41 Series - Low-Profile P.C.B. Relays 8 - 12 - 16 A 41.31 41.52 41.61 - 1 pole - low profile, 3.5 mm pinning - PCB / for use with 95 series sockets - 2 pole - low profile, 5 mm pinning - PCB / for use with 95 series sockets - 1 pole - low profile, 5 mm pinning - PCB / for use with 95 series sockets - Low-profile, only 15.7 mm high - DC coil versions - 8 mm, 6 kV(1.2/50 µs) between coil and contacts - Ambient temperature +85°C - Sockets and accessories: see 95 and 99 series A1 12 11 14 A2 22 21 24 12 14 22 24 11 11 A2 5 2.54 A2 11 (21) 5 20 29 A1 2.54 A2 5 5 7.5 = = 1.3 7.5 = 1.3 0.8 12.7 15.7 3.8 0.6 22 21 24 21 = 3.5 3.5 A2 (22) 12 14 (24) 7.5 12.7 A1 A1 = 29 11 12 11 14 20 2.54 29 = A2 A1 12.7 12 14 14 1.3 12 12.7 A1 20 29 * for 400 V applications, requirements for pollution degree 2 are met. Contact specifications Contact configuration Rated current/Maximum peak current A Rated voltage/Maximum switching voltage V AC Rated load in AC1 VA Rated load in AC15 (230 VAC) VA Single phase motor rating (230 VAC) kW/HP Breaking capacity in DC1: 30/110/220V Minimum switching load A mW (V/mA) Standard contact material 1 CO (SPDT) 2 CO (DPDT) 1 CO (SPDT) 12/25 8/15 16/30 250/400* 250/400* 250/400* 3,000 2,000 4,000 600 400 750 0.5/0.75 0.3/0.5 0.5/0.75 12/0.4/0.12 8/0.4/0.12 16/0.4/0.12 300 (5/5) 300 (5/5) 300 (5/5) AgNi AgNi AgNi — — — 12 - 24 - 48 - 60 - 110 12 - 24 - 48 - 60 - 110 12 - 24 - 48 - 60 - 110 —/0.4 —/0.4 —/0.4 Coil specifications Nominal voltage (UN) V AC (50/60 Hz) V DC Rated power AC/sens. DC VA (50 Hz)/W Operating range AC (50 Hz) DC — — — (0.7...2.5)UN (0.7...2.5)UN (0.7...2.5)UN —/0.4UN Holding voltage AC/DC —/0.4 UN —/0.4 UN Must drop-out voltage AC/DC —/0.1UN —/0.1 UN —/0.1 UN Mechanical life AC/DC cycles —/30·106 —/30·106 —/30·106 Electrical life at rated load AC1 cycles 150 · 103 80 · 103 70 · 103 7/8 7/8 7/8 Insulation according to EN 61810-5 3.6kV/3 3.6kV/3 3.6kV/3 Insulation between coil and contacts (1.2/50µs) kV 6 (8mm) 6 (8mm) 6 (8mm) Technical data Operate/release time (bounce included) Dielectric strenght between open contacts Ambient temperature range Protection category Approvals: (according to type) 20 ms V AC °C 1,000 1,000 1,000 –40…+85 –40…+85 –40…+85 IP 50 IP 50 IP 50 GOST 41 Series - Low-Profile P.C.B. Relays 8 - 12 - 16 A ORDERING INFORMATION Example: a 41 series low-profile P.C.B. relay with 2 CO (DPDT) contacts, with coil rated 24 V DC. A 4 1 . 5 2 . 9 . 0 2 4 . 0 Series Type 3 = P.C.B. - 3.5 mm pinning 5 = P.C.B. - 5 mm pinning 6 = P.C.B. - 5 mm pinning B C D 0 0 0 A: Contact material 0 = AgNi Standard D: Special applications 0 = Standard B: Contact circuit 0 = Standard C: Options 0 = Standard No. of poles 1 = 1 CO (SPDT) for 41.31, 12 A 41.61, 16A 2 = 2 CO (DPDT) for 41.52, 8 A Coil version 9 = DC Coil voltage see coil specifications TECHNICAL DATA INSULATION INSULATION according to EN 61810-5 insulation rated voltage V rated impulse withstand voltage kV 250 3.6 pollution degree 3 overvoltage category III OTHER DATA VIBRATION RESISTANCE (10…55Hz): NO/NC POWER LOST IN THE ENVIRONMENT g/g without contact current W with rated current W RECOMMENDED DISTANCE between RELAY mounted on P.C.B.s mm 20/5 0.4 1.7 (41.31) 1.2 (41.52) 1.8 (41.61) ≥5 21 41 Series - Low-Profile P.C.B. Relays 8 - 12 - 16 A CONTACT SPECIFICATIONS F 41 CYCLES 10 7 DC BREAKING CURRENT (A) 10 H 41 6 10 5 10 4 2 1 0 8 4 12 20 1 2 3 10 6 4 2 B A 1 0.2 0.1 20 16 60 100 140 180 220 DC VOLTAGE (V) LOAD RATED CURRENT (A) Contact life vs AC1 load. 1 - Type 41.52 (8 A) at 360 cycles/h. 2 - Type 41.31 (12 A) at 360 cycles/h. 2 - Type 41.61 (16 A) at 360 cycles/h. Breaking capacity for DC1 load. 1 - type 41.61 2 - type 41.31 3 - type 41.52 A - load applied to 1 contact B - load applied to 2 contacts in series • When switching a resistive load (DC1) having voltage and