ETC G5S-1A-DC9

PCB Relay
G5S
Compact Single-pole Relay for
Switching Up To 5 A (Normally Open
Contact), Ideal for Fan Control of Air
Conditioners, and Heating Control of
Small Appliances
Compact relay with high insulation
between coil and contacts
Up to 5A switching on the NO contacts
Ensures a withstand impulse voltage of
8,000 V between the coil and contacts
Class B coil insulation available
Conforms to UL, CSA, and IEC (TÜV)
Ordering Information
Classification
Single
g contact
Enclosure rating
Part number
SPDT
Plastic-sealed
G5S-1 (-CB for Class B)
SPST-NO
Plastic-sealed
G5S-1A (-CB for class B)
Note: When ordering, add the rated coil voltage to the model number.
Example: G5S-1 DC12
Rated coil voltage
MODEL NUMBER LEGEND
---DC
G5S-
12 3 4
1. Contact Pole
1: Single pole
5
2. Contact Form
nil = 1 form C
A = 1 form A
3. Insulation class
nil = standard
CB = Class B
4. Enclosure
nil = plastic sealed
v = vented
5. Rated Coil Voltage
5, 9, 12, 18, 24, 48 VDC
G5S
G5S
Specifications
COIL RATINGS
Rated voltage
5 VDC
9 VDC
12 VDC
18 VDC
24 VDC
48 VDC
Rated current
80 mA
44.4 mA
33.3 mA
22.2 mA
16.7 mA
8.3 mA
Coil resistance
62.5 Ω
202.5 Ω
360 Ω
810 Ω
1,440 Ω
5,760 Ω
Must operate voltage
75% max. of rated voltage
Must release voltage
5% min. of rated voltage
Max. voltage
150% of rated voltage at 23°C, 110% of rated voltage at 70°C
Power consumption
Approx. 400 mW
Note: Rated current and coil resistance are measured at 23°C with a tolerance of ±10%.
CONTACT RATINGS
Load
Resistive load
Inductive load
Rated load
2 A (NO)/2 A (NC) at 277 VAC
5 A (NO)/3 A (NC) at 125 VAC
5 A (NO)/3 A (NC) at 30 VDC
0.5 A at 250 VAC, cosφ=0.4
1 A at 250 VAC, cosφ=0.8
0.8 A at 250 VAC, cosφ=0.9
Contact material
Ag
Rated carry current
5 A (NO)/3 A (NC)
Max. switching voltage
277 VAC, 30 VDC
Max. switching current
5 A (NO)/3 A (NC)
1A
Max. switching capacity
625 VA, 150 W (NO)
375 VA, 90 W (NC)
250 VA
Min. permissible load
10 mA at 5 VDC
Note: P level: λ60=0.1 x 10 --6 operation (with an operating frequency of 120 operations/min.)
CHARACTERISTICS
Contact resistance (See Note 2.)
100 mΩ max.
Operate time (See Note 3.)
10 ms max.
Release time (See Note 3.)
5 ms max.
Insulation resistance (See Note 4.)
1,000 MΩ min.
Dielectric strength
4,000 VAC, 50/60 Hz for 1 min between coil and contacts
750 VAC, 50/60 Hz for 1 min between contacts of same polarity
Impulse withstand voltage
8 kV (1.2 x 50 µs)
Vibration resistance
Destruction: 10 to 55 Hz, 1.5
1.5-mm
mm double am
amplitude
litude for 2 hours
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude for 5 minutes
Shock resistance
Destruction: 1,000 m/s2 (approx. 100G)
Malfunction: Energized: 100 m/s2 (approximately 10G)
Non-energized: 50 m/s2 (approximately 5G)
(This table continues on the next page.)
G5S
G5S
Characteristics Table -- continued from previous page
Mechanical
5,000,000 operations (18,000 operations per hour)
Electrical
200,000 operations: 1 A (NO)/1 A (NC) at 277-VAC resistive load
3 A (NO)/3 A (NC) at 125-VAC resistive load
100,000 operations: 0.8 A (NO)/0.8 A (NC) at 250 VAC, cosφ=0.9
5 A (NO)/3 A (NC) at 30-VDC resistive load
50,000 operations: 2 A (NO)/2 A (NC) at 277-VAC resistive load
5 A (NO)/3 A (NC) at 125-VAC resistive load
Switching
frequency
1,800 operations per hour
Ambient temperature
Operating &
storage
--40°C to 70°C (--40°F to 158°F) with no icing or condensation
--40°C to 85°C (class B) (--40°F to 185°F)
Ambient humidity
Operating &
storage
35% to 85%
Life expectancyy (See
Note 5.))
