MAXIM DS1856B-050

Rev 1; 4/05
Dual, Temperature-Controlled Resistors with Internally Calibrated Monitors and Password Protection
The DS1856 dual, temperature-controlled, nonvolatile
(NV) variable resistors with three monitors consists of
two 256-position, linear, variable resistors; three analog
monitor inputs (MON1, MON2, MON3); and a direct-todigital temperature sensor. The device provides an
ideal method for setting and temperature-compensating
bias voltages and currents in control applications using
minimal circuitry. The variable resistor settings are
stored in EEPROM memory and can be accessed over
the 2-wire serial bus.
Relative to other members of the family, the DS1856 is
essentially a DS1859 with a DS1852-friendly memory
map. In particular, the DS1856 can be configured so
the 128 bytes of internal Auxiliary EEPROM memory is
mapped into Main Device Table 00h and Table 01h,
maintaining compatibility between both the
DS1858/DS1859 and the DS1852. The DS1856 also
features password protection equivalent to the DS1852,
further enhancing compatibility between the two.
Applications
Features
♦ SFF-8472 Compatible
♦ Five Monitored Channels (Temperature, VCC,
MON1, MON2, MON3)
♦ Three External Analog Inputs (MON1, MON2, MON3)
That Support Internal and External Calibration
♦ Scalable Dynamic Range for External Analog Inputs
♦ Internal Direct-to-Digital Temperature Sensor
♦ Alarm and Warning Flags for All Monitored
Channels
♦ Two Linear, 256-Position, Nonvolatile TemperatureControlled Variable Resistors
♦ Resistor Settings Changeable Every 2°C
♦ Three Levels of Security
♦ Access to Monitoring and ID Information
Configurable with Separate Device Addresses
♦ 2-Wire Serial Interface
♦ Two Buffers with TTL/CMOS-Compatible Inputs and
Open-Drain Outputs
♦ Operates from a 3.3V or 5V Supply
♦ -40°C to +95°C Operating Temperature Range
Optical Transceivers
Ordering Information
Optical Transponders
Instrumentation and Industrial Controls
RES0/RES1
RESISTANCE
(kΩ)
PART
RF Power Amps
Diagnostic Monitoring
Typical Operating Circuit
VCC
VCC = 3.3V
4.7kΩ
4.7kΩ
1
2-WIRE
INTERFACE
2
3
Tx-FAULT
4
0.1µF
VCC
SDA
H1
SCL
L1
OUT1
H0
IN1
5
LOS
OUT2
DS1856
L0
6
7
8
IN2
MON3
N.C.
MON2
GND
MON1
16
15
14
13
12
DS1856E-050
50/50
16 TSSOP
DS1856E-050/T&R
50/50
16 TSSOP
DS1856B-050
50/50
16-Ball CSBGA
Ordering Information continued at end of data sheet.
+Denotes lead free.
*Future product—contact factory for availability.
T&R denotes tape-and-reel.
All parts operate at the -40°C to +95°C temperature range.
DECOUPLING
CAPACITOR
TO LASER BIAS
CONTROL
TO LASER
MODULATION
CONTROL
Pin Configurations
TOP VIEW
A
B
IN1
OUT2
SCL
SDA
VCC
H0
H1
9 Tx BIAS*
16 VCC
SCL 2
15 H1
OUT1 3
14 L1
IN1 4
DIAGNOSTIC
INPUTS
C
D
*SATISFIES SFF-8472 COMPATIBILITY
SDA 1
L1
11 Rx POWER*
10 Tx POWER*
PIN-PACKAGE
N.C.
GND
1
IN2
L0
2
OUT1
MON1
3
MON3
MON2
DS1856
13 H0
12 L0
OUT2 5
IN2 6
11 MON3
N.C. 7
10 MON2
GND 8
9
MON1
4
CSBGA (4mm x 4mm)
1.0mm PITCH
TSSOP
______________________________________________ Maxim Integrated Products
For pricing delivery, and ordering information please contact Maxim/Dallas Direct! at
1-888-629-4642, or visit Maxim’s website at www.maxim-ic.com.
1
DS1856
General Description
DS1856
Dual, Temperature-Controlled Resistors with Internally Calibrated Monitors and Password Protection
ABSOLUTE MAXIMUM RATINGS
Voltage Range on VCC Relative to Ground ...........-0.5V to +6.0V
Voltage Range on Inputs Relative
to Ground* ..............................................-0.5V to (VCC + 0.5V)
Voltage Range on Resistor Inputs Relative
to Ground* ..............................................-0.5V to (VCC + 0.5V)
Current into Resistors............................................................5mA
Operating Temperature Range ...........................-40°C to +95°C
Programming Temperature Range .........................0°C to +70°C
Storage Temperature Range .............................-55°C to +125°C
Soldering Temperature .......................................See IPC/JEDEC
J-STD-020A
*Not to exceed 6.0V.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
(TA = -40°C to +95°C, unless otherwise noted.)
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
5.50
V
VCC + 0.3
V
-0.3
+0.3 x VCC
V
-0.3
VCC + 0.3
V
+3
mA
Supply Voltage
VCC
(Note 1)
2.85
Input Logic 1 (SDA, SCL)
VIH
(Note 2)
0.7 x Vcc
Input Logic 0 (SDA, SCL)
VIL
(Note 2)
Resistor Inputs (L0, L1, H0, H1)
Resistor Current
High-Impedance Resistor Current
IRES
-3
IROFF
0.001
Input logic 1
Input Logic Levels (IN1, IN2)
0.1
1.6
Input logic 0
0.9
µA
V
DC ELECTRICAL CHARACTERISTICS
(VCC = 2.85V to 5.5V, TA = -40°C to +95°C, unless otherwise noted.)
PARAMETER
Supply Current
Input Leakage
SYMBOL
ICC
CONDITIONS
MIN
(Note 3)
MAX
2
UNITS
mA
nA
-200
+200
VOL1
3mA sink current
0
0.4
VOL2
6mA sink current
0
0.6
Full-Scale Input (MON1, MON2,
MON3)
At factory setting
(Note 4)
2.4875
2.5
2.5125
V
Full-Scale VCC Monitor
At factory setting (Note 5)
6.5208
6.5536
6.5864
V
Low-Level Output Voltage
(SDA, OUT1, OUT2)
IIL
TYP
1
V
I/O Capacitance
CI/O
10
pF
Digital Power-On Reset
POD
1.0
2.2
V
Analog Power-On Reset
POA
2.0
2.6
V
2
_____________________________________________________________________
Dual, Temperature-Controlled Resistors with Internally Calibrated Monitors and Password Protection
DS1856
ANALOG RESISTOR CHARACTERISTICS
(VCC = 2.85V to 5.5V, TA = -40°C to +95°C, unless otherwise noted.)
MIN
TYP
MAX
Position 00h Resistance (50kΩ)
PARAMETER
TA = +25°C
CONDITIONS
0.65
1.0
1.35
UNITS
kΩ
Position FFh Resistance (50kΩ)
TA = +25°C
40
50
60
kΩ
Position 00h Resistance (30kΩ)
TA = +25°C
0.40
Position FFh Resistance (30kΩ)
TA = +25°C
30
Position 00h Resistance (20kΩ)
TA = +25°C
0.20
Position FFh Resistance (20kΩ)
TA = +25°C
15
Position 00h Resistance (10kΩ)
TA = +25°C
0.40
kΩ
Position FFh Resistance (10kΩ)
TA = +25°C
10
kΩ
Position 00h Resistance (2.5kΩ)
TA = +25°C
0.1
0.175
0.250
Position FFh Resistance (2.5kΩ)
TA = +25°C
2.0
2.50
3.0
kΩ
Absolute Linearity
(Note 6)
-2
+2
LSB
Relative Linearity
(Note 7)
-1
Temperature Coefficient
(Note 8)
kΩ
kΩ
0.40
0.55
kΩ
20
25
kΩ
+1
50
kΩ
LSB
ppm/°C
ANALOG VOLTAGE MONITORING
(VCC = 2.85V to 5.5V, TA = -40°C to +95°C, unless otherwise noted.)
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
∆VMON
610
µV
Supply Resolution
∆VCC
1.6
mV
Input/Supply Accuracy
(MON1, MON2, MON3, VCC)
ACC
Input Resolution
Update Rate for MON1, MON2,
MON3, Temp, or VCC
At factory setting
tframe
Input/Supply Offset
(MON1, MON2, MON3, VCC)
VOS
(Note 14)
0.25
0.5
% FS
(full scale)
47
60
ms
0
5
LSB
TYP
MAX
UNITS
±3.0
°C
DIGITAL THERMOMETER
(VCC = 2.85V to 5.5V, TA = -40°C to +95°C, unless otherwise noted.)
PARAMETER
Thermometer Error
SYMBOL
TERR
CONDITIONS
MIN
-40°C to +95°C
NONVOLATILE MEMORY CHARACTERISTICS
(VCC = 2.85V to 5.5V)
PARAMETER
EEPROM Writes
SYMBOL
CONDITIONS
+70°C (Note 14)
MIN
50,000
TYP
MAX
UNITS
Writes
_____________________________________________________________________
3
DS1856
Dual, Temperature-Controlled Resistors with Internally Calibrated Monitors and Password Protection
AC ELECTRICAL CHARACTERISTICS
(VCC = 2.85V to 5.5V, TA = -40°C to +95°C, unless otherwise noted. See Figure 6.)
PARAMETER
SYMBOL
SCL Clock Frequency (Note 9)
fSCL
Bus Free Time Between STOP and
START Condition (Note 9)
tBUF
Hold Time (Repeated)
START Condition (Notes 9, 10)
tHD:STA
LOW Period of SCL Clock (Note 9)
tLOW
HIGH Period of SCL Clock (Note 9)
tHIGH
Data Hold Time (Notes 9, 11, 12)
tHD:DAT
Data Setup Time (Note 9)
tSU:DAT
START Setup Time (Note 9)
tSU:STA
Rise Time of Both SDA and SCL
Signals (Note 13)
tR
Fall Time of Both SDA and SCL
Signals (Note 13)
tF
Setup Time for STOP Condition
tSU:STO
Capacitive Load for Each Bus Line
CB
EEPROM Write Time
tW
Note 1:
Note 2:
Note 3:
Note 4:
Note 5:
Note 6:
Note 7:
Note 8:
Note 9:
4
CONDITIONS
MIN
TYP
MAX
Fast mode
0
400
Standard mode
0
100
Fast mode
1.3
Standard mode
4.7
Fast mode
0.6
Standard mode
4.0
Fast mode
1.3
Standard mode
4.7
Fast mode
0.6
Standard mode
4.0
Fast mode
0
Standard mode
0
Fast mode
100
Standard mode
250
Fast mode
0.6
Standard mode
4.7
µs
µs
µs
0.9
µs
300
Standard mode
20 + 0.1CB
1000
Fast mode
20 + 0.1CB
300
Standard mode
20 + 0.1CB
300
0.6
4.0
µs
ns
20 + 0.1CB
Standard mode
kHz
µs
Fast mode
Fast mode
UNITS
ns
ns
µs
(Note 13)
10
400
pF
20
ms
All voltages are referenced to ground.
