SLPOWER CINT1275A2414K01

CINT1275
275W Single Output
Industrial Series
Features

3” x 5” x 1.38” Package

Up to 275W of AC-DC Power

For 1U Applications

Universal Input 90-264 Vac Input Range

Standby and Fan Output Voltages

Forced Current Share

Inhibit, Power Fail, Output OK Signals

Approved to CSA/EN/IEC/UL60950-1, 2nd
Edition

Efficiency 92% typical

3 Year Warranty

RoHS Compliant
Description
A Superior performance 275 Watts AC to DC power supply designed for industrial and ITE applications. Feature rich and
highly efficient CINT1275 product family with active current share for redundant applications can easily fit in 1U chassis
and provides 180 Watts for convection or 275 Watts with moving air. Input & output monitoring alarms plus isolated
12V/1A fan output and 5V standby voltage are among other standard offering of CINT1275 family. All 5 models are CE
marked to low voltage directive and approved to ITE standards of EN60950, 2nd edition.
Model Selection
Model
Number
Volts
Fan Output
Ripple &
Noise**
Total
Regulation
OVP
Threshold***
CINT1275A1214K01
12V
21.8A
15.0A
12Vdc/1A
120mV pk-pk
3%
14.0  1.1V
CINT1275A1514K01
15V
18.3A
12.0A
12Vdc/1A
150mV pk-pk
3%
19.5 ± 1.5V
CINT1275A2414K01
24V
10.9A
7.50A
12Vdc/1A
240mV pk-pk
3%
28.0 ± 2.5V
CINT1275A4814K01
48V
5.46A
3.75A
12Vdc/1A
480mV pk-pk
3%
55.0 ± 4.0V
CINT1275A5614K01
56V
4.68A
3.21A
12Vdc/1A
560mV pk-pk
3%
59.0 ± 1.0V
Notes:
Output Current
w/200LFM air
Convection*
* Total convection power is 180 Watts.
** Measured with noise probe directly across output terminals, and load terminated with 0.1μF ceramic and 10μF low ESR capacitors.
*** No output adjustment on 56V.
General Specifications
AC Input
Input Current
Inrush Current
www.slpower.com
100-240Vac, ±10%, 47-63Hz, 1
120–370Vdc
Turn On Time
Less than 2 sec. @115Vac (inversely
proportional to input voltage and thermistor
temperature)
115Vac: 3A, 230Vac: 1.5A
3.7A max. at 90Vac
Hold-up Time
16mS at 250W, 120Vac/60Hz
264Vac, cold start: will not exceed 50A
Overtemperature
Protection
CINT1275 REV 1.2 15-JAN-13
Sensing transformer temperature, 135°C (55°C
ambient temperature at full load), latching type.
1
CINT1275
275W Single Output
Industrial Series
General Specifications (continued)
Input Fuses
Earth Leakage
Current
Efficiency
Output Power
Transient
Response
Ripple and Noise
Output Voltage
Voltage
Adjustability
Minimum Load
F1, F2: 5A, 275Vac fuses provided on all
models
Short Circuit
Protection
<750μA@264Vac, 60Hz, NC
Overvoltage
Protection
92% typical
275W continuous, with 200 lfm airflow, 180W
convection cooled – See chart for specific
voltage model ratings.
Isolation
120 to 150% of rating, Hiccup Mode
Hiccup Mode, auto recovery.
OVP latch at 110 to 130% of output voltage
PFC: Variable, 30kHz - 400kHz
Main Converter: Variable 30-250kHz, 6570kHz at full load.
Input-Output: 4000Vac
Input-Ground: 1800Vac
Output-Ground: 1500Vac
0.5%rms, 1% pk-pk, see chart.
Operating
Temperature
-10°C to +70°C
Start Up at -40°C, full load
See chart
Temperature
Derating
Derate output power linearly above 50°C to
50% at 70°C
+/-5% from nominal (except 56V)
Storage Temperature
Altitude
