60W Single Output Class 2 Switching Power Supply ELN-60 series Features : Universal AC input / Full range Protections: Short circuit / Over current / Over voltage Cooling by free air convection Built-in constant current limiting circuit with adjustable OCP level Optional dimming function : 1~10VDC (D type) or PWM (P type) controlled Fully isolated plastic case with IP64 level Class power unit, no FG Pass LPS Suitable for LED lighting and moving sign applications (Note.9) 100% full load burn-in test Low cost, high reliability 2 years warranty LPS IP64 SPECIFICATION MODEL DC VOLTAGE ELN-60-9 ELN-60-12 9V LED OPERATION VOLTAGE Note.8 3 ~ 9V 5A RATED CURRENT ( except for 48V ) ELN-60-15 ELN-60-24 ELN-60-27 ELN-60-48 12V 15V 24V 27V 48V 6 ~ 12V 7.5 ~ 15V 12 ~ 24V 13.5 ~ 27V 24 ~ 48V 5A 4A 2.5A 2.3A 1.3A 0 ~ 1.3A CURRENT RANGE 0 ~ 5A 0 ~ 5A 0 ~ 4A 0 ~ 2.5A 0 ~ 2.3A RATED POWER 45W 60W 60W 60W 62.1W 62.5W 120mVp-p 150mVp-p 150mVp-p 200mVp-p 250mVp-p 10.8 ~ 13.2V 13.5 ~ 16.5V 21.6 ~ 26.4V 24.3 ~ 29.7V 43.2 ~ 52.8V 87% 87% 88% RIPPLE & NOISE (max.) Note.2 120mVp-p OUTPUT ( for 48V only) VOLTAGE ADJ. RANGE Note.7 8.7 ~ 10.5V Can be adjusted by internal potentiometer SVR1 CURRENT ADJ. RANGE Note.7 -25% ~ 3%. Can be adjusted by internal potentiometer SVR2 VOLTAGE TOLERANCE Note.3 5.0% LINE REGULATION 1.0% 2.0% LOAD REGULATION SETUP, RISE TIME Note.6 500ms, 30ms / 230VAC 50ms/230VAC HOLD UP TIME (Typ.) VOLTAGE RANGE INPUT Note.4 90 ~ 264VAC 1500ms, 30ms / 115VAC at full load 16ms/115VAC at full load 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 82% AC CURRENT (Typ.) INRUSH CURRENT (max.) 1.2A/115VAC 0.7A/230VAC COLD START 60A/230VAC LEAKAGE CURRENT OVER CURRENT PROTECTION OVER VOLTAGE 85% 86% 0.25mA / 240VAC 95 ~ 110% Protection type : Constant current limiting, recovers automatically after fault condition is removed 11 ~ 13.5V 13.8 ~ 16V 17.5 ~ 21V 28 ~ 32V 31 ~ 35V 54 ~ 60V Protection type : Shut down o/p voltage, re-power on to recover FUNCTION DIMMING CONTROL (OPTIONAL) 1 ~ 10VDC or PWM signal : 100Hz ~ 3KHz WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY & EMC -40 ~ +80 0.03%/ , 10 ~ 95% RH (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL1310 Class 2, CAN/CSA C22.2 No. 223-M91(except for 48V), IP64 approved ; design refer to TUV EN60950-1, EN61347-2-13 WITHSTAND VOLTAGE I/P-O/P:3KVAC ISOLATION RESISTANCE I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A, EN61000-3-3 EMC EMISSION DIMENSION PACKING NOTE (Refer to "Derating Curve") 20 ~ 90% RH non-condensing SAFETY STANDARDS EMC IMMUNITY MTBF OTHERS -20 ~ +60 Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A 603Khrs min. MIL-HDBK-217F (25 181*61.5*35mm (L*W*H) 0.4Kg; 24pcs/11Kg/0.75CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the static characteristics for more details. 5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. Output voltage can be adjusted through the SVR1 on the PCB ; limit of output constant current level can be adjusted through the SVR2 on the PCB. 8. Constant current operation region is within the specified output voltage range above. This is the suitable operation region for LED related applications. 9. In the European market this product is only suitable for LED lighting applications that don't have to comply with the harmonic current requirements of EN61000-3-2 Class C. File Name:ELN-60-SPEC 2011-07-28 ELN-60 60W Single Output Class 2 Switching Power Supply Mechanical Specification Case No.960A series Unit:mm 181 21.25 6.26 300 20 2-R2.5 +V(Red) -V(Black) 61.5 300 20 SVT 18AWG 2C T case 15 SVT 18AWG 2C 116.5 21.25 AC/L(Brown) AC/N(Blue) 6.26 35 T case: Max. Case Temperature. OUTPUT(with optional dimming function) Output voltage and current adjustment : remove the upper case and adjust through SVR1 & SVR2 shown in the diagram. +V(Red) -V(Black) DIM+(Blue) DIM-(White) UL2464 18AWG 4C SVR1 SVR2 SVR1 Output voltage adjustment SVR2 Output current adjustment fosc : 60KHz Block Diagram EMI FILTER & RECTIFIERS I/P RECTIFIERS & FILTER POWER SWITCHING +V -V DIM- O.L.P. DETECTION CIRCUIT PWM CONTROL 10V PWM or 1~10V O.C.P. O.V.P. DIM+ Derating Curve Optional Dimming Control Static Characteristics 100 100 90 80 80 70 50 LOAD (%) LOAD (%) 60 40 20 -20 -15 -5 0 15 30 40 45 50 AMBIENT TEMPERATURE ( ) 60 (HORIZONTAL) 60 50 40 90 100 125 135 145 155 165 175 180 200 230 264 INPUT VOLTAGE (V) 60Hz File Name:ELN-60-SPEC 2011-07-28 ELN-60 60W Single Output Class 2 Switching Power Supply series Dimming Control (Optional) Level of output current can be adjusted through the dimming control function. When there is no signal sending to the control wires (open circuit between the two control wires), the power supply unit will operate as 0V (D-type) or 0% duty (P-type) of input signal and hence the output current will be zero. (1)1~10V (D type, & : ELN-60- 12 D) 95% DIM+ Output Current + Vdc DIMVdc: 1~10V 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 45% 5% 0% 0 1 2 3 4 5 6 7 8 9 10 DC Input (2)PWM (P type, & : ELN-60- 12 P) V Output Current f: 100Hz ~ 3KHz f 10V t1 t2 Duty= t1 ,0 ~ 100% t1+t2 Lo:0V Hi:10V f 95% 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 60% 15% 0% 0% 11% 20% 30% 40% 50% 60% 70% 80% 90% 100% Duty Cycle File Name:ELN-60-SPEC 2011-07-28