AD ADUM5200CRWZ

Dual Channel Isolators with
Integrated DC-to-DC Converter
ADuM5200/ADuM5201/ADuM5202
FEATURES
FUNCTIONAL BLOCK DIAGRAM
VDD1 1
OSC
RECT
REG
16
VISO
15
GNDISO
14
VIA/VOA
VIB/VOB 4
13
VIB/VOB
RCIN 5
12
NC
11
VSEL
GND1 2
VIA/VOA 3
RCSEL 6
ADuM5200/
ADuM5201/
ADuM5202
VE1/NC 7
GND1 8
10
VE2/NC
9
GNDISO
07540-001
2-CHANNEL iCOUPLER CORE
Figure 1.
VIB
APPLICATIONS
3
14
ADuM5200
4
13
VOA
VOB
07540-002
VIA
Figure 2. ADuM5200
RS-232/RS-422/RS-485 transceivers
Industrial field bus isolation
Power supply startups and gate drives
Isolated sensor interfaces
Industrial PLCs
VIA
VOB
3
14
ADuM5201
4
13
VOA
VIB
07540-003
isoPower integrated isolated dc-to-dc converter
Regulated 3 V or 5 V output
Up to 500 mW output power
Dual dc-to-25 Mbps (NRZ) signal isolation channels
Schmitt trigger inputs
16-lead SOIC package with >8 mm creepage
High temperature operation: 105°C maximum
High common-mode transient immunity: >25 kV/μs
Safety and regulatory approvals
UL recognition
2500 V rms for 1 minute per UL 1577
CSA Component Acceptance Notice #5A (pending)
VDE certificate of conformity (pending)
DIN V VDE V 0884-10 (VDE V 0884-10):2006-12
VIORM = 560 V peak
Figure 3. ADuM5201
VOB
3
14
ADuM5202
4
13
VIA
VIB
07540-004
VOA
Figure 4. ADuM5202
GENERAL DESCRIPTION
The ADuM520x1 are dual channel digital isolators with
isoPower, an integrated, isolated dc-to-dc converter. Based on
the Analog Devices, Inc., iCoupler® technology, the dc-to-dc
converter provides up to 500 mW of regulated, isolated power
with 5.0 V input and 5.0 V output voltage, or 200 mW of power
with 3.3 V input and 3.3 V output voltage. This eliminates the
need for a separate isolated dc-to-dc converter in low power
isolated designs. The Analog Devices chip scale transformer
iCoupler technology is used for the isolation of the logic signals
as well as for the dc-to-dc converter. The result is a small form
factor, total isolation solution.
levels and greater channel counts (see the Increasing Available
Power section).
The ADuM520x isolators provide two independent isolation
channels in a variety of channel configurations and data rates
(see the Ordering Guide for options).
isoPower uses high frequency switching elements to transfer
power through its transformer. Special care must be taken
during printed circuit board (PCB) layout to meet emissions
standards. Refer to the AN-0971 application note for details on
board layout recommendations.
ADuM520x units can be used in combination with the
ADuM5401, ADuM5402, ADuM5403, ADuM5404, and
ADuM5000 with isoPower® to achieve higher output power
1
Protected by U.S. Patents: 5,952,849; 6,873,065; 6,903,578; and 7,075,329. Other patents are pending.
Rev. 0
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice. No
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
www.analog.com
Fax: 781.461.3113
©2008 Analog Devices, Inc. All rights reserved.
ADuM5200/ADuM5201/ADuM5202
TABLE OF CONTENTS
Features .............................................................................................. 1
Pin Configurations and Function Descriptions ......................... 11
Applications ....................................................................................... 1
Typical Performance Characteristics ........................................... 15
Functional Block Diagram .............................................................. 1
Terminology .................................................................................... 17
General Description ......................................................................... 1
Applications Information .............................................................. 18
Revision History ............................................................................... 2
PCB Layout ................................................................................. 18
Specifications..................................................................................... 3
EMI Considerations ................................................................... 18
Electrical Characteristics—5 V Primary Input Supply/5 V
Secondary Isolated Supply .......................................................... 3
Propagation Delay Parameters ................................................. 19
Electrical Characteristics—3.3 V Primary Input Supply/3.3 V
Secondary Isolated Supply .......................................................... 5
Power Consumption .................................................................. 20
Package Characteristics ............................................................... 7
Regulatory Information ............................................................... 7
Insulation and Safety-Related Specifications ............................ 7
DIN V VDE V 0884-10 (VDE V 0884-10) Insulation
Characteristics .............................................................................. 8
DC Correctness and Magnetic Field Immunity........................... 19
Current Limit and Thermal Overload Protection ................. 20
Power Considerations ................................................................ 21
Thermal Analysis ....................................................................... 21
Increasing Available Power ....................................................... 21
Insulation Lifetime ..................................................................... 22
Recommended Operating Conditions ...................................... 9
Outline Dimensions ....................................................................... 23
Absolute Maximum Ratings.......................................................... 10
Ordering Guide .......................................................................... 23
ESD Caution ................................................................................ 10
REVISION HISTORY
10/08—Revision 0: Initial Version
Rev. 0 | Page 2 of 24
ADuM5200/ADuM5201/ADuM5202
SPECIFICATIONS
ELECTRICAL CHARACTERISTICS—5 V PRIMARY INPUT SUPPLY/5 V SECONDARY ISOLATED SUPPLY
4.5 V ≤ VDD1 ≤ 5.5 V, VSEL = VISO; each voltage is relative to its respective ground. All minimum/maximum specifications apply over the
entire recommended operating range, unless otherwise noted. All typical specifications are at TA = 25°C, VDD = 5.0 V, VISO = 5.0 V, VSEL = VISO.
Table 1.
Parameter
DC-TO-DC CONVERTER POWER SUPPLY
Setpoint
Line Regulation
Load Regulation
Output Ripple
Output Noise
Switching Frequency
Pulse-Width Modulation Frequency
DC-to-2 Mbps Data Rate1
Maximum Output Supply Current 2
Efficiency @ Maximum Output Supply
Current 3
IDD1 Supply Current, No VISO Load
Symbol
Min
Typ
Max
Unit
Test Conditions
VISO
VISO(LINE)
VISO(LOAD)
VISO(RIP)
4.7
5.0
1
1
75
5.4
V
mV/V
%
mV p-p
IISO = 0 mA
IISO = 50 mA, VDD1 = 4.5 V to 5.5 V
IISO = 10 mA to 90 mA
20 MHz bandwidth, CBO = 0.1 μF||10 μF,
IISO = 90 mA
CBO = 0.1 μF||10 μF, IISO = 90 mA
VISO(N)
fOSC
fPWM
IISO(MAX)
5
200
180
625
mV p-p
MHz
kHz
100
mA
34
%
IDD1(Q)
8
IDD1(D)
34
mA
ADuM5201
IDD1(D)
38
mA
ADuM5202
IDD1(D)
41
mA
IISO(LOAD)
94
mA
ADuM5201
IISO(LOAD)
92
mA
ADuM5202
IISO(LOAD)
90
mA
IDD1(MAX)
290
mA