Not required
+/- 3% combined line, load and initial setting.
Vibration
Operating: 0.003g/Hz, 1.5grms overall, 3
axes, 10 min/axis
Non-Operating: 0.026g2/Hz, 5.0grms overall,
3 axes, 1 hr/axis
Weight
Switching Frequency
500µS typical, return to 0.5% of nominal, 50%
load step. i/t: <0.2A/μS. Max Voltage
Deviation = 3%
Total Regulation
Dimensions
Overload Protection
W: 3.0” x L: 5.0” x H: 1.38” (from bottom of PC
Board).
Relative Humidity
Shock
Safety Standards
MTBF
325g
-40°C to +85°C
Operating: -500 to 10,000 ft.
Non-operating: -500 to 40,000 ft.
5% to 95%, non-condensing
Operating: Half-sine, 20gpk, 10ms, 3 axes, 6
shocks total
Non-Operating: Half-sine, 40 gpk, 10 ms, 3
axes, 6 shocks total
EN/CSA/UL/IEC 60950-1, 2nd Edition
465,000 hours, 275W load, 110Vac input,
25°C ambient
Auxiliary Signals
AC Power Fail:
Goes LOW with 5mS warning before loss of
DC output after loss of AC power.
DC OK:
Inhibit:
Connect to inhibit pin (J201 pin 5) to output
common to inhibit the DC output.
Fan Output:
Remote Sense:
Compensates for up to 250mV drop in load
lines.
Current Share:
www.slpower.com
CINT1275 REV 1.2 15-JAN-13
Open collector logic signal goes and stays HIGH
100mS to 500mS after main output reaches
regulation.
12V @ 1A
Forced Current Sharing provided for up to 5
units connected in parallel.
2
CINT1275
275W Single Output
Industrial Series
EMI/EMC Compliance
Conducted Emissions
EN55011/22 Class B, FCC Part 15, Subpart B, Class B
Radiated Emissions
EN55011/22 Class A, FCC Part 15, Subpart B, Class A w/6db margin
Static Discharge Immunity
EN61000-4-2, 6kV Contact Discharge, 8kV air discharge
Radiated RF Immunity
EN61000-4-3, 3V/m.
EFT/Burst Immunity
EN61000-4-4, 2kV/5kHz
Line Surge Immunity
EN61000-4-5, 1kV differential, 2kV common-mode
Conducted RF Immunity
EN61000-4-6, 3Vrms
Power Frequency Magnetic Field Immunity
EN61000-4-8, 3A/m
Voltage Dip Immunity
EN61000-4-11, 100%, 10ms; 30%, 275ms; 60%, 100ms; Performance
Criteria A, A, & A at 70% load.
Line Harmonic Emissions
EN61000-3-2, Class A, B, C, & D
Flicker Test
EN61000-3-3, Complies (dmax<6%)
Mechanical Drawing
Airflow Direction
Notes:
1. All dimensions in inches (mm), tolerance is +/-0.02”.
2. Mounting holes should be grounded for EMI purposes.
3. FG is safety ground connection.
4. The power supply requires mounting on metal standoffs 0.20” (5mm) in height, min.
Connector Information
Input Connector
Ground
DC Output
Connector
Fan Output
Connector
Signal Connector
PIN 1) AC LINE
PIN 2) EMPTY
PIN 3) AC NEUTRAL
0.25” FASTON
TAB
Term. 1: +Vout
Term. 2: -Vout
PIN 1) +12V fan RTN
PIN 2) +12V fan
PIN 1) Remote Sense (+)
PIN 2) Common
PIN 3) Remote Sense (-)
PIN 4) Current Share
PIN 5) Inhibit
Mating Connector:
Molex 09-50-3031
Pins: 08-52-0072
Mating Connector:
Molex 0190020001
Mating Connector:
Molex 191410058/0063/0083
Mating Connector:
Molex 22-01-3027
Pins: 08-50-0114
Mating Connector:
Molex 90119-0010
Pins: 90119-2110
www.slpower.com
CINT1275 REV 1.2 15-JAN-13
or
Pin 6) Common
Pin 7) Power Good
Pin 8) +5Vsb
Pin 9) DC OK
Pin 10) +5Vsb RTN
AMP 87977-3
Pins: 87309-8
3
CINT1275
275W Single Output
Industrial Series
Fan Output – J301