I/O pins of fast-mode devices must not obstruct the SDA and SCL lines if VCC is switched off.
SDA and SCL are connected to VCC and all other input signals are connected to well-defined logic levels.
Full scale is user programmable. The maximum voltage that the MON inputs read is approximately full scale, even if the voltage on the inputs is greater than full scale.
This voltage defines the maximum range of the analog-to-digital converter voltage, not the maximum V CC voltage.
Absolute linearity is the difference of measured value from expected value at DAC position. The expected value is a
straight line from measured minimum position to measured maximum position.
Relative linearity is the deviation of an LSB DAC setting change vs. the expected LSB change. The expected LSB change
is the slope of the straight line from measured minimum position to measured maximum position.
See the Typical Operating Characteristics.
A fast-mode device can be used in a standard-mode system, but the requirement tSU:DAT > 250ns must then be met. This
is automatically the case if the device does not stretch the LOW period of the SCL signal. If such a device does stretch the
LOW period of the SCL signal, it must output the next data bit to the SDA line tRMAX + tSU:DAT = 1000ns + 250ns = 1250ns
before the SCL line is released.
_____________________________________________________________________
Dual, Temperature-Controlled Resistors with Internally Calibrated Monitors and Password Protection
Typical Operating Characteristics
(VCC = 5.0V, TA = +25°C, for both 50kΩ and 20kΩ versions, unless otherwise noted.)
SUPPLY CURRENT vs. VOLTAGE
700
50kΩ VERSION
50
700
RESISTANCE (kΩ)
SUPPLY CURRENT (µA)
750
SDA = SCL = VCC
750
RESISTANCE vs. SETTING
60
DS1856 toc02
DS1856 toc01
SDA = SCL = VCC
650
600
550
30
20
500
650
10
450
600
400
-20
0
20
40
60
80
100
0
3.0
3.5
4.0
4.5
5.0
TEMPERATURE (°C)
VOLTAGE (V)
RESISTANCE vs. SETTING
ACTIVE SUPPLY CURRENT
vs. SCL FREQUENCY
15
10
5
0
50
100
150
200
250
SETTING (DEC)
800
RESISTOR 0 INL (LSB)
1.0
SDA = VCC
780
0.8
0.6
RESISTOR 0 INL (LSB)
20kΩ VERSION
5.5
DS1856 toc05
DS1856 toc04
20
ACTIVE SUPPLY CURRENT (µA)
-40
RESISTANCE (kΩ)
40
760
740
DS1856 toc06
SUPPLY CURRENT (µA)
800
DS1856 toc03
SUPPLY CURRENT vs. TEMPERATURE
800
0.4
0.2
0
-0.2
-0.4
-0.6
720
-0.8
0
-1.0
700
0
50
100
150
SETTING (DEC)
200
250
0
100
200
300
SCL FREQUENCY (kHz)
400
0
25 50 75 100 125 150 175 200 225 250
SETTING (DEC)
_____________________________________________________________________
5
DS1856
Note 10: After this period, the first clock pulse is generated.
Note 11: The maximum tHD:DAT only has to be met if the device does not stretch the LOW period (tLOW) of the SCL signal.
Note 12: A device must internally provide a hold time of at least 300ns for the SDA signal (see the VIH MIN of the SCL signal) to
bridge the undefined region of the falling edge of SCL.
Note 13: CB—total capacitance of one bus line, timing referenced to 0.9 x VCC and 0.1 x VCC.
Note 14: Guaranteed by design.
Typical Operating Characteristics (continued)
(VCC = 5.0V, TA = +25°C, for both 50kΩ and 20kΩ versions, unless otherwise noted.)
RESISTOR 0 DNL (LSB)
RESISTOR 1 INL (LSB)
0
-0.2
-0.4
0.8
0.6
0.4
0.2
0
-0.2
-0.4
0.4
0.2
0
-0.2
-0.4
-0.6
-0.6
-0.6
-0.8
-0.8
-0.8
-1.0
-1.0
25 50 75 100 125 150 175 200 225 250
25 50 75 100 125 150 175 200 225 250
0
SETTING (DEC)
SETTING (DEC)
RESISTANCE
vs. POWER-UP VOLTAGE
RESISTANCE
vs. POWER-UP VOLTAGE
POSITION 00h RESISTANCE
vs. TEMPERATURE
PROGRAMMED
RESISTANCE
(80h)
60
100
RESISTANCE (kΩ)
90
80
50
40
30
20
10
0
20kΩ VERSION
1.01
50kΩ VERSION
1.00
90
80
RESISTANCE (kΩ)
100
>1MΩ
110
DS1856 toc11
50kΩ VERSION
70
120
DS1856 toc10
>1MΩ
70
60
PROGRAMMED
RESISTANCE
(80h)
50
40
30
20
1
2
3
POWER-UP VOLTAGE (V)
4
5
0.99
0.98
0.97
10
0
0
25 50 75 100 125 150 175 200 225 250
SETTING (DEC)
120
110
-1.0
0
DS1856 toc12
0.2
DS1856 toc09
0.6
RESISTOR 1 DNL (LSB)
0.4
0
6
0.8
RESISTOR 1 INL (LSB)
RESISTOR 0 DNL (LSB)
0.6
1.0
DS1856 toc08
0.8
RESISTOR 1 DNL (LSB)
1.0
DS1856 toc07
1.0
RESISTANCE (kΩ)
DS1856
Dual, Temperature-Controlled Resistors with Internally Calibrated Monitors and Password Protection
0.96
0
1
2
3
4
5
POWER-UP VOLTAGE (V)
_____________________________________________________________________
-40 -25 -10
5
20
35
50
TEMPERATURE (°C)
65
80
95
Dual, Temperature-Controlled Resistors with Internally Calibrated Monitors and Password Protection
POSITION FFh RESISTANCE
vs. TEMPERATURE
20kΩ VERSION
0.37
50kΩ VERSION
49.75
20.00
DS1856 toc14
50.00
DS1856 toc13
0.38
POSITION FFh RESISTANCE
vs. TEMPERATURE
20kΩ VERSION
19.80
RESISTANCE (kΩ)
RESISTANCE (kΩ)
0.35
49.25
49.00
48.75
19.60
19.40
48.50
0.34
19.20
48.25
0.33
48.00
5
20
35
50
65
95
80
19.00
-40 -25 -10
TEMPERATURE (°C)
5
20
35
50
-40 -25 -10
50kΩ VERSION
350
300
250
+25°C TO +95°C
+25°C TO -40°C
200
150
100
50
0
-50
-100
100
150
200
5
20
35
50
65
80
95
TEMPERATURE (°C)
800
TEMPERATURE COEFFICIENT (ppm/°C)
DS1856 toc16
TEMPERATURE COEFFICIENT (ppm/°C)
95
TEMPERATURE COEFFICIENT vs. SETTING
TEMPERATURE COEFFICIENT vs. SETTING
50
80
TEMPERATURE (°C)
400
0
65
DS1856 toc17
-40 -25 -10
20kΩ VERSION
700
600
500
+25°C TO +95°C
+25°C TO -40°C
400
300
200
100
0
-100
250
0
SETTING (DEC)
50
100
150
250
200
SETTING (DEC)
LSB ERROR vs. FULL-SCALE INPUT
LSB ERROR vs. FULL-SCALE INPUT
+3 SIGMA
DS1856 toc19
3
DS1856 toc18
6
5
4
3
2
1
0
-1
-2
-3
-4
-5
-6
-7
-8
+3 SIGMA
2
1
LSB ERROR
LSB ERROR
RESISTANCE (kΩ)
49.50
0.36
DS1856 toc15
POSITION 00h RESISTANCE
vs. TEMPERATURE
MEAN
MEAN
0
-1
-2
-3 SIGMA
-3
-3 SIGMA
-4
0
25
50
75
NORMALIZED FULL SCALE (%)
100
0
3.125
6.250
9.375
12.500
NORMALIZED FULL SCALE (%)
_______________________________________________________________________________________
7
DS1856
Typical Operating Characteristics (continued)
(VCC = 5.0V, TA = +25°C, for both 50kΩ and 20kΩ versions, unless otherwise noted.)
DS1856
Dual, Temperature-Controlled Resistors with Internally Calibrated Monitors and Password Protection
Pin Description
PIN
BALL
NAME
FUNCTION
1
B2
SDA
2
A2
SCL
3
C3
OUT1
4
A1
IN1
5
B1
OUT2
6
C2
IN2
TTL/CMOS-Compatible Input to Buffer
7
C1
N.C.
No Connection
8
D1
GND
Ground
9
D3
MON1
External Analog Input
10
D4
MON2
External Analog Input
11
C4
MON3
External Analog Input
12
D2
L0
Low-End Resistor 0 Terminal. It is not required that the low-end terminals be connected to a potential
less than the high-end terminals of the corresponding resistor. Voltage applied to any of the resistor
terminals cannot exceed the power-supply voltage, VCC, or go below ground.
13
B3
H0
High-End Resistor 0 Terminal. It is not required that the high-end terminals be connected to a
potential greater than the low-end terminals of the corresponding resistor. Voltage applied to any of
the resistor terminals cannot exceed the power-supply voltage, VCC, or go below ground.
14
B4
L1
Low-End Resistor 1 Terminal
15
A4
H1
High-End Resistor 1 Terminal
16
A3
VCC
Supply Voltage
2-Wire Serial Data I/O Pin. Transfers serial data to and from the device.
2-Wire Serial Clock Input. Clocks data into and out of the device.
Open-Drain Buffer Output
TTL/CMOS-Compatible Input to Buffer
Open-Drain Buffer Output
Detailed Description
The user can read the registers that monitor the VCC,
MON1, MON2, MON3, and temperature analog signals.
After each signal conversion, a corresponding bit is set
that can be monitored to verify that a conversion has
occurred. The signals also have alarm and warning flags
that notify the user when the signals go above or below
the user-defined value. Interrupts can also be set for
each signal.
8
The position values of each resistor can be independently programmed. The user can assign a unique
value to each resistor for every 2°C increment over the
-40°C to +102°C range.
Two buffers are provided to convert logic-level inputs
into open-drain outputs. Typically, these buffers are
used to implement transmit (Tx) fault and loss-of-signal
(LOS) functionality. Additionally, OUT1 can be asserted
in the event that one or more of the monitored values
go beyond user-defined limits.
