ETC 4.15282E+11

41 Series - Low-Profile P.C.B. Relays 8 - 12 - 16 A
41.31
41.52
41.61
- 1 pole
- low profile, 3.5 mm pinning
- PCB / for use with 95 series sockets
- 2 pole
- low profile, 5 mm pinning
- PCB / for use with 95 series sockets
- 1 pole
- low profile, 5 mm pinning
- PCB / for use with 95 series sockets
- Low-profile, only 15.7 mm high
- DC coil versions
- 8 mm, 6 kV(1.2/50 µs) between coil and
contacts
- Ambient temperature +85°C
- Sockets and accessories: see 95 and
99 series
A1
12 11 14
A2
22 21 24
12 14 22 24
11
11
A2
5
2.54
A2
11 (21)
5
20
29
A1
2.54
A2
5 5
7.5
=
=
1.3
7.5
=
1.3
0.8
12.7
15.7
3.8
0.6
22 21 24
21
=
3.5 3.5
A2
(22) 12 14 (24)
7.5
12.7
A1
A1
=
29
11
12 11 14
20
2.54
29
=
A2
A1
12.7
12 14
14
1.3
12
12.7
A1
20
29
* for 400 V applications, requirements for
pollution degree 2 are met.
Contact specifications
Contact configuration
Rated current/Maximum peak current
A
Rated voltage/Maximum switching voltage V AC
Rated load in AC1
VA
Rated load in AC15 (230 VAC)
VA
Single phase motor rating (230 VAC)
kW/HP
Breaking capacity in DC1: 30/110/220V
Minimum switching load
A
mW (V/mA)
Standard contact material
1 CO (SPDT)
2 CO (DPDT)
1 CO (SPDT)
12/25
8/15
16/30
250/400*
250/400*
250/400*
3,000
2,000
4,000
600
400
750
0.5/0.75
0.3/0.5
0.5/0.75
12/0.4/0.12
8/0.4/0.12
16/0.4/0.12
300 (5/5)
300 (5/5)
300 (5/5)
AgNi
AgNi
AgNi
—
—
—
12 - 24 - 48 - 60 - 110
12 - 24 - 48 - 60 - 110
12 - 24 - 48 - 60 - 110
—/0.4
—/0.4
—/0.4
Coil specifications
Nominal voltage (UN)
V AC (50/60 Hz)
V DC
Rated power AC/sens. DC
VA (50 Hz)/W
Operating range
AC (50 Hz)
DC
—
—
—
(0.7...2.5)UN
(0.7...2.5)UN
(0.7...2.5)UN
—/0.4UN
Holding voltage
AC/DC
—/0.4 UN
—/0.4 UN
Must drop-out voltage
AC/DC
—/0.1UN
—/0.1 UN
—/0.1 UN
Mechanical life AC/DC
cycles
—/30·106
—/30·106
—/30·106
Electrical life at rated load AC1
cycles
150 · 103
80 · 103
70 · 103
7/8
7/8
7/8
Insulation according to EN 61810-5
3.6kV/3
3.6kV/3
3.6kV/3
Insulation between coil and contacts (1.2/50µs) kV
6 (8mm)
6 (8mm)
6 (8mm)
Technical data
Operate/release time (bounce included)
Dielectric strenght between open contacts
Ambient temperature range
Protection category
Approvals: (according to type)
20
ms
V AC
°C
1,000
1,000
1,000
–40…+85
–40…+85
–40…+85
IP 50
IP 50
IP 50
GOST
41 Series - Low-Profile P.C.B. Relays 8 - 12 - 16 A
ORDERING INFORMATION
Example: a 41 series low-profile P.C.B. relay with 2 CO (DPDT) contacts, with coil rated 24 V DC.