VUV+
VUV−
VUVH
2.7
2.4
0.3
V
V
V
25 Mbps Data Rate (CRWZ Grade Only)
IDD1 Supply Current, No VISO Load
ADuM5200
Available VISO Supply Current 4
ADuM5200
IDD1 Supply Current, Full VISO Load5
Undervoltage Lockout, VDD1 and VISO
Supply 6
Positive Going Threshold
Negative Going Threshold
Hysteresis
iCoupler DATA CHANNELS
I/O Input Currents
Logic High Input Threshold
Logic Low Input Threshold
IIA, IIB
VIH
−20
0.7 × VISO,
0.7 × VIDD1
+0.01
VIL
Rev. 0 | Page 3 of 24
22
mA
+20
μA
V
0.3 × VISO,
0.3 × VIDD1
V
VISO > 4.5 V, dc to 1 MHz logic signal
frequency
IISO = 100 mA, dc to 1 MHz logic signal
frequency
IISO = 0 mA, dc to 1 MHz logic signal
frequency
IISO = 0 mA, CL = 15 pF, 12.5 MHz logic
signal frequency
IISO = 0 mA, CL = 15 pF, 12.5 MHz logic
signal frequency
IISO = 0 mA, CL = 15 pF, 12.5 MHz logic
signal frequency
CL = 15 pF, 12.5 MHz logic signal
frequency
CL = 15 pF, 12.5 MHz logic signal
frequency
CL = 15 pF, 12.5 MHz logic signal
frequency
CL = 0 pF, dc to 1 MHz logic signal
frequency, VDD = 4.5 V, IISO = 100 mA
ADuM5200/ADuM5201/ADuM5202
Parameter
Logic High Output Voltages
Symbol
VOAH, VOBH
VOAH, VOBH
Logic Low Output Voltages
AC SPECIFICATIONS
ADuM520xARWZ 7
Minimum Pulse Width
Maximum Data Rate
Propagation Delay
Pulse Width Distortion, |tPLH − tPHL|
Propagation Delay Skew
Channel-to-Channel Matching
ADuM520xCRWZ
Minimum Pulse Width7
Maximum Data Rate
Propagation Delay
Pulse Width Distortion, |tPLH − tPHL|
Change vs. Temperature
Propagation Delay Skew
Channel-to-Channel Matching,
Codirectional Channels
Channel-to-Channel Matching,
Opposing-Directional Channels
For All Models
Output Rise/Fall Time (10% to 90%)
Common-Mode Transient Immunity
at Logic High Output
Common-Mode Transient Immunity
at Logic Low Output
Refresh Rate
Min
VDD1 − 0.3,
VISO − 0.3
VDD1 − 0.5,
VISO − 0.5
VOAL, VOBL
Typ
5.0
Max
Unit
V
Test Conditions
IOx = −20 μA, VIx = VIxH
V
IOx = −4 mA, VIx = VIxH
0.1
0.4
V
V
IOx = 20 μA, VIx = VIxL
IOx = 4 mA, VIx = VIxL
1000
ns
Mbps
ns
ns
ns
ns
CL = 15 pF, CMOS signal levels
CL = 15 pF, CMOS signal levels
CL = 15 pF, CMOS signal levels
CL = 15 pF, CMOS signal levels
CL = 15 pF, CMOS signal levels
CL = 15 pF, CMOS signal levels
CL = 15 pF, CMOS signal levels
CL = 15 pF, CMOS signal levels
CL = 15 pF, CMOS signal levels
CL = 15 pF, CMOS signal levels
CL = 15 pF, CMOS signal levels
CL = 15 pF, CMOS signal levels
CL = 15 pF, CMOS signal levels
4.8
0.0
0.0
PW
1
tPHL, tPLH
PWD
tPSK
tPSKCD, tPSKOD
55
PW
100
40
50
50
40
tPSK
tPSKCD
15
6
ns
Mbps
ns
ns
ps/°C
ns
ns
tPSKOD
15
ns
CL = 15 pF, CMOS signal levels
CL = 15 pF, CMOS signal levels
VIx = VDD or VISO, VCM = 1000 V, transient
magnitude = 800 V
VIx = 0 V, V = 1000 V, transient
magnitude = 800 V
25
tPHL, tPLH
PWD
45
60
6
5
tR/tF
|CMH|
25
2.5
35
ns
kV/μs
|CML|
25
35
kV/μs
1.0
Mbps
fr
1
The contributions of supply current values for all four channels are combined at identical data rates.
VISO supply current is available for external use when all data rates are below 2 Mbps. At data rates above 2 Mbps, data I/O channels draw additional current
proportional to the data rate. Additional supply current associated with an individual channel operating at a given data rate may be calculated as described in the
Power Consumption section. The dynamic I/O channel load must be treated as an external load and be included in the VISO power budget.
3
The power demands of the quiescent operation of the data channels cannot be separated from the power supply section. Efficiency includes the quiescent power
consumed by the I/O channels as part of its internal power consumption.
4
This current is available for driving external loads at the VISO pin. All channels are simultaneously driven at a maximum data rate of 25 Mbps with the full capacitive load
representing the maximum dynamic load conditions. Refer to the Power Consumption section for the calculation of available current at less than the maximum data rate.
5
IDD1(MAX) is the input current under full dynamic and VISO load conditions.
6
Undervoltage lockout (UVLO) holds the outputs in a low state if the corresponding input or output power supply is below the referenced threshold. Hysteresis is built
into the detection threshold to prevent oscillations and noise sensitivity.
7
The minimum pulse width is the shortest pulse width at which the specified pulse width distortion is guaranteed.
2
Rev. 0 | Page 4 of 24
ADuM5200/ADuM5201/ADuM5202
ELECTRICAL CHARACTERISTICS—3.3 V PRIMARY INPUT SUPPLY/3.3 V SECONDARY ISOLATED SUPPLY
3.0 V ≤ VDD1 ≤ 3.6 V, VSEL = GNDISO; each voltage is relative to its respective ground. All minimum/maximum specifications apply over
the entire recommended operating range, unless otherwise noted. All typical specifications are at TA = 25°C, VDD = 3.3 V, VISO = 3.3 V, VSEL=
GNDISO.
Table 2.
Parameter
DC-TO-DC CONVERTER POWER SUPPLY
Setpoint
Line Regulation
Load Regulation
Output Ripple
Output Noise
Switching Frequency
Pulse-Width Modulation Frequency
DC to 2 Mbps Data Rate1
Maximum Output Supply Current 2
Symbol
Min
Typ
Max
Unit
Test Conditions
VISO
VISO(LINE)
VISO(LOAD)
VISO(RIP)
3.13
3.3
1
1
50
3.37
V
mV/V
%
mV p-p
IISO = 0 mA
IISO = 30 mA, VDD1 = 3.0 V to 3.6 V
IISO = 6 mA to 54 mA
20 MHz bandwidth, CBO = 0.1 μF||10μF,
IISO = 54 mA
CBO = 0.1μF||10μF, IISO = 54 mA
VISO(N)
fOSC
fPWM
IISO(MAX)
5
130
180
625
mV p-p
MHz
kHz
60
mA
36
%
VISO > 3.0 V, dc to 1 MHz logic signal
frequency
IISO = 60 mA, dc to 1 MHz logic signal
frequency
IISO = 0 mA, dc to 1 MHz logic signal
frequency
Efficiency @ Maximum Output Supply
Current 3
IDD1 Supply Current, No VISO load
IDD1(Q)
6
IDD1 Supply Current, Full VISO load
IDD1(MAX)
175
mA
CL = 0 pF, f = 0 MHz, VDD = 3.3 V, IISO =
60 mA
IDD1(D)
23
mA
ADuM5201
IDD1(D)
25
mA
ADuM5202
IDD1(D)
27
mA
IISO = 0 mA, CL = 15 pF, 12.5 MHz logic
signal frequency
IISO = 0 mA, CL = 15 pF, 12.5 MHz logic
signal frequency
IISO = 0 mA, CL = 15 pF, 12.5 MHz logic
signal frequency
IISO(LOAD)
56
mA
ADuM5201
IISO(LOAD)
55
mA
ADuM5202
IISO(LOAD)
54
mA
VUV+
VUV−
VUVH
2.7
2.4
0.3
V
V
V
25 Mbps Data Rate (CRWZ Grade Only)
IDD1 Supply Current, No VISO Load4
ADuM5200
Available VISO Supply Current 5
ADuM5200
Undervoltage Lockout (UVLO), VDD1 and
VISO Supply 6
Positive Going Threshold
Negative Going Threshold
Hysteresis
iCoupler DATA CHANNELS
I/O Input Currents
Logic High Input Threshold
IIA, IIB
VIH
Logic Low Input Threshold
VIL
Logic High Output Voltages
VOAH,
VOBH
VOAH,
VOBH
VOAL, VOBL
VOAL, VOBL
Logic Low Output Voltages
−20
+0.01
15
+20
μA
V
0.3 × VISO,
0.3 × VIDD1
V
0.7 × VISO,
0.7 × VIDD1
VDD1 − 0.2,
VISO − 0.2
VDD1 − 0.5,
V1SO − 0.5
mA
CL = 15 pF, 12.5 MHz logic signal
frequency
CL = 15 pF, 12.5 MHz logic signal
frequency
CL = 15 pF, 12.5 MHz logic signal
frequency
3.3
V
IOx = −20 μA, VIx = VIxH
3.1
V
IOx = −4 mA, VIx = VIxH
V
V
IOx = 20 μA, VIx = VIxL
IOx = 4 mA, VIx = VIxL
0.0
0.0
Rev. 0 | Page 5 of 24
0.1
0.4
ADuM5200/ADuM5201/ADuM5202
Parameter
AC SPECIFICATIONS
ADuM520xARWZ
Minimum Pulse Width 7
Maximum Data Rate
Propagation Delay
Pulse Width Distortion, |tPLH − tPHL|
Propagation Delay Skew
Channel-to-Channel Matching
ADuM520xCRWZ
Minimum Pulse Width7
Maximum Data Rate
Propagation Delay
