Woodhead® Wide-Area Fluorescent Light For Class I, Division 2 and Zone 2 Applications FEATURES AND SPECIFICATIONS The most rugged, portable Wide-Area Fluorescent Light for Hazardous Locations on the market Workers in all professions face job hazards that, left unchecked, pose a serious threat to personal safety, security and productivity. These are issues that tie directly to every customer’s bottom line. For many Molex customers, ignitable concentrations of flammable gases, vapors or liquids pose a serious threat to job-site safety. The Woodhead Wide-Area Fluorescent Light for Hazardous Locations is designed to operate safely in hazardous environments while delivering high-output light in an extremely rugged and durable fixture. This light has been designed with direct customer input to ensure its use meets the needs of a wide range of applications. Already accepted in Canada and several markets in the US, the pending UL Listing will provide universal acceptance in all of North America, particularly for those customers not accepting compliance via a Canadian certification body. 130243Wide-Area Fluorescent Light (1075-HZ2) For additional product information, please visit: http://www.molex.com/link/widearea.html and http://www.woodhead.com. The light is certified by QPS (Quality Product Services) to Class I, Division 2 standards. QPS is a Canadian certification body nationally recognized in Canada and 6 US states. This fixture provides task lighting for maintenance and repair operations and wide-area light in potentially hazardous locations. The enclosure is constructed of sturdy, cast aluminum and is covered with a heavyduty, rubber-polycarbonate lens assembly that creates an impact-resistant seal keeping out moisture and contaminants. The twin 55W fluorescent lamps are shock-mounted in front of a specular aluminum reflector that produces light equivalent to many higher-wattage units while providing superior lamp life with respect to impact, vibration and overheating. Wide-Area Fluorescent Light For Class I, Division 2 and Zone 2 Applications Features and Benefits n Rugged cast-aluminum enclosure with unique rubber lens-gasket assembly provides superior strength & durability, impact and corrosion resistance, simple maintenance n Two, 55W CFL lamps (110 Watts), shock mounted, with integral aluminum reflector offers a rugged lamp design with lamp supports that will resist breakage while producing 9600 lumens n Energy-efficient, single ballast design ensures product uses less energy; field repairs and maintenance are simplified n Operating range -50°C to +40°C with a cold-start temperature of -20°C or colder allows design to be used in a wide range of temperatures n Third-party certified to CSA Class I, Division 2 environments and suitable for Zone 2 Groups B, C, and D T3A temperature rating; also outdoor rated; safe in wet locations with potentially ignitable gases of all groups and meets code n Customizable mounting clamp/handle/cord wrap and electrical cable fittings provide mounting flexibility; can use a wide range of connectors including BradPowerTM for Zone 2 SPECIFICATIONS Reference Information Packaging: Unit or Each QPS File No.: QFC3303-20 UL File No: Pending (available late 2009) Electrical Voltage (max.): 120VAC-277VAC/60 Hz Current (max.): 1.2A per fixture at 120VAC Total Wattage: 110 Watts Lamp Type: Compact Fluorescent PL-L 55 Watts Ballast Type: Rapid Start, 2 lamps Mechanical Enclosure Ratings: NEMA 3R Weight: 15.5 lbs. without cable Physical Housing: Cast Aluminum Cover: Silicone Rubber and Polycarbonate Operating Temperature: Low: -50°C Service: -10°C Ambient High: +40°C Low Temperature start: -20°C Woodhead® Wide-Area Fluorescent Light For Class I, Division 2 and Zone 2 Applications APPLICATIONS Wide-Area Fluorescent Light Petro-Chemical and Refinery Plants Shipyards Pulp and Paper n Scaffold and Ingress/Egress Lighting n Vessel and Tank Task Lighting n Scaffold and Area Lighting n Confined-Space Task and Area Lighting n Digester and Bleach Plant Maintenance Lighting n Chemical Recovery Maintenance Lighting Utility and Gas Water and Waste Water Treatment Aerospace n Scaffold and Area Lighting n Tunnels and Vault Areas n Covered Settling Tanks n Maintenance Task Lighting n Scaffold and Ingress/Egress Lighting n Fuselage Construction Task and Area Lighting ORDERING INFORMATION Order Number Engineering Part Number Description 1302430004 1075-HZ2N No Cable or cord grips 1302430002 1075-HZ2NK143F 3' #14-3 SOW, FLYING LEADS 1302430003 1075-HZ2NK123F 3' #12-3 SOW, FLYING LEADS 1302430001 1075-HZ25A143 25' #14-3 SOW, 5-15 WTT PLUG/CONN 1302430005 1075-HZ25B143 50' #14-3 SOW, 5-15 WTT PLUG/CONN 1302430007 1075-HZ2XA143F 25' #14-3 SOW, XP PLUG/CONN 1302430008 1075-HZ2XB143F 50' #14-3 SOW, XP PLUG/CONN 1302430009 1075-HZ2XK123F 3' #12-3 SOW, XP PLUG/CONN 1301900058 33-1075 Replacement Ballast 1301910093 34-1075 Replacement Lamp 55Watt Compact Fluorescent 1302011400 50-1075 Replacement Reflector 1301890009 40-1075 Replacement Lens-Gasket Assembly- Includes Fasteners www.molex.com/link/widearea.html Americas Headquarters Lisle, Illinois 60532 U.S.A. 1-800-78MOLEX [email protected] Order No. 987650-2772 Asia Pacific North Headquarters Yamato, Kanagawa, Japan 81-46-265-2325 [email protected] Asia Pacific South Headquarters Jurong, Singapore 65-6268-6868 [email protected] USA/KC/2009.02 European Headquarters Munich, Germany 49-89-413092-0 [email protected] Corporate Headquarters 2222 Wellington Ct. Lisle, IL 60532 U.S.A. P: 630-969-4550 F: 630-969-1352 © 2009, Molex