PCB Relay G5S Compact Single-pole Relay for Switching Up To 5 A (Normally Open Contact), Ideal for Fan Control of Air Conditioners, and Heating Control of Small Appliances Compact relay with high insulation between coil and contacts Up to 5A switching on the NO contacts Ensures a withstand impulse voltage of 8,000 V between the coil and contacts Class B coil insulation available Conforms to UL, CSA, and IEC (TÜV) Ordering Information Classification Single g contact Enclosure rating Part number SPDT Plastic-sealed G5S-1 (-CB for Class B) SPST-NO Plastic-sealed G5S-1A (-CB for class B) Note: When ordering, add the rated coil voltage to the model number. Example: G5S-1 DC12 Rated coil voltage MODEL NUMBER LEGEND ---DC G5S- 12 3 4 1. Contact Pole 1: Single pole 5 2. Contact Form nil = 1 form C A = 1 form A 3. Insulation class nil = standard CB = Class B 4. Enclosure nil = plastic sealed v = vented 5. Rated Coil Voltage 5, 9, 12, 18, 24, 48 VDC G5S G5S Specifications COIL RATINGS Rated voltage 5 VDC 9 VDC 12 VDC 18 VDC 24 VDC 48 VDC Rated current 80 mA 44.4 mA 33.3 mA 22.2 mA 16.7 mA 8.3 mA Coil resistance 62.5 Ω 202.5 Ω 360 Ω 810 Ω 1,440 Ω 5,760 Ω Must operate voltage 75% max. of rated voltage Must release voltage 5% min. of rated voltage Max. voltage 150% of rated voltage at 23°C, 110% of rated voltage at 70°C Power consumption Approx. 400 mW Note: Rated current and coil resistance are measured at 23°C with a tolerance of ±10%. CONTACT RATINGS Load Resistive load Inductive load Rated load 2 A (NO)/2 A (NC) at 277 VAC 5 A (NO)/3 A (NC) at 125 VAC 5 A (NO)/3 A (NC) at 30 VDC 0.5 A at 250 VAC, cosφ=0.4 1 A at 250 VAC, cosφ=0.8 0.8 A at 250 VAC, cosφ=0.9 Contact material Ag Rated carry current 5 A (NO)/3 A (NC) Max. switching voltage 277 VAC, 30 VDC Max. switching current 5 A (NO)/3 A (NC) 1A Max. switching capacity 625 VA, 150 W (NO) 375 VA, 90 W (NC) 250 VA Min. permissible load 10 mA at 5 VDC Note: P level: λ60=0.1 x 10 --6 operation (with an operating frequency of 120 operations/min.) CHARACTERISTICS Contact resistance (See Note 2.) 100 mΩ max. Operate time (See Note 3.) 10 ms max. Release time (See Note 3.) 5 ms max. Insulation resistance (See Note 4.) 1,000 MΩ min. Dielectric strength 4,000 VAC, 50/60 Hz for 1 min between coil and contacts 750 VAC, 50/60 Hz for 1 min between contacts of same polarity Impulse withstand voltage 8 kV (1.2 x 50 µs) Vibration resistance Destruction: 10 to 55 Hz, 1.5 1.5-mm mm double am amplitude litude for 2 hours Malfunction: 10 to 55 Hz, 1.5-mm double amplitude for 5 minutes Shock resistance Destruction: 1,000 m/s2 (approx. 100G) Malfunction: Energized: 100 m/s2 (approximately 10G) Non-energized: 50 m/s2 (approximately 5G) (This table continues on the next page.) G5S G5S Characteristics Table -- continued from previous page Mechanical 5,000,000 operations (18,000 operations per hour) Electrical 200,000 operations: 1 A (NO)/1 A (NC) at 277-VAC resistive load 3 A (NO)/3 A (NC) at 125-VAC resistive load 100,000 operations: 0.8 A (NO)/0.8 A (NC) at 250 VAC, cosφ=0.9 5 A (NO)/3 A (NC) at 30-VDC resistive load 50,000 operations: 2 A (NO)/2 A (NC) at 277-VAC resistive load 5 A (NO)/3 A (NC) at 125-VAC resistive load Switching frequency 1,800 operations per hour Ambient temperature Operating & storage --40°C to 70°C (--40°F to 158°F) with no icing or condensation --40°C to 85°C (class B) (--40°F to 185°F) Ambient humidity Operating & storage 35% to 85% Life expectancyy (See Note 5.)) ( Weight Note: 1. 