ETC COMBI/E1

COMBI/E1
®
Power Management Module for ISDN NT1
SPECIFICATION Rev. 02
Type
COMBI/E1
Vi
Vo
195 to 253 Vac out1: 5 V
and
28 to 115 Vdc out 2: 40V
Io
PRODUCT VIEW
80 mA
120 mA
FEATURES
Uko INTERFACE (DC) and MAINS (AC) inputs
to enable NPM (Normal Power Mode) and
RPM (Restricted Power Mode) CONDITIONS
INPUT FILTER TO MEET EMI requirements
PEAK INPUT OVERVOLTAGE WITHSTANDING
ORDERING NUMBER: GS-COMBI/E1
AC INPUT PROTECTION FUSE
INPUTS TO OUTPUTS INSULATION
U-INTERFACE ACCORDING TO ETR080
2 INSULATED OUTPUTS:
Vo1=5 V for NT1 logics
Vo2=40 V for "S" interface
S-INTERFACE ACCORDING TO ETS 300
012
MTBF: 300 Kh, according to MIL HDBK 217-F
AUXILIARY LOGIC OUTPUT TTL-COMPATIBLE for LED & NPM/RPM MODE indication.
Operating Temperature: -10 to +70oC
INTERNAL RELAY FUNCTION FOR Vo2 POLARITY REVERSE
"S"
INTERFACE
OUTPUT
CHARACTERISTICS:
- Peak output of 220 mA for 150 ms
- Typical output power 4,5 W
- Output filtering to meet ETSI requirements
- Hold up time: 20 ms with 4,5 W output power
- Continuous short circuit protection
- Peak overvoltage withstand:1KV for 10/700 us
transversal
March 2001
1/6
COMBI/E1
DESCRIPTION
The NT1 Power Management Module COMBI/E1
is a comprehensive solution for ISDN-NT1 (Network Termination Basic Access NTBA) equipment, combining both AC-DC and DC-DC functions.
The GS-COMBI/E1 provide the NTBA with all
necessary supply voltages as well as control signals to operate in the different operating modes,
typically the Normal Power Mode (NPM) and Restricted Power Mode (RPM).
Connected to the main, Input 1 (2 poles AC connector) is the AC input power to the COMBI/E1,
source of the whole necessary power in normal
operating mode, namely in NPM. Input 2 is the
DC power source when in RPM, therefore to connect to the U-INTERFACE.
The device supply 5V (out 1) for logics and 40 V
(out 2) for the S interface both in Normal Power
Mode (NPM) and in Restricted Power Mode
(RPM).
RPM mode is the emergency condition that occurs if the mains (AC) input is not available. An
internal "relay function" is available to reverse the
40 V output polarity. A third auxiliary output can
be used for LEDs driving and RPM/NPM mode
acknowledge (Logic output).
The Logic output becomes high (+5V) when in
NPM condition.
2/6
The converter offers short-circuit protection on
both outputs: particularly, short-circuit on 40V output doesn’t affect the +5V output.
Out 1, out 2 and out 3 (Logic output) share the
same common return.
3000 VRMS insulation voltage for 60 seconds (reinforced insulation) is provided among input 1
and all outputs. Same reinforced insulation is also
provided between Input 1 and Input 2.
2000 VRMS / 1 min. reinforced insulation is provided between input 2 and all outputs.
When in NPM mode (AC main supply), the module max. power consumption is <15 VA (apparent
power).
Input 2 undervoltage lockout offers high impedance in order to have 10 uA max input current
when Vi2 is <18 Volts.
The design of the module has been conducted
using the following reference standards:
EN 60950, VDE0878 part 1 class B (EMC),
EN55022 class B (emission), EN50 082-1 (immunity) ITU-T I.430, ETS 300 012 and ETR 080 and
ETS300 047 (ISDN BASIC ACCESS, Safety and
Protection); anyway, please note that no certification processes have been carried out on the module itself.
COMBI/E1
ELECTRICAL CHARACTERISTICS when in NPM (Tamb=25oC, unless otherwise specified.)
NPM Standard Condition: Vin1 = 195 to 253 Vrms
Vin2 = 28 to 115 Vdc
Symbol
Parameter
Vi1
Input Voltage 1
Vi2
Input Voltage 2
fi
Test Condition
Min.
Typ.
Max.
