current (mA)
LAA110
Typical Turn-Off vs. LED Forward Current
(Load Current = 120mADC)
Turn-Off (ms)
1.8
Turn-On (ms)
LED Forward Voltage Drop (V)
LAA110
Typical LED Forward Voltage Drop
vs. Temperature
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
10µs 100µs 1ms 10ms 100ms
1s
10s 100s
Time
www.clare.com
149
Powered by ICminer.com Electronic-Library Service CopyRight 2003
DUAL POLE OptoMOS® RELAYS
LAA110/LAA110L
PERFORMANCE DATA
LAA110L
Typical On-Resistance Distribution
(N=50 Ambient Temperature = 25°C)
(Load Current = 120mADC; IF = 5mADC)
Device Count (N)
Device Count (N)
30
25
20
15
10
35
35
30
30
25
20
15
10
5
5
0
0
1.17
1.19
1.21
1.23
15
10
17.0
17.4
17.8
18.2
18.6
19.0
19.4
376.3 382.8 389.3 395.8 402.3 408.8 415.3
On-Resistance (Ω)
Blocking Voltage (V)
LAA110L
Typical IF for Switch Dropout
(N=50 Ambient Temperature = 25°C)
(Load Current = 120mADC)
LAA110L
Typical Turn-On Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 120mADC; IF = 5mADC)
25
20
20
20
15
10
15
10
5
5
0
0
0.75
1.05
1.35
1.65
1.95
Device Count (N)
25
Device Count (N)
25
0.45
0.75
1.05
1.35
1.65
1.95
2.25
0.15
5
100
20mA
10mA
5mA
80
60
40
0.225
LAA110L
Typical Blocking Voltage
vs. Temperature
0
20
380
40
60
80
120
0
20
40
60
80
100
0
20
40
60
80
100
LAA110L
Typical Turn-Off vs. Temperature
(Load Current = 120mADC)
1.600
0.700
1.400
0.600
1.200
0.500
1.000
0.800
0.600
5mA
10mA
20mA
0.400
0.300
0.200
0.100
5mA
0
-40
-20
0
Temperature (°C)
North America: 1-800-272-5273
-20
LAA110L
Typical Turn-On vs. Temperature
(Load Current = 120mADC)
0
-20
-40
Temperature (°C)
0.200
360
0.004
Temperature (°C)
0.400
370
100
Turn-Off (ms)
Turn-On (ms)
390
0.006
0
-20
Turn-Off (ms)
400
0.01
0.008
0.002
-40
410
0.65
0.012
120
0
420
0.55
140
20
0
0.45
0.014
Leakage (µA)
10
-40
0.35
LAA110L
Typical Leakage vs. Temperature
(Measured across Pins 5 & 6 or 7 & 8)
180
Load Current (mA)
15
0.175
0.25
Turn-On (ms)
160
20
0.125
5
LAA110L
Typical Load Current vs. Temperature
25
0.075
10
LED Current (mA)
LAA110L
Typical Turn-Off Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 120mADC; IF = 5mADC)
0.025
15
0
0.45
2.25
LED Current (mA)
Device Count (N)
20
0
1.25
LAA110L
Typical IF for Switch Operation
(N=50 Ambient Temperature = 25°C)
(Load Current = 120mADC)
Blocking Voltage (VRMS)
25
5
LED Forward Voltage Drop (V)
Device Count (N)
LAA110L
Typical Blocking Voltage Distribution
(N=50 Ambient Temperature = 25°C)
Device Count (N)
35
LAA110L
Typical LED Forward Voltage Drop
(N=50 Ambient Temperature = 25°C)
IF = 5mADC
20
40
60
80
100
Temperature (°C)
Europe: 32-11-300868
150
Powered by ICminer.com Electronic-Library Service CopyRight 2003
Asia: 886-2-2523-6368
-40
-20
0
20
40
60
Temperature (°C)
Japan: 03-3980-2212
80
100
DUAL POLE OptoMOS® RELAYS
LAA110/LAA110L
PERFORMANCE DATA
LAA110L
Typical Turn-On vs. LED Forward Current
(Load Current = 120mADC)
1.6
1.4
50mA
30mA
20mA
10mA
5mA
1.2
1.0
0.9
0.40
0.8
0.35
0.7
0.30
0.6
0.5
0.4
0.3
-20
0
20
40
60
80
100
0.25
0.20
0.15
0.2
0.10
0.1
0.05
0
0.8
-40
0
0
120
5
10
15
20
25
30
35
40
45
0
50
3.000
20.000
2.500
2.000
1.500
1.000
10.000
0.500
0
0
-20
0
20
40
60
80
Load Current (A)
Load Current (mA)
0
-50
-100
-150
-4
-3
-2
-1
0
1
2
3
4
Load Voltage (V)
30
35
40
45
50
2.500
2.000
1.500
1.000
0
20
40
60
80
100
-40
-20
0
20
40
60
80
100
Temperature (°C)
LAA110L
Energy Rating Curve
100
50
25
0
-20
Temperature (°C)
LAA110L
Typical Load Current vs. Load Voltage
(Ambient Temperature = 25°C)
IF = 5mADC
20
0.500
-40
100
Temperature (°C)
150
LED Current (mA)
3.500
3.000
Current (mA)
3.500
50.000
30.000
15
LAA110L
Typical IF for Switch Dropout
vs. Temperature
(Load Current = 120mADC)
60.000
40.000
10
LED Forward Current (mA)
LAA110L
Typical IF for Switch Operation
vs. Temperature
(Load Current = 120mADC)
LAA110L
Typical On-Resistance vs. Temperature
(Load Current = 120mADC; IF = 5mADC)
-40
5
LED Forward Current (mA)
Temperature (°C)
On-Resistance (Ω)
LAA110L
Typical Turn-Off vs. LED Forward Current
(Load Current = 120mADC)
Turn-Off (ms)
1.8
Turn-On (ms)
LED Forward Voltage Drop (V)
LAA110L
Typical LED Forward Voltage Drop
vs. Temperature
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
10µs 100µs 1ms 10ms 100ms
1s
10s 100s
Time
www.clare.com
151