FTLX8551 Product Specification – November 2007 Product Specification RoHS-6 Compliant 10 Gb/s 850nm XPAK Transponder FTLX8551E3/ FTLX8551E3S/ FTLX8551F3 PRODUCT FEATURES Hot pluggable XPAK MSA form factor Total power consumption: 2.2 W maximum RoHS-6 compliant (lead-free) Temperature range 0°C to 70°C Transmission distance of 300m Uncooled 850 nm VCSEL laser LC connector, multimode fiber Full duplex transmission mode Digital Optics Monitoring (DOM) Power supply: +5.0 V, +3.3 V, Adaptable Power Supply (APS: +1.2 V) XAUI electrical interface - 4 x 3.125 Gb/s Ethernet (FTLX8551E3/E3S) - 4 x 3.1875 Gb/s Fibre Channel (FTLX8551F3) Management and control via MDIO 2-wire bus APPLICATIONS Low profile version for front panel mounting 10GBASE-SR ,10G Ethernet 70-pin connector (FTLX8551E3/E3S) De-latch mechanism with low 1200-Mx-SN-I Fibre Channel extraction force (FTLX8551F3) (FTLX8551x3 only) Part Number FTLX8551E3 FTLX8551E3S FTLX8551F3 PRODUCT SELECTION Application De-Latch Mechanism Ethernet Bail Release Ethernet Screw Mount Fibre Channel Bail Release © Finisar Corporation – November 2007 Rev. B Page 1 FTLX8551 Product Specification – November 2007 I. Pin Descriptions Signal Name Level I/O Management and Monitoring Ports MDIO Open Drain I/O Pin No. Description 17 MDC I 18 Management Data I/O. Requires external 10 - 22 kΩ pull-up to the APS on host. Management Data Clock Input 1 19 Port Address Input bit 4 I 20 Port Address Input bit 3 I 21 Port Address Input bit 2 I 22 Port Address Input bit 1 I 23 Port Address Input bit 0 LASI 1.2 V CMOS 1.2 V CMOS 1.2 V CMOS 1.2 V CMOS 1.2 V CMOS 1.2 V CMOS Open Drain O 9 RESET Open Drain I 10 Link Alarm Status Interrupt Output. Open Drain Compatible Output with 10 - 20 kΩ pull-up on host. Logic high = Normal Operation Logic low = Status Flag Triggered Reset Input. Open Drain Compatible Input with 22 kΩ pull-up to APS internal to transponder. Logic high = Normal Operation Logic low = RESET Vendor Specific Pins. Leave unconnected when not used. TX ON/OFF Input. Open Drain Compatible Input with 22 kΩ pull-up to APS internal to transponder. Logic high = Transmitter On Logic low = Transmitter Off Pulled low inside transponder through a 1 kΩ resistor to Ground PRTAD4 PRTAD3 PRTAD2 PRTAD1 PRTAD0 Vendor Specific TX ON/OFF 11,15,16,24 Open Drain MOD DETECT Transmit Functions Reserved Reserved TX LANE 3– AC-coupled, TX LANE 3+ Internally biased differential TX LANE 2– XAUI TX LANE 2+ TX LANE 1– TX LANE 1+ TX LANE 0– TX LANE 0+ I 12 O 14 I I I I 68 67 65 64 Reserved For Future Use Reserved For Future Use Module XAUI Input Lane 3– Module XAUI Input Lane 3+ I I I I I I 62 61 59 58 56 55 Module XAUI Input Lane 2– Module XAUI Input Lane 2+ Module XAUI Input Lane 1– Module XAUI Input Lane 1+ Module XAUI Input Lane 0– Module XAUI Input Lane 0+ © Finisar Corporation – November 2007 Rev. B Page 2 FTLX8551 Product Specification – November 2007 Pin Descriptions (continued) Signal Name Level Receive Functions Reserved Reserved RX LANE 0+ AC-coupled, RX LANE 0– Internally biased differential RX LANE 1+ XAUI RX LANE 1– RX LANE 2+ RX LANE 2– RX LANE 3+ RX LANE 3– DC Power GND 0 V DC APS APS SENSE I/O Pin No. Description O O O O O O O O O O 38 39 41 42 44 45 47 48 50 51 Reserved For Future Use Reserved For Future Use Module XAUI Output Lane 0+ Module XAUI Output Lane 0– Module XAUI Output Lane 1+ Module XAUI Output Lane 1– Module XAUI Output Lane 2+ Module XAUI Output Lane 2– Module