Pulse Width Distortion, |tPLH − tPHL|
Change vs. Temperature
Propagation Delay Skew
Channel-to-Channel Matching,
Codirectional Channels
Channel-to-Channel Matching,
Opposing-Directional Channels
For All Models
Output Rise/Fall Time (10% to 90%)
Common-Mode Transient Immunity
at Logic High Output
Common-Mode Transient Immunity
at Logic Low Output
Refresh Rate
Symbol
Min
Typ
PW
Max
Unit
Test Conditions
1000
ns
Mbps
ns
ns
ns
ns
CL = 15 pF, CMOS signal levels
CL = 15 pF, CMOS signal levels
CL = 15 pF, CMOS signal levels
CL = 15 pF, CMOS signal levels
CL = 15 pF, CMOS signal levels
CL = 15 pF, CMOS signal levels
CL = 15 pF, CMOS signal levels
CL = 15 pF, CMOS signal levels
CL = 15 pF, CMOS signal levels
CL = 15 pF, CMOS signal levels
CL = 15 pF, CMOS signal levels
CL = 15 pF, CMOS signal levels
CL = 15 pF, CMOS signal levels
1
tPHL, tPLH
PWD
tPSK
tPSKCD, tPSKOD
60
PW
100
40
50
50
40
tPSK
tPSKCD
45
6
ns
Mbps
ns
ns
ps/°C
ns
ns
tPSKOD
15
ns
CL = 15 pF, CMOS signal levels
CL = 15 pF, CMOS signal levels
VIx = VDD or VISO, VCM = 1000 V,
transient magnitude = 800 V
VIx = 0 V, V = 1000 V,
transient magnitude = 800 V
25
tPHL, tPLH
PWD
45
60
6
5
tR/tF
|CMH|
25
2.5
35
ns
kV/μs
|CML|
25
35
kV/μs
1.0
Mbps
fr
1
The contributions of supply current values for all four channels are combined at identical data rates.
VISO supply current is available for external use when all data rates are below 2 Mbps. At data rates above 2 Mbps data I/O channels draw additional current
proportional to the data rate. Additional supply current associated with an individual channel operating at a given data rate may be calculated as described in the
Power Consumption section. The dynamic I/O channel load must be treated as an external load and be included in the VISO power budget.
3
The power demands of the quiescent operation of the data channels cannot be separated from the power supply section. Efficiency includes the quiescent power
consumed by the I/O channels as part of its internal power consumption.
4
IDD1(D) is the typical input supply current with all channels simultaneously driven at a maximum data rate of 25 Mbps with the full capacitive load representing the
maximum dynamic load conditions. Treat resistive loads on the outputs separately from the dynamic load.
5
This current is available for driving external loads at the VISO pin. All channels are simultaneously driven at a maximum data rate of 25 Mbps with the full capacitive load
representing the maximum dynamic load conditions. Refer to the Power Consumption section for the calculation of available current at less than the maximum data rate.
6
Undervoltage lockout (UVLO) holds the outputs in a low state if the corresponding input or output power supply is below the referenced threshold. Hysteresis is built
into the detection threshold to prevent oscillations and noise sensitivity.
7
The minimum pulse width is the shortest pulse width at which the specified pulse width distortion is guaranteed.
2
Rev. 0 | Page 6 of 24
ADuM5200/ADuM5201/ADuM5202
PACKAGE CHARACTERISTICS
Table 3.
Parameter
RESISTANCE AND CAPACITANCE
Resistance (Input-to-Output) 1
Capacitance (Input-to-Output)1
Input Capacitance 2
IC Junction to Ambient Thermal Resistance
THERMAL SHUTDOWN
Threshold
Hysteresis
Symbol
Min
Typ
Max
Unit
RI-O
CI-O
CI
θJA
1012
2.2
4.0
45
Ω
pF
pF
°C/W
TSSD
TSSD-HYS
150
20
°C
°C
Test Conditions
f = 1 MHz
Thermocouple located at the center of the package
underside; test conducted on a 4-layer board with
thin traces 3
TJ rising
1
This device is considered a 2-terminal device; Pin 1 through Pin 8 are shorted together, and Pin 9 through Pin 16 are shorted together.
Input capacitance is from any input data pin to ground.
3
Refer to the Power Considerations section for thermal model definitions.
2
REGULATORY INFORMATION
The ADuM5200/ADuM5201/ADuM5202 are approved by the organizations listed in Table 4. Refer to Table 9 and the Insulation Lifetime
section for details regarding recommended maximum working voltages for specific cross isolation waveforms and insulation levels.
Table 4.
UL
Recognized under 1577 Component
Recognition Program 1
Single Protection 2500 V RMS Isolation
Voltage
File E214100
1
2
CSA (Pending)
Approved under CSA Component
Acceptance Notice #5A
Reinforced insulation per CSA 60950-1-03
and IEC 60950-1, 400 V rms (566 V peak)
maximum working voltage
File 205078
VDE (Pending)
Certified according to DIN V VDE V 0884-10
(VDE V 0884-10):2006-12 2
Reinforced insulation, 560 V peak
File 2471900-4880-0001
In accordance with UL 1577, each ADuM520x is proof tested by applying an insulation test voltage ≥ 3000 V rms for 1 sec (current leakage detection limit = 5 μA).
In accordance with DIN V VDE V 0884-10, each ADuM520x is proof tested by applying an insulation test voltage ≥ 1050 V peak for 1 sec (partial discharge detection
limit = 5 pC). The * marking branded on the component designates DIN V VDE V 0884-10 approval.
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 5.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Symbol Value
2500
L(I01)
>8 min
Unit Conditions
V rms 1-minute duration
mm
Measured from input terminals to output terminals,
shortest distance through air
>8 min
mm
Measured from input terminals to output terminals,
shortest distance path along body
0.017 min mm
Distance through the insulation
>175
V
DIN IEC 112/VDE 0303 Part 1
IIIa
Material group (DIN VDE 0110, 1/89, Table 1)
Minimum External Tracking (Creepage)
L(I02)
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
CTI
Rev. 0 | Page 7 of 24
ADuM5200/ADuM5201/ADuM5202
DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS
These isolators are suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by
protective circuits. The * marking on packages denotes DIN V VDE V 0884-10 approval.
Table 6.
Description
Installation Classification per DIN VDE 0110
For Rated Mains Voltage ≤ 150 V rms
For Rated Mains Voltage ≤ 300 V rms
For Rated Mains Voltage ≤ 400 V rms
Climatic Classification
Pollution Degree per DIN VDE 0110, Table 1
Maximum Working Insulation Voltage
Input-to-Output Test Voltage
Method b1
Conditions
VIORM × 1.875 = VPR, 100% production test, tm = 1 sec,
partial discharge < 5 pC
VIORM × 1.6 = VPR, tm = 60 sec, partial discharge < 5 pC
Method a
After Environmental Tests Subgroup 1
After Input and/or Safety Test
Subgroup 2 and Subgroup 3
Highest Allowable Overvoltage
Safety-Limiting Values
Symbol
Characteristic
Unit
VIORM
I to IV
I to III
I to II
40/105/21
2
560
V peak
VPR
1050
V peak
896
672
V peak
V peak
VTR
4000
V peak
TS
IS1
RS
150
555
>109
°C
mA
Ω
VPR
VIORM × 1.2 = VPR, tm = 60 sec, partial discharge < 5 pC
Transient overvoltage, tTR = 10 sec
Maximum value allowed in the event of a failure
(see Figure 5)
Case Temperature
Side 1 IDD1 Current
Insulation Resistance at TS
VIO = 500 V
Thermal Derating Curve
500
400
300
200
100
0
0
50
100
150
AMBIENT TEMPERATURE (°C)
200
07540-005
SAFE OPERATING VDD1 CURRENT (mA)
600
Figure 5. Thermal Derating Curve, Dependence of Safety Limiting Values on Case Temperature, per DIN EN 60747-5-2
Rev. 0 | Page 8 of 24
ADuM5200/ADuM5201/ADuM5202
RECOMMENDED OPERATING CONDITIONS
Table 7.