_____________________________________________________________________
Dual, Temperature-Controlled Resistors with Internally Calibrated Monitors and Password Protection
MD
MD
DS1856
AD
MD
AD (AUXILIARY DEVICE ENABLE A0h)
EEPROM
128 x 8 BIT
STANDARDS
TABLE
SELECT
DEVICE
ADDRESS
MD (MAIN DEVICE ENABLE)
DEVICE ADDRESS
IF ADEN = 0,
[00h - 7Fh OF AD]
IF ADEN = 1,
[80h-FFh OF MD,
TABLE 00/01h]
ADDRESS
R/W
ADEN ADFIX
SDA
TABLE
SELECT
TABLE
SELECT
EEPROM
72 x 8 BIT
80h-C7h
ADDRESS
ADDRESS
TABLE 04
RESISTOR 0
LOOK-UP
TABLE
R/W
EEPROM
72 x 8 BIT
80h-C7h
TABLE 05
RESISTOR 1
LOOK-UP
TABLE
R/W
ADDRESS
2-WIRE
INTERFACE
ADEN (BIT)
TEMP INDEX
DATA BUS
SCL
TEMP INDEX
R/W
TxF
Tx FAULT
MD
OUT1
MINT
R/W
EEPROM
96 x 8 BIT
00h-5Fh
LIMITS
TxF
SRAM
32 x 8 BIT
60h-7Fh
MONITORS LIMIT
LOW
H0
REGISTER
MONITORS LIMIT
HIGH
ADDRESS
RESISTOR 0
256 POSITIONS
L0
TEMP INDEX
INV1
RxL
OUT2
LOS
H1
REGISTER
IN1
MINT (BIT)
RESISTOR 1
256 POSITIONS
L1
TABLE SELECT
MEASUREMENT
INV2
RIGHT
SHIFTING
WARNING FLAGS
MD
R/W
ALARM FLAGS
INV1 (BIT)
IN2
TABLE SELECT
VCC
INTERNAL
CALIBRATION
INTERNAL
TEMP
ADDRESS
DEVICE ADDRESS
VENDOR
DS1856
MUX
MON1
ADC
12-BIT
INV2 (BIT)
TABLE 03
EEPROM
80h-B7h
ADEN (BIT)
ADFIX (BIT)
MON2
MON3
MONITORS LIMIT HIGH
A/D
CTRL
VCC
MUX
CTRL
MONITORS LIMIT LOW
MINT
MEASUREMENT
INTERRUPT
VCC
GND
MASKING (TMP, VCC, MON1, MON2, MON3)
COMP CTRL
WARNING FLAGS
COMPARATOR
ALARM FLAGS
Figure 1. Block Diagram
_____________________________________________________________________
9
DS1856
Dual, Temperature-Controlled Resistors with Internally Calibrated Monitors and Password Protection
Table 1. Scales for Monitor Channels at
Factory Setting
Table 3. Look-Up Table Address for
Corresponding Temperature Values
+FS
SIGNAL
+FS
(hex)
-FS
SIGNAL
-FS
(hex)
TEMPERATURE
(°C)
Temperature +127.984°
7FFC
-128°C
8000
SIGNAL
<-40
80h
VCC
6.5528V
FFF8
0V
0000
-40
80h
MON1
2.4997V
FFF8
0V
0000
-38
81h
MON2
2.4997V
FFF8
0V
0000
-36
82h
MON3
2.4997V
FFF8
0V
0000
-34
83h
—
—
Table 2. Signal Comparison
SIGNAL
FORMAT
VCC
Unsigned
MON1
Unsigned
MON2
Unsigned
MON3
Unsigned
Temperature
Two’s complement
+98
C5h
+100
C6h
+102
C7h
>+102
C7h
Monitor Conversion Example
Monitored Signals
Each signal (VCC, MON1, MON2, MON3, and temperature) is available as a 16-bit value with 12-bit accuracy
(left-justified) over the serial bus. See Table 1 for signal
scales and Table 2 for signal format. The four LSBs
should be masked when calculating the value. The 3
LSBs are internally masked with 0s.
The signals are updated every frame rate (tframe) in a
round-robin fashion.
The comparison of all five signals with the high and low
user-defined values are done automatically. The corresponding flags are set to 1 within a specified time of
the occurrence of an out-of-limit condition.
Calculating Signal Values
The LSB = 100µV for VCC, and the LSB = 38.147µV for
the MON signals when using factory default settings.
Monitor/VCC Bit Weights
MSB
215
214
213
212
211
210
29
28
LSB
27
26
25
24
23
22
21
20
VCC Conversion Examples
10
CORRESPONDING LOOK-UP
TABLE ADDRESS
MSB (BIN)
LSB (BIN)
VOLTAGE (V)
11000000
00000000
1.875
10000000
10000000
1.255
To calculate VCC, convert the unsigned 16-bit value to
decimal and multiply by 100µV.
To calculate MON1, MON2, or MON3, convert the
unsigned 16-bit value to decimal and multiply by
38.147µV.
To calculate the temperature, treat the two’s complement value binary number as an unsigned binary number, then convert to decimal and divide by 256. If the
result is greater than or equal to 128, subtract 256 from
the result.
Temperature: high byte: -128°C to +127°C signed; low
byte: 1/256°C.
Temperature Bit Weights
S
26
25
24
23
22
21
20
2-1
2-2
2-3
2-4
2-5
2-6
2-7
2-8
Temperature Conversion Examples
MSB (BIN)
LSB (BIN)
TEMPERATURE (°C)
01000000
00000000
+64
00001111
+64.059
MSB (BIN)
LSB (BIN)
VOLTAGE (V)
01000000
10000000
10000000
3.29
01011111
00000000
+95
11000000
11111000
4.94
11110110
00000000
-10
11011000
00000000
-40
____________________________________________________________________
Dual, Temperature-Controlled Resistors with Internally Calibrated Monitors and Password Protection
ADEN
(ADDRESS
ENABLE)
NO. OF SEPARATE
DEVICE
ADDRESSES
ADDITIONAL
INFORMATION
0
2
See Figure 2
1
1 (Main Device Only)
See Figure 3
DEC HEX 2-WIRE ADDRRESS A0h
0
0 00h
DEC HEX
0
0
AUXILIARY DEVICE
AUXILIARY DEVICE
ADEN
ADFIX
AUXILIARY
ADDRESS
MAIN ADDRESS
0
0
A0h
A2h
0
1
A0h
EEPROM
(Table 03, 8Ch)
1
0
—
A2h
1
1
—
EEPROM
(Table 03, 8Ch)
2-WIRE ADDRESS A2h (DEFAULT)
00h
MAIN DEVICE
MAIN DEVICE
EEPROM
AUXILIARY MEMORY
(128 BYTES)
Table 5. ADEN and ADFIX Bits
LOWER MEMORY
NOTE 1: ADEN BIT = 0. AUXILIARY MEMORY IS ADDRESSED USING THE AUXILIARY DEVICE
NOTE 1. 2-WIRE SLAVE ADDRESS OF A0h, AND THE REMAINDER OF THE MEMORY IS
NOTE 1. ADDRESSED USING THE MAIN DEVICE 2-WIRE SLAVE ADDRESS OF A2h
NOTE 1. (WHEN ADFIX = 0).
NOTE 2: TABLES 00h, 01h, AND 02h DO NOT EXIST.
PASSWORD ENTRY
(PWE) (4 BYTES)
127
7F
7Fh
127
7F
128
80
183
B7
199
200
C7
C8
TABLE SELECT BYTE 7Fh
80h
80h
80h
TABLE 03h
TABLE 04h
TABLE 05h
CONFIGURATION
TABLE
RESISTOR 0
LOOK-UP TABLE
(72 BYTES)
RESISTOR 1
LOOK-UP TABLE
(72 BYTES)
B7h
C7h
F0h
F0h
RESERVED AND
CALIBRATION
CONSTANTS
255
FF
C7h
RESERVED AND
CALIBRATION
CONSTANTS
FFh
FFh
Figure 2. Memory Organization, ADEN = 0
Variable Resistors
The value of each variable resistor is determined by
a temperature-addressed look-up table, which can
assign a unique value (00h to FFh) to each resistor for
every 2°C increment over the -40°C to +102°C range
(see Table 3). See the Temperature Conversion section
for more information.
The variable resistors can also be used in manual
mode. If the TEN bit equals 0, the resistors are in manual mode and the temperature indexing is disabled.
The user sets the resistors in manual mode by writing
to addresses 82h and 83h in Table 03 to control resistors 0 and 1, respectively.
Memory Description
The memory of the DS1856 is divided into two areas
referred to as the Main Device and the Auxiliary
Device. The Main Device comprises all of the DS1856
specific memory while the Auxiliary Device consists of
128 bytes of general-purpose EEPROM and is especially useful in GBIC applications. Main and Auxiliary
____________________________________________________________________
11
DS1856
Table 4. ADEN Address Configuration
DS1856
Dual, Temperature-Controlled Resistors with Internally Calibrated Monitors and Password Protection
DEC HEX 2-WIRE ADDRRESS A2h (DEFAULT)
0
0
00h
NOTE 1: ADEN BIT = 1. ALL MEMORY (INCLUDING THE AUXILIARY MEMORY) IS ADDRESSED USING THE
NOTE 1: MAIN DEVICE 2-WIRE SLAVE ADDRESS.
NOTE 2: TABLES 00h AND 01h ACCESS THE SAME PHYSICAL MEMORY.
NOTE 3: TABLE 02h DOES NOT EXIST.
LOWER MEMORY
PASSWORD ENTRY
(PWE) (4 BYTES)
127
7F
128
80 80h
TABLE SELECT BYTE 7Fh
80h
TABLE 00h/01h
183
B7
199
200
C7
C8
EEPROM
AUXILIARY MEMORY
(128 BYTES)
80h
80h
TABLE 03h
TABLE 04h
TABLE 05h
CONFIGURATION
TABLE
RESISTOR 0
LOOK-UP TABLE
(72 BYTES)
RESISTOR 1
LOOK-UP TABLE
(72 BYTES)
B7h
C7h
F0h
F0h
RESERVED AND
CALIBRATION
CONSTANTS
255
FF
FFh
C7h
RESERVED AND
CALIBRATION
CONSTANTS
FFh
FFh
Figure 3. Memory Organization, ADEN = 1
memories can be accessed by two separate 2-wire
slave addresses (see Table 4). The Main Device
address is A2h (or determined by the value in Table 03,
byte 8Ch, when ADFIX = 1) and the Auxiliary Device
address is A0h (fixed). A configuration bit, ADEN
(Table 03, byte 89h, bit 5), determines whether the
DS1856 uses one or two 2-wire slave addresses. This
feature can be used to save component count in SFF
applications or other applications where both GBIC
and monitoring functions are implemented and two
device addresses are needed.
The memory organization for ADEN = 0 is shown in
Figure 2. In this configuration, the 128 bytes of
Auxiliary Device EEPROM are located at memory locations 00h to 7Fh and accessed using the Auxiliary
Device 2-wire slave address of A0h (fixed). The
remainder of the DS1856’s memory is accessed using
the Main Device address.
The memory organization of the second configuration,
ADEN = 1, is shown in Figure 3. In this configuration, all
12
of the DS1856’s memory including the Auxiliary memory is accessed using only the Main Device address.