XAUI Output Lane 3+ Module XAUI Output Lane 3– 1, 2, 3, 33, 34, 35, 36, 37, 40, 43, 46, 49, 52, 53, 54, 57, 60, 63, 66, 69, 70 7, 8, 28, 29 27 Ground connection for signal ground on the module +1.2 V +1.2 V APS SET 25 3.3 V +3.3 V DC 5, 6, 30, 31 5.0 V +5.0 V DC 4, 32 Reserved Reserved © Finisar Corporation – November 2007 Rev. B 26 13 Input from Adaptive Power Supply APS Sense Output. Connected to the APS input inside transponder. Feedback input from APS. Connected to GND through a 1180Ω resistor inside the transponder. DC Power Input, +3.3 V DC, Nominal DC Power Input, +5.0 V DC, Nominal Reserved for APD. Reserved. Page 3 FTLX8551 Product Specification – November 2007 Electrical Pad Layout Figure 1 - XPAK Transponder Electrical Pad Layout II. Absolute Maximum Ratings Parameter Storage Ambient Temperature1) Operating Case Temperature1) Supply Voltage +5.0 V Supply Voltage +3.3 V Supply Voltage APS Static Discharge Voltage, All Pins2) Average Receive Optical Power Notes: 1) 2) Symbol TS TC V5 V3 Vaps STd RxP max Limit Values min. max. -40 85 0 70 0 6 0 4 0 1.5 500 0 Unit °C °C V V V V dBm Non-condensing. HBM Exceeding any one of these values may permanently destroy the device. © Finisar Corporation – November 2007 Rev. B Page 4 FTLX8551 Product Specification – November 2007 III. Electrical Characteristics Recommended Operating Conditions Parameter Operating Case Temperature1) Transponder Total Power Consumption Supply Voltage +5.0 V Supply Current +5.0 V Supply Voltage +3.3 V Supply Current +3.3 V Supply Voltage APS Supply Current APS 1) Symbol TC P min. 0 VCC5 ICC5 VCC3 ICC3 VCC aps ICC aps 4.75 3.14 1.152 Values typ. 5.0 157 3.3 55 1.2 830 max. 70 2.2 Unit °C W 5.25 190 3.47 72 1.248 850 V mA V mA V mA Worst case thermal location, see also Environmental Performance. Electrical DC Characteristics (VCC5 = 4.75 V to 5.25 V, VCC3 = 3.14 V to 3.47 V, VCC aps = 1.152 V to 1.248 V, TC = 0°C to 70°C) Values Parameter Symbol min. typ. 1.2 V CMOS I/O DC Characteristics (PRTAD; LASI; RESET; TX_ONOFF) External Pull-up Resistor for Open Rpullup 10 Drain Output High Voltage2) Voh 1 Output Low Voltage2) Vol Input High Voltage Vih 0.84 Input Low Voltage Vil Input OFF Current3) Ipd -1 XAUI I/O DC Characteristics (TXLANE[0..3]; RXLANE[0..3]) max. Unit 22 kΩ 0.15 1.5 0.36 1 V V V V µA Differential Input Amplitude (pk-pk) 4) Vin_xaui Differential Output Amplitude (pkVout_xaui pk) 4) MDIO I/O DC Characteristics (MDIO; MDC) 160 800 2000 1600 mV mV Output Low Voltage5) Output Low Current Input High Voltage Input Low Voltage Pull-up Supply Voltage Input Capacitance Load Capacitance External Pull-up Resistance –0.3 0.2 20 1.5 0.36 1.5 10 470 V mA V V V pF pF Ω 2) 3) 4) 5) VOL IOL VIH VIL VPU CIN CLOAD RLOAD 0.84 –0.3 0.84 200 1.2 Rpull-up = 10 kΩ to 1.2 V. Vin = 1.2 V. AC coupled. IOL = 100 µA. © Finisar Corporation – November 2007 Rev. B Page 5 FTLX8551 Product Specification – November 2007 Electrical AC Characteristics (VCC5 = 4.75 V to 5.25 V, VCC3 = 3.14 V to 3.47 V, VCC aps = 1.152 V to 1.248 V, TC = 0°C to 70°C) Values Parameter Symbol Unit min. typ. max. XAUI Input AC Characteristics (TXLANE[0..3]) Baud Rate RXAUIIN Gbit/s Fibre Channel 3.1875 Ethernet 3.125 Baud Rate Tolerance RTOLXAUI –100 100 Ppm Differential Input Impedance ZINXAUI 80 100 120 Ω Differential Return Loss1) |S11| 10 dB Jitter Amplitude Tolerance3) JXAUITOL 0.65 UIp-p XAUI Output AC Characteristics (RXLANE[0..3]) Baud Rate RXAUIOUT Gbit/s