Unit
195
253
VRMS
any polarity
28
115
Vdc
Vi1 Input Frequency
Vi1 = 230 VRMS
43
56
Hz
Vi1st
Start up Input 1 voltage
Output parameters
Standard Conditions
185
VRMS
Vi2st
Start up Input 2 voltage
Output parameters as per Standards
Conditions
44
Vdc
Vo1
Output Voltage 1
Standard conditions
4.75
5
5.25
V
Vo2
Output Voltage 2
Standard conditions
36
40
42
V
Vo3
Output Voltage 3
Standard conditions, Io3=0.9 to 3mA
4.5
5
5.25
V
Vor1
Output Ripple voltage 1
Standard conditions BW: 0-20 MHz
20
mVrms
Vor2
Output Ripple voltage 2
Standard conditions BW: 0-20 MHz
100
mVrms
Io1
Output Current 1
Standard conditions
3
80
mA
Io2
Output Current 2
Standard conditions
0
120
mA
Ioc2
Output Overcurrent 2
t=150ms, Vo1=34 to 42 V
220
240
260
mA
Io2sc
Output 2 short circuit current
Continuous short circuit
20
40
60
mA
Vi1th
NPM =>
threshold
160
Vrms
Ttr
Transition time
transition NPM => RPM and vice versa
5
ms
Vi1pk
Input 1 Transient overvoltage
t = 8/20 us transversal
2
kV
Vi2pk
Input 2 Transient overvoltage
t= 10/700 us transversal
500
V
1000
RPM
mode
as
per
NPM
Vi1 Output parameters as per Standard
Conditions
Vo2pk
Output 1 Transient overvoltage
t = 10/700 us transversal
Pi1r
Input 1 Real Power
NPM standard conditions
9
W
Pi1
Input 1 Apparent Power
NPM standard conditions
15
VA
Vist
Insulation Voltage, pulse
INputs to outputs t=10/700 us (pulse)
th
Hold-up time
Vin=195 VRMS Pout 1:0 to 340 mW
20
Pout 2: 4.5 W
4
V
kV
ms
3/6
COMBI/E1
ELECTRICAL CHARACTERISTICS when in RPM (Tamb=25oC, unless otherwise specified.)
RPM Standard Condition: Vin1 < 100 Vrms Vin2 = 28 to 115 Vdc
Symbol
Parameter
Test Condition
Min.
Typ.
Max.
Unit
Vi1
Input Voltage 1
Vi2
Input Voltage 2
Vi2st
Start Up Input 2 Voltage
Vo1
Output Voltage 1
RPM Standard Conditions
4.75
5
5.25
V
Vo2
Output Voltage 2
RPM Standard Conditions
34
40
42
V
Vo3
Output Voltage 3
RPM Standard conditions, out 3 load=50
kOhm
0.8
V
Vor1
Output Ripple Voltage 1
RPM Standard Conditions BW:0-20 Mhz
20
mVrms
Vor2
Output Ripple Voltage 2
RPM Standard Conditions BW:0-20 Mhz
100
mVrms
Io1
Output Current 1
RPM Standard Conditions
3
80
mA
Io2
Output Current 2
RPM Standard Conditions
0
12.5
mA
Continuous short circuit
9
13.5
mA
185
VRMS
5
ms
any polarity
0
100
Vrms
28
115
Vdc
44
Vdc
Io2sc
Output 2 short circuit current
Vi1th
RPM=>NPM
threshold
Ttr
Transition time
transition NPM => RPM and vice versa
Vi1pk
Input 1 Transient overvoltage
t = 8/20 us transversal
2.0
Kv
Vi2pk
Input 2 Transient overvoltage
t= 10/700 us transversal
500
V
Vo2pk
Out 2 Transient overvoltage
t= 10/700 us transversal
1000
V
Vist
Insulation Voltage, pulse
Inputs to outputs t=10/700 us (pulse)
4
kV
4/6
mode
Vi1
COMBI/E1
NT1 Power Management Module TOP VIEW (dimensions in mm
PIN CONFIGURATION
Input 1 (Vin 1: 230Vac) apply to the WAGO Series connector bottom right in the TOP VIEW
Pin No
Function
Pin No
Function
1
DC "U inteface" input (in 2)
4
Out common ground GND
2
DC"U inteface" input (in 2)
5
Out 2: +/-40 V output
3
Out 1: +5V output
6
Out 3: Logic output (NPM)
5/6
COMBI/E1
NT1 Power Management Module SIDE VIEW (dimensions in mm)
Information furnished is believed to be accurate and reliable. However, STMicroelectronics assumes no responsibility for the consequences
of use of such information nor for any infringement of patents or other rights of third parties which may result from its use. No license is
granted by implication or otherwise under any patent or patent rights of STMicroelectronics. Specification mentioned in this publication are
subject to change without notice. This publication supersedes and replaces all information previously supplied. STMicroelectronics products
are not authorized for use as critical components in life support devices or systems without express written approval of STMicroelectronics.
The ST logo is a registered trademark of STMicroelectronics
© 2001 STMicroelectronics – Printed in Italy – All Rights Reserved
STMicroelectronics GROUP OF COMPANIES
Australia - Brazil - China - Finland - France - Germany - Hong Kong - India - Italy - Japan - Malaysia - Malta - Morocco Singapore - Spain - Sweden - Switzerland - United Kingdom - U.S.A.
http://www.st.com
6/6