STMICROELECTRONICS GS

GS-R1012
120W STEP-DOWN SWITCHING REGULATOR
Type
GS-R1012
Vi
Vo
Io
18 to 36 V
12 V
10 A
FEATURES
Wide input voltage range (18 to 36V)
High efficiency (90% min.)
Parallel operation with current sharing
Synchronization
Remote inhibit/enable
Remote load voltage sense
Output short-circuit protection
Soft-start
PCB or chassis mountable
DESCRIPTION
The GS-R1012 is a step-down switching voltage
regulator suitable to provide 12V/10A output voltage from a wide input voltage range (18 to 36V).
ABSOLUTE MAXIMUM RATINGS
Symbol
Vi
Parameter
DC Input Voltage
Viinh
High Inhibit voltage
Tstg
Storage Temperature Range
Tcop
Operating Case Temperature Range
June 1994
Value
Unit
40
V
28
V
– 20 to +105
°C
0 to +75
°C
1/7
GS-R1012
ELECTRICAL CHARACTERISTICS (Tamb = 25°C unless otherwise specified)
Parameter
Symbol
Test Conditions
Vi
Input Voltage
Vo = 12V
li
Input Current
Vi = 24V
Io = 1.5 to 10A
lir
Reflected Input Current
Vi = 24V
Io = 10A
with external filter (C = 1000µF)
Min
18
Io = 10A
Typ
Max
24
36
5,6
400
Unit
V
A
500
mApp
Vien
Enable Input Voltage
Vi = 18 to 36V Io = 1.5 to 10A
0
1.2
V
Viinh
Inhibit Input Voltage
Vi = 18 to 36V Io = 1.5 to 10A
2
24
V
liinh
Inhibit Input Current
Vi = 18 to 36V Io =1.5 to 10A
Viinh = 5V
0.3
0.5
mA
12
12.6
Vo
Output Voltage
Vi = 18 to 36V Io = 1.5 to 10A
Vor
Output Ripple
Voltage
Vi = 24V
Io = 10A
Line Regulation
Vi = 18 to 36V Io = 10A
δVOL
11.4
150
δVOO
Load Regulation
Vi = 24V
∆Vo
Remote Sense
Compensation
Vi = 24V
Io = 10A
Io
Output Current*
Vi = 18 to 36V
Iol
Output Current
Limiting
Vi = 18 to 36V
Iosc
Short-circuit Output
Current
δIo
Io = 1.5 to 10A
0.5
%
1
%
0.5
V
0
10
A
10.5
11.5
A
Vi = 24V
16
A
Current Sharing
Deviation
Vi = 24V
Io = 2 to 10A two modules in
parallel
10
%
tss
Soft-start Time
Vi = 24V
tr1
Line Transient
Recovery Time
tr2
fs
η
R thc
Vo = 12V
Io = 10A
15
ms
Vi = 15 to 36V
Io = 5A
60
µs
Load Transient
Recovery Time
Vi = 24V
Io = 1.5 to 10A
100
µs
Switching Frequency
Vi = 24V
Io = 1.5 to 10A
100
kHz
Efficiency
Vi = 18 to 36V
Io = 10A
90
Thermal Resistance
Case-to-ambient
* Note: when output current is less than 1.5A, output ripple voltage increases due to discontinuous operation.
2/7
V
mVpp
92
%
7.5
°C/W
GS-R1012
CONNECTION DIAGRAM AND MECHANICAL DATA
Dimensions in mm (inches).
PIN DESCRIPTION
Pin
Function
Description
1
GND Input
2
Inhibit
The converter is ON (Enable) when this pin is unconnected or the voltage applied is lower
than 1.2V. The converter is OFF (Inhibit) for a control voltage in the range of 2 to 24V.
3
+ Vin
DC Input voltage; recommended maximum voltage is 36V.
External capacitor between pin 3 and pin 1 is mandatory; recommended value is
1000µF/50V for switching application.
4,5
+ Vout
+12V output voltage.
6
+ Sense
Senses the remote load high side. To be connected to pin 4,5 when remote sense is not
used.
7
Sync
Synchronization output. See figures 1,2,3,4. Take care to leave the pin open when is not
used.
8
Parallel
Parallel output. See figures 1,2,3,4. Take care to leave the pin open when is not used.
9
- Sense
Senses the remote load return. To be connected to pin 10,11 when remote sense is not
used. In parallel configuration, take care to connect all -S pins together (see figures 1,2,3,4).
10,11
GND Output
Return for input voltage source. Internally connected to pin 10,11.
Return for output current path. Internally connected to pin 1.