Fibre Channel 3.1875 Ehernet 3.125 Baud Rate Variation RXAUIVAR –100 100 Ppm XAUI Eye Mask (far-end) According to IEEE and Fibre Channel Output Differential Impedance ZOUTXAUI 80 100 120 Ω Differential Output Return Loss1) |S22| 10 dB Total Jitter4) TJXAUI 0.4 UI Deterministic Jitter4) DJXAUI 0.17 UI Power-On Reset AC Characteristics Power-On Reset and TX_ONOFF According to XENPAK MSA Issue 3.0 2002-9-18 Characteristics MDIO I/O AC Characteristics (MDIO; MDC) MDIO Data Hold Time tHOLD 10 Ns MDIO Data Setup Time tSU 10 Ns Delay from MDC Rising Edge to tDELAY 150 Ns MDIO Data Change MDC Clock Rate ƒMAX 2.5 MHz 1) 2) 3) 4) 100 MHz to 2.5 GHz. At crossing point. Per IEEE Std 802.3ae. Far-end, measured values. © Finisar Corporation – November 2007 Rev. B Page 6 FTLX8551 Product Specification – November 2007 IV. Optical Characteristics (VCC5 = 4.75 V to 5.25 V, VCC3 = 3.14 V to 3.47 V, VCC aps = 1.152 V to 1.248 V, TC = 0°C to 70°C) Values Parameter Symbol Unit min. typ. max. Transmitter Launch Power in OMA1) PO-OMA –2.8 –1.5 dBm Average Launch Power1) PO-Avg –5 –1 dBm Center Wavelength Range1) λC-Tx 840 850 860 Nm 0.4 0.45 Nm RMS Spectral Width1) σI Extinction Ratio ER 3 5.5 dB Relative Intensity Noise12OMA RIN –128 dB/Hz Eye Mask Definition According to IEEE and Fibre Channel Encircled Flux EF at 19 µm ≥86%, at 4.5 µm ≤ 30% Optical Return Loss Tolerance ORLT 12 dB Average Launch Power of OFF PO-OFF –30 dBm Transmitter Receiver Stressed Receiver Sensitivity in OMA PIN-S –7.5 dBm Receiver Sensitivity in OMA2) PIN –11.1 dBm Average Receive Power PIN-max –1 dBm Signal Detect Deassert Level PSDL -14.5 dBm Signal Detect Assert Level PSD -18.0 dBm Signal Detect Hysteresis PSD 0.5 1.5 dB Receiver Reflectance REFRX –12 dB Center Wavelength Range λC-RX 840 860 Nm 1) Conforms to IEEE triple trade-off between center wavelength, RMS spectral width and minimum OMA. Per IEEE 802.3ae, Average Launch Power is informative only. 2) Receiver sensitivity, which is defined for an ideal input signal is informative only. V. General Specifications Optical Interface Standard Specifications IEEE Std 802.3ae-2002 clause 52, 10GBASE-SR Fibre Channel 10GFC Draft 4.0, 1200-M5-SN-I Fibre Channel 10GFC Draft 4.0, 1200-M5E-SN-I Fibre Channel 10GFC Draft 4.0, 1200-M6-SN-I XPAK MSA 2.3 Standard IEEE Fibre Channel 1) Fiber Type 62.5 µm MMF 50 µm MMF 62.5 µm MMF 50 µm MMF 50 µm MMF Minimum Modal Bandwidth at 850 nm (MHz*km) 160 500 200 500 2000 Operating Range 1) (meters) 2 to 26 2 to 66 0.5 to 33 0.5 to 82 0.5 to 300 Longer reaches possible depending upon link implementation. © Finisar Corporation – November 2007 Rev. B Page 7 FTLX8551 Product Specification – November 2007 Environmental Performance Operating case temperature: Operating humidity: 0°C to +70°C 0% -95% RH non-condensing Fibers and Connectors The transponder has LC receptacles for both Tx and Rx. The transponder is designed for multimode LC cables, 0° polished endface (PC). 