2. 3. 4. 5. Approx. 8.0 g The data shown above are initial values. The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method. The operating time is possible with the rated voltage imposed with no contact bounce at an ambient temperature of 23°C. The insulation resistance is possible between coil and contacts and between contacts of the same polarity at 500 VDC. The electrical life data items shown are possible at 23°C. APPROVED STANDARDS UL508 (File No. E41515) CSA C22.2 (No. 14) (File No. LR31928) Model Coil ratings Contact ratings Number of test operations G5S-1 (-CB) G5S-1A (-CB) 12, 24 VDC 0.8 A, 277 VAC (resistive) 0.5 A, 250 VAC (resistive) 2 A, 120 VAC (resistive) 2 A, 30 VDC (resistive) 5 A, 125 VAC (resistive) 1/10 HP, 125 VAC 5 A, 277 VAC (resistive) 1/6 HP, 277 VAC 0.3 A, 110 VDC (resistive) 5 A, 30 VDC (resistive) 6,000 TÜV (IEC 255, VDE0435 File No. R9650783) Electrical life tests are performed at 70°C. Model Coil ratings Contact ratings Number of test operations G5S-1 (-CB) G5S-1A (-CB) 12, 24 VDC 1.5 A, 277 VAC (resistive) 1 A, 250 VAC (resistive) 2 A, 30 VDC (resistive) 30,000 100,000 30,000 1 A, 250 VAC, cosφ=0.8 0.5 A, 250 VAC, cosφ=0.4 1 A, 250 VAC, cosφ=0.8 (NO only) 1 A, 250 VAC, cosφ=0.8 (NC only) 100,000 30,000 200,000 200,000 Note: Pollution Degree 2, Overvoltage Category II, Material Group III G5S G5S Engineering Data MAX. SWITCHING CAPACITY 10 10 30-VDC resistive load (NO) 125-VAC resistive load (NO) 5 30-VDC resistive load (NC) Switching current (A) Switching current (A) 3 2 1 277-VAC resistive load (NO/NC) 125-VAC resistive load (NC) 250-VAC resistive load (NO/NC) 250-VAC inductive load (cosφ=0.8) 1 0.5 250-VAC inductive load (cosφ=0.4) 0 10 0 100 277 0 1,000 10 0 100 277 1,000 Switching voltage (V) Switching voltage (V) AMBIENT TEMPERATURE VS. LIFE EXPECTANCY MAXIMUM VOLTAGE 200 10,000 180 Life expectancy (x10 operations) 140 120 110 125 VAC (NO only) 1,000 3 Maximum voltage (%) 160 100 80 60 40 100 250 VAC (cosφ=0.9) 10 277 VAC 20 0 --40 --20 0 23 40 60 Ambient temperature (°C) 70 80 1 0 1 2 3 4 Switching current (A) 5 6 G5S G5S Dimensions Unit: mm (inch) G5S SPDT Terminal Arrangement/ Internal Connections (Bottom View) PCB Mounting Holes (Bottom View) Tolerance: ±0.1 mm (See Note.) (See Note.) Direction marker (See Note.) Five, 1.3±0.1-dia. holes (No coil polarity) Note: Values in parentheses are average values. SPST-NO Terminal Arrangement/ Internal Connections (Bottom View) PCB Mounting Holes (Bottom View) Tolerance: ±0.1 mm (See Note.) (See Note.) (1.08) (See Note.) Direction marker Four, 1.3±0.1-dia. holes (No coil polarity) Note: Values in parentheses are average values. Precautions For general precautions on PCB Relays, refer to the precautions provided in General Information of the Relay Product Data Book. ! Caution Do not touch the terminals of the Relay or the charted part of the socket when power is supplied to the Relay. Otherwise, an electric shock may occur. G5S G5S NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4. OMRON ELECTRONICS, INC. OMRON CANADA, INC. One East Commerce Drive Schaumburg, IL 60173 885 Milner Avenue Scarborough, Ontario M1B 5V8 1-800-55-OMRON 416-286-6465 Cat. No. K102-E3-1 1/99 Specifications subject to change without notice. Printed in U.S.A.