ETC HCPL-2300

8 MBd Low Input Current
Optocoupler
Technical Data
HCPL-2300/HCPL-0300
Features
• Guaranteed Low Thresholds:
IF = 0.5 mA, VF ≤ 1.5 V
• High Speed: Guaranteed
5 MBd over Temperature
• Versatile: Compatible with
TTL, LSTTL and CMOS
• Efficient 820 nm AlGaAs
LED
• Internal Shield for
Guaranteed Common Mode
Rejection
• Schottky Clamped, Open
Collector Output with
Optional Integrated Pull-Up
Resistor
• Static and Dynamic
Performance Guaranteed
from -40°C to 85°C
• Safety Approval
UL Recognized -2500 V rms for
1 minute
CSA Approved
VDE 0884 Approved with
VIORM = 630 V peak
(Option 060)
• Microprocessor System
Interfaces
• Digital Isolation for A/D,
D/A Conversion
• RS-232-C Interface
• High Speed, Long Distance
Isolated Line Receiver
combination of Agilent designed
and manufactured semiconductor
devices brings new high
performance capabilities to
designers of isolated logic and
data communication circuits.
The HCPL-2300/HCPL-0300
optocoupler combines an 820 nm
AlGaAs photon emitting diode
with an integrated high gain
photon detector. This
The new low current, high speed
AlGaAs emitter manufactured
with a unique diffused junction,
has the virtue of fast rise and fall
times at low drive currents.
Figure 6 illustrates the propagation delay vs. input current
characteristic. These unique
Functional Diagram
Schematic
Description
ICC
NC
1
8
1000 Ω
VCC
8
7
ANODE
2
7
IF
RL
+
2
6
VCC
RL
VO
VF
CATHODE
3
6
VOUT
–
NC
4
Applications
• Ground Loop Elimination
• Computer-Peripheral
Interfaces
• Level Shifting
5
GND
3
SHIELD
A 0.1 µF CAPACITOR MUST
BE CONNECTED BETWEEN
PINS 8 AND 5 (SEE NOTE 1).
5
GND
TRUTH TABLE
(POSITIVE LOGIC)
LED
OUTPUT
ON
L
OFF
H
A 0.1 pF bypass capacitor must be connected between pins 5 and 8.
CAUTION: It is advised that normal static precautions be taken in handling and assembly of this component to
prevent damage and/or degradation which may be induced by ESD.
2
characteristics enable this device
to be used in an RS-232-C interface with ground loop isolation
and improved common mode
rejection. As a line receiver, the
HCPL-2300/HCPL-0300 will
operate over longer line lengths
for a given data rate because of
lower IF and VF specifications.
collector Schottky clamped transistor. The shield, which shunts
capacitively coupled common
mode noise to ground, provides a
guaranteed transient immunity
specification of 100 V/µs. The
output circuit includes an
optional integrated 1000 Ω pullup resistor for the open collector.
This gives designers the flexibility
to use the internal resistor for
pull-up to five volt logic or to use
The output of the shielded integrated detector circuit is an open
an external resistor for connection to supply voltages up to 18 V
(CMOS logic voltage).
The Electrical and Switching
Characteristics of the
HCPL-2300/HCPL-0300 are
guaranteed over a temperature
range of -40°C to 85°C. This
enables the user to confidently
design a circuit which will
operate under a broad range of
operating conditions.
Ordering Information
Specify part number followed by Option Number (if desired).
HCPL-2300# XXX
060 = VDE 0884 VIORM = 630 V peak Option
300 = Gull Wing Surface Mount Lead Option
500 = Tape/Reel Package Option (1 K min)
Option data sheets available. Contact your Agilent sales representative or authorized distributor for
information.
Package Outline Drawings
Small Outline SO-8
Package HCPL-0300
8
7
6
5
5.994 ± 0.203
(0.236 ± 0.008)
XXX
YWW
3.937 ± 0.127
(0.155 ± 0.005)
TYPE NUMBER
(LAST 3 DIGITS)
DATE CODE
PIN ONE 1
2
3
0.406 ± 0.076
(0.016 ± 0.003)
4
1.270 BSG
(0.050)
* 5.080 ± 0.127
(0.200 ± 0.005)
3.175 ± 0.127
(0.125 ± 0.005)
7°
45° X
0.432
(0.017)
0 ~ 7°
0.228 ± 0.025
(0.009 ± 0.001)
1.524
(0.060)
0.203 ± 0.102
(0.008 ± 0.004)
* TOTAL PACKAGE LENGTH (INCLUSIVE OF MOLD FLASH)
5.207 ± 0.254 (0.205 ± 0.010)
DIMENSIONS IN MILLIMETERS (INCHES).