J301 provides a 12V@1A output to support a system cooling fan. The fan output is always available when AC input is
present, so it also can be used for a 12V standby output is so desired.
AC Power Failure/DC OK Current Share and Inhibit Signals – J201
Note:
Because Power Fail and DC OK use the same pin, the signals can
be monitored as follows:
DC OK: When J201-Pin 9 is HIGH
AC Power Fail: When J201-Pin 9 is LOW
2.
Inhibit
Remote inhibit control of the DC output.
J201 pin 5 open
J201 pin 5 LOW or GND
= ON
= OFF
Figure 2: Inhibit Circuit
3.
Vo+
Current Sharing/Remote Sense
The outputs of N+1 (N=1,2…5) models can be shared. It is shown in Figure 3, one
load-share controller is required for each model and circuits are identical when
N+ 1 identical models are used.
J302
J303
Power Supply 1
Terminals J302 and J303 are connected to the Vo+ and Vo-, respectively, of the
first power model. The Vo+ and Vo- correspond to the other models positive and
negative output pins. The Vo+ connects to positive output bus to the load and Voconnects the negative output bus to the load.
The J201 pin1 and pin3 connects to the S+ and S-, respectively, of the first power
models. The S+ and S- correspond to the other models J201 pin1 and pin3. The
S+ connects to positive output bus and S- connects to negative output bus.
Vo-
J201 pin 1
J201 pin 3
S+
S-
J201 pin 4
J302
Load -
J303
Power Supply 2
Remote Sense < 250mV drop compensation:
The J201 Pin4 connects to current sharing bus that it connects to
other models J201 pin4.
J201 pin 1
J201 pin 3
S+
Load +
S-
J201 pin 4
J302
J303
Power Supply 3
Figure 3: Current Share Method
J201 pin 1
J201 pin 3
S+
S-
J201 pin 4
Current Sharing Bus
www.slpower.com
CINT1275 REV 1.2 15-JAN-13
4
CINT1275
275W Single Output
Industrial Series
Timing Sequence
Isolation Specifications
Parameter
Conditions/Description
Insulation Safety Rating
Input/Ground
Input/Output
Output/Ground
Electric Strength Test Voltage
Input/Ground
Input/Output
Output/Ground
Min
Nom
Max
Units
-
-
Vac
Vac
Vac
Min
Nom
Max
Units
90
115/230
264
Vac
Basic
Reinforced
n/a
1800
4000
1500
Input Specifications
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.
Parameter
Conditions/Description
Input Voltage
Turn-On Input Voltage
Ramping up
80
Turn-Off Input Voltage
Ramping down
75
Input Frequency
Vac
Vac
47
50/60
63
Hz
A
Inrush Current Limitation
264Vac, cold start
-
-
50
Power Factor
Vi nom, Io nom
0.9
-
-
Efficiency
Vi nom, Io nom
CINT1275A1214K01
CINT1275A1514K01
CINT1275A2414K01
CINT1275A4814K01
CINT1275A5614K01
-
92%
-
www.slpower.com
CINT1275 REV 1.2 15-JAN-13
%
5
CINT1275
275W Single Output
Industrial Series
Output Specifications
Parameter
Conditions/Description
Min
Nom
Max
Units
Output Voltage Setpoint Accuracy
CINT1275A1214K01
Vi nom,, Io1 @ ADC, TC = 25 °C
-3
-
3
% Vo nom
Output Voltage Setpoint Accuracy
CINT1275A1514K01
Vi nom,, Io1 @ ADC, TC = 25 °C
-3
-
3
% Vo nom
Output Voltage Setpoint Accuracy
CINT1275A2414K01
Vi nom,, Io1 @ ADC, TC = 25 °C
-3
-
3
% Vo nom
Output Voltage Setpoint Accuracy
CINT1275A4814K01
Vi nom,, Io1 @ ADC, TC = 25 °C
-3
-
3
% Vo nom
Output Voltage Setpoint Accuracy
