ETC GS-COMBI/F3

COMBI/F3
POWER MANAGEMENT MODULE FOR ISDN NT1
REV. 01
Type
Vi
Vo
Io
195 to 253
Vac and 28 to
115 Vdc
out 1:3.3V
100 mA
COMBI/F3
out 2:40V
120 mA
FEATURE
■ Uko INTERFACE (DC) and MAINS (AC) inputs
to enable NPM (Normal Power Mode) and RPM
(Restricted Power Mode) CONDITIONS
■ INPUT FILTER TO MEET EMI requirements
■ PEAK INPUT OVERVOLTAGE
WITHSTANDING
■ AC INPUT PROTECTION FUSE
■ INPUTS TO OUTPUTS INSULATION
■ 2 INSULATED OUTPUTS:
ORDERING NUMBER: GS-COMBI/F3-3.3
Vo1=3.3 V for NT1 logics
DESCRIPTION
Vo2=40 V for “S” interface
AUXILIARY LOGIC OUTPUT TTLCOMPATTIBLE for LED & NPM/RPM MODE
indication, share the same ground of Vo1
The NT1 Power Management Module COMBI/F3 is a
comprehensive solution for ISDN-NT1 (Network Termination Basic Access NTBA) equipment, combining
both AC-DC and DC-DC functions.
■
AUXILIARY LOGIC OUTPUT TTLCOMPATTIBLE for LED & NPM/RPM MODE
indication, share the same ground of Vo2
■
INTERNAL RELAY FUNCTION FOR Vo2
POLARITY REVERSE
“S” INTERFACE OUTPUT
CHARACTERISTICS:
The GS-COMBI/F3 provide the NTBA with all necessary supply voltages as well as control signals to operate in the different operating modes, typically the
Normal Power Mode (NPM) and Restricted Power
Mode (RPM).
■
■
- Peak output of 220 mA for 150 ms
- Typical output power 4,5 W
- Output filtering to meet ETSI requirements
- Hold up time: 20 ms with 4,5 W output power
- Continuous short circuit protection
■
- Peak overvoltage withstand: 1KV for 10/700 us
transversal
U-INTERFACE ACCORDING TO ETR080
S-INTERFACE ACCORDING TO ETS 300 012
MTBF: 300 Kh, according to MIL HDBK 217-F
■
Operating Temperature: -10 to +70oC
■
■
Connected to the main, Input 1 (2 poles AC connector) is the AC input power to the COMBI/F3, source
of the whole necessary power in normal operating
mode, namely in NPM. Input 2 is the DC power
source when in RPM, therefore to connect to the UINTERFACE.
The device supply 3.3V (out 1) for logics and 40V (out
2) for the S interface both in Normal Power Mode
(NPM) and in Restricted Power Mode (RPM).
RPM mode is the emergency condition that occurs if
the mains (AC) input is not available. An internal “relay function” is available to reverse the 40 V output
polarity. A third auxiliary output can be used for LEDs
driving and RPM/NPM mode acknowledge (Logic
output), referred to 3.3 V output and a fourth auxiliary
output can be used for LEDs driving and RPM/NPM
October 2003
This is preliminary information on a new product now in development. Details are subject to change without notice.
1/7
COMBI/F3
mode acknowledge (Logic output), referred to 40 V.
The logics outputs become high (+3.3V) when in NPM condition.
The converter offers short-circuit protection on both outputs: particularly, short-circuit on 40V output doesn’t affect the +3.3V output.
6000 VRMS insulation voltage for 60 seconds (reinforced insulation) is provided among input 1 and all outputs.
Same reinforced insulation is also provided between Input 1 and Input 2.
3000 VRMS / 1 min. reinforced insulation is provided between Input 2 and 40 V output.
When in NPM mode (AC main supply), the module max. power consumption is <15 VA (apparent power).
Input 2 undervoltage lockout offers high impedance in order to have 10µA max input current when Vi2 is <18
Volts.
Th design of the module has been conducted using the following reference standards:
EN 60950, VDE0878 part 1 class B (EMC), EN55022 class B (emission), EN50 082-1 (immunity) ITU-T I.430,
ETS 300 012 and ETR 080 and ETS300 047 (ISDN BASIC ACCESS, Safety and Protection); anyway, please
note that no certification processes have been carried out on the module itself.
2/7
COMBI/F3
ELECTRICAL CHARACTERISTICS when in NPM (Tamb=25)C, unless otherwise specified.)
NPM Standard Condotion:Vin1=195 to 253 Vrms -------------Vin2=28 to 115 Vd
Symbol
Parameter
Test Condition
Min.
Typ.
Max.