LEAD COPLANARITY = 0.10 mm (0.004 INCHES) MAX.
0.305 MIN.
(0.012)
3
8-Pin DIP Package (HCPL-2300)
7.62 ± 0.25
(0.300 ± 0.010)
9.65 ± 0.25
(0.380 ± 0.010)
8
TYPE NUMBER
7
6
5
6.35 ± 0.25
(0.250 ± 0.010)
OPTION CODE*
DATE CODE
A XXXXZ
YYWW RU
1
2
3
4
UL
RECOGNITION
1.78 (0.070) MAX.
1.19 (0.047) MAX.
5° TYP.
4.70 (0.185) MAX.
+ 0.076
0.254 - 0.051
+ 0.003)
(0.010 - 0.002)
0.51 (0.020) MIN.
2.92 (0.115) MIN.
0.65 (0.025) MAX.
1.080 ± 0.320
(0.043 ± 0.013)
DIMENSIONS IN MILLIMETERS AND (INCHES).
2.54 ± 0.25
(0.100 ± 0.010)
* MARKING CODE LETTER FOR OPTION NUMBERS.
"V" = OPTION 060
OPTION NUMBERS 300 AND 500 NOT MARKED.
8-Pin DIP Package with Gull Wing Surface Mount Option 300 (HCPL-2300)
PAD LOCATION (FOR REFERENCE ONLY)
9.65 ± 0.25
(0.380 ± 0.010)
8
7
6
1.016 (0.040)
1.194 (0.047)
5
4.826 TYP.
(0.190)
6.350 ± 0.25
(0.250 ± 0.010)
1
2
3
9.398 (0.370)
9.906 (0.390)
4
1.194 (0.047)
1.778 (0.070)
1.19
(0.047)
MAX.
1.780
(0.070)
MAX.
9.65 ± 0.25
(0.380 ± 0.010)
7.62 ± 0.25
(0.300 ± 0.010)
4.19 MAX.
(0.165)
1.080 ± 0.320
(0.043 ± 0.013)
0.635 ± 0.130
2.54
(0.025 ± 0.005)
(0.100)
BSC
DIMENSIONS IN MILLIMETERS (INCHES).
LEAD COPLANARITY = 0.10 mm (0.004 INCHES).
0.381 (0.015)
0.635 (0.025)
0.635 ± 0.25
(0.025 ± 0.010)
+ 0.076
0.254 - 0.051
+ 0.003)
(0.010 - 0.002)
12° NOM.
4
TEMPERATURE – °C
Thermal Profile (Option #300)
260
240
220
200
180
160
∆T = 145°C, 1°C/SEC
∆T = 115°C, 0.3°C/SEC
140
120
100
80
∆T = 100°C, 1.5°C/SEC
60
40
20
0
0
1
2
3
4
5
6
7
8
9
10
11
12
TIME – MINUTES
Figure 1. Maximum Solder Reflow Thermal Profile.
(Note: Use of non-chlorine activated fluxes is recommended.)
Regulatory Information
The HCPL-2300 has been
approved by the following
organizations:
UL
Recognized under UL 1577,
Component Recognition
Program, File E55361.
CSA
Approved under CSA Component
Acceptance Notice #5, File CA
88324.
VDE
Approved according to VDE
0884/06.92 (Option 060 only)
Insulation and Safety Related Specifications
Parameter
Min. External Air Gap
(External Clearance)
Min. External Tracking Path
(External Creepage)
Symbol
L(IO1)
7.1
mm
L(IO2)
7.4
mm
0.08
mm
200
Volts
Min. Internal Plastic Gap
(Internal Clearance)
Tracking Resistance
(Comparative Tracking Index)
Isolation Group
Value Units
CTI
IIIa
Conditions
Measured from input terminals to output
terminals, shortest distance through air
Measured from input terminals to output
terminals, shortest distance path along body
Through insulation distance, conductor to
conductor, usually the direct distance
between the photoemitter and photodetector
inside the optocoupler cavity
DIN IEC 112/VDE 0303 PART 1
Material Group (DIN VDE 0110, 1/89, Table 1)
Option 300 – surface mount classification is Class A in accordance with CECC 00802.
5
VDE 0884 Insulation Related Characteristics (HCPL-2300 Option 060 ONLY)
Description
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 300 V rms
for rated mains voltage ≤ 450 V rms
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
VIORM x 1.875 = VPR, 100% Production Test with t m = 1 sec,
Partial Discharge < 5 pC
Input to Output Test Voltage, Method a*
VIORM x 1.5 = VPR, Type and sample test, tm = 60 sec,
Partial Discharge < 5 pC
Highest Allowable Overvoltage*
(Transient Overvoltage, tini = 10 sec)
Safety Limiting Values
(Maximum values allowed in the event of a failure,
also see Figure 11, Thermal Derating curve.)