Parameter
OPERATING TEMPERATURE
SUPPLY VOLTAGES 1
VDD1 @ VSEL = 0 V
VDD1 @ VSEL = VDD1 V
Minimum Load
Minimum Power-On Slew Rate
1
Symbol
TA
Min
−40
Max
+105
Unit
°C
VDD
VDD
IISO(MIN)
VSLEW
3.0
4.5
10
150
3.6
5.5
V
V
mA
V/ms
Each voltage is relative to its respective ground.
Rev. 0 | Page 9 of 24
ADuM5200/ADuM5201/ADuM5202
ABSOLUTE MAXIMUM RATINGS
Ambient temperature = 25°C, unless otherwise noted.
Table 9. Maximum Continuous Working Voltage Supporting
a 50-Year Minimum Lifetime1
Table 8.
Parameter
Storage Temperature (TST)
Ambient Operating Temperature (TA)
Supply Voltages (VDD, VISO)1
VISO Supply Current2
Input Voltage
(VIA, VIB, VE1, VE2,RCSEL, VSEL)1, 3
Output Voltage
(VOA, VOB)1, 3
Average Output Current per Data
Output Pin4
Common-Mode Transients5
Rating
−55°C to +150°C
−40°C to +105°C
−0.5 V to +7.0 V
100 mA
−0.5 V to VDDI + 0.5 V
Parameter
Max
Unit
Reference Standard
AC Voltage
Bipolar Waveform
424
V peak
50-year minimum
lifetime
Unipolar Waveform
Basic Insulation
600
V peak
560
V peak
Maximum approved
working voltage per
IEC 60950-1
Maximum approved
working voltage per
IEC 60950-1 and
VDE V 0884-10
600
V peak
560
V peak
−0.5 V to VDDO + 0.5 V
Reinforced Insulation
−10 mA to +10 mA
−100 kV/μs to +100 kV/μs
1
Each voltage is relative to its respective ground.
The VISO provides current for dc and dynamic loads on the Side 2
input/output channels. This current must be included when determining the
total VISO supply current.
3
VDDI and VDDO refer to the supply voltages on the input and output sides of a
given channel, respectively. See the PCB Layout section.
4
See Figure 5 for maximum rated current values for various temperatures.
5
Refers to common-mode transients across the insulation barrier. Commonmode transients exceeding the absolute maximum ratings may cause latch-up
or permanent damage.
DC Voltage
Basic Insulation
2
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Reinforced Insulation
1
Maximum approved
working voltage per
IEC 60950-1
Maximum approved
working voltage per
IEC 60950-1 and
VDE V 0884-10
Refers to continuous voltage magnitude imposed across the isolation
barrier. See the Insulation Lifetime section for more details.
ESD CAUTION
Rev. 0 | Page 10 of 24
ADuM5200/ADuM5201/ADuM5202
PIN CONFIGURATIONS AND FUNCTION DESCRIPTIONS
VDD1 1
16
VISO
GND1 2
15
GNDISO
VIA 3
14
VOA
RCIN 5
ADuM5200
13 VOB
TOP VIEW
(Not to Scale) 12 NC
RCSEL 6
11
VSEL
NC 7
10
VE2
GND1 8
9
GNDISO
07540-006
VIB 4
NC = NO CONNECT
Figure 6. ADuM5200 Pin Configuration
Table 10. ADUM5200 Pin Function Descriptions
Pin No. Mnemonic
1
VDD1
2, 8
GND1
3
4
5
VIA
VIB
RCIN
6
RCSEL
7, 12
9, 15
NC
GNDISO
10
VE2
11
VSEL
13
14
16
VOB
VOA
VISO
Description
Primary Supply Voltage 3.0 V to 5.5 V.
Ground 1. Ground reference for the isolator primary side. Pin 2 and Pin 8 are internally connected to each other, and it is
recommended that both pins be connected to a common ground.
Logic Input A.
Logic Input B.
Regulation Control Input. This pin must be connected to an RCOUT signal from another device or tied low. Note: This
pin must not be tied high if RCSEL is low; this combination causes excessive voltage on the secondary side, damaging
the ADuM5200 and possibly the devices that it powers.
Control Input. Determines self-regulation (RCSEL high) mode or slave mode (RCSEL low) allowing external regulation.
This pin is weakly pulled to the high state. In noisy environments, tie it either high or low.
No Internal Connection.
Ground Reference for Isolator Side 2. Pin 9 and Pin 15 are internally connected to each other, and it is recommended that
both pins be connected to a common ground.
Data Enable Input. When high or no connect, the secondary outputs are active; when low, the outputs are in a
high-Z state.
Output Voltage Selection. When VSEL = VISO, the VISO setpoint is 5.0 V. When VSEL = GNDISO, the VISO setpoint is 3.3 V. In
slave regulation mode, this pin has no function.
Logic Output B.
Logic Output A.
Secondary Supply Voltage. Output for secondary side isolated data channels and external loads.
Rev. 0 | Page 11 of 24
ADuM5200/ADuM5201/ADuM5202
VDD1 1
16
VISO
GND1 2
15
GNDISO
VIA 3
14
VOA
RCIN 5
ADuM5201
13 VIB
TOP VIEW
(Not to Scale) 12 NC
RCSEL 6
11
VSEL
VE1 7
10
VE2
GND1 8
9
GNDISO
07540-007
VOB 4
NC = NO CONNECT
Figure 7. ADuM5201 Pin Configuration
Table 11. ADuM5201 Pin Function Descriptions
Pin No. Mnemonic Description
1
VDD1
Primary Supply Voltage 3.0 V to 5.5 V.
2, 8
GND1
Ground 1. Ground reference for isolator primary side. Pin 2 and Pin 8 are internally connected to each other, and it is
recommended that both pins be connected to a common ground.
3
VIA
Logic Input A.
4
VOB
Logic Output B.
5
RCIN
Regulation Control Input. This pin must be connected to an RCOUT signal from another device or tied low. Note: This pin
must not be tied high if RCSEL is low; this combination causes excessive voltage on the secondary side, damaging the
ADuM5201 and possibly the devices that it powers.
6
RCSEL
Control Input. Determines self-regulation mode (RCSEL high) or slave mode (RCSEL low) allowing external regulation.
This pin is weakly pulled to the high state. In noisy environments, tie it either high or low.
7
VE1
Data Enable Input. When high or no connect, the primary output is active; when low, the outputs are in a high-Z state.
9, 15
GNDISO
Ground Reference for Isolator Side 2. Pin 9 and Pin 15 are internally connected to each other, and it is recommended that
both pins be connected to a common ground.
10
VE2
Data Enable Input. When high or no connect, the secondary output is active; when low, the outputs are in a
high-Z state.
11
VSEL
Output Voltage Selection. When VSEL = VISO, the VISO setpoint is 5.0 V. When VSEL = GNDISO, the VISO setpoint is 3.3 V. In
slave regulation mode, this pin has no function.
12
NC
No Internal Connection.
13
VIB
Logic Input B.
14
VOA
Logic Output A.
16
VISO
Secondary Supply Voltage. Output for secondary side isolated data channels and external loads.
Rev. 0 | Page 12 of 24
ADuM5200/ADuM5201/ADuM5202
VDD1 1
16
VISO
GND1 2
15
GNDISO
VOA 3
14
VIA
RCIN 5
ADuM5202
13 VIB
TOP VIEW
(Not to Scale) 12 NC
RCSEL 6
11
VSEL
VE1 7
10
NC
GND1 8
9
GNDISO
07540-008
VOB 4
NC = NO CONNECT
Figure 8. ADuM5202 Pin Configuration
Table 12. ADuM5202 Pin Function Descriptions
Pin No. Mnemonic Description
1
VDD1
Primary Supply Voltage 3.0 V to 5.5 V.