The Auxiliary Device memory is mapped into Table 00
and Table 01 in the Main Device. Both tables map to
the same block of physical memory. This is done to
improve the compatibility between previous members
of this IC family such as the DS1858/DS1859 and the
DS1852. In this configuration, the DS1856 ignores communication using the Auxiliary Device address.
The value of the Main Device address can be changed
to a value other than the default value of A2h (see data
sheet Table 5). There can be up to 128 devices sharing
a common 2-wire bus, with each device having its own
unique address. To change the Main Device address,
first write the desired value to the Chip Address byte
(Table 03, byte 8Ch). Then, enable the new address by
setting ADFIX to a 1. Subsequent 2-wire communication must be performed using the new Main Device
address. When ADFIX = 0, the Chip Address byte is
ignored, and the Main Device address is set to A2h.
____________________________________________________________________
Dual, Temperature-Controlled Resistors with Internally Calibrated Monitors and Password Protection
(PWE) bytes located in the Main Device at 7Bh to 7Eh.
The value entered is compared to both the PW1 and
PW2 settings located in Table 03, bytes B0h to B3h and
Table 03, bytes B4h to B7h, respectively, to determine
if access should be granted. Access is granted until
the password is changed or until power is cycled.
Writing PWE can be done with any level of access,
although PWE can never be read.
Table 6. Table Select Byte
The following table is the legend used in the memory
map to indicate the access level required for read and
write access.
Each table in the following memory map begins with a
higher level view of a particular portion of the memory
showing information such as row (8 bytes) and byte
names. The tables are then followed, where applicable,
by an Expanded Bytes table, which shows bit names
and values. Furthermore, both tables use the permission legend to indicate the access required on a row,
byte, and bit level.
TABLE SELECT
BYTE
00
TABLE NAME
01
Auxiliary Device Memory
(When ADEN = 1)
02
Does Not Exist
03
Configuration
04
Resistor 0 Look-up Table
05
Resistor 1 Look-up Table
Before attempting to read and write any of the bits or
bytes mentioned in this section, it is important to look at
the memory map provided in a subsequent section to
verify what level of password is required. Password
protection is described in the following section.
Writing PW1 and PW2 requires PW2 access. However,
PW1 and PW2 can never be read, even with PW2 access.
On power-up, PWE is set to all 1s (FFFFh). As long as
neither of the passwords are ever changed to FFFFh,
then User access is the power-up default. Likewise,
password protection can be intentionally disabled by
setting the PW2 password to FFFFh.
Memory Map
The memory map is followed by a Register Description
section, which describes bytes and bits in further detail.
Table 7. Password Permission
PERMISSION
Password Protection
The DS1856 uses two 4-byte passwords to achieve
three levels of access to various memory locations. The
three levels of access are:
User Access: This is the default state after power-up. It
allows read access to standard monitoring and status
functions.
Level 1 Access: This allows access to customer data
table (Tables 00 and 01) in addition to everything granted by User access. This level is granted by entering
Password 1 (PW1).
Level 2 Access: This allows access to all memory, settings, and features, in addition to everything granted by
Level 1 and User access. This level is granted by entering Password 2 (PW2).
To obtain a particular level of access, the corresponding password must be entered in the Password Entry
<0>
READ
WRITE
At least one byte in the row is different than
the rest of the row, so look at each byte
separately for permissions.
<1>
all
PW2
<2>
all
NA
<3>
all
all (The part also writes to
this byte.)
<4>
PW2
PW2 + mode_bit
<5>
all
all
<6>
NA
all
<7>
PW1
PW1
<8>
PW2
PW2
PW2
<9>
NA
<10>
PW2
NA
<11>
all
PW1
____________________________________________________________________
13
DS1856
The DS1856 2-wire interface uses 8-bit addressing,
which allows up to 256 bytes to be addressed traditionally on a given 2-wire slave address. However,
since the Main Device contains more than 256 bytes, a
table scheme is used. The lower 128 bytes of the Main
Device, memory locations 00h to 7Fh, function as
expected and are independent of the currently selected table. Byte 7Fh is the Table Select byte. This byte
determines which memory table will be accessed by
the 2-wire interface when address locations 80h to FFh
are accessed. Memory locations 80h to FFh are accessible only through the Main Device address. The
Auxiliary Device address has no access to the tables,
but the Auxiliary Device memory can be mapped into
the Main Device’s memory space (by setting ADEN =
1). Valid values for the Table Select byte are shown in
the table below.
DS1856
Dual, Temperature-Controlled Resistors with Internally Calibrated Monitors and Password Protection
Memory Map
LOWER MEMORY
Row
(hex)
Row
Name
Word 0
Byte 0/8
Word 1
Byte 1/9
Byte 2/A
Word 2
Byte 3/B
Byte 4/C
Word 3
Byte 5/D
Byte 6/E
Byte 7/F
00
<1>
Temp Alarm Hi
Temp Alarm Lo
Temp Warn Hi
08
<1>
VCC Alarm Hi
VCC Alarm Lo
VCC Warn Hi
VCC Warn Lo
10
<1>
Mon1 Alarm Hi
Mon1 Alarm Lo
Mon1 Warn Hi
Mon1 Warn Lo
18
<1>
Mon2 Alarm Hi
Mon2 Alarm Lo
Mon2 Warn Hi
Mon2 Warn Lo
20
<1>
Mon3 Alarm Hi
Mon3 Alarm Lo
Mon3 Warn Hi
Threshold0
Threshold1
Threshold2
Threshold3
Threshold4
Temp Warn Lo
Mon3 Warn Lo
28
<1>
EE
EE
EE
EE
EE
EE
EE
EE
30
<1>
EE
EE
EE
EE
EE
EE
EE
EE
38
<1>
EE
EE
EE
EE
EE
EE
EE
EE
40
<1>
EE
EE
EE
EE
EE
EE
EE
EE
48
<1>
EE
EE
EE
EE
EE
EE
EE
EE
50
<1>
EE
EE
EE
EE
EE
EE
EE
EE
58
<1>
EE
EE
EE
EE
EE
EE
EE
EE
user ROM
user ROM
user ROM
user ROM
user ROM
user ROM
user ROM
<2>
60
Values0
Temp Value
<0>
68
<2>
Values1
Alrm Wrn
<0>
78
Table Select
Alarm1
Reserved
Reserved
<6>
Reserved
Warn1
Status
Warn0
<6>
Reserved
<0>
Reserved
Reserved
<6>
Mon2 Value
<2>
Reserved
Alarm0
<6>
Mon1 Value
<2>
Mon3 Value
<2>
70
Vcc Value
Reserved
<6>
PWE msb
<3>
Update
Reserved
<5>
PWE lsb
Tbl Sel
EXPANDED BYTES
Byte
(hex)
Byte
Name
Bit7
bit15
User EE
bit13
EE
Bit5
bit12
bit11
EE
Bit4
bit10
bit9
EE
Bit3
bit8
bit7
EE
Bit2
bit6
bit5
EE
Bit1
bit4
bit3
EE
Bit0
bit2
bit1
EE
bit0
EE
S
26
25
24
23
22
21
20
2-1
2-2
2-3
2-4
2-5
2-6
2-7
2-8
Temp Warn
S
6
2
5
2
4
2
3
2
2
2
1
2
0
2
-1
2
-2
-3
-4
-5
-6
-7
2-8
Volt Alarm
215
214
213
212
211
210
29
28
27
26
25
24
23
22
21
20
Volt Warn
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
20
Temp Alarm
14
Bit6
bit14
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
28
User ROM
EE
EE
EE
EE
EE
EE
EE
EE
30
User ROM
EE
EE
EE
EE
EE
EE
EE
EE
38
User ROM
EE
EE
EE
EE
EE
EE
EE
EE
40
User ROM
EE
EE
EE
EE
EE
EE
EE
EE
48
User ROM
EE
EE
EE
EE
EE
EE
EE
EE
50
User ROM
EE
EE
EE
EE
EE
EE
EE
EE
58
User ROM
EE
EE
EE
EE
EE
EE
EE
EE
____________________________________________________________________
Dual, Temperature-Controlled Resistors with Internally Calibrated Monitors and Password Protection
60
Temp Value
S
26
25
24
23
22
21
20
2-1
2-2
2-3
2-4
2-5
2-6
2-7
2-8
62
VCC Value
215
214
213
212
211
210
29
28
27
26
25
24
23
22
21
20
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
20
1
20
1
20
64
66
68
Mon1 Value
Mon2 Value
Mon3 Value
2
2
15
14
2
2
15
14
2
2
<2>
2
12
2
2
13
2
10
2
2
SoftHiz
<2>
2
2
11
12
2
<11>
2
11
10
2
2
9
8
2
2
9
8
2
2
<2>
2
7
2
6
2
2
7
4
2
6
2
2
5
2
5
2
4
2
<2>
2
Temp Rdy
VCC Rdy
70
Alarm1
Temp Hi
Temp Lo
VCC Hi
VCC Lo
Mon1 Hi
71
Alarm0
Mon3 Hi
Mon3 Lo
Reserved
Reserved
Reserved
74
Warn1
Temp Hi
Temp Lo
VCC Hi
VCC Lo
Mon1 Hi
Mon1 Lo
Warn0
PWE msb
7D
PWE lsb
7F
Tbl Sel
Mon3 Hi
Reserved
Mon3 Rdy
2
3
2
2
2
3
2
2
2
2
2
2
<2>
Status
Mon2 Rdy
2
<2>
Update
Mon1 Rdy
Reserved
2
6F
75
Reserved
2
6E
7B
Rhiz
2
13
TxF
<2>
RxL
Reserved
Rdyb
Reserved
Reserved
Mon1 Lo
Mon2 Hi
Mon2 Lo
Reserved
Reserved
Mint
Mon2 Hi
Mon2 Lo
Mon3 Lo
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
231
230
229
228
227
226
225
223
221
219
217
15
14
13
12
11
10
2
2
2
27
2
26
2
2
224
9
8
2
25
2
24
222
7
6
2
220
5
2
4
2
23
2
22
218
3
2
2
2
216
1
20
2
21
20
AUXILIARY (VALID WHEN ADEN = 0)
Row
(hex)
00–7F
Row
Name
<1>
EE
Word 0
Word 1
Word 2
Word 3
Byte 0/8
Byte 1/9
Byte 2/A
Byte 3/B
Byte 4/C
Byte 5/D
Byte 6/E
Byte 7/F
EE
EE
EE
EE
EE
EE
EE
EE
TABLE 00/01 (VALID WHEN ADEN = 1)
Row
(hex)
80–FF
Row
Name
<7>
EE
Word 0
Word 1
Word 2
Word 3
Byte 0/8
Byte 1/9
Byte 2/A
Byte 3/B
Byte 4/C
Byte 5/D
Byte 6/E
Byte 7/F
EE
EE
EE
EE
EE
EE
EE
EE
____________________________________________________________________
15
DS1856
Memory Map (continued)
DS1856
Dual, Temperature-Controlled Resistors with Internally Calibrated Monitors and Password Protection
Memory Map (continued)
TABLE 03 (CONFIGURATION)
Row
(hex)
Row
Name
80
<0>
88
<8>
Config0
Config1
Word 0
Byte 0/8
<8>
Word 1
Byte 1/9
Byte 2/A
<4>
Mode
<4>
Tindex