current values under the curve the expected electrical life is ≥ 100·103 cycles. • In case of DC13 loads the connection of a diode in parallel with the load will permit the same electrical life as for a DC1 load. Note: the release time of load will be increase. COIL SPECIFICATIONS DC VERSION DATA Nominal voltage UN V 12 24 48 60 110 Coil code 9.012 9.024 9.048 9.060 9.110 Operating range Umin V 8.4 16.8 33.6 42.0 77.0 Resistance Rated coil absorption R I at UN Ω mA 360 33.3 1,440 19.7 5,520 8.7 7,340 8.1 26,600 4.1 Umax V 30.6 61.2 122 153 280 R 41/1 DC R 41/2 DC U 2.5 UN U 2.5 UN 2.0 2.0 1 41.31 41.61 1 1.5 1.5 1.0 1.0 2 2 0.5 -20 0 20 40 60 80 AMBIENT TEMPERATURE (°C) Type 41.52 operating range vs ambient temperature. 1 - Max coil voltage permitted 2 - Min pick-up voltage with coil at ambient temperature 22 0.5 -20 0 20 40 60 80 AMBIENT TEMPERATURE (°C) Type 41.31, 41.61 operating range vs ambient temperature. 1 - Max coil voltage permitted 2 - Min pick-up voltage with coil at ambient temperature 95 Series - Sockets and Accessories for 41 Series Relays Relay type Screw terminal socket: panel or 35 mm rail (EN 50022) mount BLUE BLACK* 95.05 Approvals (according to type): ® 95.03.0 095.00.4 095.00.4 Modules 99.02 99.02 Timer modules 86.10, 86.20 86.10, 86.20 8-way jumper link for 95.03 and 95.05 sockets 095.18 095.18 US 75.3 60.9 1x4 / 2x2.5 1x14 / 2x12 = 17.5 Ø 3.2 A2 35.4 78.6 15.8 32 15.8 COM 21 11 COM 14 NO 24 14 NO 12 NC 22 12 NC A1 COIL A2 A1 COIL 11 95.05 95.03 99 Series modules for 95.03 and 95.05 sockets BLUE BLACK* Diode (6...220) V DC 99.02.3.000.00 99.02.3.000.00.0 Diode (inverted polarity) (6...220) V DC 99.02.2.000.00 99.02.2.000.00.0 (6...24) V DC/AC 99.02.0.024.59 99.02.0.024.59.0 LED 99.02 17.5 = 1x6 / 2x2.5 AWG 1x14 / 2x12 Ø 3.2 28.3 flexible wire 22.4 28.3 solid wire mm 95.03.0 Identification tag - RATED VALUES: 10 A - 250 V with a current >10 A, the contact terminal must be connected in parallel (21 with 11, 24 with 14, 22 with 12) - INSULATION: ≥ 6 kV (1.2/50µs) between coil and contacts - PROTECTION CATEGORY: IP 20 - AMBIENT TEMPERATURE: (-40…+70) °C - TORQUE: 0.5 Nm - MAX WIRE SIZE: 2 41.52, 41.61 95.05 78.6 C 41.31 95.03 LED (28...60) V DC/AC 99.02.0.060.59 99.02.0.060.59.0 LED (110...240) V DC/AC 99.02.0.230.59 99.02.0.230.59.0 LED + Diode (6...24) V DC 99.02.9.024.99 99.02.9.024.99.0 LED + Diode (28...60) V DC 99.02.9.060.99 99.02.9.060.99.0 LED + Diode (110...220) V DC 99.02.9.220.99 99.02.9.220.99.0 LED + Diode (inverted polarity) (6...24) V DC 99.02.0.024.79 99.02.0.024.79.0 LED + Diode (inverted polarity) (28...60) V DC 99.02.9.060.79 99.02.9.060.79.0 LED + Diode (inverted polarity) (110...220) V DC 99.02.9.220.79 99.02.9.220.79.0 LED + Varistor (6...24) V DC/AC 99.02.0.024.98 99.02.0.024.98.0 LED + Varistor (28...60) V DC/AC 99.02.0.060.98 99.02.0.060.98.0 LED + Varistor 99.02.0.230.98.0 (110...240) V DC/AC 99.02.0.230.98 RC (6...24) V DC/AC 99.02.0.024.09 99.02.0.024.09.0 RC (28...60) V DC/AC 99.02.0.060.09 99.02.0.060.09.0 RC (110...240) V DC/AC 99.02.0.230.09 99.02.0.230.09.0 (110...240) V AC 99.02.8.230.07 99.02.8.230.07.0 No - remanence 8-way jumper link for 95.03, and 95.05 sockets 095.18 15 *Available on request 15.8 15.8 15.8 15.8 15.8 15 10.3 - RATED VALUES: 10 A - 250 V 5.1 7 095.18 3.3 110.5 23 95 Series - Sockets and Accessories for 41 Series Relays Relay type P.C.B. socket BLUE BLACK* 95.13 41.31 41.52, 41.61 95.13 95.15 95.13.0 95.15.0 Metal retaining clip 095.41 095.41 Plastic retaining clip 095.42 095.42 4 10 13 ® 13 7.5 55 95.13 24 *Available on request 30 20 3.5 1.5 RATED VALUES: 10 A - 250 V INSULATION: ≥ 6 kV (1.2/50µs) between coil and contacts PROTECTION CATEGORY: IP 20 AMBIENT TEMPERATURE: (-40…+70) °C 13 7.5 1.5 - US 7.5 30 20 C 7.5 3.5 Approvals (according to type): Ø 3.2 30 30 Ø 3.2 95.15 4 10 13 95.15