FILTRONIC FRD3500X230

PRELIMINARY
FRD3500X230
3.5 GHZ WIMAX REFERENCE DESIGN (1 W)
•
PERFORMANCE (3.5 GHz)
(802.16-2004 WiMAX Modulation)
♦ 30 dBm Typical Output Power, < 2.5% EVM
♦ 14 dB Typical Small-Signal Gain
♦ Class B Efficiency 14% (8V / 720 mA IDQ)
♦ > 48 dBm 3rd Order Intercept Point
♦ Low total components count
•
DESCRIPTION AND APPLICATIONS
DEMO BOARD SIZE: 1 x 2 in. (2.54 x 5.08 cm.)
CONNECTORIZED VERSION SHOWN
The FRD3500X230 is a 2-stage, connectorized Reference Design that delivers a typical linear power
of 30 dBm with the 802.16-2004 modulation, while maintaining less than 2.5% EVM. The design
features a FPD4000AS driver stage, followed by a FPD10000AF power output stage. Both stages
are dual-biased to allow a range of bias conditions on each stage, allowing operation from Class B to
Class A. Board layout and components list are included.
•
ELECTRICAL SPECIFICATIONS AT 22°C
Parameter
Symbol
Test Conditions
Min
Operating Bandwidth
BW
Class A / AB / B
200
MHz
Small Signal Gain
SSG
Class A: VDS = 10V; IDQ = 1.6 A
14
dB
Gain Flatness
∆G
Class A: VDS = 10V; IDQ = 1.6 A
± 1.5
dB
Center Frequency (adjustable)
fCEN
Nominal bias conditions
Power at 1dB Gain Compression
P1dB
VDS = 10V; IDQ = 1.6 A
37.5
dBm
G1dB
VDS = 10V; IDQ = 1.6 A
13
dB
Channel Power with 802.16-2004
2.5% max. EVM
PCH
Class AB Mode
31.0
31.5
dBm
Channel Power with 802.16-2004
2.5% max. EVM
PCH
29
30
dBm
Power-Added Efficiency
Eff
Class AB Mode
10
%
Class B Mode
14
3.4
Typ
3.5
Max
Units
3.6
Class A - CW Single Tone
Power Gain at dB Gain Compression
Class A - CW Single Tone
VDS = 10 V; IDQ = 1.25 A
Class B Mode
VDS = 8 V; IDQ = 730 mA typ.
802.16-2004 modulation
Operating Current at 30 dBm PCH
IOP
VDD = 8.0 V; VGG = -1.20 / -0.89 V
0.9
A
Nominal Drain Supply
VDD
All operating conditions
Nominal Gate Voltages
VGG
For Class B Operation
Total DC Power (operating)
Phone: +1 408 850-5790
Fax: +1 408 850-5766
PTOT
8
V
st
-1.2
V
nd
VGG2 (2 Stage)
-0.89
V
Class B at PCH = 30 dBm
7.0
W
VGG1 (1 Stage)
http:// www.filtronic.co.uk/semis
Revised: 8/10/05
Email: [email protected]
PRELIMINARY
FRD3500X230
3.5 GHZ WIMAX REFERENCE DESIGN (1 W)
•
RECOMMENDED OPERATING BIAS CONDITIONS
Drain-Source Voltage:
From 8V to 10V
Quiescent Current:
From 700mA (Class B) to 1.6A (Class A)
•
ABSOLUTE MAXIMUM RATINGS1
Parameter
Symbol
Test Conditions
Drain Supply Voltage
VDD
Gate Supply Voltage
Max
Units
-3V < VGS < +0V
12
V
VGG
0V < VDD < +8V
-3
V
Operating Current
IOP
For VDS > 2V
1.8
A
Gate Current
IG
Forward or reverse current
+60/-15
mA
RF Input Power
2
PIN
Under any acceptable bias state
500
mW
Channel Operating Temperature
TCH
Under any acceptable bias state
175
ºC
Storage Temperature
TSTG
Non-Operating Storage
150
ºC
Total Power Dissipation
PTOT
Ambient temperature to 85ºC
12
W
Comp.
Under any bias conditions
5
dB
2 or more Max. Limits
80
%
Gain Compression
3
Simultaneous Combination of Limits
1
3
Min
TAmbient = 22°C unless otherwise noted
-40
2
Max. RF Input Limit must be further limited if input VSWR > 2.5:1
Users should avoid exceeding 80% of 2 or more Limits simultaneously
Notes:
• Operating conditions that exceed the Absolute Maximum Ratings could result in permanent damage to the devices.
•
HANDLING PRECAUTIONS
To avoid damage to the devices care should be exercised during handling. Proper Electrostatic
Discharge (ESD) precautions should be observed at all stages of storage, handling, assembly, and
testing. This product has be tested to Class 1A (> 250V but < 500V) using JESD22 A114, Human
Body Model, and to Class A, (< 200V) using JESD22 A115, Machine Model..
•
APPLICATIONS NOTES & DESIGN DATA
Recommendations on matching circuits is available from your local Filtronic Sales Representative or
directly from the factory. User must ensure that proper bias sequencing is observed: Gate bias
must be applied before Drain bias, and during power-down the Drain bias must be removed
first.
Phone: +1 408 850-5790
Fax: +1 408 850-5766
http:// www.filtronic.co.uk/semis
Revised: 8/10/05
Email: [email protected]
PRELIMINARY
FRD3500X230
3.5 GHZ WIMAX REFERENCE DESIGN (1 W)
•
TYPICAL SMALL-SIGNAL PERFORMANCE:
•
TYPICAL CLASS AB / B CW PERFORMANCE:
Table 2 Linearity under Class AB bias condition
Phone: +1 408 850-5790
Fax: +1 408 850-5766
http:// www.filtronic.co.uk/semis
Revised: 8/10/05
Email: [email protected]
PRELIMINARY
FRD3500X230
3.5 GHZ WIMAX REFERENCE DESIGN (1 W)
TYPICAL CLASS A CW PERFORMANCE:
Table 1 Power Sweep under Class A bias condition
Phone: +1 408 850-5790
Fax: +1 408 850-5766
http:// www.filtronic.co.uk/semis
Revised: 8/10/05
Email: [email protected]
PRELIMINARY
FRD3500X230
3.5 GHZ WIMAX REFERENCE DESIGN (1 W)
All information and specifications are subject to change without notice.
Phone: +1 408 850-5790
Fax: +1 408 850-5766
http:// www.filtronic.co.uk/semis
Revised: 8/10/05
Email: [email protected]