CINT1275A5614K01
Vi nom,, Io1 @ ADC, TC = 25 °C
-3
-
3
% Vo nom
Output Current V1
Output Current V2
CINT1275A1214K01
0
0
15.0
-
21.83
1.0
ADC
ADC
Output Current V1
Output Current V2
CINT1275A1514K01
0
0
12.0
-
17.47
1.0
ADC
ADC
Output Current V1
Output Current V2
CINT1275A2414K01
0
0
7.5
-
10.92
1.0
ADC
ADC
Output Current V1
Output Current V2
CINT1275A4814K01
0
0
3.75
-
5.46
1.0
ADC
ADC
Output Current V1
Output Current V2
CINT1275A5614K01
0
0
3.21
-
4.68
1.0
ADC
ADC
Static Line Regulation V1
Vi min-Vi max, Vi nom, 0-100% Io nom
-1
-
1
% Vo nom
Static Load Regulation V1
(Droop Characteristic)
Vi min-Vi max, Vi nom, 0-100% Io nom
-3
-
3
% Vo nom
Hold-Up Time
Starting at Vi = 230 VAC, Po nom
-
16
-
ms
Dynamic Load Regulation
Load change =50%, di/dt =0.2A/μS
voltage deviation 3%
0
Vi nom, Io nom
0
Start-Up Time
3
-
% Vo nom
2
s
Max
Units
KV (CM)
Protection
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted
Parameter
Conditions/Description
Min
Nom
Input Fuse
Not user accessible
Input Transient Protection
2KV(CM) and 1KV(DM) surge
2
No-load and short circuit proof
Hiccup
Output
short circuit proof
Hiccup
overload (latch style)
Hiccup
Overvoltage Protection
Latch style
Latch
Over temperature Protection
Automatic power shutdown at TC =135°C
www.slpower.com
CINT1275 REV 1.2 15-JAN-13
6
CINT1275
275W Single Output
Industrial Series
Characteristic Curves
Output vs. Temperature
180W convection cooled and 275W continuous with 200 LFM airflow, derate output power to 50% at 70C.
Efficiency vs. Loading
The high efficiency is achieved by using LLC technology with CCM mode PFC topology, and synchronous rectifiers on the output in all of this family
models, minimizing switching losses.
www.slpower.com
CINT1275 REV 1.2 15-JAN-13
7
CINT1275
275W Single Output
Industrial Series
Noise & Ripple
To verify that the output ripple and noise does not exceed the level specified in the product specification. Measured using a scope probe socket with
0.1uF ceramic and a 10uF electrolysis capacitor connected in parallel across it, BW limit with 20MHz.
12V OUT, NO LOAD, 115VAC, 60HZ
12V OUT, FULL LOAD, 115VAC, 60HZ
12V OUT, NO LOAD, 230VAC, 60HZ
12V OUT, FULL LOAD, 230VAC, 60HZ
Output Transient Response
50% load step within the regulation limits of minimum and maximum load, dI/dt< 0.2A/μSec. Recovery time not specified as there is no laps in regulation
with a 50% Load Step. Maximum voltage deviation is 3%, This test is performed on the MAIN OUTPUT ONLY.
12V OUT, 115VAC, 25% TO 75% LOAD STEP
www.slpower.com
12V OUT, 230VAC, 25% TO 75% LOAD STEP
CINT1275 REV 1.2 15-JAN-13
8
CINT1275
275W Single Output
Industrial Series
Output Overload Characteristic
Supply shall protect itself against Overload conditions. The Power Supply shall recover from Overload Conditions without operator intervention.
12V OUT, 90VAC
12V OUT, 264VAC
Turn-On Time
12V OUT, NO LOAD, 90VAC
12V OUT, FULL LOAD, 90VAC
12V OUT, NO LOAD, 264VAC
12V OUT, FULL LOAD, 264VAC
Data Sheet © 2013 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for
consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
www.slpower.com
CINT1275 REV 1.2 15-JAN-13
9