DRAN120 SERIES AC - DC DIN RAIL MOUNTABLE POWER SUPPLY INDUSTRIAL CONTROL EQUIPMENT FEATURES ‧P.F.C. FUNCTION AVAILABLE ‧PARALLEL FUNCTION AVAILABLE (SWITCH) ‧INPUT VOLTAGE 115/230VAC AUTO SELECT ‧SELV COMPONENTS DESIGN R R R HH H UL 1310 Class I, Div 2 EN 61558-1 EN 61558-2-17 UL 60950-1 IND. CONT. EQ. UL 508 a EN 60950-1 SELECTION CHART DRAN 120 - 24 x Wattage A : SCREW TERMINALS B : DETACHABLE CONNECTOR AL / BL : CLASS 2 POWER (24V ONLY) 12 : 12V OUT 24 : 24V OUT 48 : 48V OUT MODEL LIST MODEL NO. INPUT VOLTAGE DRAN120-12x 115 / 230 VAC 120 WATTS + 12 VDC 10A 82% 84% DRAN120-24x 115 / 230 VAC 120 WATTS + 24 VDC 5A 84% 86% DRAN120-24xL 115 / 230 VAC 91.2 WATTS + 24 VDC 3.8A 83% 85% DRAN120-48x 115 / 230 VAC 120 WATTS + 48 VDC 2.5A 85% 87% OUTPUT OUTPUT WATTAGE VOLTAGE Single Output Models SPECIFICATION OUTPUT CURRENT EFF. (min.) EFF. (typ.) o All Specifications Typical At Nominal Line, Full Load, 25 C Unless Otherwise Noticed GENERAL Conditions Conditions Characteristics Switching frequency Isolation voltage Isolation resistance Ambient temperature Derating (see derating curve) Storage temperature Relative humidity Input-FG 1500 / 2121 VAC / VDC Input-Output, @ 500VDC Operating at Vi nom 100 www.chinfa.com 2010.05.21 MΩ + 71 -35 o Vi nom, from +61 to +71 C Non operational 2.5 Vi nom, Io nom Vi nom, Io min Pollution degree unit unit KHz VAC / VDC 55 Bellcore Issue 6 @40 oC, GB 12V model Cooling max. max. 3000 / 4242 MTBF Dimension typ. typ. Vi nom, Io nom Input-Output Temperature coefficient Altitude during operation min. min. IEC 60068-2-13 Screw terminal type Detachable connector type -40 + 85 20 95 ± 0.03 o C % / oC o C % RH % / oC 440000 Hours 24V model AL / BL models 450000 Hours 486000 Hours 48V model 482000 4850 Hours m L124.5 x W64 x D123.6 mm L143.5 x W64 x D123.6 mm Free air convection 2 [email protected] P1 DRAN120 SERIES SPECIFICATION o All Specifications Typical At Nominal Line, Full Load, 25 C Unless Otherwise Noticed INPUT SPECIFICATIONS Characteristics Conditions Rated input voltage Io nom Absolute input max. range Ta min ... Ta max, Io nom unit VAC 115V selected 90 132 AC in 230V selected 180 264 VAC 210 375 VDC Rated input current AL, BL models Vi : 90 / 180 VAC, Io nom Line frequency AL, BL models Vi nom, Io nom 2.2 / 0.83 A A 2.8 / 1.4 47 Vi : 115 / 230 VAC , Io nom Vi : 230 VAC, Io nom VAC 1.65 / 0.65 A 2.0 / 0.8 A 63 24 / 48 Hz A 12V model 24 W 24V model AL / BL models 20 W 16 W 48V model 19 Input-Output Input-FG P.F.C. (Passive) max. AC in Input current Leakage current typ. 115 / 230 (auto select) DC in Vi : 115 / 230 VAC, Io nom Inrush current Power dissipation min. Vi : 230VAC, Io nom 0.25 W mA 3.5 mA max. unit +1 % 0.7 OUTPUT SPECIFICATIONS Characteristics Conditions min. Output voltage accuracy (Adjusted before shipment) Vi nom, Io max 0 Minimum load Line regulation Vi nom Io nom, Vi min ...Vi max Vi nom, Io min ...Io nom 0 Load