ETC TS8-51

Switching, Sensing and Control Solutions
from GENTECH INTERNATIONAL LTD
Grangestone Industrial Estate, Girvan, Ayrshire KA26 9PS, United Kingdom
Telephone: +44 (0) 1465-713581. Fax: +44 (0) 1465 714974
Email: [email protected]
Website: gentech-international.co.uk
TS SERIES
THERMISTOR
SENSORS
DESIGN
FEATURES
● High or low level sensing
● Operation independent of
mounting attitude
● Will sense a variety of
mediums including Air
● Operating temperature
range up to 100ºC
● Glass filled polypropylene
or Nylon 6.6 material
● Easily installed even in
confined spaces
● Universal kit for internal
or external fitting
● Interface option
Applications
Thermistor Probe
Industries
Technical Specification
Low coolant level sensing
Automobile
Oil level sensing
Automobile, plant and equipment
Boiler level warning
Catering, vending machines
Working voltage
Operating temperature range
Chemical, plating, process engineering
Flood control
Domestic appliances
Reservoir high or low level sensing
Automobile, medical equipment
-20ºC to +100ºC
Typical Response Times
Glass filled
Polypropylene Nylon 6.6
-20ºC to
+100ºC
-20ºC to
+100ºC
Plastic Housing
Water absorption of eqillibrium
Air
Still to moving @ 20ºC
Moving to still @ 20ºC
<1 sec
<1 sec
Oil
Air to oil @ 20ºC
Oil to air @ 20ºC
Air to oil @ 70ºC
Oil to air @ 70ºC
<1 sec
10 sec
<1 sec
3 sec
Water
Air to water @ 94ºC
Water to air @ 94ºC
Air to water @ 5ºC
Water to air @ 5ºC
<1 sec
10 sec
<1 sec
30 sec
Fluid Viscosity
at 20ºC and 100% RH
<0.09%
5.6%
at 100ºC and 100% RH
<0.09%
5.6%
154ºC
245ºC
Heat distortion temperature
4.5kG/cm2 (67.6 (psig)
65.0 ohms
(depending on sensing medium)
Environmental Specifications
Thermistor probes may
attain a surface temperature
sufficient to cause burns
if touched
12.0v dc
9.0v dc
Resistance at 20ºC average
Solution monitoring
Operating temperature Range
maximum
minimum
Detailed chemical resistance information for specific liquids is available
on request.
When the application involves highly viscous fluids,
the fluid immediately around the thermistor probe
will heat up thus producing an incorrect result when
compared with the temperature of the bulk of the
fluid. This effect would be shown as a levelling of
the voltage/temperature characteristic at lower
temperatures. Fluids which produce sedimentary
deposits can increase the thermistor response time.
TS Internal Fitting
TS External Fitting
Lock Washer
45
(1.8)
Fixing Nut
45
(1.8)
Position
Orientation
Indicator
Thread M16x2
Pitch
Fixing Nut
Thread M16x2
Pitch
Position
Orientation
Indicator
The installation
hole should be
deburred and
clean
Hole ø16.5
(0.65)
Sealing Washer
24 AWG (7/0.2mm)
Tinned Conductor
PVC Clad
13
(0.51)
20
(0.79)
The installation
hole should be
deburred and
clean
Sealing
Grommet
(Nominal 0.5 metre length)
76.5
(3.01)
Friction Relief Washer
20
(0.79)
Hole ø23
(0.9)
13
(0.51)
76.5
(3.01)
Application Characteristics
Fig.2 shows a voltage versus temperature curve for
similar mediums to those in Fig.1 based on the test
circuit shown.
Fig. 1 shows a typical current versus voltage curve
relevant to the use of the TS level sensing probe. It can
be seen that it is possible to plot a family of curves to
cover a range of mediums at varying temperatures.
150
100
Volts (VDC)
Current (mA)
200
Test Circuit
9v
sensor
3.0
Water
Oil
(20-50 Multigrade)
10
Water
1.0
Oil (20-50
Multigrade)
50
Air
0
2
4
6
8
10
V out
2.0
Air
12
0
10
20
30
Volts (vdc)
40 50 60 70 80
Temperature (ºC)
90 100 110 120
Installation Notes
1. The position orientation indicator on housing
should be positioned at the top when fitted.
2. Care should be taken to ensure that the product is
not damaged due to excessive tightening of the
fixing nut or threaded bush.
Maximum torque limits are shown
Model
Torque Limit
Maximum Container
Wall Thickness
Internal Fitting
3lb ft. (4 Nm)
0.394ins. (10mm)
External Fitting
2lb ft. (2.67Nm)
0.16ins. (4mm)
(Compression Grommet)
Applications
Please contact Sales at Gentech for applications relating to this product group.
GENTECH INTERNATIONAL LTD
Grangestone Industrial Estate, Girvan, Ayrshire KA26 9PS, United Kingdom
Telephone: +44 (0) 1465-713581. Fax: +44 (0) 1465 714974
Email: [email protected]
Website: gentech-international.co.uk
Data Sheet Ref. TS-DS-2000-R1