(
Weight
Note: 1.
2.
3.
4.
5.
Approx. 8.0 g
The data shown above are initial values.
The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method.
The operating time is possible with the rated voltage imposed with no contact bounce at an ambient temperature of 23°C.
The insulation resistance is possible between coil and contacts and between contacts of the same polarity at 500 VDC.
The electrical life data items shown are possible at 23°C.
APPROVED STANDARDS
UL508 (File No. E41515)
CSA C22.2 (No. 14) (File No. LR31928)
Model
Coil ratings
Contact ratings
Number of test operations
G5S-1 (-CB)
G5S-1A (-CB)
12, 24 VDC
0.8 A, 277 VAC (resistive)
0.5 A, 250 VAC (resistive)
2 A, 120 VAC (resistive)
2 A, 30 VDC (resistive)
5 A, 125 VAC (resistive)
1/10 HP, 125 VAC
5 A, 277 VAC (resistive)
1/6 HP, 277 VAC
0.3 A, 110 VDC (resistive)
5 A, 30 VDC (resistive)
6,000
TÜV (IEC 255, VDE0435 File No. R9650783)
Electrical life tests are performed at 70°C.
Model
Coil ratings
Contact ratings
Number of test operations
G5S-1 (-CB)
G5S-1A (-CB)
12, 24 VDC
1.5 A, 277 VAC (resistive)
1 A, 250 VAC (resistive)
2 A, 30 VDC (resistive)
30,000
100,000
30,000
1 A, 250 VAC, cosφ=0.8
0.5 A, 250 VAC, cosφ=0.4
1 A, 250 VAC, cosφ=0.8 (NO only)
1 A, 250 VAC, cosφ=0.8 (NC only)
100,000
30,000
200,000
200,000
Note: Pollution Degree 2, Overvoltage Category II, Material Group III
G5S
G5S
Engineering Data
MAX. SWITCHING CAPACITY
10
10
30-VDC resistive
load (NO)
125-VAC resistive
load (NO)
5
30-VDC resistive
load (NC)
Switching current (A)
Switching current (A)
3
2
1
277-VAC resistive
load (NO/NC)
125-VAC resistive
load (NC)
250-VAC resistive
load (NO/NC)
250-VAC inductive
load (cosφ=0.8)
1
0.5
250-VAC inductive
load (cosφ=0.4)
0
10
0
100
277
0
1,000
10
0
100
277
1,000
Switching voltage (V)
Switching voltage (V)
AMBIENT TEMPERATURE VS.
LIFE EXPECTANCY
MAXIMUM VOLTAGE
200
10,000
180
Life expectancy (x10 operations)
140
120
110
125 VAC
(NO only)
1,000
3
Maximum voltage (%)
160
100
80
60
40
100
250 VAC
(cosφ=0.9)
10
277 VAC
20
0
--40
--20
0
23
40
60
Ambient temperature (°C)
70
80
1
0
1
2
3
4
Switching current (A)
5
6
G5S
G5S
Dimensions
Unit: mm (inch)
G5S
SPDT
Terminal Arrangement/
Internal Connections
(Bottom View)
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
(See
Note.)
(See
Note.)
Direction marker
(See
Note.)
Five, 1.3±0.1-dia. holes
(No coil polarity)
Note: Values in parentheses are average values.
SPST-NO
Terminal Arrangement/
Internal Connections
(Bottom View)
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
(See
Note.)
(See
Note.)
(1.08)
(See
Note.)
Direction marker
Four, 1.3±0.1-dia. holes
(No coil polarity)
Note: Values in parentheses are average values.
Precautions
For general precautions on PCB Relays, refer to the precautions provided in General Information of the Relay Product Data Book.
! Caution
Do not touch the terminals of the Relay or the charted part of
the socket when power is supplied to the Relay. Otherwise, an
electric shock may occur.
G5S
G5S
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
OMRON ELECTRONICS, INC.
OMRON CANADA, INC.
One East Commerce Drive
Schaumburg, IL 60173
885 Milner Avenue
Scarborough, Ontario M1B 5V8
1-800-55-OMRON
416-286-6465
Cat. No. K102-E3-1
1/99
Specifications subject to change without notice.
Printed in U.S.A.