2, 8
GND1
Ground 1. Ground reference for the isolator primary. Pin 2 and Pin 8 are internally connected to each other, and it is
recommended that both pins be connected to a common ground.
3
VOA
Logic Output A.
4
VOB
Logic Output B.
5
RCIN
Regulation Control Input. This pin must be connected to an RCOUT signal from another device or tied low. Note: This pin
must not be tied high if RCSEL is low; this combination causes excessive voltage on the secondary side, damaging the
ADuM5202 and possibly the devices that it powers.
6
RCSEL
Control Input. Determines self-regulation (RCSEL high) mode or slave mode (RCSEL low) allowing external regulation.
This pin is weakly pulled to the high state. In noisy environments, tie it either high or low.
7
VE1
Data Enable Input. When high or no connect, the primary output is active; when low, the outputs are in a high-Z state.
9, 15
GNDISO
Ground Reference for Isolator Side 2. Pin 9 and Pin 15 are internally connected to each other, and it is recommended that
both pins be connected to a common ground.
10, 12 NC
No Internal Connection.
11
VSEL
Output Voltage Selection. When VSEL = VISO, the VISO setpoint is 5.0 V. When VSEL = GNDISO, the VISO setpoint is 3.3 V.
13
VIB
Logic Input B.
14
VIA
Logic Input A.
16
VISO
Secondary Supply Voltage. Output for secondary side isolated data channels and external loads.
Rev. 0 | Page 13 of 24
ADuM5200/ADuM5201/ADuM5202
Table 13. Truth Table (Positive Logic)
RCIN
Input
X
X
X
X
EXT-PWM 1
L
X
X
H
1
RCSEL
Input
H
H
H
H
L
L
X
X
L
VSEL
Input1
H
L
H
L
X
L
X
X
X
VDDI
Input
5.0 V
5.0 V
3.3 V
3.3 V
X
X
X
X
X
VISO
Output
5.0 V
3.3 V
5.0 V
3.3 V
X
0V
X
X
X
VIX
Input
X
X
X
X
X
X
H
L
X
VOX
Output
X
X
X
X
X
X
H
L
X
Operation
Master mode operation, self-regulating.
Power configuration not supported.
Power configuration not supported.
Master mode operation, self-regulating.
Slave mode operation, regulation from another isoPower part.
Low power mode, converter disabled.
Data outputs valid for any active power configuration.
Data outputs valid for any active power configuration.
Note: This combination of RCIN and RCSEL is prohibited. Damage
occurs on the secondary side of the converter due to excess
output voltage at VISO. RCIN must be either low or a PWM signal
from a master isoPower part.
PWM refers to the regulation control signal. This signal is derived from the secondary side regulator or from the RCIN input, depending on the value of RCSEL.
Rev. 0 | Page 14 of 24
ADuM5200/ADuM5201/ADuM5202
TYPICAL PERFORMANCE CHARACTERISTICS
40
35
EFFICIENCY (%)
30
25
20
15
5V IN/5V OUT
3.3V IN/3.3V OUT
10
0
0
0.02
0.04
0.06
0.08
0.10
OUTPUT CURRENT (A)
Figure 9. Typical Power Supply Efficiency at 5 V/5 V and 3.3 V/3.3 V
POWER
DISSIPATION
2.5
2.0
1.5
1.0
IDD
0.5
07540-009
5
3.0
0
3.0
3.5
4.0
4.5
VDD1 (V)
5.0
5.5
6.0
Figure 12. Typical Short-Circuit Input Current and Power vs. VDD1
Supply Voltage
OUTPUT VOLTAGE
(500mV/DIV)
1.0
0.9
0.7
0.6
0.4
0.3
5V IN/5V OUT
3.3V IN/3.3V OUT
0.2
0
0
0.02
0.04
0.06
IISO (A)
0.08
0.10
0.12
10% LOAD
07540-124
0.1
07540-012
90% LOAD
0.5
DYNAMIC LOAD
POWER DISSIPATION (W)
0.8
(100µs/DIV)
Figure 13. Typical VISO Transient Load Response 5 V Output
10% to 90% Load Step
Figure 10. Typical Total Power Dissipation vs. IISO with Data Channels Idle
OUTPUT VOLTAGE
(500mV/DIV)
0.12
0.08
0.04
0.02
5V IN/5V OUT
3.3V IN/3.3V OUT
0
0
0.05
0.10
0.15
0.20
INPUT CURRENT (A)
0.25
0.30
Figure 11. Typical Isolated Output Supply Current, IISO as a Function of
External Load, No Dynamic Current Draw at 5 V/5 V and 3.3 V/3.3 V
Rev. 0 | Page 15 of 24
90% LOAD
10% LOAD
07540-013
DYNAMIC LOAD
0.06
07540-010
OUTPUT CURRENT (A)
0.10
(100µs/DIV)
Figure 14. Typical Transient Load Response 3 V Output 10% to
90% Load Step
07540-011
IDD1 (A) AND POWER DISSIPATION (W)
3.5
ADuM5200/ADuM5201/ADuM5202
20
25
BW = 20MHz
5V IN/5V OUT
3.3V IN/3.3V OUT
16
15
CURRENT (mA)
5V OUTPUT RIPPLE (mV)
20
10
12
8
5
4
–5
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
0
0
4.0
5
TIME (µs)
10
15
DATA RATE (Mbps)
20
25
07540-017
07540-014
0
Figure 18. Typical ICH Supply Current per Reverse Data Channel
(15 pF Output Load)
Figure 15. Typical VISO = 5 V Output Voltage Ripple at 90% Load
5
16
BW = 20MHz
14
5V
CURRENT (mA)
3.3V OUTPUT RIPPLE (mV)
4
3.3V
12
10
8
6
3
2
4
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
25
07540-018
07540-015
0
25
07540-019
1
2
0
0
4.0
5
TIME (µs)
Figure 16. Typical VISO = 3.3 V Output Voltage Ripple at 90% Load
10
15
DATA RATE (Mbps)
20
Figure 19. Typical IISO(D) Dynamic Supply Current per Input
20
3.0
5V IN/5V OUT
3.3V IN/3.3V OUT
2.5
16
5V
CURRENT (mA)
12
8
4
1.5
1.0
0.5
0
0
5
10
15
DATA RATE (Mbps)
20
25
07540-016
CURRENT (mA)
3.3V
2.0
0
0
Figure 17. Typical ICH Supply Current per Forward Data Channel
(15 pF Output Load)
5
15
10
DATA RATE (Mbps)
20
Figure 20. Typical IISO(D) Dynamic Supply Current per Output
(15 pF Output Load)
Rev. 0 | Page 16 of 24
ADuM5200/ADuM5201/ADuM5202
TERMINOLOGY
IDD1(Q)
IDD1(Q) is the minimum operating current drawn at the VDD1 pin
when there is no external load at VISO and the I/O pins are operating below 2 Mbps, requiring no additional dynamic supply
current. IDD1(Q) reflects the minimum current operating
condition.
IDD1(D)
IDD1(D) is the typical input supply current with all channels
simultaneously driven at a maximum data rate of 25 Mbps with
the full capacitive load representing the maximum dynamic
load conditions. Treat resistive loads on the outputs separately
from the dynamic load.
IDD1(MAX)
IDD1(MAX) is the input current under full dynamic and VISO load
conditions.
tPHL Propagation Delay
tPHL propagation delay is measured from the 50% level of the
falling edge of the VIx signal to the 50% level of the falling edge
of the VOx signal.
tPLH Propagation Delay
tPLH propagation delay is measured from the 50% level of the
rising edge of the VIx signal to the 50% level of the rising edge of
the VOx signal.
Propagation Delay Skew (tPSK)
tPSK is the magnitude of the worst-case difference in tPHL and/or
tPLH that is measured between units at the same operating
temperature, supply voltages, and output load within the
recommended operating conditions.
Channel-to-Channel Matching
Channel-to-channel matching is the absolute value of the
difference in propagation delays between the two channels
when operated with identical loads.
Minimum Pulse Width
The minimum pulse width is the shortest pulse width at which
the specified pulse width distortion is guaranteed.
