MEANWELL ESP-240

108W/216W Desktop Power Supply or Charger
ESC/ESP-120/240
series
Features :
AC input range selected by switch
Protections:Short circuit/Over load/Over voltage/Over temperature
Battery under/Over voltage and polarity protections(ESC only)
Forced air cooling by built-in DC fan(240V only)
Fixed switching frequency at 25KHz
3 color LED loading indicator
2 years warranty
SPECIFICATION
ESC/ESP-120
MODEL
OUTPUT
13.5V
27V
54V
13.5V
27V
RATED CURRENT
8A
4A
2A
16A
8A
4A
CURRENT RANGE
0 ~ 8A
0 ~ 4A
0 ~ 2A
0 ~ 16A
0 ~ 8A
0 ~ 4A
RATED POWER
108W
108W
108W
216W
216W
216W
150mVp-p
400mVp-p
120mVp-p
150mVp-p
400mVp-p
VOLTAGE ADJ. RANGE
12 ~ 15V
2.0%
24 ~ 30V
1.0%
48 ~ 56V
1.0%
12 ~ 15V
2.0%
24 ~ 30V
1.0%
48 ~ 56V
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
1.0%
0.5%
0.5%
LOAD REGULATION
2.0%
1.0%
0.5%
2.0%
1.0%
0.5%
SETUP, RISE TIME
FUNCTION
200ms, 100ms at full load
36ms at full load
VOLTAGE RANGE
88 ~ 132VAC/176 ~264VAC selected by switch
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
81%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
3A/115VAC
30ms at full load
83%
249 ~ 370VDC
84%
1.5A/230VAC
81%
84%
4.5A/115VAC
85%
2.5A/230VAC
COLD START 40A
<3.5mA / 240VAC
OVER LOAD
105 ~ 135% rated output power
Protection type : Fold back current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE
15.5 ~ 18.2V
31 ~ 36.5V
62.1 ~ 72.9V
15.5 ~ 18.2V
31 ~ 36.5V
Protection type : Constant voltage limiting, recovers automatically after fault condition is removed
OVER TEMPERATURE
RTH5 80
Detect on heatsink of Q1,Q2 power transistor
RTH5 85 Detect on heatsink of Q1,Q2 power transistor
Protection type : Shun down o/p voltage, recovers automatically after temperature goes down
BATTERY
FAN CONTROL
WORKING TEMP.
ENVIRONMENT
200ms, 100ms at full load
HOLD TIME (Typ.)
LEAKAGE CURRENT
PROTECTION
54V
RIPPLE & NOISE (max.) Note.2 120mVp-p
VOLTAGE TOLERANCE Note.3
INPUT
ESC/ESP-240
DC VOLTAGE
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
62.1 ~ 72.9V
ESC series with bat. polarity, bat. Under voltage, bat. Over voltage protection
NO FAN
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
VIBRATION
-20 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
WITHSTAND VOLTAGE
CSA60950-1(UL3101-1,IEC1010-1,EN61010-1) Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
RTH5
60
FAN ON, 50
FAN OFF
SAFETY & ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
EMC
(Note 4)
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
MTBF
OTHERS
NOTE
DIMENSION
PACKING
Compliance to EN61000-4-2,3,4; ENV50204, Light industry level, criteria A
215.8K hrs min.(ESC-120) 200.6K hrs min.(ESC-240) 250.9K Hrs min.(ESP-120) 226.6K Hrs min.(ESP-240)
150*140*86mm (L*W*H)
1.38Kg; 8pcs/12Kg/1.1CUFT(ESC-120)
1.5Kg; 8pcs/13Kg/1.1CUFT(ESC-240)
MIL-HDBK-217F (25 )
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:ESC/ESP-120/240-SPEC 2005-09-13
ESC/ESP-120/240
U S P - 2 2 5 s series
eries
108W/216W Desktop Power Supply or Charger
Mechanical Specification
Case No. 909E
Unit:mm
84
ESC/ESP-120
75
GREEN
YELLOW
RED
: LOW LOAD
: MID. LOAD
: HIGH LOAD
154
19
29
150
TEST SW.
HIGH EFFICIENCY SWITCH MODE BATTERY CHARGER
OVER LOAD & OVER TEMPERATURE PROTECTED
REVERSE POLARITY & OVER/UNDER VOLTAGE PROTECTED
38
7
ON
OFF
220V
140
7
75
ESC/ESP-240
GREEN
YELLOW
RED
: LOW LOAD
: MID. LOAD
: HIGH LOAD
HIGH EFFICIENCY SWITCH MODE BATTERY CHARGER
OVER LOAD & OVER TEMPERATURE PROTECTED
REVERSE POLARITY & OVER/UNDER VOLTAGE PROTECTED
TEST SW.
154
19
150
20
ON
OFF
220V
140
PIN+: DC OUTPUT +V
PIN-: DC OUTPUT COM
Derating Curve
Static Characteristics (ESP-120-27.6)
100
OUTPUT VOLTAGE (V)
80
ESC/ESP-120
LOAD (%)
60
40
20
-10
300
26
250
24
200
22
150
20
100
18
50
16
25
ESC/ESP-240
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60 (HORIZONTAL)
60
120
85
170
90
180
95
190
100
200
105
210
110
220
115
230
120
240
125
250
OUTPUT RIPPLE (mVp-p)
Ta=25
28
130
260
INPUT VOLTAGE (VAC) 60Hz
File Name:ESC/ESP-120/240-SPEC 2005-09-13