ETC H12D4825D-10

Dual Relays
25-40Amp • 120/240, 480 Vac • AC Output
• Zero Voltage and Random
Turn-On Switching
• SCR Output
• Industry Standard Package
• Panel Mount
MODEL NUMBERS
Two totally independent AC output
relays come in a single standard panelmount package. Utilizing an AC switch
output with internal snubber, relays
provide greater protection against false
triggering. Model choices include zerovoltage or random turn-on (phase controllable) switching.
Manufactured in Crydom’s ISO 9002
Certified facility for optimum product
performance and reliability.
D2425D
D2440D
H12D4825D
H12D4840D
Operating Voltage (47-63 Hz) [Vrms]
24-280
24-280
48-530
48-530
Load Current Range ➂ [Arms]
.15-25
.15-40
.15-25
.15-40
Transient Overvoltage [Vpk]
600
600
1200
1200
Max. Surge Current, (16.6ms) [Apk]
250
625
250
625
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.6
1.6
1.6
1.6
Thermal Resistance Junction to Case (RθJC) [˚C/W] ➀
1.02
.63
1.02
.63
Maximum I2 t for Fusing, (8.3 msec.) [A2sec]
260
1620
260
1620
10
10
10
10
500
500
500
500
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
0.5
0.5
0.5
0.5
OUTPUT SPECIFICATIONS ➀
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]➁
Max. Turn-On Time
➃
Max. Turn-Off Time
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS ➀
DC CONTROL
Control Voltage Range
4-15Vdc
Max. Turn-On Voltage
4.0 Vdc
Min. Turn-Off Voltage
1.0 Vdc
330 Ohms
Nominal Input Impedance
12mA
Typical Input Current @ 5Vdc
©1998 CRYDOM CORP, Specifications subject to change without notice.
GENERAL NOTES
➀ All parameters at 25ºC and per section unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ Heat sinking required, for derating curves see page 2.
➃ Turn-on time for random turn-on (-10) versions is 0.1 msec.
FastFax Document No. 165
DUAL.032698, PAGE 1 OF 2
Crydom Heat Sinks offer excellent thermal
management and are perfectly matched to the
load current ratings of Crydom panel mount
relays. Request Crydom’s Heat Sink specification sheet for all the details.
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: [email protected]
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH,
Gewerbegebiet Im Schachen, D-66687 Nunkirchen, Germany • e-mail: [email protected]
Dual Relays
25-40Amp • 120/240, 480 Vac • AC Output
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz Input/Output/Base
4000 Vrms
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
Max. Capacitance Input/Output
10 pF
Ambient Operating Temperature Range
-40 to 80ºC
Ambient Storage Temperature Range
-40 to 125ºC
MECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (86.5g)
Encapsulation:
Thermally Conductive Epoxy
Terminals:
.25” Fastons, .025” Square Pins
120/240V MODEL
AVAILABLE OPTIONS
1.17
(29.7)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
-10 Random Turn-On,
Phase Controllable
(240V Only)
Example: D2440D-10
.15
(3.8)
1.00
(25.4)
A2
A1 A2
B2
A1
2.30
(58.4)
± 4-15VDC
1.87 1.60
(47.5) (40.6)
DUAL SOLID STATE RELAY
CONTROL
–
.50
(12.7)
A
1.80
(45.7)
CONTROL
+
–
B
+
.77
(19.6)
.85
(21.6)
1.31
(33.2)
.45
(11.4)
CURRENT DERATING CURVES
.187 X .032
FASTON
TERMINAL
(4 PLACES)
1.37
(34.8)
1.80
(45.7)
All dimensions are in inches (millimeters)
25A
120/24OV - 20A
CONTROL B
4-15VDC ±
PIN .025 SQ.
.100 CENTERS
4 PLACES
B1 B2
120/24OV - 20A
120/24OV - 20A
DUAL SOLID STATE RELAY
CONTROL A
MOUNTING HOLE/SLOT
.017 (4.3) DIA.
2 PLC'S
.250 X .032 FASTON
TERMINAL
(4 PLACES)
.55
(14.0)
B1
120/24OV - 20A
2.30 1.87
(58.4) (47.5)
480V MODEL
FASTON
TERMINAL
.250 X .032
(4 PLACES)
.85
(21.6)
1.31
(33.2)
40A
40
85
25A LIMIT
(1 SECTION)
2.0ºC/W
1.0ºC/W
95
5.0ºC/W
105
20
0
100
80A LIMIT
(2 SECTIONS)
80
60
0.5ºC/W
40A LIMIT
(1 SECTION)
40
90
95
1.0ºC/W
100
2.0ºC/W
20
105
5.0ºC/W
Max Allowable Base Temp. [ºC]
75
0.5ºC/W
Power Dissipation [W]
Power Dissipation [W]
50A LIMIT
(2 SECTIONS)
Max Allowable Base Temp. [ºC]
60
0
10
20
30
40
50
10
20
Load Current [Arms]
30
40
50
60
70
Max Ambient Temp. [ºC]
80
20
40
480Vrms
120/240Vrms
LOAD A
A2
B1
A1
B2
LOAD B
60
80 100 10
Load Current [Arms]
30
40
50
60
70
80
Max Ambient Temp. [ºC]
LOAD B
LOAD A
480Vrms
120/240Vrms
A1 A2
240V Model
B1 B2
480V Model
WIRING DIAGRAMS
-- B CONTROL
+ B CONTROL
-- A CONTROL
+ A CONTROL
20
-- A CONTROL
+ A CONTROL
+ B CONTROL
-- B CONTROL
©1998 CRYDOM CORP, Specifications subject to change without notice.
APPROVALS
UL E116949
CSA LR81689 (240V only)
VDE 5902 UG
FastFax Document No. 165
DUAL.032698, PAGE 2 OF 2
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: [email protected]
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH,
Gewerbegebiet Im Schachen, D-66687 Nunkirchen, Germany • e-mail: [email protected]