70-pin Connector The module interface connector is a 70-pin, printed circuit board edge connection with a 0.5 mm pitch. The appropriate mating connector for the customer PCB is a 70-pin SMT, dual row, right angled, edge connector, 0.5 mm pitch (Tyco Electronics part number 1367337-1, Molex part number 74441-0003 or equivalent). Cage Requirement The cage assembly required to mount the XPAK module is defined by the MSA. Finisar recommends the low profile design –For correct operation and implementation always follow the manufacturer’s datasheet. A recommended XPAK rail assembly is Molex part number 74732-0220. Aqueous Wash Finisar XPAK transponders are neither solderable nor aqueous washable and are not intended for these processes. © Finisar Corporation – November 2007 Rev. B Page 8 FTLX8551 Product Specification – November 2007 VI. Regulatory Compliance Feature ESD: Electrostatic Discharge to the Electrical Pins (HBM) Immunity: Against Electrostatic Discharge (ESD) to the Module Receptacle Standard EIA/JESD22-A114-B (MIL-STD 883D Method 3015.7) EN 61000-4-2 IEC 61000-4-2 Immunity: Against Radio Frequency Electromagnetic Field EN 61000-4-3 IEC 61000-4-3 Emission: Electromagnetic Interference (EMI) FCC 47 CFR Part 15, Class B EN 55022 Class B CISPR 22 Compliant with 89/336/EEC FCC: Comments Class 1a (> 500 V) Discharges ranging from ±2 kV to ±15 kV to the front end / faceplate / receptacle cause no damage to module (under recommended conditions). With a field strength of 10 V/m, noise frequency ranges from 10 MHz to 2 GHz. No effect on module performance between the specification limits. Noise frequency range: 30 MHz to 40 GHz Radiated emission does not exceed specified limits when measured with module inside a shielding enclosure with MSA conform cutout. EN 55022 EN 55024 This device complies with part 15 of the FCC Class B Rules1). Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. 3. Must be used in a system housing. Eye Safety Finisar FTLX8551 transponders are Class 1 Laser Products. They are certified per the following standards: Feature Agency Standard Certificate Number Laser Eye FDA/CDRH CDRH 21 CFR 1040 and Laser Notice 9210176-77 Safety 50 Laser Eye TÜV EN 60825-1: 1994+A11:1996+A2:2001 R 72052602 Safety IEC 60825-1: 1993+A1:1997+A2:2001 IEC 60825-2: 2000, Edition 2 Electrical TÜV EN 60950 R 72052602 Safety Electrical UL/CSA CLASS 3862.07 1439230 Safety CLASS 3862.87 Copies of the referenced certificates will be available at Finisar Corporation upon request. © Finisar Corporation – November 2007 Rev. B Page 9 FTLX8551 Product Specification – November 2007 VII. DOM Parameters Parameter Transponder Temperature Monitor Accuracy1) Laser Bias Current Monitor Accuracy2) Transmit Power Monitor Accuracy3) Receive Power Monitor Accuracy 1) 2) 3) min. -5 -10 -3 -3 Values typ. max. +5 +10 +3 +3 Unit °C % dB dB 0 to 70°C case temperature. 0 to 12.5 mA. -1dBm to -3dBm. VIII. Mechanical Specifications Parameter Module Retention Force (latch strength) Module Insertion Force Module Extraction Force (with kick-out) Module Extraction Force (without kick-out) 0-80 UNF Screw Torque 1) 1) Symbol FRET FIN FEXT-K FEXT T0-80 UNF min. 1 0.84 Values typ. 200 40 16 25 max. 10 Unit N N N N cNm Two 0-80 UNF screws are used to secure the XPAK module (no bail de-latch version FTLX8551E3S) in the cage. Each XPAK module is shipped with the screws, and assembly is required after the insertion of the module into the cage. Package Outlines Figure 2 -XPAK with Bail De-Latch Mechanism © Finisar Corporation – November 2007 Rev. B Page 10 FTLX8551 Product Specification – November 2007 Figure 3 - XPAK with Screw Mount Assembly IX. References IEEE Std 802.3æ™-2002 clause 45 & 47 XPAK MSA 2.3 X. For More Information Finisar Corporation 1389 Moffett Park Drive Sunnyvale, CA 94089-1133 Tel. 1-408-548-1000 Fax 1-408-541-6138 [email protected] www.finisar.com © Finisar Corporation – November 2007 Rev. B Page 11