Maximum Data Rate
The maximum data rate is the fastest data rate at which the
specified pulse width distortion is guaranteed.
Rev. 0 | Page 17 of 24
ADuM5200/ADuM5201/ADuM5202
APPLICATIONS INFORMATION
Note that the total lead length between the ends of the low ESR
capacitor and the input power supply pin must not exceed 2 mm.
Installing the bypass capacitor with traces more than 2 mm in
length may result in data corruption. Consider bypassing between
Pin 1 and Pin 8 and between Pin 9 and Pin 16 unless both of the
common ground pins are connected together close to the
package.
BYPASS < 2mm
VDD1
The ADuM520x can accept an external regulation control signal
(RCIN) that can be connected to other isoPower devices. This
allows a single regulator to control multiple power modules
without contention. When accepting control from a master
power module, the VISO pins can be connected together adding
their power. Because there is only one feedback control path, the
supplies work together seamlessly. The ADuM520x can only
regulate itself or accept regulation (slave device) from another
device in this product line; it cannot provide a regulation signal
to other devices.
PCB LAYOUT
The ADuM520x digital isolators with 0.5 W isoPower integrated
dc-to-dc converters require no external interface circuitry for the
logic interfaces. Power supply bypassing is required at the input and
output supply pins (see Figure 21). Note that low ESR bypass
capacitors are required between Pin 1 and Pin 2 and between Pin
15 and Pin 16, as close to the chip pads as possible.
The power supply section of the ADuM520x uses a 180 MHz
oscillator frequency to efficiently pass power through its chip
scale transformers. In addition, normal operation of the data
section of the iCoupler introduces switching transients on the
power supply pins. Bypass capacitors are required for several
operating frequencies. Noise suppression requires a low inductance, high frequency capacitor, whereas ripple suppression and
proper regulation require a large value capacitor. These are most
conveniently connected between Pin 1 and Pin 2 for VDD1 and
between Pin 15 and Pin 16 for VISO. To suppress noise and reduce
ripple, a parallel combination of at least two capacitors is required.
The recommended capacitor values are 0.1 μF and 10 μF for VDD1.
The smaller capacitor must have a low ESR; for example, use of a
ceramic capacitor is advised.
GNDISO
VIA/VOA
VOA/VIA
VIB/VOB
VOB/VIB
RCIN
The ADuM520x implements undervoltage lockout (UVLO) with
hysteresis on the VDD1 power input. This feature ensures that the
converter does not enter oscillation due to noisy input power or
slow power on ramp rates.
A minimum load current of 10 mA is recommended to ensure
optimum load regulation. Smaller loads can generate excess noise on
chip due to short or erratic PWM pulses. Excess noise generated
this way can cause data corruption in some circumstances.
VISO
GND1
NC
VSEL
RCSEL
VE1/NC
VE2/NC
GND1
GNDISO
07540-020
The dc-to-dc converter section of the ADuM520x works on
principles that are common to most power supplies. It has a
secondary side controller architecture with isolated pulse-width
modulation (PWM) feedback. VDD1 power is supplied to an
oscillating circuit that switches current into a chip scale air core
transformer. Power transferred to the secondary side is rectified
and regulated to either 3.3 V or 5 V. The secondary (VISO) side
controller regulates the output by creating a PWM control signal
that is sent to the primary (VDD1) side by a dedicated iCoupler
data channel. The PWM modulates the oscillator circuit to control
the power being sent to the secondary side. Feedback allows for
significantly higher power and efficiency.
Figure 21. Recommended PCB Layout
In applications involving high common-mode transients, ensure
that board coupling across the isolation barrier is minimized.
Furthermore, design the board layout such that any coupling
that does occur equally affects all pins on a given component
side. Failure to ensure this can cause differential voltages
between pins exceeding the absolute maximum ratings for the
device (specified in Table 8) thereby leading to latch-up and/or
permanent damage.
The ADuM520x is a power device that dissipates approximately
1 W of power when fully loaded and running at maximum speed.
Because it is not possible to apply a heat sink to an isolation
device, the device primarily depends on heat dissipation into
the PCB through the GND pins. If the device is used at high
ambient temperatures, provide a thermal path from the GND
pins to the PCB ground plane. The board layout in Figure 21
shows enlarged pads for Pin 2, Pin 8, Pin 9, and Pin 15. Multiple
vias should be implemented from the pad to the ground plane
to significantly reduce the temperature inside the chip. The
dimensions of the expanded pads are at the discretion of the
designer and depend on the available board space.
EMI CONSIDERATIONS
The dc-to-dc converter section of the ADuM520x components
must operate at a very high frequency to allow efficient power
transfer through the small transformers. This creates high
frequency currents that can propagate in circuit board ground
and power planes, causing edge emissions and dipole radiation
between the primary and secondary ground planes. Grounded
enclosures are recommended for applications that use these
devices. If grounded enclosures are not possible, follow good RF
design practices in layout of the PCB. See www.analog.com for the
most current PCB layout recommendations specifically for the
ADuM520x.
Rev. 0 | Page 18 of 24
ADuM5200/ADuM5201/ADuM5202
tPHL
OUTPUT (VOX)
07540-118
tPLH
50%
Figure 22. Propagation Delay Parameters
Pulse width distortion is the maximum difference between these
two propagation delay values and is an indication of how
accurately timing of the input signal is preserved.
Channel-to-channel matching refers to the maximum amount
the propagation delay differs between channels within a single
ADuM520x component.
Propagation delay skew refers to the maximum amount the
propagation delay differs between multiple ADuM520x
components operating under the same conditions.
DC CORRECTNESS AND MAGNETIC FIELD IMMUNITY
Positive and negative logic transitions at the isolator input
cause narrow (~1 ns) pulses to be sent to the decoder via the
transformer. The decoder is bistable and is, therefore, either set
or reset by the pulses, indicating input logic transitions. In the
absence of logic transitions at the input for more than 1 μs, a
periodic set of refresh pulses indicative of the correct input state
are sent to ensure dc correctness at the output. If the decoder
receives no internal pulses of more than about 5 μs, the input
side is assumed to be unpowered or nonfunctional, in which case
the isolator output is forced to a default state (see Table 13) by
the watchdog timer circuit.
The limitation on the magnetic field immunity of the ADuM520x
is set by the condition in which induced voltage in the receiving
coil of the transformer is sufficiently large to either falsely set or
reset the decoder. The following analysis defines the conditions
under which this may occur. The 3 V operating condition of the
ADuM520x is examined because it represents the most susceptible mode of operation.
The pulses at the transformer output have an amplitude greater
than 1.0 V. The decoder has a sensing threshold at about 0.5 V, thus
establishing a 0.5 V margin in which induced voltages can be
tolerated. The voltage induced across the receiving coil is given by
V = (−dβ/dt)∑πrn2; n = 1, 2, … , N
1
0.1
0.01
0.001
1k
100k
10k
1M
10M
MAGNETIC FIELD FREQUENCY (Hz)
100M
Figure 23. Maximum Allowable External Magnetic Flux Density
For example, at a magnetic field frequency of 1 MHz, the
maximum allowable magnetic field of 0.2 kgauss induces a
voltage of 0.25 V at the receiving coil. This is about 50% of the
sensing threshold and does not cause a faulty output transition.
Similarly, if such an event occurs during a transmitted pulse
(and is of the worst-case polarity), it reduces the received pulse
from >1.0 V to 0.75 V—still well above the 0.5 V sensing
threshold of the decoder.
The preceding magnetic flux density values correspond to
specific current magnitudes at given distances from the
ADuM520x transformers. Figure 24 expresses these allowable
current magnitudes as a function of frequency for selected
distances. As shown, the ADuM520x is extremely immune and
can be affected only by extremely large currents operated at
high frequency very close to the component. For the 1 MHz
example noted, a 0.5 kA current placed 5 mm away from the
ADuM520x is required to affect the operation of the
component.
1000
where:
β is the magnetic flux density (gauss).
N is the number of turns in the receiving coil.
rn is the radius of the nth turn in the receiving coil (cm).
