AC-DC 10-15 Watts xppower.com CU10-15 Series • Low Cost • Small Size • PCB Mount • 15 Watt Medical Version • Single Output 3.3-24 V • Peak Load Capability • Non-standard Outputs Available Specification Input General Input Voltage Input Frequency Input Current • 85-264 VAC (120-370 VDC) • 47-63 Hz • 0.13 A rms at 230 VAC (CU10) 0.20 A rms at 230 VAC (CU15) Inrush Current • 20 A at 115 VAC, 40 A at 230 VAC, cold start 25 ºC Earth Leakage Current • Class 2 (no earth) Input Protection • 1A fuse (CU10) 2A fuse (CU15, CU15-M) Output Output Voltage Output Voltage Trim Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Drift Line Regulation Load Regulation Transient Response • • • • • • • • • • • Ripple & Noise Overvoltage Protection Short Circuit Protection Temperature Coefficient • • • • See table ±5% ±1% No minimum load required 1.5 s max 14 ms max 16 ms typical at full load and 115 VAC 0.6% 0.5% max 1.0% max 10% load to full load 4% max deviation, recovery to within 1% within 500 µs for 25% load change 1% max pk-pk (see note 1) 130-150% of Vnom, recycle input to reset Trip and restart (Hiccup mode) 0.05%/˚C Efficiency Isolation Switching Frequency Power Density MTBF Environmental Operating Temperature • CU10/15: 0 ˚C to +65 ˚C, derate from full load at +45 ˚C to no load at +65 ˚C CU15-M: 0 ˚C to +70 ˚C, derate from full load at +50 ˚C to 50% load at +70 ˚C Cooling • Convection-cooled Operating Humidity • 95% RH, non-condensing Storage Temperature • -20 ˚C to +85 ˚C Operating Altitude • 3000 m Vibration • 10 Hz to 500 Hz, 2 g for 10 mins/cycle 60 min each cycle EMC & Safety Emissions ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Dips & interruptions Safety Approvals 1 • See tables • 3000 VAC Input to Output (CU10/15) 4000 VAC Input to Output (CU15-M) • 100 kHz typical for 10 W models 67 kHz typical for 15 W models • 2.43 W/in3 (CU10); 3.17 W/in3 (CU15) • >500 kHrs per MIL-HDBK-217F (15 & 24 V units >400 kHrs) • CU15-M: EN55011 Level B conducted Others: FCC20780 Level B, EN55022 Class B conducted • EN61000-4-2, level 3, Perf Criteria A • EN61000-4-3, level 3, Perf Criteria A • EN61000-4-4, level 2, Perf Criteria A • EN61000-4-5, level 3, Perf Criteria A • EN61000-4-6, 10 V, Perf Criteria A • EN61000-4-11, 30% 10 ms, 60% 1000 ms, 100% 5000 ms, Perf Criteria A, B, B • CU15-M: EN60601, UL2601-1, CSA22.2 No. 601.1 per cUL Others: EN60950, UL1950, CSA22.2 No. 234 per cUL Output Current Output Voltage(3) Output Power 8.25 W 3.3 5.0 9.0 12.0 15.0 24.0 10 W VDC VDC VDC VDC VDC VDC 3.3 5.0 9.0 12.0 15.0 24.0 15 W Nominal 3.00 A 3.00 A 1.67 A 1.25 A 1.00 A 0.63 A VDC VDC VDC VDC VDC VDC Model Number 65% 70% 72% 75% 75% 78% Output Current Output Voltage(3) Output Power 10 W Efficiency (typical) Peak(2) 3.80 A 2.80 A 1.50 A 1.20 A 1.00 A 0.65 A Nominal 2.50 A 2.00 A 1.12 A 0.84 A 0.67 A 0.42 A CU10-00 CU10-10 CU10-09 CU10-12 CU10-13 CU10-14 †^ †^ †^ Model Number(4) Efficiency (typical) Peak(2) 4.50 A 4.50 A 3.00 A 1.80 A 1.50 A 0.95 A †^ †^ 70% 73% 75% 80% 80% 82% CU15-00 CU15-10 CU15-09 CU15-12 CU15-13 CU15-14 †^ †^ †^ †^ †^ Notes 1. Measured at 20 MHz bandwidth. 3.3 V models are 50 mV maximum. 2. Peak load lasting <30 s with a maximum duty cycle of 10%. 3. Alternative output voltages available. Consult sales. 4. Medical approved 15 W version available. Add suffix ‘-M’ to part number. † Available from Farnell. ^Available from Newark. Mechanical Details CU15/CU15-M models 0.91 (23.0)** 0.91 (23.0)** 0.04 (1.02) 0.04 (1.02) 0.22 (5.5) 0.22 (5.5) **Note: CU15-M models height 0.99 (25.2) 0.07 (1.78) 0.04 (1.02) 0.04 (1.02) 2.126 (54.0) 2.126 (54.0) 2.56 (65.02) 2.56 (65.02) N N +Vo +Vo L L 0.157 (4.0) 0.157 (4.0) weight: 0.132 lb (60 g) weight: 0.132 lb (60 g) 0.4920.492 (12.50) (12.50) -Vo 1.3981.398 (35.51) (35.51) LL 0.15 (3.8) 0.1570.157 (4.0) (4.0) +Vo +Vo **Note: CU15-M models height 0.99 (25.2) -Vo 1.89 (48.0) 1.89 (48.0) N N 0.07 (1.78) 0.15 (3.8) 0.9450.945 (24.0)(24.0) 0.196(5.0) (5.0) 0.196 -Vo -Vo 0.885(22.5) (22.5) 0.885 1.77(45.0) (45.0) 1.77 0.15 (3.8) 0.15 (3.8) 0.491(12.47) (12.47) 0.491 0.07 (1.78) 0.07 (1.78) 1.28(32.48) (32.48) 1.28 0.91(23.0) (23.0) 0.91 CU10 models 2.441 (62.0) 2.75 (69.9) 2.441 (62.0) 2.75 (69.9) weight: 0.176 lb (80 g) weight: 0.176 lb (80 g) Notes 1. All dimensions shown in inches (mm). 2. For mating connectors only, order part number CU20-60 CONKIT †. 08-Oct-07 AC-DC CU10-15 Models and Ratings