regulation Voltage trim range Vi nom, 0.8 Io nom single mode Vi nom Vi nom, Io nom Vi nom, Io nom 22.5 28.5 VDC 22.5 24.5 VDC 45 2.5 A @ 48Vdc / 2.1 A @ 55 Vdc 12V model : with 7000μF CAP 24V, 48V models : with 3500μF CAP Vi nom, Io nom Ripple & noise Vi nom, Io nom, BW = 20MHz Power back immunity Vi nom, Io nom Vi nom, 1~0.5 Io nom ms 150 ms 500 ms 150 ms 2 ms 50 mV VDC 35 VDC 48V model 63 DC ON indicator threshold at start up (Green LED) Vi nom, Io nom 24V, 48V models 12V model DC LOW indicator threshold after start up (Red LED) Vi nom, Io nom 24V model 48V model 2010.05.21 1500 18 12V model www.chinfa.com ms 24V model Vi nom, Io nom Efficiency 1000 12V model Capacitor load Parallel operation ms 25 / 30 12V model : with 7000μF CAP Fall time Transient recovery time VDC 3.8 A @ 24Vdc / 3.7 A @ 24.5 Vdc Vi nom, Io nom Vi nom, Io nom 55 10 A @ 12Vdc / 8.2 A @ 14.5 Vdc % 5 A @ 24Vdc / 4.2 A @ 28.5 Vdc 24V, 48V models : with 3500μF CAP Rise time VDC 24V model AL / BL models 48V model Turn on time % 11.4 24V model AL / BL models Vi : 115 / 230 VAC , Io nom % 12V model parallel mode 12V model Hold up time % ± 0.5 ±1 ±5 14.5 48V model Rated continuous loading typ. 12V model 24V model 48V model 0.1 Io min ~ 0.9 Io max (Except AL / BL models) Vi nom, Io nom, Po / Pi VDC μF 7000 3500 μF 10 17.6 37 11.2 19.4 43 VDC VDC VDC 10 17.6 37 11.2 19.4 43 VDC VDC VDC 3 unit Up to 87%, See model list and typ efficiency curve [email protected] P2 DRAN120 SERIES SPECIFICATION All Specifications Typical At Nominal Line, Full Load, 25oC Unless Otherwise Noticed CONTROL AND PROTECTION Characteristics min. Conditions Input fuse typ. max. unit T3.15A / 250VAC internal Internal surge voltage protection IEC 61000-4-5 Vi nom (see typ current limited curve) Rated over load protection AL / BL models Threshold voltage of contact closed(at start up) Power Rdy (for 24V model only) Over voltage protection Varistor 110 145 % 102 108 % 17.6 19.4 VDC Electrical isolation Contact rating at 60VDC 500 Vi nom, Io nom (Auto Recovery) 125 AL / BL models VDC 102 0.3 A 140 % 106 % Output short circuit Fold forword Degree of protection IP20 APPROVALS AND STANDARDS UL / cUL UL 508 Listed UL 60950-1, UL 1310 Class 2 Power (24AL/BL models only) Recognized ISA 12.12.01(Class I, Division 2, Groups A, B, C and D) TUV EN 60950-1, CB scheme EN 61558-1, EN 61558-2-17 (meet EN 60204-1) CE EN 61000-6-3, EN 55022 Class B, EN 61000-3-2 Class D, EN 61000-3-3 EN 61000-6-2, EN 55024, EN 61000-4-2 Level 4, EN 61000-4-3 Level 3 EN 61000-4-4 Level 4, EN 61000-4-5 L-N Level 3, L / N-FG Level 4 EN 61000-4-6 Level 3, EN 61000-4-8 Level 4, EN 61000-4-11 ENV 50204 Level 2, EN 61204-3 CCC GB4943, GB9254, GB17625.1 Vibration resistance meet IEC 60068-2-6 (Mounting by rail : 10-500 Hz, 2G, along X, Y, Z each Axis, 60 min for each Axis ) Shock resistance meet IEC 60068-2-27 (15G, 11ms, 3 Axis, 6 Faces, 3 times for each Face) PHYSICAL