Case Temperature
Input Current
Output Power
Insulation Resistance at TS, VIO = 500 V
Symbol
Characteristic
Units
VIORM
I-IV
I-III
55/85/21
2
630
V peak
VPR
1181
V peak
VPR
945
V peak
VIOTM
6000
V peak
TS
IS,INPUT
PS,OUTPUT
RS
175
230
600
≥ 109
°C
mA
mW
Ω
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, (VDE 0884), for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in
application.
Absolute Maximum Ratings
(No Derating Required up to 55°C)
Storage Temperature, TS ............................................. -55°C to +125°C
Operating Temperature, TA ........................................... -40°C to +85°C
Lead Solder Temperature, max .......................................... 260°C for 10 s
(1.6 mm below seating plane)
Average Forward Input Current - IF ............................................ 5 mA[2]
Reverse Input Voltage, VR .............................................................. 3.0 V
Supply Voltage, VCC ............................................................... 0 V to 7.0 V
Pull-Up Resistor Voltage, VRL ............................................. -0.5 V to VCC
Output Collector Current, IO ............................................ -25 to 25 mA
Input Power Dissipation, PI ........................................................ 10 mW
Output Collector Power Dissipation, PO ..................................... 40 mW
Output Collector Voltage, VO ........................................... -0.5 V to 18 V
Infrared and Vapor Phase Reflow Temperature
(Option #300) .......................................... see Fig. 1, Thermal Profile
Recommended Operating Conditions
Parameter
Input Voltage, Low Level
Input Current High Level
Supply Voltage, Output
Fan Out (TTL Load)
Operating Temperature
0°C to 85°C
-40°C to 85°C
Symbol
VFL
IFH
VCC
N
TA
Min.
-2.5
0.5
0.5
4.75
-40
Max.
0.8
1.0
0.75
5.25
5
85
Units
V
mA
V
°C
6
DC Electrical Specifications
For -40°C ≤ TA ≤ 85°C, 4.75 V ≤ VCC ≤ 5.25 V, VFL ≤ 0.8 V, unless otherwise specified.
All typicals at TA = 25°C and VCC = 5 V , unless otherwise specified. See note 1.
Parameter
Symbol
High Level Output
IOH
Current
Low Level Output
VOL
Voltage
High Level Supply
ICCH
Current
Low Level Supply Current
ICCL
Input Forward Voltage
VF
Input Diode Temperature
Coefficient
Input Reverse
Breakdown Voltage
Input Capacitance
Internal Pull-up Resistor
Min. Typ. Max. Units
Test Conditions
0.05 250
µA
VF = 0.8 V, VO = 18 V
1.0
0.85
0.4
0.5
V
4.0
6.3
mA
IF = 0.5 mA
IOL (Sinking) = 8 mA
IF = 0 mA, VCC = 5.25 V
6.2
1.3
10.0
1.5
1.65
mA
V
IF = 1.0 mA, VCC = 5.25 V
TA = 25°C
IF = 1.0 mA
∆VF
∆TA
BVR
3.0
CIN
RL
18
680 1000 1700
-1.6
Fig. Note
4
3
2
mV/°C IF = 1.0 mA
V
pF
Ω
IR = 10 µA
VF = 0 V, f = 1 MHz
TA = 25°C
Switching Specifications
For -40°C ≤ TA ≤ 85°C, 0.5 mA ≤ IFH ≤ 0.75 mA;
For 0°C ≤ TA ≤ 85°C, 0.5 mA ≤ IFH ≤ 1.0 mA; With 4.75 V ≤ VCC ≤ 5.25 V, VFL ≤ 0.8 V, unless otherwise
specified. All typicals at TA = 25°C and VCC = 5 V, IFH = 0.625 mA, unless otherwise specified. See note 1.
Parameter
Propagation Delay Time
to Logic High Output Level
Symbol
tPLH
Min.
Propagation Delay Time
to Logic Low Output Level
tPHL
Output Rise Time (10-90%)
Output Fall Time (90-10%)
Common Mode Transient
Immunity at High
Output Level
tr
tf
|CMH|
100
Typ.
