OMRON G6M-1A-DC24

PCB Power Relay
G6M
Slim, Miniature Relay, Capable of
Relaying Programmable Controller and
Temperature Controller Outputs
• Slim 5-mm width, and miniature size.
• Reduced mounting area ideal for high-density mounting.
• Highly efficient magnetic circuit for high sensitivity (40%
higher than the G6D, with power consumption of 120 mW).
• Satisfies IEC61131-2 and IEC61010 requirements.
• SIL (single-in-line) terminal pitch.
• UL, CSA approved. VDE approval pending.
• RoHS Compliant.
Ordering Information
Classification
Standard
Contact form
Enclosure ratings
SPST-NO
Note: When ordering, add the rated coil voltage to the model number.
Example: G6M-1A DC 12
Rated coil voltage
Model Number Legend
G6M-@ @ -DC@
1 2
3
Model
Fully sealed
G6M-1A
1. Number of Poles
1:
1 pole
2. Contact Form
A:
SPST-NO
3. Rated Coil Voltage
5, 12, 24 VDC
Specifications
■ Coil Ratings
Rated voltage
5 VDC
12 VDC
24 VDC
Rated current
24 mA
10 mA
5 mA
Coil resistance
208 Ω
1,200 Ω
4,800 Ω
Must operate voltage
75% max. of rated voltage
Must release voltage
5% min. of rated voltage
Max. voltage
160% of rated voltage (at 23° C)
Power consumption
Approx. 120 mW
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23° C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23° C.
3. The maximum allowable voltage is the maximum possible value of the voltage that can be applied to the relay coil. It is not the maximum
voltage that can be applied continuously.
4. The must operate voltage is 72% or less of the rated voltage if the relay is mounted vertically and the terminals are pointed downwards.
PCB Power Relay
G6M
1
■ Contact Ratings
Rated load
3 A at 250 VAC, 3 A at 30 VDC
Rated carry current
5A
Max. switching voltage
270 VAC, 125 VDC
Max. switching current
5A
Max. switching power
750 VAC, 90 W
Min. permissible load
10 mA at 5 VDC (at 120 operations/min)
Note: P level: λ60 = 0.1 x 10 /operation
-6
■ Characteristics
Contact resistance
100 mΩ max.
Operate time
10 ms max.
Release time
5 ms max.
Insulation resistance
1,000 MΩ min. (at 500 VDC)
Dielectric strength
3,000 VAC, 50/60 Hz for 1 min between coil and contacts
750 VAC, 50/60 Hz for 1 min between contacts of same polarity
Impulse withstand voltage
5,080 V (1.2 x 50 µs) between coil and contacts
Vibration resistance
Destruction: 10 to 55 Hz, 2.5-mm single amplitude (5.0-mm double amplitude)
Malfunction: 10 to 55 hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance
Destruction: 1,000 m/s2
Malfunction: 100 m/s2
Endurance
Mechanical: 20,000,000 operations min. (at 18,000 operations/hr)
Electrical: 100,000 operations min. (3A at 250 VAC/30 VDC, resistive load)
Ambient temperature
Operating: -40° C to 85° C (with no icing)
Ambient humidity
Operating: 5% to 85%
Weight approx.
4g
■ Approved Standards
UL508 (File No. E41515)/CSA C22.2 (No. 14) (File No. LR31928)
Model
Coil ratings
G6M-1A
2
4.5 to 24 VDC
PCB Power Relay
G6M
Contact ratings
5A, 250 VAC (resistive load, 6,000 operations)
5 A, 24 VDC (resistive load, 6,000 operations)
3 A, 250 VAC (general use, 100,000 operations)
3 A, 24 VDC (general use, 100,000 operations)
Engineering Data
Dimensions
PCB Power Relay
G6M
3