DISTANCE = 1m
100
10
DISTANCE = 100mm
1
DISTANCE = 5mm
0.1
0.01
1k
10k
100k
1M
10M
100M
MAGNETIC FIELD FREQUENCY (Hz)
Figure 24. Maximum Allowable Current
for Various Current-to-ADuM520x Spacings
Given the geometry of the receiving coil in the ADuM520x and
an imposed requirement that the induced voltage be, at most,
07540-119
50%
10
Note that at combinations of strong magnetic field and high
frequency, any loops formed by PCB traces can induce error
Rev. 0 | Page 19 of 24
07540-120
INPUT (VIX)
100
MAXIMUM ALLOWABLE MAGNETIC FLUX
DENSITY (kgauss)
Propagation delay is a parameter that describes the time it takes a
logic signal to propagate through a component. The propagation
delay to a logic low output may differ from the propagation delay
to a logic high.
50% of the 0.5 V margin at the decoder, a maximum allowable
magnetic field is calculated as shown in Figure 23.
MAXIMUM ALLOWABLE CURRENT (kA)
PROPAGATION DELAY PARAMETERS
ADuM5200/ADuM5201/ADuM5202
voltages sufficiently large enough to trigger the thresholds of
succeeding circuitry. Exercise care in the layout of such traces
to avoid this possibility.
The preceding analysis assumes a 15 pF capacitive load on each
data output. If the capacitive load is larger than 15 pF, the additional current must be included in the analysis of IDD1 and IISO(LOAD).
POWER CONSUMPTION
To determine IDD1 in Equation 1, additional primary side dynamic
output current (IAOD) is added directly to IDD1. Additional secondary side dynamic output current (IAOD) is added to IISO on a
per channel basis.
The VDD1 power supply input provides power to the iCoupler
data channels as well as to the power converter. For this reason,
the quiescent currents drawn by the data converter and the
primary and secondary input/output channels cannot be
determined separately. All of these quiescent power demands
have been combined into the IDD1(Q) current shown in Figure 25.
The total IDD1 supply current is the sum of the quiescent operating
current, dynamic current IDD1(D) demanded by the I/O channels,
and any external IISO load.
E
IDD1(Q)
IDDP(D)
PRIMARY
DATA I/O
2-CHANNEL
CONVERTER
SECONDARY
IISO(D)
SECONDARY
DATA I/O
2-CHANNEL
07540-021
IDD1(D)
IAOD = 0.5 × 10−3 × (CL − 15) × VISO) × (2f − fr) f > 0.5 fr (3)
CURRENT LIMIT AND THERMAL OVERLOAD
PROTECTION
Figure 25. Power Consumption Within the ADuM520x
Both dynamic input and output current is consumed only when
operating at channel speeds higher than the rate of fr. Because
each channel has a dynamic current determined by its data rate,
Figure 17 shows the current for a channel in the forward direction,
which means that the input is on the primary side of the part.
Figure 18 shows the current for a channel in the reverse direction,
which means that the input is on the secondary side of the part.
Both figures assume a typical 15 pF load. The following relationship allows the total IDD1 current to be calculated:
IDD1 = (IISO × VISO)/(E × VDD1) + ∑ ICHn; n = 1 to 4
(1)
where :
IDD1 is the total supply input current.
ICHn is the current drawn by a single channel determined from
Figure 17 or Figure 18, depending on channel direction.
IISO is the current drawn by the secondary side external loads.
E is the power supply efficiency at 100 mA load from Figure 9 at
the VISO and VDD1 condition of interest.
Calculate the maximum external load by subtracting the
dynamic output load from the maximum allowable load.
IISO(LOAD) = IISO(MAX) − ∑ IISO(D)n; n = 1 to 4
For each output channel with CL greater than 15 pF, the
additional capacitive supply current is given by
where:
CL is the output load capacitance (pF).
VISO is the output supply voltage (V).
f is the input logic signal frequency (MHz); it is half of the input
data rate expressed in units of Mbps.
fr is the input channel refresh rate (Mbps).
IISO
CONVERTER
PRIMARY
To determine IISO(LOAD) in Equation 2, additional secondary side
output current (IAOD) is subtracted from IISO(MAX) on a per
channel basis.
(2)
where:
IISO(LOAD) is the current available to supply an external secondary
side load.
IISO(MAX) is the maximum external secondary side load current
available at VISO.
IISO(D)n is the dynamic load current drawn from VISO by an input
or output channel, as shown in Figure 17 and Figure 18. Data is
presented assuming a typical 15 pF load
The ADuM520x is protected against damage due to excessive
power dissipation by thermal overload protection circuits. Thermal
overload protection limits the junction temperature to a maximum
of 150°C (typical). Under extreme conditions (that is, high ambient temperature and power dissipation), when the junction
temperature starts to rise above 150°C, the PWM is turned off,
reducing the output current to zero. When the junction temperature drops below 130°C (typical), the PWM turns on again,
restoring the output current to its nominal value.
Consider the case where a hard short from VISO to ground
occurs. At first, the ADuM520x reaches its maximum current,
which is proportional to the voltage applied at VDD1. Power
dissipates on the primary side of the converter (see Figure 12).
If self-heating of the junction becomes great enough to cause its
temperature to rise above 150°C, thermal shutdown activates,
turning off the PWM and reducing the output current to zero.
As the junction temperature cools and drops below 130°C, the
PWM turns on and power dissipates again on the primary side
of the converter, causing the junction temperature to rise to
150°C again. This thermal oscillation between 130°C and 150°C
causes the part to cycle on and off as long as the short remains
at the output.
Thermal limit protections are intended to protect the device
against accidental overload conditions. For reliable operation,
externally limit device power dissipation to prevent junction
temperatures from exceeding 130°C.
Rev. 0 | Page 20 of 24
ADuM5200/ADuM5201/ADuM5202
POWER CONSIDERATIONS
The ADuM5200/ADuM5201/ADuM5202 power input, data
input channels on the primary side, and data input channels on
the secondary side are all protected from premature operation by
UVLO circuitry. Below the minimum operating voltage, the
power converter holds its oscillator inactive and all input channel
drivers and refresh circuits are idle. Outputs remain in a high
impedance state to prevent transmission of undefined states
during power-up and power-down operations.
During application of power to VDD1, the primary side circuitry is
held idle until the UVLO preset voltage is reached. At that time,
the data channels initialize to their default low output state until
they receive data pulses from the secondary side.
When the primary side is above the UVLO threshold, the data input
channels sample their inputs and begin sending encoded pulses to
the inactive secondary output channels. The outputs on the primary
side remain in their default low state because no data comes from
the secondary side inputs until secondary power is established. The
primary side oscillator also begins to operate, transferring power to
the secondary power circuits. The secondary VISO voltage is below its
UVLO limit at this point; the regulation control signal from the
secondary is not being generated. The primary side power oscillator
is allowed to free run in this circumstance, supplying the maximum
amount of power to the secondary, until the secondary voltage rises
to its regulation setpoint. This creates a large inrush current transient
at VDD1. When the regulation point is reached, the regulation
control circuit produces the regulation control signal that
modulates the oscillator on the primary side. The VDD1 current is
reduced and is then proportional to the load current. The inrush
current is less than the short-circuit current shown in Figure 12.
The duration of the inrush depends on the VISO loading conditions
and the current available at the VDD1 pin.
As the secondary side converter begins to accept power from the
primary, the VISO voltage starts to rise. When the secondary side
UVLO is reached, the secondary side outputs are initialized to
their default low state until data is received from the corresponding
primary side input. It can take up to 1 μs after the secondary side
is initialized for the state of the output to correlate with the primary side input.
Secondary side inputs sample their state and transmit it to the
primary side. Outputs are valid about 1 μs after the secondary
side becomes active.
Because the rate of charge of the secondary side power supply is
dependent on loading conditions, the input voltage, and the
output voltage level selected, take care with the design to allow
the converter sufficient time to stabilize before valid data is
required.
When power is removed from VDD1, the primary side converter
and coupler shut down when the UVLO level is reached. The
secondary side stops receiving power and starts to discharge. The
outputs on the secondary side hold the last state that they received
from the primary side. Either the UVLO level is reached and the
outputs are placed in their high impedance state, or the outputs
detect a lack of activity from the primary side inputs and the
outputs are set to their default low value before the secondary
power reaches UVLO.