95
85
110
35
40
20
400
Common Mode Transient
Immunity at Low
Output Level
|CML|
100
400
Max. Units
ns
160
ns
200
ns
ns
V/µs
V/µs
Test Conditions Fig. Note
CP = 0 pF
5, 6, 8 4, 8
CP = 20 pF
5, 8
CP = 0 pF
5, 6, 8 5, 8
CP = 20 pF
5, 8
CP = 20 pF
7, 8
8
VCM = 50 V (peak), 9, 10
VO (min.) = 2 V,
RL = 560 Ω,
IF = 0 mA
VCM = 50 V (peak), 9, 10
VO (max.) = 0.8 V,
RL = 560 Ω,
IF = 0.5 mA
6
7
7
Package Characteristics
For -40°C ≤ TA ≤ 85°C, unless otherwise specified. All typicals at TA = 25°C.
Parameter
Symbol
Input-Output Momentary
VISO
Withstand Voltage*
Resistance, Input-Output
RI-O
Capacitance, Input-Output
CI-O
Min.
2500
Typ.
1012
0.6
Max. Units
V rms
Ω
pF
Test Conditions
RH ≤ 50%, t = 1 min,
TA = 25°C
VI-O = 500 V
f = 1 MHz
Fig. Notes
3, 9
3
3
*The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output
continuous voltage rating. For the continuous voltage rating refer to the VDE 0884 Insulation Characteristics Table (if applicable),
your equipment level safety specification, or Agilent Application Note 1074, “Optocoupler Input-Output Endurance Voltage.”
Notes:
1. Bypassing the power supply line is
required with a 0.1 µF ceramic disc
capacitor adjacent to each optocoupler
as illustrated in Figure 19. The power
supply bus for the optocoupler(s)
should be separate from the bus for
any active loads, otherwise a larger
value of bypass capacitor (up to
0.5 µF) may be needed to suppress
regenerative feedback via the power
supply.
2. Peaking circuits may produce transient
input currents up to 100 mA, 500 ns
maximum pulse width, provided
average current does not exceed 5 mA.
Figure 2. Typical Input Diode
Forward Characteristics.
3. Device considered a two terminal
device: pins 1, 2, 3, and 4 shorted
together, and pins 5, 6, 7, and 8
shorted together.
4. The t PLH propagation delay is
measured from the 50% point on the
trailing edge of the input pulse to the
1.5 V point on the trailing edge of the
output pulse.
5. The t PHL propagation delay is
measured from the 50% point on the
leading edge of the input pulse to the
1.5 V point on the leading edge of the
output pulse.
6. CM H is the maximum tolerable rate of
rise of the common mode voltage to
assure that the output will remain in a
high logic state (i.e., VOUT > 2.0 V).
7. CML is the maximum tolerable rate of
fall of the common mode voltage to
assure that the output will remain in a
low logic state (i.e., VOUT < 0.8 V).
8. CP is the peaking capacitance. Refer to
test circuit in Figure 8.
9. In accordance with UL 1577, each
optocoupler is momentary withstand
proof tested by applying an insulation
test voltage ≥ 3000 Vrms for 1 second
(leakage detection current limit,
II-O ≤ 5 µA). This test is performed
before the 100% production test for
partial discharge (Method b) shown in
the VDE 0884 Insulation Characteristics Table, if applicable.
Figure 3. Typical Output Voltage vs.
Forward Input Current vs.
Temperature.
Figure 4. Typical Logic High Output
Current vs. Temperature.
8
Figure 6. Typical Propagation Delay
vs. Forward Current.
Figure 7. Typical Rise, Fall Time vs.
Temperature.
Figure 5. Typical Propagation Delay
vs. Temperature and Forward
Current with and without Application
of a Peaking Capacitor.
HCPL-2300
HCPL-0300
Figure 8. Test Circuit for tPHL , tPLH , tr, and tf.
Figure 9. Typical Common Mode
Transient Immunity vs. Common
Mode Transient Amplitude.
9
HCPL-0300/
HCPL-2300
OUTPUT POWER – PS, INPUT CURRENT – IS
Figure 10. Test Circuit for Common Mode Transient Immunity and Typical Waveforms.
800
PS (mW)
700
IS (mA)
600
500
400
300
200
100
0
0
25
50
75 100 125 150 175 200
TS – CASE TEMPERATURE – °C
Figure 11. Thermal Derating Curve,
Dependence of Safety Limiting Value
with Case Temperature per
VDE 0884.
Applications
The HCPL-2300/HCPL-0300
optocoupler has the unique
combination of low 0.5 mA LED
operating drive current at a
5 MBd speed performance. Low
power supply current
requirement of 10 mA maximum
at 5.25 V and the ability to
provide isolation between logic
systems fulfills numerous
applications ranging from logic
level translations, line receiver
and party line receiver
applications, microprocessor I/O
port isolation, etc. The open collector output allows for wired-OR
arrangement. Specific interface
circuits are illustrated in Figures
12-16, and 18 with corresponding component values, performance data and recommended
layout in Figures 17 and 19.