A
4 1 . 5
2 . 9 . 0 2 4 . 0
Series
Type
3 = P.C.B. - 3.5 mm pinning
5 = P.C.B. - 5 mm pinning
6 = P.C.B. - 5 mm pinning
B
C
D
0
0
0
A: Contact material
0 = AgNi Standard
D: Special applications
0 = Standard
B: Contact circuit
0 = Standard
C: Options
0 = Standard
No. of poles
1 = 1 CO (SPDT) for
41.31, 12 A
41.61, 16A
2 = 2 CO (DPDT)
for 41.52, 8 A
Coil version
9 = DC
Coil voltage
see coil specifications
TECHNICAL DATA
INSULATION
INSULATION according to EN 61810-5
insulation rated voltage
V
rated impulse withstand voltage
kV
250
3.6
pollution degree
3
overvoltage category
III
OTHER DATA
VIBRATION RESISTANCE (10…55Hz): NO/NC
POWER LOST IN THE ENVIRONMENT
g/g
without contact current W
with rated current W
RECOMMENDED DISTANCE between RELAY mounted on P.C.B.s
mm
20/5
0.4
1.7 (41.31)
1.2 (41.52)
1.8 (41.61)
≥5
21
41 Series - Low-Profile P.C.B. Relays 8 - 12 - 16 A
CONTACT SPECIFICATIONS
F 41
CYCLES
10
7
DC BREAKING CURRENT (A)
10
H 41
6
10
5
10
4
2
1
0
8
4
12
20
1
2
3
10
6
4
2
B
A
1
0.2
0.1
20
16
60
100
140
180
220
DC VOLTAGE (V)
LOAD RATED CURRENT (A)
Contact life vs AC1 load.
1 - Type 41.52 (8 A) at 360 cycles/h.
2 - Type 41.31 (12 A) at 360 cycles/h.
2 - Type 41.61 (16 A) at 360 cycles/h.
Breaking capacity for DC1 load.
1 - type 41.61
2 - type 41.31
3 - type 41.52
A - load applied to 1 contact
B - load applied to 2 contacts in series
• When switching a resistive load (DC1) having voltage and
current values under the curve the expected electrical life is
≥ 100·103 cycles.
• In case of DC13 loads the connection of a diode in parallel with
the load will permit the same electrical life as for a DC1 load.
Note: the release time of load will be increase.
COIL SPECIFICATIONS
DC VERSION DATA
Nominal
voltage
UN
V
12
24
48
60
110
Coil
code
9.012
9.024
9.048
9.060
9.110
Operating range
Umin
V
8.4
16.8
33.6
42.0
77.0
Resistance Rated coil
absorption
R
I at UN
Ω
mA
360
33.3
1,440
19.7
5,520
8.7
7,340
8.1
26,600
4.1
Umax
V
30.6
61.2
122
153
280
R 41/1 DC
R 41/2 DC
U 2.5
UN
U 2.5
UN
2.0
2.0
1
41.31
41.61
1
1.5
1.5
1.0
1.0
2
2
0.5
-20
0
20
40
60
80
AMBIENT TEMPERATURE (°C)
Type 41.52 operating range vs ambient temperature.
1 - Max coil voltage permitted
2 - Min pick-up voltage with coil at ambient temperature
22
0.5
-20
0
20
40
60
80
AMBIENT TEMPERATURE (°C)
Type 41.31, 41.61 operating range vs ambient temperature.