Int Enable
Config
Word 2
Byte 3/B
<4>
Res0
<8>
Res1
Reserved
Byte 4/C
Reserved
Reserved
chip addr
Word 3
Byte 5/D
<8>
Reserved
Byte 6/E
<8>
Reserved
Reserved
Byte 7/F
<8>
Reserved
Rshift1
Rshift0
<8>
Reserved
Vcc Scale
Mon1 Scale
Mon2 Scale
98
<8>
Mon3 Scale
Reserved
Reserved
Reserved
A0
<8>
Reserved
Vcc Offset
MON1 Offset
MON2 Offset
A8
<8>
Offset1
MON3 Offset
Reserved
Reserved
Internal Temp Offset*
Pwd Value
PW1 msb
PW1 lsb
PW2 msb
PW2 lsb
90
B0
Scale0
Scale1
Offset0
<9>
EXPANDED BYTES
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
Byte
(hex)
Byte
Name
80
Mode
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
TEN
AEN
81
Tindex
27
26
25
24
23
22
21
20
7
6
5
4
3
2
1
20
1
82
bit15
Res0
bit14
bit13
2
bit12
bit11
2
7
bit9
2
6
Reserved
Reserved
Reserved
Reserved
Inv 1
Inv 2
23
22
21
20
Mon10
Reserved
Mon22
Mon21
Mon20
0
Vcc
Mon1
Mon2
Reserved
Reserved
ADEN
ADFIX
8C
Chip Addr
27
26
25
24
8E
Rshift1
Reserved
Mon12
Mon11
Reserved
2
1
96
98
Mon2 Scale
Mon3 Scale
2
2
bit0
Mon3
Temp
Config
Mon1 Scale
bit1
Reserved
Int Enable
94
2
bit2
20
2
2
Reserved
Reserved
Reserved
Reserved
215
214
213
212
211
210
29
28
27
26
25
24
23
22
21
20
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
20
1
20
1
20
3
2
15
2
15
2
2
14
2
14
2
2
13
2
13
2
2
12
2
12
2
11
2
11
2
10
2
10
2
9
2
9
2
8
2
8
2
7
2
7
2
6
2
6
2
5
2
5
2
4
2
4
2
3
2
3
2
2
2
2
2
2
2
2
2
2
2
2
2
22
A4
Mon1 Offset
S
S
215
214
213
212
211
210
29
28
27
26
25
24
23
22
S
15
14
13
12
11
10
9
8
7
6
5
4
3
22
3
22
-5
2-6
17
216
1
20
17
A8
AE
B0
B2
Mon3 Offset
Temp Offset*
PW1 msb
PW1 lsb
B4
PW2 msb
B6
PW2 lsb
S
S
S
8
31
2
15
2
31
2
30
2
14
2
30
2
7
2
29
2
13
2
29
2
6
2
28
2
12
2
28
2
5
2
27
2
11
2
27
2
4
2
26
2
10
2
26
2
11
2
3
2
25
2
9
2
25
2
10
2
2
2
24
2
8
2
24
2
9
2
1
2
23
2
7
2
23
2
8
2
0
2
22
2
6
2
22
7
2
-1
2
21
2
5
2
6
2
-2
2
20
2
4
2
20
2
5
2
-3
2
19
2
3
2
19
2
4
2
-4
2
18
2
2
2
18
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
216
215
214
213
212
211
210
29
28
27
26
25
24
23
22
21
20
____________________________________________________________________
21
2
2
*The final result must be XOR’ed with BB40h.
16
2
4
2
2
12
5
2
2
2
6
2
2
13
7
2
2
2
8
2
2
14
9
2
2
2
10
2
2
15
11
2
S
2
12
2
S
S
13
2
VCC Offset
Mon2 Offset
14
2
Mon3
A2
A6
15
Mon3
bit3
2
2
Mon3
bit4
2
89
Rshift0
bit5
3
88
VCC Scale
bit6
2
4
Res1
92
bit7
2
5
2
bit8
83
8F
2
bit10
Dual, Temperature-Controlled Resistors with Internally Calibrated Monitors and Password Protection
TABLE 04 (LOOKUP TABLE FOR RESISTOR 0)
Row
(hex)
Row
Name
Word 0
Word 1
Word 2
Word 3
Byte 0/8
Byte 1/9
Byte 2/A
Byte 3/B
Byte 4/C
Byte 5/D
Byte 6/E
Byte 7/F
C8
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
D0
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
D8
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
E0
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
E8
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
80
<8>
88
<8>
90
<8>
98
<8>
A0
<8>
A8
<8>
B0
<8>
B8
<8>
C0
<8>
LUT
LUT
LUT
LUT
LUT
LUT
LUT
LUT
LUT
F0
F8
<10>
Res0 data
Resistor 0 Calibration Constants (see data sheet Table 8)
EXPANDED BYTES
Byte
(hex)
Byte
Name
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
80–C7
Res0
27
26
25
24
23
22
21
20
F8–FF
Res0 data
Resistor 0 Calibration Constants (see data sheet Table 8 for weighting)
____________________________________________________________________
17
DS1856
Memory Map (continued)
DS1856
Dual, Temperature-Controlled Resistors with Internally Calibrated Monitors and Password Protection
Memory Map (continued)
TABLE 05 (LOOKUP TABLE FOR RESISTOR 1)
Row
(hex)
Row
Name
Word 0
Word 1
Word 2
Word 3
Byte 0/8
Byte 1/9
Byte 2/A
Byte 3/B
Byte 4/C
Byte 5/D
Byte 6/E
Byte 7/F
C8
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
D0
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
D8
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
E0
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
80
<8>
88
<8>
90
<8>
98
<8>
A0
<8>
A8
<8>
B0
<8>
B8
<8>
C0
<8>
LUT
LUT
LUT
LUT
LUT
LUT
LUT
LUT
LUT
E8
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
F0
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
<10>
F8
Res1 data
Resistor 1 Calibration Constants (see data sheet Table 8)
EXPANDED BYTES
Byte
(hex)
Byte
Name
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
80–C7
Res1
27
26
25
24
23
22
21
20
F8–FF
Res1 data
18
Resistor 1 Calibration Constants (see data sheet Table 8 for weighting)
____________________________________________________________________
Dual, Temperature-Controlled Resistors with Internally Calibrated Monitors and Password Protection
Name of Row
•
•
Name of Byte............. <Read/Write><Volatile><Power-On-Value>
Name of Byte............. <Read/Write><Nonvolitile><Factory-Default-Setting>
Threshold0
•
•
•
•
Temp High Alarm ..... <R-all/W-pw2><NV><7FFFh> Temperature measurements above this
two's complement threshold set its corresponding alarm bit.
Measurements below this threshold clear the alarm bit.
Temp Low Alarm....... <R-all/W-pw2><NV><8000h> Temperature measurements below this
two's complement threshold set its corresponding alarm bit.
Measurements above this threshold clear the alarm bit.
Temp High Warning . <R-all/W-pw2><NV><7FFFh> Temperature measurements above this
two's complement threshold set its corresponding warning bit.
Measurements below this threshold clear the warning bit.
Temp Low Warning .. <R-all/W-pw2><NV><8000h> Temperature measurements below this
two's complement threshold set its corresponding warning bit.
Measurements above this threshold clear the warning bit.
Threshold1
•
•
•
•
VCC High Alarm........ <R-all/W-pw2><NV><FFFFh> Voltage measurements of the VCC
input above this unsigned threshold set its corresponding alarm bit.
Measurements below this threshold clear the alarm bit.
VCC Low Alarm.......... <R-all/W-pw2><<NV><0000h> Voltage measurements of the VCC
input below this unsigned threshold set its corresponding alarm bit.
Measurements above this threshold clear the alarm bit.
VCC High Warning.... <R-all/W-pw2><NV><FFFFh> Voltage measurements of the VCC
input above this unsigned threshold set its corresponding warning
bit. Measurements below this threshold clear the warning bit.
VCC Low Warning..... <R-all/W-pw2><<NV><0000h> Voltage measurements of the VCC
input below this unsigned threshold set its corresponding warning
bit. Measurements above this threshold clear the warning bit.
Threshold2
•
•
•
•
Mon1 High Alarm ..... <R-all/W-pw2><NV><FFFFh> Voltage measurements of the Mon1
input above this unsigned threshold set its corresponding alarm bit.
Measurements below this threshold clear the alarm bit.
Mon1 Low Alarm ...... <R-all/W-pw2><NV><0000h> Voltage measurements of the Mon1
input below this unsigned threshold set its corresponding alarm bit.
Measurements above this threshold clear the alarm bit.
Mon1 High Warning. <R-all/W-pw2><NV><FFFFh> Voltage measurements of the Mon1
input above this unsigned threshold set its corresponding warning
bit. Measurements below this threshold clear the warning bit.
Mon1 Low Warning .. <R-all/W-pw2><NV><0000h> Voltage measurements of the Mon1
input below this unsigned threshold set its corresponding warning
bit. Measurements above this threshold clear the warning bit.
____________________________________________________________________
19
DS1856
Register Descriptions
DS1856
Dual, Temperature-Controlled Resistors with Internally Calibrated Monitors and Password Protection
Register Descriptions (continued)
Threshold3
•
•
•
•
Mon2 High Alarm ..... <R-all/W-pw2><NV><FFFFh> Voltage measurements of the Mon2
input above this unsigned threshold set its corresponding alarm bit.
Measurements below this threshold clear the alarm bit.
Mon2 Low Alarm ...... <R-all/W-pw2><NV><0000h> Voltage measurements of the Mon2
input below this unsigned threshold set its corresponding alarm bit.
Measurements above this threshold clear the alarm bit.
Mon2 High Warning. <R-all/W-pw2><NV><FFFFh> Voltage measurements of the Mon2
input above this unsigned threshold set its corresponding warning
bit. Measurements below this threshold clear the warning bit.
Mon2 Low Warning .. <R-all/W-pw2><NV><0000h> Voltage measurements of the Mon2
input below this unsigned threshold set its corresponding warning
bit. Measurements above this threshold clear the warning bit.
Threshold4
•
•
•
•
Mon3 High Alarm ..... <R-all/W-pw2><NV><FFFFh> Voltage measurements of the Mon3
input above this unsigned threshold set its corresponding alarm bit.
Measurements below this threshold clear the alarm bit.
Mon3 Low Alarm ...... <R-all/W-pw2><NV><0000h> Voltage measurements of the Mon3
input below this unsigned threshold set its corresponding alarm bit.
Measurements above this threshold clear the alarm bit.
Mon3 High Warning. <R-all/W-pw2><NV><FFFFh> Voltage measurements of the Mon3
input above this unsigned threshold set its corresponding warning
bit. Measurements below this threshold clear the warning bit.