THERMAL ANALYSIS
The ADuM520x consists of four internal die, attached to a split
lead frame with two die attach paddles. For the purposes of
thermal analysis, it is treated as a thermal unit with the highest
junction temperature reflected in the θJA from Table 3. The
value of θJA is based on measurements taken with the part
mounted on a JEDEC standard 4-layer board with fine width
traces and still air. Under normal operating conditions, the
ADuM520x operates at full load across the full temperature
range without derating the output current. However, following
the recommendations in the PCB Layout section decreases the
thermal resistance to the PCB allowing increased thermal margin
at high ambient temperatures.
INCREASING AVAILABLE POWER
The ADuM520x devices are designed with the capability of
running in combination with other compatible isoPower
devices. The RCIN and RCSEL pins allow the ADuM520x to
receive a PWM signal from another device through the RCIN
pin and act as a slave to that control signal. The RCSEL pin
chooses whether the part acts as a standalone self-regulated
device or a slave device. When the ADuM520x is acting as a
slave, its power is regulated by a PWM signal coming from a
master device. This allows multiple isoPower parts to be
combined in parallel while sharing the load equally. When the
ADuM520x is configured as a standalone unit, it generates its
own PWM feedback signal to regulate itself.
The ADuM5000 can act as a master or a slave device, the
ADuM5401, ADuM5402, ADuM5403, and ADuM5404 can
only be master/standalone, and the ADuM520x can only be a
slave/standalone device. This means that the ADuM5000,
ADuM520x, and ADuM5401 to ADuM5404 can only be used
in certain master/slave combinations as listed in Table 14.
Table 14. Allowed Combinations of isoPower Parts
Slave
Master
ADuM5000
ADuM520x
ADuM5401 to
ADuM5404
ADuM5000
Yes
No
Yes
ADuM520x
Yes
No
Yes
ADuM5401 to
ADuM5404
No
No
No
The allowed combinations of master and slave configured parts
listed in Table 14 is sufficient to make any combination of power
and channel count.
Table 15 illustrates how isoPower devices can provide many
combinations of data channel count and multiples of the single
unit power.
Rev. 0 | Page 21 of 24
ADuM5200/ADuM5201/ADuM5202
Table 15. Configurations for Power and Data Channels
Power Units
1-Unit Power
0
ADuM5000 master
Number of Data Channels
2
4
ADuM520x master
ADuM5401 to ADuM5404 master
2-Unit Power
ADuM5000 master
ADuM5000 slave
ADuM5000 master
ADuM5000 slave
ADuM5000 slave
ADuM5000 master
ADuM520x slave
ADuM5000 master
ADuM5000 slave
ADuM520x slave
Analog Devices performs accelerated life testing using voltage
levels higher than the rated continuous working voltage. Acceleration factors for several operating conditions are determined.
These factors allow calculation of the time to failure at the actual
working voltage. The values shown in Table 9 summarize the
peak voltage for 50 years of service life for a bipolar ac operating
condition, and the maximum CSA/VDE approved working voltages. In many cases, the approved working voltage is higher than
a 50-year service life voltage. Operation at these high working
voltages can lead to shortened insulation life in some cases.
The insulation lifetime of the ADuM520x depends on the voltage
waveform type imposed across the isolation barrier. The iCoupler
insulation structure degrades at different rates depending on
whether the waveform is bipolar ac, unipolar ac, or dc. Figure 26,
Figure 27, and Figure 28 illustrate these different isolation
voltage waveforms.
Bipolar ac voltage is the most stringent environment. The goal
of a 50-year operating lifetime under the ac bipolar condition
determines the maximum working voltage recommended by
Analog Devices.
Rev. 0 | Page 22 of 24
RATED PEAK VOLTAGE
07540-121
All insulation structures eventually break down when subjected
to voltage stress over a sufficiently long period. The rate of insulation degradation is dependent on the characteristics of the
voltage waveform applied across the insulation. In addition to the
testing performed by the regulatory agencies, Analog Devices
carries out an extensive set of evaluations to determine the
lifetime of the insulation structure within the ADuM520x.
In the case of unipolar ac or dc voltage, the stress on the insulation is significantly lower. This allows operation at higher working
voltages while still achieving a 50-year service life. The working
voltages listed in Table 9 can be applied while maintaining the
50-year minimum lifetime, provided the voltage conforms to
either the unipolar ac or dc voltage cases. Any cross insulation
voltage waveform that does not conform to Figure 27 or Figure 28
should be treated as a bipolar ac waveform and its peak voltage
limited to the 50-year lifetime voltage value listed in Table 9.
The voltage presented in Figure 27 is shown as sinusoidal for
illustration purposes only. It is meant to represent any voltage
waveform varying between 0 V and some limiting value. The
limiting value can be positive or negative, but the voltage cannot
cross 0 V.
0V
Figure 26. Bipolar AC Waveform
RATED PEAK VOLTAGE
07540-122
INSULATION LIFETIME
0V
Figure 27. Unipolar AC Waveform
RATED PEAK VOLTAGE
07540-123
3-Unit Power
ADuM5401 to ADuM5404 master
ADuM520x slave
ADuM5401 to ADuM5404 master
ADuM5000 slave
ADuM5000 slave
6
ADuM5401 to ADuM5404 master
ADuM121x
ADuM5401 to ADuM5404 master
ADuM520x slave
ADuM5401 to ADuM5404 master
ADuM520x slave
ADuM5000 slave
0V
Figure 28. DC Waveform
ADuM5200/ADuM5201/ADuM5202
OUTLINE DIMENSIONS
10.50 (0.4134)
10.10 (0.3976)
9
16
7.60 (0.2992)
7.40 (0.2913)
8
1.27 (0.0500)
BSC
0.30 (0.0118)
0.10 (0.0039)
COPLANARITY
0.10
0.51 (0.0201)
0.31 (0.0122)
10.65 (0.4193)
10.00 (0.3937)
0.75 (0.0295)
0.25 (0.0098)
2.65 (0.1043)
2.35 (0.0925)
SEATING
PLANE
45°
8°
0°
1.27 (0.0500)
0.40 (0.0157)
0.33 (0.0130)
0.20 (0.0079)
COMPLIANT TO JEDEC STANDARDS MS-013- AA
CONTROLLING DIMENSIONS ARE IN MILLIMETERS; INCH DIMENSIONS
(IN PARENTHESES) ARE ROUNDED-OFF MILLIMETER EQUIVALENTS FOR
REFERENCE ONLY AND ARE NOT APPROPRIATE FOR USE IN DESIGN.
032707-B
1
Figure 29. 16-Lead Standard Small Outline Package [SOIC_W]
Wide Body (RW-16)
Dimensions shown in millimeters and (inches)
ORDERING GUIDE
Model
ADuM5200ARWZ 1, 2
ADuM5200CRWZ1, 2
ADuM5201ARWZ1, 2
ADuM5201CRWZ1, 2
ADuM5202ARWZ1, 2
ADuM5202CRWZ1, 2
1
2
Number of
Inputs,
VDD1 Side
2
2
1
1
0
0
Number of
Inputs,
VDD2 Side
0
0
1
1
2
2
Maximum
Data Rate
(Mbps)
1
25
1
25
1
25
Maximum
Propagation
Delay, 5 V (ns)
100
70
100
70
100
70
Maximum
Pulse Width
Distortion (ns)
40
3
40
3
40
3
Tape and reel are available. The additional -RL suffix designates a 13-inch (1,000 units) tape and reel option.
Z = RoHS Compliant Part.
Rev. 0 | Page 23 of 24
Temperature
Range
−40°C to +105°C
−40°C to +105°C
−40°C to +105°C
−40°C to +105°C
−40°C to +105°C
−40°C to +105°C
Package
Description
16-Lead SOIC_W
16-Lead SOIC_W
16-Lead SOIC_W
16-Lead SOIC_W
16-Lead SOIC_W
16-Lead SOIC_W
Package
Option
RW-16
RW-16
RW-16
RW-16
RW-16
RW-16
ADuM5200/ADuM5201/ADuM5202
NOTES
©2008 Analog Devices, Inc. All rights reserved. Trademarks and
registered trademarks are the property of their respective owners.
D07540-0-10/08(0)
Rev. 0 | Page 24 of 24