Unit
195
253
VRMS
Vi1
Input Voltage 1
Vi2
Input Voltage 2
any polarity
28
115
Vdc
Vi1 Input Frequency
Vi1 = 230 VRMS
43
56
Hz
Vi1st
Start up Input 1 voltage
Output parameters as per NPM
Standard Conditions
185
VRMS
Vi2st
Start up Input 2 voltage
Output parameters as per Standard
Conditions
28
Vdc
Vo1
Output Voltage 1
Standard conditions
3.1
3.3
3.5
V
Vo2
Output Voltage 2
Standard conditions
36
40
42
V
Vo3
Output Voltage 3 LED “U”
Standard conditions, Io3=0.9 to 3 mA
3.0
3.3
3.5
V
Vo4
Output Voltage 4
Standard conditions, Io4=1 to 2 mA
2.0
3.0
3.5
V
Vor1
Output Ripple voltage 1
Standard conditions BW: 0-20 MHz
20
mVrms
Vo2
Output Ripple voltage 2
Standard conditions BW: 0-20 MHz
100
mVrms
Io1
Output Current 1
Standard conditions
3
100
mA
Io2
Output Current 2
Standard conditions
0
120
mA
Ioc2
Output Overcurrrent 2
t=150ms, Vo1=34 to 42 V
180
220
260
mA
Io2sc
Output 2 short circuit current
Continuous short circuit
100
150
200
mA
Vi1th
NPM => RPM mode Vi1
threshold
Output parameters as per Standard
Conditions
160
Vrms
Transition time
transition NPM => RPM and vice
versa
5
ms
Vi1pk
Input 1 Transient overvoltage
t = 8/20 us transversal
Vi2pk
Input 2 Transient overvoltage
Vo2pk
fi
Ttr
2
kV
t = 10/700 us transversal
500
V
Output 1 Transient overvoltage
t = 10/700 us transversal
1000
V
Pi1r
Input 1 Real Power
NPM standard conditions
9
W
Pi1
Input 1 Apparent Power
NPM standard conditions
15
VA
Vist
Insulation Voltage, pulse
Inputs to Vo2 output t = 10/700 us
(pulse)
10
kV
Hold-up time
Vin = 195 VRMS Pout 1:0 to 340 mW
Pout 2:4.5 W
20
ms
th
3/7
COMBI/F3
ELECTRICAL CHARACTERISTICS when in RPM (Tamb=25)C, unless otherwise specified.)
RPM Standard Condition: Vin1 < 100 Vrms -------------Vin2 = 28 to 115 Vdc
Symbol
Parameter
V1
Input Voltage 1
Vi2
Input Voltage 2
Test Condition
any polarity
Min.
Typ.
Max.
Unit
0
100
Vrms
28
115
Vdc
28
Vdc
Vi2st
Start Up Input 2 Voltage
Vo1
Output Voltage 1
RPM Standard Conditions
3.1
3.3
3.5
V
Vo2
Output Voltage 2
RPM Standard Conditions
36
40
42
V
Output Voltage 3, 4
RPM Standard conditions, out 3, 4 load =
50 kOhm
0.5
V
Vor1
Output Ripple Voltage 1
RPM Standard Conditions BW:0-20 Mhz
20
mVrms
Vor2
Output Ripple Voltage 2
RPM Standard Conditions BW:0-20 Mhz
100
mVrms
Io1
Output Current 1
RPM Standard Conditions
3
100
mA
Io2
Output Current 2
RPM Standard Conditions
0
12.5
mA
Io2sc
Output 2 short circuit current
Continuous short circuit
9
13.5
mA
Vi1th
RPM => NPM mode Vi1
threshold
185
VRMS
5
ms
Vo3, 4
Trt
Transition time
transition NPM => RPM and vice versa
Vi1pk
Input 1 Transient overvoltage
t = 8/20 us transversal
2.0
Kv
Vi2pk
Input 2 Transient overvoltage
t = 10/700 us transversal
500
V
Vo2pk
Out 2 Transient overvoltage
t = 10/700 us transversal
1000
V
Insulation Voltage, pulse
Inputs to Vo2 output t = 10/700 us (pulse)
10
kV
Vist
4/7
COMBI/F3
Figure 1. NT1 Power Management Module TOP VIEW (dimensions in mm)
PIN CONFIGURATION
Input 1 (Vin 1: 230 Vac) apply to the WAGO Series connector bottom right in the TOP VIEW
Pin No
Function
Pin No
Function
1
Vi2 Input Voltage 2 VDC
5
Vo3 Output Voltage 3 LED “U”
2
Vi2 Input Voltage 2 VDC
6
GNDB GROUND PIN for Vo2 and Vo4
3
GNDA GROUND PIN for Vo1 and Vo3
7
Vo2 Output Voltage 2-- ! 40 V --“S”
4
Vo1 Output Voltage 1 ---3.3 VDC
8
Vo4 Output Voltage 4 LED- “S”
5/7
COMBI/F3
Figure 2. NT1 Power Management Module SIDE VIEW (dimensions in mm)
6/7
COMBI/F3
Information furnished is believed to be accurate and reliable. However, STMicroelectronics assumes no responsibility for the consequences
of use of such information nor for any infringement of patents or other rights of third parties which may result from its use. No license is granted
by implication or otherwise under any patent or patent rights of STMicroelectronics. Specifications mentioned in this publication are subject
to change without notice. This publication supersedes and replaces all information previously supplied. STMicroelectronics products are not
authorized for use as critical components in life support devices or systems without express written approval of STMicroelectronics.
The ST logo is a registered trademark of STMicroelectronics.
All other names are the property of their respective owners
© 2003 STMicroelectronics - All Rights Reserved
STMicroelectronics GROUP OF COMPANIES
Australia - Belgium - Brazil - Canada - China - Czech Republic - Finland - France - Germany - Hong Kong - India - Israel - Italy - Japan Malaysia - Malta - Morocco - Singapore - Spain - Sweden - Switzerland - United Kingdom - U.S.A.
http://www.st.com
7/7