MA-COM H-18

8 kV Kilovac H-18
Features:
Make & Break Load Switching
• Smallest DPDT high voltage relay
• Vacuum dielectric for power switching low
current loads
• 8 kV rating; carries 2 Amps at 32 MHz
• Tungsten contacts for power switching low
current loads
• Meets requirements of MIL-R-83725
Features:
PRODUCT SPECIFICATIONS
Units
COIL DATA
H-18
H-18
Contact Arrangement ..........................................................
DPDT
Nominal, Volts dc
12
26.5
Contact Form ........................................................................
2C
Pickup, Volts dc, Maximum
8
16
80
10
Drop-Out, Volts dc
.5 - 5
1 - 10
5 - 50
60
250
3500
Part Number
Test Voltage (dc or 60Hz) ...................................................
kV Peak
Rated Operating Voltage
kV Peak
Coil Resistance (Ohms ±10%)
dc or 60 Hz .....................................................................
8
2.5 MHz ...........................................................................
5
16 MHz ............................................................................
3
32 MHz ............................................................................
Continuous Carry Current , Maximum
2
Amps
dc or 60 Hz .....................................................................
10
2.5 MHz ...........................................................................
7
16 MHz ............................................................................
3
32 MHz ............................................................................
2
Coil Hi-Pot (V RMS, 60 Hz) ...........................................
500
Contact Capacitance
pF
Between Open Contacts .................................................
0.8
Open Contacts to Ground ..............................................
1.5
Contact Resistance, Maximum ...........................................
ohms
0.02
Operate Time, Maximum .....................................................
ms
15
Release Time, Maximum .....................................................
ms
15
Shock, 11 ms 1/2 Sine ........................................................
G's Peak
30
Vibration, 10 G’s Peak .........................................................
Hz
55-500
C
-55 to +125
Operating Ambient Temperature Range ............................
o
Mechanical Life (Operations x 106) ....................................
cycles
1
Weight, Nominal (oz) ..........................................................
oz.
2.5
37
115
PART NUMBER SELECTION
Sample Part No.
Model
H-18
Coil Voltage
Blank = 26.5 Vdc
/12Vdc = 12 Vdc
/115Vdc = 115 Vdc
H-18
/12Vdc
CII Technologies / P.O. Box 4422 / Santa Barbara, CA 93140 / ph 805.684.4560 / fax 805.684.9679 / e-mail [email protected] / website www.ciitech.com