CLG-150 150W Single Output Switching Power Supply series Features : Universal AC input / Full range (up to 280VAC) Protections: Short circuit / Overload / Over voltage / Over temperature Built-in active PFC function Cooling by free air convection OCP point adjustable through output cable or internal potential meter Suitable for LED lighting and moving sign applications IP65 design for indoor or outdoor installations 3 years warranty F 110 SELV EQUIVALENT CLG-150-12 A IP65 ( for A,B type only ) A : IP65 rated. Output voltage and constant current level can be adjusted through internal potential meter. B : IP65 rated. Constant current level adjustable through output cable. (Optional) C : Terminal block for I/O connection. Output voltage and constant current level can be adjusted through internal potential meter. (Optional) SPECIFICATION MODEL DC VOLTAGE CLG-150-12 CLG-150-15 CLG-150-20 CLG-150-24 CLG-150-30 CLG-150-36 CLG-150-48 12V 15V 20V 24V 30V 36V 48V 7.5 ~ 15V 10 ~ 20V 12 ~ 24V 18 ~ 36V 24 ~ 48V 4.2A 3.2A CONSTANT CURRENT REGION Note.4 6 ~12V OUTPUT RATED CURRENT 11A 9.5A 7.5A 6.3A 15 ~ 30V 5A RATED POWER 132W 142.5W 150W 151.2W 150W 151.2W 153.6W RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p VOLTAGE ADJ. RANGE Note.6 9 ~ 13V 13 ~ 17V 17 ~ 22V 22 ~ 27V 26 ~ 32V 31 ~ 41V 40 ~ 56V 2.5 ~ 5A 2.1 ~ 4.2A 1.6 ~ 3.2A Can be adjusted by internal potential meter or through output cable CURRENT ADJ. RANGE 5.5 ~ 11A 3.15 ~ 6.3A 2.0% 2.0% 1.0% 1.0% 1.0% 1.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 3000ms, 80ms at full load 50ms / 230VAC HOLD UP TIME (Typ.) VOLTAGE RANGE Note.5 90 ~ 280VAC 230VAC /115VAC 16ms / 115VAC at full load 127 ~ 396VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR PF 0.95/230VAC EFFICIENCY (Typ.) 88% AC CURRENT INRUSH CURRENT(max.) 2A / 115VAC 1A / 230VAC COLD START 65A/230VAC PF 0.98/115VAC at full load and rated output voltage 88% 90% 90% 90% LED-Load : CC-mode max. 105% CV-mode max. 110% Electronic-Load : CC-mode max. 110% OVER CURRENT Note.4 SHORT CIRCUIT Note.8 Hiccup mode, recovers automatically after fault condition is removed 90% CV-mode max. 105% Protection type : Constant current limiting, recovers automatically after fault condition is removed 13.5 ~ 16V OVER VOLTAGE 18 ~ 20V 23 ~ 27V 28 ~ 34V 33 ~ 36V 42 ~ 48V 57 ~ 65V Protection type : Shut down and latch off o/p voltage, re-power on to recover 100 OVER TEMPERATURE WORKING TEMP. 89% <2mA / 240VAC LEAKAGE CURRENT PROTECTION 3.75 ~ 7.5A 2.0% SETUP, RISE TIME INPUT 4.75 ~ 9.5A VOLTAGE TOLERANCE Note.3 10 (RTH2) Protection type : Shut down o/p voltage, re-power on to recover Note.7 -30 ~ +55 WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT @ full load ; +70 @ 60% load 20 ~ 90% RH non-condensing -40 ~ +80 0.03%/ , 10 ~ 95% RH (0 ~ 50 ) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS UL60950-1, TUV EN60950-1, EN61347-1, EN61347-2-13 approved, IP65 approved (for A,B type only) WITHSTAND VOLTAGE I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:1.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH EMC EMI CONDUCTION & RADIATION Compliance to EN55015, EN55022 (CISPR22) Class B OTHERS HARMONIC CURRENT Compliance to EN61000-3-2 Class C (>50% load) ; EN61000-3-3 EMS IMMUNITY MTBF Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, light industry level (surge 4KV), criteria A 303.7Khrs min. MIL-HDBK-217F (25 ) 222*68*39mm (L*W*H) 1.0Kg; 12pcs/13Kg/0.49CUFT(CLG-150-A/B) 1Kg; 12pcs/13Kg/0.96CUFT(CLG-150-C) DIMENSION PACKING NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. Type A and type C only. 7. Please refer to derating curve. 8. Please refer to OLP characteristics. File Name:CLG-150-SPEC 2008-12-23 CLG-150 150W Single Output Switching Power Supply Mechanical Specification Case No. 954A series Unit:mm A Type:(CLG-150-_A) 222.2 198.2 12 9.4 9.6 Io ADJ. 300 20 34.2 300 20 +V(Red) -V(Black) 68 AC/L(Brown) AC/N(Blue) FG (Greed/Yellow) 18AWG 3C 14AWG 2C 9.4 Vo ADJ. 38.75 4.2 4PL IP65 rated. Output voltage and constant current level can be adjusted through internal potential meter. (Can access by removing the rubber stopper on the case.) B Type:(CLG-150-_B) 222.2 198.2 12 9.6 9.4 300 20 14AWG 2C 34.2 AC/L(Brown) AC/N(Blue) FG (Greed/Yellow) 68 300 20 18AWG 2C ADJ1(Blue) ADJ2(White) 4.2 4PL 38.75 9.4 18AWG 3C +V(Red) -V(Black) IP67 rated. Output constant current level can be adjusted through output cable by connecting a resistor between ADJ1 and ADJ2. Reference resistance value for output current adjustment (Typical) Resistance Percentage of rated current Open Slightly > 100% 4.7K 100% 620 75% 82 50% Short Slightly < 50% File Name:CLG-150-SPEC 2008-12-23 CLG-150 150W Single Output Switching Power Supply series C Type:(CLG-150-_C) 231.2 198.2 15.5 8.5 7 AC Input Terminal Pin No. Assignment 68 1 2 O/P Pin No. 1 2 3 Vo ADJ. 7 7.5 9.5 I/P 39 Io ADJ. 1 2 3 4.2 4PL Assignment FG AC/N AC/L DC Output Terminal Pin No. Assignment 38.75 Pin No. 1 2 Assignment +V -V Output voltage and constant current level can be adjusted through internal potential meter. (Can access by removing the rubber stopper on the case.) Block Diagram Fosc : 100KHz EMI FILTER & RECTIFIERS I/P RECTIFIERS & FILTER POWER SWITCHING PFC CIRCUIT +V -V ADJ1 ADJ2 (B Type) O.L.P. FG O.L.P. DETECTION CIRCUIT PWM & PFC CONTROL PFC CONTROL O.V.P. Derating Curve Static Characteristics fosc : 100KHz 100 230VAC 100 90 80 230VAC Input only 80 100VAC 70 LOAD (%) LOAD (%) 60 40 20 -25 -30 -10 0 15 30 50 55 60 AMBIENT TEMPERATURE ( ) -30 70 (HORIZONTAL) 60 50 40 90 100 125 135 145 155 165 175 180 200 230 280 INPUT VOLTAGE (V) 60Hz start up possible for 230VAC input File Name:CLG-150-SPEC 2008-12-23