Mon3 Low Warning .. <R-all/W-pw2><NV><0000h> Voltage measurements of the Mon3
input below this unsigned threshold set its corresponding warning
bit. Measurements above this threshold clear the warning bit.
User ROM
•
User ROM ................. <R-all/W-pw2><NV><00h> Nonvolatile EEPROM memory.
A2D Value0
•
•
•
•
20
Temp Meas ................ <R-all><W-NA><0000h> The signed two's complement Direct-toTemperature measurement.
VCC Meas................... <R-all><W-NA><0000h> Unsigned voltage measurement.
Mon1 Meas................ <R-all><W-NA><0000h> Unsigned voltage measurement.
Mon2 Meas................ <R-all><W-NA><0000h> Unsigned voltage measurement.
____________________________________________________________________
Dual, Temperature-Controlled Resistors with Internally Calibrated Monitors and Password Protection
A2D Value1
•
•
•
Mon3 Meas................
Reserved ....................
Status .........................
a) Rhiz....................
b) Soft Hiz..............
c) Reserved ............
d) TxF ...................
e) RxL ...................
f) Rdyb...................
•
Update .......................
a)
b)
c)
d)
Temp Rdy ..........
VCC Rdy.............
Mon1 Rdy..........
Mon2 Rdy..........
e) Mon3 Rdy..........
Status
•
•
•
•
Alarm0 .......................
a) Temp Hi.............
b) Temp Lo ............
c) VCC Hi ..............
d) VCC Lo ..............
e) MON1 Hi...........
f) MON1 Lo ..........
g) MON2 Hi...........
h) MON2 Lo ..........
Alarm1 .......................
a) MON3 HI...........
b) MON3 Lo ..........
c) Mint ...................
Reserved ....................
Warning0 ...................
a) Temp Hi.............
b) Temp Lo ............
c) VCC Hi .............
<R-all><W-NA><0000h> Unsigned voltage measurement.
<R-all><W-NA><0000h>
<R-all><W-see bits><conditional>
<R-all><W-NA><1b> High when resistor outputs are high impedance.
<R-all><W-all><0b> Setting this bit will make resistor outputs high
impedance.
<R-all><W-NA><0b>
<R-all><W-NA><conditional> Reflects the logic level to be output on pin Out1.
<R-all><W-NA><conditional> Reflects the logic level to be output on pin Out2.
<R-all><W-NA>< VCC dependant > Ready Bar. When the supply is
above the Power-On-Analog (POA) trip point, this bit is active LOW.
Thus, this bit reads a logic One if the supply is below POA or too low
to communicate over the 2-wire bus.
<R-all/W-all><00h> Status of completed conversions. At Power-On,
these bits are cleared and will be set as each conversion is completed.
These bits can be cleared so that a completion of a new conversion
may be verified.
Temperature conversion is ready.
VCC conversion is ready.
Mon1 conversion is ready.
Mon2 conversion is ready.
Mon3 conversion is ready.
<R-all><W-NA><10h> High Alarm Status bits.
High Alarm Status for Temperature measurement.
Low Alarm Status for Temperature measurement.
High Alarm Status for VCC measurement.
Low Alarm Status for VCC measurement. This bit is set when theVCC
supply is below the POA trip point value. It clears itself when a VCC
measurement is completed and the value is above the low threshold.
High Alarm Status for MON1 measurement.
Low Alarm Status for MON1 measurement.
High Alarm Status for MON2 measurement.
Low Alarm Status for MON2 measurement.
<R-all><W-NA><00h> Low Alarm Status bits.
High Alarm Status for MON3 measurement.
Low Alarm Status for MON3 measurement.
Maskable Interrupt. If an alarm is present and the alarm is enabled then
this bit is high. Otherwise this bit is a zero.
<R-all><W-NA><00h>.
<R-all><W-NA><00h> High Warning Status bits.
High Warning Status for Temperature measurement.
Low Warning Status for Temperature measurement.
High Warning Status for VCC measurement.
____________________________________________________________________
21
DS1856
Register Descriptions (continued)
DS1856
Dual, Temperature-Controlled Resistors with Internally Calibrated Monitors and Password Protection
Register Descriptions (continued)
d) VCC Lo .............. Low Warning Status for VCC measurement. This bit is set when the VCC
supply is below the POA trip point value. It clears itself when a VCC
measurement is completed and the value is above the low threshold.
e) MON1 Hi........... High Warning Status for MON1 measurement.
f) MON1 Lo .......... Low Warning Status for MON1 measurement.
g) MON2 Hi........... High Warning Status for MON2 measurement.
h) MON2 Lo .......... Low Warning Status for MON2 measurement.
•
Warning1 ................... <R-all><W-NA><00h> Low warning Status bits.
a) MON3 HI........... High Warning Status for MON3 measurement.
b) MON3 Lo........... Low Warning Status for MON3 measurement.
Table Select
•
•
•
Config0
•
•
22
Reserved .................... <R-NA><W-all><00h>
PWE........................... <R-NA><W-all><FFFFFFFFh> Password Entry. There are two
passwords for the DS1856. The lower level password (PW1) has
all the access of a normal user plus those made available with PW1.
The higher level password (PW2) has all of the access of PW1
plus those made available with PW2. The value of the password reside
in EE inside of PW2 memory.
TBL Sel...................... <R-all/W-all><00h> Table Select. The upper memory tables of the
DS1856 are accessible by writing the correct table value in this register.
If the device is configured to have a Table 01h then writing a 00h ora
01h in this byte will access that table.
Mode.......................... <R-pw2/W-pw2><NV><03h>
a) TEN.................... At Power-On this bit is HIGH, which enables autocontrol of the LUT.
If this bit is written to a ZERO then the resistor values are writeable by
the user and the LUT recalls are disabled. This allows the user to
interactively test their modules by manually writing resistor values. The
resistors will update with the new value at the end of the write cycle.
Thus both registers (Res0 and Res1) should be written in the same
write cycle. The 2-wire Stop condition is the end of the write cycle.
b) AEN ................... At Power-On this bit is HIGH, which enables autocontrol of the LUT.
If this bit is cleared to a ZERO then the temperature calculated index
value ( T index ) is writeable by the user and the updates of calculated
indexes are disabled. This allows the user to interactively test their
modules by controlling the indexing for the look-up tables. The recalled
values from the LUTs will appear in the resistor registers after the next
completion of a temperature conversion (just like it would happen in
auto mode). Both pots will update at the same time (just like it would
happen in auto mode).
.
T Index....................... <R-pw2><W-pw2+AENb><00h> Holds the calculated index based on
the Temperature Measurement. This index is used for the address
during Look-up of Tables 4 and 5.
____________________________________________________________________
Dual, Temperature-Controlled Resistors with Internally Calibrated Monitors and Password Protection
•
•
•
Config
.
Res0 ........................... <R-pw2><W-pw2+TENb><FFh> The base value used for Resistor 0
and recalled from Table 4 at the memory address found in T Index.
This register is updated at the end of the Temperature conversion.
Res1 ........................... <R-pw2><W-pw2+TENb><FFh> The base value used for Resistor 1
and recalled from Table 5 at the memory address found in T Index.
This register is updated at the end of the Temperature conversion.
Reserved .................... <R-pw2><W-pw2><00h> SRAM.
1
•
•
•
•
•
Int Enable.................. <R-pw2/W-pw2><NV><F8h> Configures the maskable interrupt for
the Out1 pin.
a) Temp Enable...... Temperature measurements, outside of the threshold limits, are enabled
to create an active interrupt on the Out1 pin.
b) VCC Enable......... VCC measurements, outside of the threshold limits, are enabled to create
an active interrupt on the Out1 pin.
c) MON1 Enable.... MON1 measurements, outside of the threshold limits, are enabled to
create an active interrupt on the Out1 pin.
d) MON2 Enable.... MON2 measurements, outside of the threshold limits, are enabled to
create an active interrupt on the Out1 pin.
e) MON3 Enable.... MON3 measurements, outside of the threshold limits, are enabled to
create an active interrupt on the Out1 pin.
f) Reserved ............ EE.
Config........................ <R-pw2/W-pw2><NV><00h> Configure the memory location and the
polarity of the digital outputs.
a) Reserved ............ EE.
b) ADEN ................ Auxiliary Device ENable. 128 bytes of EE are addressable depending
on the value of this bit. When set to a 1, the memory is located in or as
Table 01h. When set to a 0, the memory is addressed by using a Device
address of A0h and the locations in memory are 00h to 7Fh.
c) ADFIX ............... Device Fixable Address. When this bit is set to a 1, the main memory
of the DS1856 is a Device Address equal to the value found in byte
chip_address. When this bit is set to a 0 the main memory of the DS1856
is a Device Address of A2h.
d) Inv1 .................... Enable the inversion of the relationship between IN1 and OUT1.
e) Inv2 .................... Enable the inversion of the relationship between IN2 and OUT2.
Chip Address............. This value becomes the Device address for the main memory when
ADFIX bit is set.
Right Shift1 ................ Allows for right-shifting the final answer of some voltage
measurements. This allows for scaling the measurements to the smallest
full-scale voltage and then right-shifting the final result so the reading is
weighted to the correct lsb.
Right Shift0 ................ Allows for right-shifting the final answer of some voltage
measurements. This allows for scaling the measurements to the smallest
full-scale voltage and then right-shifting the final result so the reading is
weighted to the correct lsb.
____________________________________________________________________
23
DS1856
Register Descriptions (continued)
DS1856
Dual, Temperature-Controlled Resistors with Internally Calibrated Monitors and Password Protection
Register Descriptions (continued)
Scale0
•
•
•
Scale1
VCC Scale................... <R-pw2/W-pw2><NV><6.5535V> Controls the Scaling or Gain of the
VCC measurements.
MON1 Scale .............. <R-pw2/W-pw2><NV><2.500V> Controls the Scaling or Gain of the
MON1 measurements.
MON2 Scale .............. <R-pw2/W-pw2><2.500V> Controls the Scaling or Gain of the
MON2 measurements.
•
MON3 Scale .............. <R-pw2/W-pw2><NV><2.500V> Controls the Scaling or Gain of the
MON3 measurements.
•
VCC Offset.................. <R-pw2/W-pw2><NV><0000h> Allows for offset control of VCC
measurement if desired.
MON1 Offset ............. <R-pw2/W-pw2><NV><0000h> Allows for offset control of MON1
measurement if desired.
MON2 Offset ............. <R-pw2/W-pw2><NV><0000h> Allows for offset control of MON2
measurement if desired.
Offset0
•
•
Offset1
•
•
MON3 Offset ............. <R-pw2/W-pw2><NV><0000h> Allows for offset control of MON3
measurement if desired.
Temp Offset ............... <R-pw2/W-pw2><NV><0000h> Allows for offset control of Temp
measurement if desired.
PWD Value
•
•
LUT
24
•
•
Password 1................ <R-NA/W-pw2><NV><FFFFFFFFh> The PWE value is compared
against the value written to this location to enable PW1 access. At
power-on, the PWE value is set to all ones. Thus writing these bytes to
all ones grants PW1 access on power-up without writing the password entry.
