MEANWELL CLG-100-48

CLG-100
100W Single Output Switching Power Supply
series
Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in active PFC function
IP67 design for indoor or outdoor installations
UL1310 Class 2 power unit
Cooling by free air convection
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
3 years warranty (Note.7)
110
F
M
EQUIVALENT
MODEL
DC VOLTAGE
CLG-100-15
CLG-100-20
CLG-100-24
CLG-100-27
CLG-100-36
CLG-100-48
15V
20V
24V
27V
36V
48V
7.5 ~ 15V
10 ~ 20V
12 ~ 24V
18 ~ 36V
24 ~ 48V
2.65A
2A
Note.6 5A
5A
4.8A
4A
CURRENT RANGE
Note.6 0 ~ 5A
0 ~ 5A
0 ~ 4.8A
0 ~ 4A
0 ~ 3.55A
0 ~ 2.65A
0 ~ 2A
RATED POWER
Note.6 60W
75W
96W
96W
95.85W
95.4W
96W
150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
200mVp-p
VOLTAGE ADJ. RANGE
Fixed. Can be modified between 0% ~ -15% rated output voltage
CURRENT ADJ. RANGE
Fixed. Can be modified between 3% ~ -25% rated output current
VOLTAGE TOLERANCE Note.3
3.0%
LINE REGULATION
1.0%
HOLD UP TIME (Typ.)
60ms / 230VAC
3.0%
3.0%
2.0%
2.0%
Note.5 90 ~ 264VAC
1200ms, 80ms / 115VAC at full load
30ms / 115VAC at full load
127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR
PF>0.95/230VAC
EFFICIENCY (Typ.)
83%
AC CURRENT
INRUSH CURRENT(max.)
12V:0.8A/115VAC 0.4A/230VAC
COLD START 40A/230VAC
PF>0.95/115VAC at full load
85%
87%
87%
15V:0.9A/115VAC
87%
0.45A/230VAC
87%
20V ~ 48V:1.1A/115VAC
87%
0.55A/230VAC
0.5mA / 240VAC
95 ~ 100%
OVER CURRENT
Note.4
SHORT CIRCUIT
Note.4 Hiccup mode, recovers automatically after fault condition is removed
Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
13 ~ 16V
16.5 ~ 20V
22 ~ 27V
27 ~ 34V
29 ~ 36V
39 ~ 48V
52 ~ 64V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
90
10
(RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
-30 ~ +70
(Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +80
0.03%/
, 10 ~ 95% RH
(0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL1310 Class 2, UL879 ( listed in UL Sign Components Manual (SAM) ), TUV EN60950-1, EN61347-1, EN61347-2-13
CAN/CSA C22.2 No. 223-M91(except for 48V), IP67 approved
I/P-O/P:3.75KVAC
I/P-FG:1.88KVAC
O/P-FG:1.5KVAC
ISOLATION RESISTANCE
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
EMI CONDUCTION & RADIATION Compliance to EN55015, EN55022 (CISPR22) Class B
Compliance to EN61000-3-2 Class C (>50% load) ; EN61000-3-3
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
NOTE
3.0%
2.0%
1200ms, 80ms / 230VAC
OVER TEMPERATURE
OTHERS
3.0%
SETUP, RISE TIME
LEAKAGE CURRENT
EMC
IP67
RATED CURRENT
VOLTAGE RANGE
SAFETY &
( except for 48V )
13.5 ~ 27V
3.55A
LOAD REGULATION
PROTECTION
( for 48V only)
12V
RIPPLE & NOISE (max.) Note.2 150mVp-p
INPUT
LPS
CLG-100-12
CONSTANT CURRENT REGION Note.8 6 ~ 12V
OUTPUT
SELV
M
SPECIFICATION
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, light industry level (surge 4KV), criteria A
301Khrs min. MIL-HDBK-217F (25
222*68*39mm (L*W*H)
1.0Kg; 12pcs/13Kg/0.49CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to OLP characteristics.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. This is the maximum possible output current and power, over load protection may be activated slightly below this level to comply with the requirement
of UL1310 class 2.
7. 3 years warranty is guaranteed for operating ambient temperature no higher than 68 .
8. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
File Name:CLG-100-SPEC 2008-12-10
CLG-100
100W Single Output Switching Power Supply
Mechanical Specification
Case No. 954A
series
Unit:mm
222.2
198.2
12
9.4
9.6
34.2
300 20
+V(Red)
-V(Black)
68
300 20
AC/L(Brown)
AC/N(Blue)
FG (Greed/Yellow)
18AWG 2C
9.4
18AWG 3C
38.75
4.2 4PL
Block Diagram
Fosc : 100KHz
EMI FILTER
&
RECTIFIERS
I/P
PFC
CIRCUIT
RECTIFIERS
&
FILTER
POWER
SWITCHING
+V
-V
O.L.P.
FG
O.L.P.
DETECTION
CIRCUIT
PWM & PFC
CONTROL
PFC
CONTROL
O.V.P.
Derating Curve
Static Characteristics
fosc : 100KHz
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-30
-25
-5
0
15
30
50
AMBIENT TEMPERATURE ( )
60
70
(HORIZONTAL)
60
50
40
90
100
125
135
145
155 165
175
180
200
230
264
INPUT VOLTAGE (V) 60Hz
File Name:CLG-100-SPEC 2008-12-10