For -40°C to 85°C operating
temperature range, a mid-range
LED forward current (I F) of
0.625 mA is recommended in
order to prevent overdriving the
integrated circuit detector due to
increased LED efficiency at
temperatures between 0°C and
-40°C. For narrower temperature
range of 0°C to 85°C, a suggested
operating LED current of
0.75 mA is recommended for the
mid-range operating point and for
minimal propagation delay skew.
A peaking capacitance of 20 pF
in parallel with the current
limiting resistor for the LED
shortens t PHL by approximately
33% and tPLH by 13%. Maintaining LED forward voltage (VF)
below 0.8 V will guarantee that
the HCPL-2300/HCPL-0300
output is off.
The recommended shunt drive
technique for TTL/LSTTL/CMOS
of Figure 12 provides for optimal
speed performance, no leakage
current path through the LED,
and reduced common mode
influences associated with series
switching of a “floating” LED.
Alternate series drive techniques
with either an active CMOS
inverter or an open collector TTL/
LSTTL inverter are illustrated in
Figures 13 and 14 respectively.
Open collector leakage current of
250 µA has been compensated by
the 3.16 KΩ resistor (Figure 14)
at the expense of twice the
operating forward current.
An application of the HCPL-2300/
HCPL-0300 as an unbalanced line
receiver for use in long line
twisted wire pair communication
links is shown in Figure 15. Low
LED IF and VF allow longer line
length, higher speed and multiple
stations on the line in comparison
to higher IF, VF optocouplers.
Greater speed performance along
with nearly infinite common
mode immunity are achieved via
the balanced split phase circuit
of Figure 16. Basic balanced
differential line receiver can
be accomplished with one
HCPL-2300/HCPL-0300 in
Figure 16, but with a typical
400 V/µs common mode
immunity. Data rate versus
distance for both the above
unbalanced and balanced line
receiver applications are compared in Figure 17. The RS-232-C
interface circuit of Figure 18
10
provides guaranteed minimum
common mode immunity of
100 V/µs while maintaining the
2:1 dynamic range of IF.
A recommended layout for use
with an internal 1000 Ω resistor
or an external pull-up resistor
and required VCC bypass capacitor is given in Figure 19. VCC1 is
used with an external pull-up
resistor for output voltage levels
(VO ) greater than or equal to 5 V.
As illustrated in Figure 19, an
optional VCC and GND trace can
be located between the input
and the output leads of the
HCPL-2300/HCPL-0300 to
provide additional noise
immunity at the compromise of
insulation capability (VI-O).
HCPL-2300/
HCPL-0300
Figure 12. Recommended Shunt Drive Circuit for Interfacing between TTL/LSTTL/CMOS Logic Systems.
HCPL-2300/
HCPL-0300
HCPL-2300/
HCPL-0300
Figure 13. Active CMOS Series Drive Circuit.
Figure 14. Series Drive from Open Collector TTL/LSTTL
Units.
11
HCPL-2300/
HCPL-0300
REFERENCE FIGURE 17 FOR DATA RATE vs. LINE DISTANCE L.
Figure 15. Application of HCPL-2300/HCPL-0300 as Isolated, Unbalanced Line Receiver(s).
HCPL-2300/
HCPL-0300
REFERENCE FIGURE 17 FOR DATA RATE vs. LINE DISTANCE L.
HCPL-2300/
HCPL-0300
Figure 16. Application of Two HCPL-2300/HCPL-0300 Units Operating as an Isolated, High Speed, Balanced, Split Phase
Line Receiver with Significantly Enhanced Common Mode Immunity.
(FIGURE 16)
(FIGURE 15)
Figure 17. Typical Point to Point Data Rate vs. Length of
Line for Unbalanced (Figure 15) and Balanced (Figure 16)
Line Receivers Using HCPL-2300/HCPL-0300 Optocouplers.
HCPL-2300/
HCPL-0300
RS-232-C
SIGNAL
3 V – 25 V
-3 V – -25 V
Figure 18. RS-232-C Interface Circuit with HCPL-2300/
HCPL-0300. 0°C < TA < 85°C.
Figure 19. Recommended Printed Circuit Board Layout.
www.semiconductor.agilent.com
Data subject to change.
Copyright © 2001 Agilent Technologies, Inc.
July 31, 2001
Obsoletes 5965-3587E
5980-3133EN