Password 2................ <R-NA/W-pw2><NV><FFFFFFFFh> The PWE value is compared
against the value written to this location to enable PW2 access. At
power-on, the PWE value is set to all ones. Thus writing these bytes to
all ones grants PW2 access on power-up without writing the password entry.
Res0 ........................... The unsigned value for Resistor 0.
Res1 ........................... The unsigned value for Resistor 1.
____________________________________________________________________
Dual, Temperature-Controlled Resistors with Internally Calibrated Monitors and Password Protection
2
R − u x 1 + v x (C − 25) + w x (C − 25) 

−
pos(α, R, C) =
2

(x) x 1 + y x (C − 25) + z x (C − 25) 
R = the resistance desired at the output terminal
C = temperature in degrees Celsius
u, v, w, x1, x0, y, z, and α are calculated values found in
the corresponding look-up tables. The variable x from the
equation above is separated into x1 (the MSB of x) and x0
(the LSB of x). Their addresses and LSB values are given
below. The variable y is assigned a value. All other variables are unsigned. Resistor 0 variables are found in
Table 04, and Resistor 1 variables are found in Table 05.
When shipped from the factory, all other memory locations in the LUTs are programmed to FFh.
Table 8. Calibration Constants
ADDRESS
VARIABLE
LSB
F8h
u
20
F9h
v
20E-6
FAh
w
100E-9
FBh
x1
21
FCh
x0
2-7
FDh
y
FEh
z
10E-9
FFh
α
2-2
2E-6 (signed)
8E-6 (signed) for 2.5k resistor
Internal Calibration
The DS1856 has two methods for scaling an analog
input to a digital result. The two methods are gain and
offset. Each of the inputs (V CC, MON1, MON2, and
MON3) has a unique register for the gain and the offset
found in Table 03h, 92h to 99h, and A2h to A9h.
To scale the gain and offset of the converter for a specific input, you must first know the relationship between
the analog input and the expected digital result. The
input that would produce a digital result of all zeros is
the null value (normally this input is GND). The input
that would produce a digital result of all ones is the fullscale (FS) value. The FS value is also found by multiplying an all-ones digital answer by the weighted LSB
(e.g., since the digital reading is a 16-bit register, let us
assume that the LSB of the lowest weighted bit is
50µV, then the FS value is 65,535 x 50µV = 3.27675V).
A binary search is used to scale the gain of the converter. This requires forcing two known voltages to the
input pin. It is preferred that one of the forced voltages
is the null input and the other is 90% of FS. Since the
LSB of the least significant bit in the digital reading register is known, the expected digital results are also
known for both inputs (null/LSB = CNT1 and 90%FS/
LSB = CNT2).
The user might not directly force a voltage on the input.
Instead they have a circuit that transforms light, frequency, power, or current to a voltage that is the input
to the DS1856. In this situation, the user does not need
to know the relationship of voltage to expected digital
result but instead knows the relationship of light, frequency, power, or current to the expected digital result.
An explanation of the binary search used to scale the
gain is best served with the following example pseudocode:
/* Assume that the null input is 0.5V. */
/* In addition, the requirement for LSB is 50µV. */
FS = 65535 x 50E-6;
/* 3.27675 */
CNT1 = 0.5 / 50E-6;
CNT2 = 0.90 x FS / 50E-6;
/* 10000 */
/* 58981.5 */
/* Thus the null input 0.5V and the 90% of FS input is
2.949075V. */
Set the trim-offset-register to zero;
Set Right-Shift register to zero (typically zero.
See the Right-Shifting section);
gain_result = 0h;
Clamp = FFF8h/2^(Right_Shift_Register);
For n = 15 down to 0
begin
____________________________________________________________________
25
DS1856
Programming the Look-up Table (LUT)
The following equation can be used to determine which
resistor position setting, 00h to FFh, should be written in
the LUT to achieve a given resistance at a specific temperature.
Dual, Temperature-Controlled Resistors with Internally Calibrated Monitors and Password Protection
DS1856
gain_result = gain_result + 2^n;
Force the 90% FS input (2.949075V);
Meas2 = read the digital result from
the part;
If Meas2 >= Clamp then
gain_result = gain_result – 2^n;
Else
Force the null input (0.5V);
Meas1 = read the digital result from
the part;
if (Meas2 – Meas1) > (CNT2 –
CNT1) then
gain_result = gain_result – 2^n;
end;
Set the gain register to gain_result;
The gain register is now set and the resolution of the
conversion will best match the expected LSB. The next
step is to calibrate the offset of the DS1856. With the
correct gain value written to the gain register, again
force the null input to the pin. Read the digital result
from the part (Meas1). The offset value is equal to the
negative value of Meas1.
value can be right-shifted four times without losing resolution. Table 9 shows when the right-shifting method can
be used.
Temperature Conversion
The direct-to-digital temperature sensor measures temperature through the use of an on-chip temperature
measurement technique with a -40°C to +102°C operating range. Temperature conversions are initiated upon
power-up, and the most recent conversion is stored in
memory locations 60h and 61h of the Main Device,
which are updated every tframe. Temperature conversions do not occur during an active read or write to
memory.
The value of each resistor is determined by the temperature-addressed look-up table. The look-up table assigns
a unique value to each resistor for every 2°C increment
with a 1°C hysteresis at a temperature transition over the
operating temperature range (see Figure 4).
Table 9. Right Shifting
OUTPUT RANGE USED
WITH ZERO RIGHT-SHIFTS
NUMBER OF
RIGHT-SHIFTS NEEDED
0h....FFFFh
0
0h....7FFFh
1
0h....3FFFh
2
0h....1FFFh
3
0h....0FFFh
4
 Meas1 
Offset _Re gister = 

 4 
The calculated offset is now written to the DS1856 and
the gain and offset scaling is now complete.
M6
Right-Shifting A/D Conversion Result
(Scalable Dynamic Ranging)
If the maximum desired digital output is less than 7FFFh,
then the calibrated system is using less than 1/2 of the
ADC’s range. Similarly, if the maximum desired digital
output is less than 1FFFh, then the calibrated system is
only using 1/8 of the ADC’s range. For example, if using
a zero for the right-shift during internal calibration and
the maximum expected input results in a maximum digital output less than 1FFCh, only 1/8 of the ADC’s range is
used. If left like this, the three MS bits of the ADC will
never be used. In this example, a value of 3 for the rightshifting maximizes the ADC range. No resolution is lost
since this is a 12-bit converter that is left justified. The
26
M5
MEMORY LOCATION
The right-shifting method is used to regain some of the
lost ADC range of a calibrated system. If a system is calibrated so the maximum expected input results in a digital output value of less than 7FFFh (1/2 FS), then it is a
candidate for using the right-shifting method.
DECREASING
TEMPERATURE
M4
M3
INCREASING
TEMPERATURE
M2
M1
2
4
6
8
TEMPERATURE (°C)
Figure 4. Look-Up Table Hysteresis
____________________________________________________________________
10
12
Dual, Temperature-Controlled Resistors with Internally Calibrated Monitors and Password Protection
Furthermore, as the device powers up, the VCClo alarm
flag (bit 4 of 70h in Main Device) defaults to a 1 until the
first VCC analog-to-digital conversion occurs and sets or
clears the flag accordingly.
2-Wire Operation
Clock and Data Transitions: The SDA pin is normally
pulled high with an external resistor or device. Data on
the SDA pin may only change during SCL-low time
periods. Data changes during SCL-high periods will
indicate a START or STOP condition depending on the
conditions discussed below. See the timing diagrams
in Figures 5 and 6 for further details.
START Condition: A high-to-low transition of SDA with
SCL high is a START condition that must precede any
other command. See the timing diagrams in Figures 5
and 6 for further details.
STOP Condition: A low-to-high transition of SDA with
SCL high is a STOP condition. After a read or write
sequence, the stop command places the DS1856 into a
low-power mode. See the timing diagrams in Figures 5
and 6 for further details.
Acknowledge: All address and data bytes are transmitted through a serial protocol. The DS1856 pulls the
SDA line low during the ninth clock pulse to acknowledge that it has received each word.
Standby Mode: The DS1856 features a low-power
mode that is automatically enabled after power-on,
after a STOP command, and after the completion of all
internal operations.
Device Addressing: The DS1856 must receive an 8-bit
device address, the slave address byte, following a
START condition to enable a specific device for a read
or write operation. The address is clocked into this part
MSB to LSB. The address byte consists of either A2h or
the value in Table 03, 8Ch for the Main Device or A0h
for the Auxiliary Device, then the R/W bit. This byte
must match the address programmed into Table 03,
8Ch or A0h (for the Auxiliary Device). If a device
address match occurs, this part will output a zero for
one clock cycle as an acknowledge and the corresponding block of memory is enabled (see the Memory
Organization section). If the R/W bit is high, a read
operation is initiated. If the R/W is low, a write operation
is initiated (see the Memory Organization section). If the
address does not match, this part returns to a lowpower mode.
Write Operations
After receiving a matching address byte with the R/W
bit set low, if there is no write protect, the device goes
into the write mode of operation (see the Memory
Organization section). The master must transmit an 8bit EEPROM memory address to the device to define
the address where the data is to be written. After the
byte has been received, the DS1856 transmits a zero
for one clock cycle to acknowledge the address has
been received. The master must then transmit an 8-bit
data word to be written into this address. The DS1856
again transmits a zero for one clock cycle to acknowledge the receipt of the data. At this point, the master
must terminate the write operation with a STOP condition. The DS1856 then enters an internally timed write
process tw to the EEPROM memory. All inputs are disabled during this byte write cycle.
Page Write
The DS1856 is capable of an 8-byte page write. A page
is any 8-byte block of memory starting with an address
evenly divisible by eight and ending with the starting
address plus seven. For example, addresses 00h
through 07h constitute one page. Other pages would
be addresses 08h through 0Fh, 10h through 17h, 18h
through 1Fh, etc.
____________________________________________________________________
27
DS1856
Power-Up and Low-Voltage Operation
During power-up, the device is inactive until V CC
exceeds the digital power-on-reset voltage (POD). At this
voltage, the digital circuitry, which includes the 2-wire
interface, becomes functional. However, EEPROMbacked registers/settings cannot be internally read
(recalled into shadow SRAM) until VCC exceeds the analog power-on-reset voltage (POA), at which time the
remainder of the device becomes fully functional. Once
VCC exceeds POA, the RDYB bit in byte 6Eh of the Main
Device memory is timed to go from a 1 to a 0 and indicates when analog-to-digital conversions begin. If VCC
ever dips below POA, the RDYB bit reads as a 1 again.
Once a device exceeds POA and the EEPROM is
recalled, the values remain active (recalled) until VCC falls
below POD.
For 2-wire device addresses sourced from EEPROM
(ADFIX = 1), the device address defaults to A2h until VCC
exceeds POA and the EEPROM values are recalled. The
Auxiliary Device (A0h) is always available within this voltage window (between POD and the EEPROM recall)
regardless of the programmed state of ADEN.