3/7
GS-R1012
USER NOTES
Input Voltage
The recommended operating maximum DC input
voltage is 36V inclusive of the ripple voltage. The
use of an external low ESR, high ripple current
capacitor located as close the module as possible
is mandatory; recommended value is 1000µF/50V.
Softstart
To avoid heavy inrush current the output voltage
rise time is typically 15ms in any condition of load.
Remote Sensing
The remote voltage sense compensation range is
for a total drop of 500mV equally shared between
the load connecting wires. It is a good practice to
shield the sensing wires to avoid oscillations. See
the connection diagram on figures 1, 2, 3, 4.
Figure 1.
4/7
Parallel Operation
To increase available output regulated power, the
module features the parallel connection possibility
with equal current sharing and maximum deviation
of 10% (two modules in parallel). See the connection diagram on figures 1, 2, 3, 4.
Module Protection
The module is protected against occasional and
permanent shortcircuits of the output pins to
ground, as well as against output current overload.
It uses a current limiting protection circuitry, avoiding latch-up problems with certain types of loads.
Figure 2.
GS-R1012
Figure 3.
Figure 4.
Thermal characterist ics: how to choose the
heat-sink
Sometimes the GS-R1012 requires an external
heat-sink depending both operating temperature
conditions and power.
Before entering into calculations details, some basic concepts will be explained to better understand
the problem.
The thermal resistance between two points is represented by their temperature difference in front of
a specified dissipated power, and it is expressed in
Degree Centigrade per Watt (°C/W).
For GS-R1012 the thermal resistance case to ambient is 7.5°C/W. This means that an internal power
dissipation of 1W will bring the case temperature at
7.5°C above the ambient temperature.
The maximum case temperature to which the module provides 10A is 75°C (see fig. 6).
Let’s suppose to have a GS-R1012 that delivers a
load current of 10A at an ambient temperature of
40°C.
The dissipated power in this operating condition is
about 10.4W (at typical efficiency of 92%), and the
case temperature of the module will be:
TCase = TAmb + Pd × Rth = 40 + 10.4 × 7.5 = 118°C
This value exceeds the maximum allowed temperature and an external heat-sink must be added. To
this purpose four holes (see mechanical drawing)
are provided on the metal surface of the module.
To calculate this heat-sink, let’s first determine what
the total thermal resistance should be.
Rth = TCaseMAX − Tamb = 75 − 40 = 3.37°C / W
Pd
10.4
This value is the resulting value of the additional
heatsink thermal resistance.
5/7
GS-R1012
Figure 5. - Efficiency vs. Output Current.
Typ. eff. (%)
98
97
96
95
94
Vi= 18V
93
92
Vi= 24V
91
Vi= 36V
90
89
88
0
1
2
3
Figure 6. - Output Current vs. T case.
6/7
4
5
6
7
8
9
10
GS-R1012
The following list may help the designer to select
the proper commercially available heat-sink.
Sometimes it can be more convenient to use a
custom made heat-sink that can be experimently
designed and tested.
Manufacturers
Type
ALUTRONIC
PR139
20
3
PR140
19
2
PR159
20
2.5
V5440
19
3
V5805
15
2
V5280
19
2
60885
14
4.5
60660
25.5
1.5
62355
33.5
3
KS50
12
3
KS100.3
15
2.5
SK16
25.5
1.5
SK52
19
2
L30
21
3
LZ50
24
3
6155
14
4.5
6601
14
5
6176
24
4.5
6320
30
1.5
ASSMAN
AAVID
AUSTERLITZ
FISCHER
SGE BOSARI
THERMALLOY
Height (mm)
Rth (°C/W)
Information furnished is believed to be accurate and reliable. However, SGS-THOMSON Microelectronics assumes no responsibility for the
consequences of use of such information nor for any infringement of patents or other rights of third parties which may result from its use. No
license is granted by implication or otherwise under any patent or patent rights of SGS-THOMSON Microelectronics. Specification mentioned
in this publication are subject to change without notice. This publication supersedes and replaces all information previously supplied.
SGS-THOMSON Microelectronics products are not authorized for use as critical components in life support devices or systems without express
written approval of SGS-THOMSON Microelectronics.
 1994 SGS-THOMSON Microelectronics – All Rights Reserved
SGS-THOMSON Microelectronics GROUP OF COMPANIES
Australia - Brazil - China - France - Germany - Hong Kong - Italy - Japan - Korea - Malaysia - Malta - Morocco - The Netherlands Singapore - Spain - Sweden - Switzerland - Taiwan - Thailand - United Kingdom - U.S.A.
7/7