1 - Max coil voltage permitted
2 - Min pick-up voltage with coil at ambient temperature
95 Series - Sockets and Accessories for 41 Series Relays
Relay type
Screw terminal socket: panel or 35 mm rail (EN 50022) mount
BLUE
BLACK*
95.05
Approvals
(according to type):
®
95.03.0
095.00.4
095.00.4
Modules
99.02
99.02
Timer modules
86.10, 86.20
86.10, 86.20
8-way jumper link for 95.03 and 95.05 sockets
095.18
095.18
US
75.3
60.9
1x4 / 2x2.5
1x14 / 2x12
=
17.5
Ø 3.2
A2
35.4
78.6
15.8
32
15.8
COM
21
11
COM
14
NO
24
14
NO
12
NC
22
12
NC
A1
COIL
A2
A1
COIL
11
95.05
95.03
99 Series modules for 95.03 and 95.05 sockets
BLUE
BLACK*
Diode
(6...220) V DC
99.02.3.000.00
99.02.3.000.00.0
Diode (inverted polarity)
(6...220) V DC
99.02.2.000.00
99.02.2.000.00.0
(6...24) V DC/AC
99.02.0.024.59
99.02.0.024.59.0
LED
99.02
17.5
=
1x6 / 2x2.5
AWG 1x14 / 2x12
Ø 3.2
28.3
flexible wire
22.4
28.3
solid wire
mm
95.03.0
Identification tag
- RATED VALUES: 10 A - 250 V
with a current >10 A, the contact terminal must be connected
in parallel (21 with 11, 24 with 14, 22 with 12)
- INSULATION: ≥ 6 kV (1.2/50µs) between coil and contacts
- PROTECTION CATEGORY: IP 20
- AMBIENT TEMPERATURE: (-40…+70) °C
- TORQUE: 0.5 Nm
- MAX WIRE SIZE:
2
41.52, 41.61
95.05
78.6
C
41.31
95.03
LED
(28...60) V DC/AC
99.02.0.060.59
99.02.0.060.59.0
LED
(110...240) V DC/AC
99.02.0.230.59
99.02.0.230.59.0
LED + Diode
(6...24) V DC
99.02.9.024.99
99.02.9.024.99.0
LED + Diode
(28...60) V DC
99.02.9.060.99
99.02.9.060.99.0
LED + Diode
(110...220) V DC
99.02.9.220.99
99.02.9.220.99.0
LED + Diode (inverted polarity)
(6...24) V DC
99.02.0.024.79
99.02.0.024.79.0
LED + Diode (inverted polarity)
(28...60) V DC
99.02.9.060.79
99.02.9.060.79.0
LED + Diode (inverted polarity)
(110...220) V DC
99.02.9.220.79
99.02.9.220.79.0
LED + Varistor
(6...24) V DC/AC
99.02.0.024.98
99.02.0.024.98.0
LED + Varistor
(28...60) V DC/AC
99.02.0.060.98
99.02.0.060.98.0
LED + Varistor
99.02.0.230.98.0
(110...240) V DC/AC
99.02.0.230.98
RC
(6...24) V DC/AC
99.02.0.024.09
99.02.0.024.09.0
RC
(28...60) V DC/AC
99.02.0.060.09
99.02.0.060.09.0
RC
(110...240) V DC/AC
99.02.0.230.09
99.02.0.230.09.0
(110...240) V AC
99.02.8.230.07
99.02.8.230.07.0
No - remanence
8-way jumper link for 95.03, and 95.05 sockets
095.18
15
*Available on request
15.8
15.8
15.8
15.8
15.8
15
10.3
- RATED VALUES: 10 A - 250 V
5.1
7
095.18
3.3
110.5
23
95 Series - Sockets and Accessories for 41 Series Relays
Relay type
P.C.B. socket
BLUE
BLACK*
95.13
41.31
41.52, 41.61
95.13
95.15
95.13.0
95.15.0
Metal retaining clip
095.41
095.41
Plastic retaining clip
095.42
095.42
4 10
13
®
13
7.5
55
95.13
24
*Available on request
30
20
3.5
1.5
RATED VALUES: 10 A - 250 V
INSULATION: ≥ 6 kV (1.2/50µs) between coil and contacts
PROTECTION CATEGORY: IP 20
AMBIENT TEMPERATURE: (-40…+70) °C
13
7.5
1.5
-
US
7.5
30
20
C
7.5
3.5
Approvals
(according to type):
Ø 3.2
30
30
Ø 3.2
95.15
4 10
13
95.15