DS1856
Dual, Temperature-Controlled Resistors with Internally Calibrated Monitors and Password Protection
A page write is initiated the same way as a byte write,
but the master does not send a STOP condition after the
first byte. Instead, after the slave acknowledges the
data byte has been received, the master can send up to
seven more bytes using the same nine-clock sequence.
The master must terminate the write cycle with a STOP
condition or the data clocked into the DS1856 will not be
latched into permanent memory.
The address counter rolls on a page during a write. The
counter does not count through the entire address
space as during a read. For example, if the starting
address is 06h and 4 bytes are written, the first byte
goes into address 06h. The second goes into address
07h. The third goes into address 00h (not 08h). The
fourth goes into address 01h. If 9 bytes or more are
written before a STOP condition is sent, the first bytes
sent are overwritten. Only the last 8 bytes of data are
written to the page.
Acknowledge Polling: Once the internally timed write
has started and the DS1856 inputs are disabled,
acknowledge polling can be initiated. The process
involves transmitting a START condition followed by the
device address. The R/W bit signifies the type of operation that is desired. The read or write sequence will only
be allowed to proceed if the internal write cycle has
completed and the DS1856 responds with a zero.
Read Operations
After receiving a matching address byte with the R/W bit
set high, the device goes into the read mode of operation. There are three read operations: current address
read, random read, and sequential address read.
Current Address Read
The DS1856 has an internal address register that maintains the address used during the last read or write
operation, incremented by one. This data is maintained
as long as VCC is valid. If the most recent address was
the last byte in memory, then the register resets to the
first address.
Once the device address is clocked in and acknowledged by the DS1856 with the R/W bit set to high, the
current address data word is clocked out. The master
does not respond with a zero, but does generate a
STOP condition afterwards.
Single Read
A random read requires a dummy byte write sequence to
load in the data byte address. Once the device and data
address bytes are clocked in by the master and acknowledged by the DS1856, the master must generate another
START condition. The master now initiates a current
28
address read by sending the device address with the
R/W bit set high. The DS1856 acknowledges the device
address and serially clocks out the data byte.
Sequential Address Read
Sequential reads are initiated by either a current
address read or a random address read. After the master receives the first data byte, the master responds
with an acknowledge. As long as the DS1856 receives
this acknowledge after a byte is read, the master can
clock out additional data words from the DS1856. After
reaching address FFh, it resets to address 00h.
The sequential read operation is terminated when the
master initiates a STOP condition. The master does not
respond with a zero.
The following section provides a detailed description of
the 2-wire theory of operation.
2-Wire Serial-Port Operation
The 2-wire serial-port interface supports a bidirectional
data transmission protocol with device addressing. A
device that sends data on the bus is defined as a transmitter, and a device that receives data as a receiver.
The device that controls the message is called a master. The devices that are controlled by the master are
slaves. The bus must be controlled by a master device
that generates the serial clock (SCL), controls the bus
access, and generates the START and STOP conditions. The DS1856 operates as a slave on the 2-wire
bus. Connections to the bus are made through the
open-drain I/O lines SDA and SCL. The following I/O
terminals control the 2-wire serial port: SDA, SCL.
Timing diagrams for the 2-wire serial port can be found
in Figures 5 and 6. Timing information for the 2-wire
serial port is provided in the AC Electrical
Characteristics table for 2-wire serial communications.
The following bus protocol has been defined:
• Data transfer may be initiated only when the bus is
not busy.
• During data transfer, the data line must remain stable whenever the clock line is high. Changes in the
data line while the clock line is high will be interpreted as control signals.
Accordingly, the following bus conditions have been
defined:
Bus not busy: Both data and clock lines remain high.
Start data transfer: A change in the state of the data
line from high to low while the clock is high defines a
START condition.
____________________________________________________________________
Dual, Temperature-Controlled Resistors with Internally Calibrated Monitors and Password Protection
SDA
MSB
SLAVE ADDRESS
R/W
DIRECTION
BIT
ACKNOWLEDGEMENT
SIGNAL FROM RECEIVER
ACKNOWLEDGEMENT
SIGNAL FROM RECEIVER
SCL
1
2
6
7
8
9
1
2
3–7
8
ACK
START
CONDITION
9
ACK
STOP
CONDITION
OR REPEATED
START
CONDITION
REPEATED IF MORE BYTES
ARE TRANSFERRED
Figure 5. 2-Wire Data Transfer Protocol
SDA
tBUF
tHD:STA
tLOW
tR
tSP
tF
SCL
tHD:STA
STOP
tSU:STA
tHIGH
tSU:DAT
START
REPEATED
START
tSU:STO
tHD:DAT
Figure 6. 2-Wire AC Characteristics
____________________________________________________________________
29
DS1856
plished on the 2-wire bus. Depending on the state of the
R/W bit, two types of data transfer are possible.
Each data transfer is initiated with a START condition
and terminated with a STOP condition. The number of
data bytes transferred between START and STOP conditions is not limited and is determined by the master
device. The information is transferred byte-wise and
each receiver acknowledges with a ninth bit.
Stop data transfer: A change in the state of the data
line from low to high while the clock line is high defines
the STOP condition.
Data valid: The state of the data line represents valid
data when, after a START condition, the data line is stable for the duration of the high period of the clock signal.
The data on the line can be changed during the low period of the clock signal. There is one clock pulse per bit of
data. Figures 5 and 6 detail how data transfer is accom-
DS1856
Dual, Temperature-Controlled Resistors with Internally Calibrated Monitors and Password Protection
Within the bus specifications, a standard mode
(100kHz clock rate) and a fast mode (400kHz clock
rate) are defined. The DS1856 works in both modes.
Acknowledge: Each receiving device, when addressed,
is obliged to generate an acknowledge after the byte has
been received. The master device must generate an
extra clock pulse, which is associated with this acknowledge bit.
A device that acknowledges must pull down the SDA line
during the acknowledge clock pulse in such a way that
the SDA line is a stable low during the high period of the
acknowledge-related clock pulse. Setup and hold times
must be taken into account. A master must signal an end
of data to the slave by not generating an acknowledge bit
on the last byte that has been clocked out of the slave. In
this case, the slave must leave the data line high to
enable the master to generate the STOP condition.
1) Data transfer from a master transmitter to a
slave receiver. The first byte transmitted by the
master is the command/control byte. Next follows
a number of data bytes. The slave returns an
acknowledge bit after each received byte.
2) Data transfer from a slave transmitter to a master receiver. The master transmits the first byte
(the command/control byte) to the slave. The slave
then returns an acknowledge bit. Next follows a
number of data bytes transmitted by the slave to
the master. The master returns an acknowledge bit
after all received bytes other than the last byte. At
the end of the last received byte, a not acknowledge can be returned.
30
The master device generates all serial clock pulses and
the START and STOP conditions. A transfer is ended with
a STOP condition or with a repeated START condition.
Since a repeated START condition is also the beginning
of the next serial transfer, the bus is not released.
The DS1856 can operate in the following two modes:
1) Slave Receiver Mode: Serial data and clock are
received through SDA and SCL, respectively. After
each byte is received, an acknowledge bit is transmitted. START and STOP conditions are recognized as the beginning and end of a serial transfer.
Address recognition is performed by hardware
after the slave (device) address and direction bit
have been received.
2) Slave Transmitter Mode: The first byte is
received and handled as in the slave receiver
mode. However, in this mode the direction bit
indicates that the transfer direction is reversed.
Serial data is transmitted on SDA by the DS1856,
while the serial clock is input on SCL. START and
STOP conditions are recognized as the beginning
and end of a serial transfer.
____________________________________________________________________
Dual, Temperature-Controlled Resistors with Internally Calibrated Monitors and Password Protection
PART
RES0/RES1
RESISTANCE
(kΩ)
PIN-PACKAGE
PART
RES0/RES1
RESISTANCE
(kΩ)
PIN-PACKAGE
DS1856B-050/T&R
50/50
16-Ball CSBGA
DS1856E-030+T&R*
30/10
16 TSSOP
DS1856E-050+
50/50
16 TSSOP
DS1856B-030+*
30/10
16-Ball CSBGA
DS1856E-050+T&R
50/50
16 TSSOP
DS1856B-030+T&R*
30/10
16-Ball CSBGA
DS1856B-050+
50/50
16-Ball CSBGA
DS1856E-002
10/2.5
16 TSSOP
DS1856B-050+T&R
50/50
16-Ball CSBGA
DS1856E-002/T&R
10/2.5
16 TSSOP
10/2.5
16-Ball CSBGA
DS1856E-020*
20/20
16 TSSOP
DS1856B-002
DS1856E-020/T&R*
20/20
16 TSSOP
DS1856B-002/T&R
10/2.5
16-Ball CSBGA
DS1856B-020*
20/20
16-Ball CSBGA
DS1856E-002+
10/2.5
16 TSSOP
16-Ball CSBGA
DS1856E-002+T&R
10/2.5
16 TSSOP
16-Ball CSBGA
DS1856B-020/T&R*
20/20
DS1856E-020+*
20/20
16 TSSOP
DS1856B-002+
10/2.5
DS1856E-020+T&R*
20/20
16 TSSOP
DS1856B-002+T&R
10/2.5
16-Ball CSBGA
2.5/2.5
16 TSSOP
16 TSSOP
DS1856B-020+*
20/20
16-Ball CSBGA
DS1856E-025
DS1856B-020+T&R*
20/20
16-Ball CSBGA
DS1856E-025/T&R
2.5/2.5
DS1856E-030*
30/10
16 TSSOP
DS1856B-025
2.5/2.5
16-Ball CSBGA
2.5/2.5
16-Ball CSBGA
DS1856E-030/T&R*
30/10
16 TSSOP
DS1856B-025/T&R
DS1856B-030*
30/10
16-Ball CSBGA
DS1856E-025+
2.5/2.5
16 TSSOP
DS1856B-030/T&R*
30/10
16-Ball CSBGA
DS1856E-025+T&R
2.5/2.5
16 TSSOP
16 TSSOP
DS1856B-025+
2.5/2.5
16-Ball CSBGA
DS1856B-025+T&R
2.5/2.5
16-Ball CSBGA
DS1856E-030+*
30/10
Chip Information
TRANSISTOR COUNT: 51,061
SUBSTRATE CONNECTED TO GROUND
+Denotes lead free.
*Future product—contact factory for availability.
T&R denotes tape-and-reel.
All parts operate at the -40°C to +95°C temperature range.
Package Information
For the latest package outline information, go to
www.maxim-ic.com/DallasPackInfo.
Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are
implied. Maxim reserves the right to change the circuitry and specifications without notice at any time.
Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600 ____________________ 31
© 2005 Maxim Integrated Products
Printed USA
is a registered trademark of Maxim Integrated Products, Inc.
DALLAS is a registered trademark of Dallas Semiconductor Corporation.
DS1856
Ordering Information (continued)