XPPOWER ECE40US15

ACDC
20/40 Watts
ECE Series
xppower.com
•
Ultra Compact Size
•
Single Outputs from 3.3 to 48 V
•
Encapsulated
•
PCB & Chassis Mount Versions
•
Class II Construction
•
Peak Load Capability
•
3 Year Warranty
GREEN•POWER
Specification
Input
General
• 85-264 VAC (120-370 VDC) derate load
from 100% at 90 VAC to 90% at 85 VAC
Input Frequency
• 47-63 Hz
Input Current
• ECE20: 0.3 A rms at 230 VAC
ECE40: 0.5 A rms at 230 VAC
Power Factor
• EN61000-3-2 Class A
Inrush Current
• 20 A at 115 VAC, 40 A at 230 VAC,
cold start at 25 °C
Earth Leakage Current • Class II construction no earth
Input Protection
• ECE20: Internal T1 A/250 VAC fuse
ECE40: Internal T2 A/250 VAC fuse
No Load Input Power • <0.3 W
Input Voltage
Output
Output Voltage
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Line Regulation
Load Regulation
Transient Response
•
•
•
•
•
•
•
•
•
Ripple & Noise
•
Overvoltage Protection
Overload Protection
Short Circuit Protection
Temperature
Coefficient
22
•
•
•
•
See tables
±1%
No minimum load required
2 s max
16 ms max
8 ms minimum at full load & 115 VAC
±0.5% max
±1% max, ±2% max for ECE40US03/05-S
4% max deviation, recovery to within
1% in 500 µs for a 25% load change
3.3-5 V versions: 60 mV pk-pk,
3.3-5 V ‘ECE40-S’ versions: 75 mV
pk-pk (see note 5), all other models 1%
pk-pk max 20 MHz bandwidth
115-140% Vnom, auto recovery
110-180%
Trip and restart (Hiccup mode)
0.05%/°C
Efficiency
Isolation
Switching Frequency
Power Density
MTBF
•
•
•
•
See tables
3000 VAC Input to Output
70 kHz typical
ECE20: 9.97 W/In3
ECE40: 7.58 W/In3
• >450 kHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature • -25 °C to +70 °C, derate linearly from
100% at +50 °C to 50% at +70 °C
Cooling
• Convection-cooled
Operating Humidity
• 95% RH, non-condensing
Storage Temperature • -40 °C to +85 °C
Operating Altitude
• 3000 m
Vibration
• 2 g, 10 Hz to 500 kHz, 10 mins/cycle,
60 mins each cycle
EMC & Safety
Emissions
Harmonic Currents
ESD Immunity
Radiated Immunity
•
•
•
•
EFT/Burst
Surge
•
•
Conducted Immunity
Magnetic Fields
Dips & Interruptions
•
•
•
Safety Approvals
•
EN55022, level B conducted & radiated
EN61000-3-2, EN61000-3-3
EN61000-4-2, level 3 Perf Criteria A
EN61000-4-3, 10 V/m 80% mod
Perf Criteria A
EN61000-4-4, level 3 Perf Criteria A
EN61000-4-5, installation Class 3,
Perf Criteria A
EN61000-4-6, 10 Vrms Perf Criteria A
EN61000-4-8, 10 A/m Perf Criteria A
EN61000-4-11, 30% for 10 ms,
60% for 100 ms, 100% for 5000 ms
Perf Criteria A, B, B
EN60950-1, UL60950-1,
CSA22.2 No. 234 per cUL
Output Power
13.5
20.0
20.0
20.0
20.0
20.0
20.0
35.0
40.0
40.0
40.0
40.0
40.0
40.0
Output Current
Output Voltage
W
W
W
W
W
W
W
W
W
W
W
W
W
W
3.3
5.0
9.0
12.0
15.0
24.0
48.0
3.3
5.0
9.0
12.0
15.0
24.0
48.0
Nominal
4.50 A
4.00 A
2.22 A
1.67 A
1.33 A
0.83 A
0.42 A
9.00 A
8.00 A
4.44 A
3.33 A
2.67 A
1.67 A
0.83 A
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
Efficiency(4)
Peak(1)
5.85 A
5.20 A
2.89 A
2.17 A
1.73 A
1.08 A
0.55 A
11.70 A
10.40 A
5.77 A
4.33 A
3.47 A
2.17 A
1.08 A
ACDC
ECE20/40
Models and Ratings
Model Number
73%
77%
83%
82%
83%
82%
86%
73%
77%
80%
84%
84%
85%
86%
ECE20US03
ECE20US05
ECE20US09
ECE20US12
ECE20US15
ECE20US24
ECE20US48
ECE40US03(2)(3)
ECE40US05(2)(3)
ECE40US09(2)(3)
ECE40US12(2)(3)
ECE40US15(2)(3)
ECE40US24(2)(3)
ECE40US48(2)(3)
Notes
1. Peak load lasting <30 s with a maximum duty cycle of 10%, average output
power not to exceed nominal power.
2. Add suffix -S to model number to denote chassis mount with screw terminal type,
e.g. ECE40US12-S.Only available with ECE40 models.
3. A screw terminal versions (-S) is available with DIN Clip attached. Add suffix
‘D’, e.g. ECE40US24-SD. DIN Rail mounting clip is available as a separate
item, order code ECL25/30 DIN CLIP.
4. Average of efficiencies measured at 25%, 50%, 75% & 100% load with 230
VAC input.
5. 3.3 & 5 V ECE40-S versions meet 75 mV pk-pk with 20 MHz bandwidth and
0.1 µF capacitor across output terminals.
Mechanical Details
ECE20
ECE40
0.80 ±0.01
(20.3 ±0.3)
3.10 (78.7)
0.13
(3.4)
0.13 (3.2)
0.40 ±0.01
(10.1 ±0.3)
ACN
+Vo
ACN
TOP VIEW
1.07
(27.2)
1.50
(38.1)
-Vo
0.59
(15.0)
1.18
(30.0)
TOP VIEW
-Vo
ACL
0.16
(4.1)
1.80 ±0.01 (45.7 ±0.3)
2.06 (52.4)
ACL
0.13
(3.4)
+Vo
2.85 (72.4)
0.91
(23.0)
1.10
(27.9)
4x ø 0.04 (ø1.0)
4 x ø0.04 (ø1.0)
0.39
(10.0)
0.39 (10.0)
ECE40 Screw Terminal (S)
3.43 (87.0)
4x ø0.14
(4x ø3.5)
0.44
(11.2)
TOP VIEW
ACN
1.57
(40.0)
ACL
-Vo
0.84
(21.3)
1.20
+Vo
(30.5)
3.01 (76.4)
0.39 (10.0)
Notes
1. Dimensions in inches (mm).
2. Weight: ECE20: 0.13 lbs (60 g)
ECE40: 0.33 lbs (150 g)
ECE40 Optional Screw Terminal: 0.37 lbs (170 g)
3. Tolerances: x.xx = ± 0.02 (x.x = ± 0.5), x.xxx = ± 0.01 (x.xx = ± 0.25)
1º
1.12
(28.5)
0.27
(6.8)
0.10
(2.5)
3.78 (96.0)
Optional
DIN clip
23