CLG-100 100W Single Output Switching Power Supply series Features : Universal AC input / Full range Protections: Short circuit / Overload / Over voltage / Over temperature Built-in active PFC function IP67 design for indoor or outdoor installations UL1310 Class 2 power unit Cooling by free air convection 100% full load burn-in test High reliability Suitable for LED lighting and moving sign applications 3 years warranty (Note.7) 110 F M EQUIVALENT MODEL DC VOLTAGE CLG-100-15 CLG-100-20 CLG-100-24 CLG-100-27 CLG-100-36 CLG-100-48 15V 20V 24V 27V 36V 48V 7.5 ~ 15V 10 ~ 20V 12 ~ 24V 18 ~ 36V 24 ~ 48V 2.65A 2A Note.6 5A 5A 4.8A 4A CURRENT RANGE Note.6 0 ~ 5A 0 ~ 5A 0 ~ 4.8A 0 ~ 4A 0 ~ 3.55A 0 ~ 2.65A 0 ~ 2A RATED POWER Note.6 60W 75W 96W 96W 95.85W 95.4W 96W 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p VOLTAGE ADJ. RANGE Fixed. Can be modified between 0% ~ -15% rated output voltage CURRENT ADJ. RANGE Fixed. Can be modified between 3% ~ -25% rated output current VOLTAGE TOLERANCE Note.3 3.0% LINE REGULATION 1.0% HOLD UP TIME (Typ.) 60ms / 230VAC 3.0% 3.0% 2.0% 2.0% Note.5 90 ~ 264VAC 1200ms, 80ms / 115VAC at full load 30ms / 115VAC at full load 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR PF>0.95/230VAC EFFICIENCY (Typ.) 83% AC CURRENT INRUSH CURRENT(max.) 12V:0.8A/115VAC 0.4A/230VAC COLD START 40A/230VAC PF>0.95/115VAC at full load 85% 87% 87% 15V:0.9A/115VAC 87% 0.45A/230VAC 87% 20V ~ 48V:1.1A/115VAC 87% 0.55A/230VAC 0.5mA / 240VAC 95 ~ 100% OVER CURRENT Note.4 SHORT CIRCUIT Note.4 Hiccup mode, recovers automatically after fault condition is removed Protection type : Constant current limiting, recovers automatically after fault condition is removed OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE 13 ~ 16V 16.5 ~ 20V 22 ~ 27V 27 ~ 34V 29 ~ 36V 39 ~ 48V 52 ~ 64V Protection type : Shut down and latch off o/p voltage, re-power on to recover 90 10 (RTH2) Protection type : Shut down o/p voltage, re-power on to recover -30 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +80 0.03%/ , 10 ~ 95% RH (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL1310 Class 2, UL879 ( listed in UL Sign Components Manual (SAM) ), TUV EN60950-1, EN61347-1, EN61347-2-13 CAN/CSA C22.2 No. 223-M91(except for 48V), IP67 approved I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:1.5KVAC ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH EMI CONDUCTION & RADIATION Compliance to EN55015, EN55022 (CISPR22) Class B Compliance to EN61000-3-2 Class C (>50% load) ; EN61000-3-3 HARMONIC CURRENT EMS IMMUNITY MTBF DIMENSION PACKING NOTE 3.0% 2.0% 1200ms, 80ms / 230VAC OVER TEMPERATURE OTHERS 3.0% SETUP, RISE TIME LEAKAGE CURRENT EMC IP67 RATED CURRENT VOLTAGE RANGE SAFETY & ( except for 48V ) 13.5 ~ 27V 3.55A LOAD REGULATION PROTECTION ( for 48V only) 12V RIPPLE & NOISE (max.) Note.2 150mVp-p INPUT LPS CLG-100-12 CONSTANT CURRENT REGION Note.8 6 ~ 12V OUTPUT SELV M SPECIFICATION Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, light industry level (surge 4KV), criteria A 301Khrs min. MIL-HDBK-217F (25 222*68*39mm (L*W*H) 1.0Kg; 12pcs/13Kg/0.49CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Please refer to OLP characteristics. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. This is the maximum possible output current and power, over load protection may be activated slightly below this level to comply with the requirement of UL1310 class 2. 7. 3 years warranty is guaranteed for operating ambient temperature no higher than 68 . 8. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. File Name:CLG-100-SPEC 2008-12-10 CLG-100 100W Single Output Switching Power Supply Mechanical Specification Case No. 954A series Unit:mm 222.2 198.2 12 9.4 9.6 34.2 300 20 +V(Red) -V(Black) 68 300 20 AC/L(Brown) AC/N(Blue) FG (Greed/Yellow) 18AWG 2C 9.4 18AWG 3C 38.75 4.2 4PL Block Diagram Fosc : 100KHz EMI FILTER & RECTIFIERS I/P PFC CIRCUIT RECTIFIERS & FILTER POWER SWITCHING +V -V O.L.P. FG O.L.P. DETECTION CIRCUIT PWM & PFC CONTROL PFC CONTROL O.V.P. Derating Curve Static Characteristics fosc : 100KHz 100 100 90 80 80 70 LOAD (%) LOAD (%) 60 40 20 -30 -25 -5 0 15 30 50 AMBIENT TEMPERATURE ( ) 60 70 (HORIZONTAL) 60 50 40 90 100 125 135 145 155 165 175 180 200 230 264 INPUT VOLTAGE (V) 60Hz File Name:CLG-100-SPEC 2008-12-10