CHARACTERISTICS Case size Screw terminal type 124.5 x 64 x 123.6 mm (4.9 x 2.52 x 4.87 inches) Detachable connector type 143.5 x 64 x 123.6 mm (5.65 x 2.52 x 4.87 inches) Metal Case material Weight 920g Packing 1.02kg ; 20 / 21.5kg / 2.01CUFT MECHANISM & PIN CONFIGURATION mm [inch] 64.00 [2.52] 64.00 [2.52] 6 6 firmly on the rail. 1 Vout ADJ. DC LO DC ON P INSTALLATION - - ++ Rdy DRAN120 L Vout ADJ. DC LO DC ON 124.50 [4.90] S - - ++ Rdy 143.50 [5.65] P Easy snap-on mounting onto the DIN-Rail 7.00 [0.30] (TS35/7.5 or TS35/15), unit sits safeIy and 1 124.50 [4.90] S 116.60 [4.59] CONSTRUCTION DRAN120 N L N AC INPUT 7 9 7 9 GENERAL TOLERANCE 0.00[0.00] - 30.00[1.18] ±0.30[0.01] 30.00[1.18] - 120.00[4.72] ±0.50[0.02] 120.00[4.72] - 400.00[15.75] ±0.80[0.03] www.chinfa.com 2010.05.21 Ventilation / Cooling Normal convection All sides 25mm free space For cooling recommended Connector size range Screw terminal: AWG24-10 (0.2~4mm2 ) flexible / solid cable, -Input connector can withstand torque at maximum 9 pound-inches. -Output connector can withstand torque at maximum 5.5 pound-inches. 8 m/m stripping at cable end recommends Detachable connector: AWG24-12 (0.2~2.5mm2 ) flexible / solid cable, -Input connector can withstand torque at maximum 4.5 pound-inches. -Output connector can withstand torque at maximum 7 pound-inches. 4~5 m/m stripping at cable end recommends Use copper conductors only, 60 / 75oC [email protected] P3 DRAN120 SERIES PIN ASSIGNMENT Designation PIN NO. OUT 1 2 3, 4 5, 6 IN 7 8 OTHER 9 Description RDY A normal open relay contact for DC ON level control (Never connect except 24V model) V+ V - Positive output terminal Negative output terminal L N DC ON Ground this terminal to minimize high-frequency emissions Input terminals (phase conductor, no polarity at DC input) Input terminals (neutral conductor, no polarity at DC input) Operation indicator LED DC LOW voltage indicator LED DC LO Vout ADJ. Trimmer-potentiometer for Vout adjustment Single / Parallel select switch (Except AL/BL models) S/P CIRCUIT SCHEMATIC ‧Block diagram for DRAN120 series L Fuse Filter N Inrush Current Limiter, Rectifier and Auto Select 115 / 230 Vac Vo + P. F. C. Circuit Smoothing Circuit Y Switching Rectifier Device PWM Controller Current Detection Vo Single / Parallel Select 2) Opto Isolation Reference & Error Amp. Opto Isolation Over Voltage Detection Vout ADJ. Output Level Detection DC ON (Green LED) DC LOW (Red LED) RDY 1) (Relay Contact) Note: 1) For 24V Model Only 2) AL/BL Models without this function TYP. CURRENT LIMITED CURVE Output Voltage [ % ] DRAN120-24x 100 75 230 Vac 115 Vac 50 25 0 100 110 120 130 140 150 160 Output Current [ % ] DERATING CURVE TYP. EFFICIENCY CURVE DRAN120-24x 85 EFFICIENCY [ % ] Power out [ % ] 100 75 0 -35 www.chinfa.com 2010.05.21 80 75 70 230 Vac 115 Vac 65 60 61 Temperature [ oC ] 71 10 25 50 Power out [ % ] 75 100 [email protected] P4