ETC H12D4825DE

Dual Relays
25-40Amp • 120/240, 480 Vac • AC OUTPUT
• Zero Voltage and Random
Turn-On Swi tching
• SCR Output
• Industry Standard Package
• Panel M ount
MODEL NUMBERS
OUTPUT SPECIFICATIONS ➀
D2425D
D2425DE
D2440D
D2440DE
Two totally independent AC output
relays come in a single standard panelmount package. Utilizing an AC switch
output with internal snubber, relays
provide greater protection against false
triggering. Model choices include zerovoltage or random turn-on (phase controllable) switching.
Manufactured in Crydom's ISO 9001
Certified facility for optimum product
performance and reliability.
H12D4825D
H12D4825DE
H12D4840D
H12D4840DE
Operating Voltage (47-63 Hz) [Vrms]
24-280
24-280
48-530
48-530
Load Current Range ➂ [Arms]
.15-25
.15-40
.15-25
.15-40
Transient Overvoltage [Vpk]
600
600
1200
1200
Max. Surge Current, (16.6ms) [Apk]
250
625
250
625
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.6
1.6
1.6
1.6
1.02
.63
1.02
.63
260
1620
260
1620
10
10
10
10
500
500
500
500
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
0.5
0.5
0.5
0.5
Thermal Resistance Junction to Case (RθJC) [ûC/W]
➀
Maximum I2 t for Fusing, (8.3 msec.) [A2sec]
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]➁
Max. Turn-On Time
➃
Max. Turn-Off Time
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS ➀
D24XXD
H12D48XXD
E-SUFFIX
Control Voltage Range
4-15Vdc
4-15Vdc
15-32Vdc
Max. Turn-On Voltage
4.0 Vdc
4.0 Vdc
15 Vdc
Min. Turn-Off Voltage
1.0 Vdc
1.0 Vdc
1.0 Vdc
300 Ohms
240 Ohms
13mA
13mA
Nominal Input Impedance
Typical Input Current @ 5Vdc (@ 24Vdc for E-Suffix)
15mA
© 2003 CRYDOM CORP, Specifications subject to change without notice.
GENERAL NOTES
➀ All parameters at 25˚C and per section unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ Heat sinking required, for derating curves see page 2.
➃ Turn-on time for random turn-on (-10) versions is 0.1 msec.
FastFax Document No. 165
DUAL.
Rev. 111203
PAGE 1 OF 2
1500 Ohms
Crydom Heat Sinks offer excellent thermal
management and are perfectly matched to the
load current ratings of Crydom panel mount
relays. Request Crydom's Heat Sink specification sheet for all the details.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: [email protected] WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: [email protected].
GERMANY: +49 (0)180 3000 506
Dual Relays
25-40Amp • 120/240, 480 Vac • AC OUTPUT
GENERAL SPECIFICATIONS
Dielectric Strength50/60Hz Input/Output/Base
4000 Vrms
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
10 pF
Max. Capacitance Input/Output
Ambient Operating Temperature Range
-40 to 80˚C
Ambient Storage Temperature Range
-40 to 125˚C
M ECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (86.5g)
Encapsulation:
Thermally Conductive Epoxy
Terminals:
.25' Fastons, .025' Square Pins
120/240 V MO DEL
AVAILABLE OPTIONS
-10
1.17
(29.7)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
Random Turn-On,
Phase Controllable
Example: D2440D-10
1.00
(25.4)
A2
15-32Vdc Control
Example: H12D4840DE
B1 B2
120/24OV - 20A
120/24OV - 20A
120/24OV - 20A
2.30
(58.4)
2.30 1.87
(58.4) (47.5)
CONTROL A
1.87 1.60
(47.5) (40.6)
CONTROL B
4-15VDC ±
H
A1 A2
B2
A1
MOUNTING HOLE/SLOT
.017 (4.3) DIA.
2 PLC'S
.250 X .032 FASTON
TERMINAL
(4 PLACES)
.55
(14.0)
B1
120/24OV - 20A
E
480V MO DEL
FASTON
TERMINAL
.250 X .032
(4 PLACES)
.15
(3.8)
± 4-15VDC
CONTROL
Heat Transfer Pad (Attached)
Example: D2440DH
-
.50
(12.7)
PIN .025 SQ.
.100 CENTERS
4 PLACES
A
1.80
(45.7)
B
+
-
.77
(19.6)
.85
(21.6)
1.31
(33.2)
.45
(11.4)
CONTROL
+
.187 X .032
FASTON
TERMINAL
(4 PLACES)
1.37
(34.8)
1.80
.85
(21.6)
1.31
(33.2)
All dimensions are in inches (millimeters)
85
25A LIMIT
(1 SECTION)
2.0˚C/W
1.0˚C/W
95
5.0˚C/W
105
20
0
100
40A
80A LIMIT
(2 SECTIONS)
80
60
0.5˚C/W
40A LIMIT
(1 SECTION)
40
90
95
1.0˚C/W
100
2.0˚C/W
20
105
5.0˚C/W
Max Allowable Base Temp. [˚C]
40
Power Dissipation [W]
Power Dissipation [W]
75
0.5˚C/W
Max Allowable Base Temp. [˚C]
CURRENT DERATING CURVES
25A
50A LIMIT
(2 SECTIONS)
0
10
20
30
40
50
10
20
Load Current [Arms]
30
40
50
60
70
Max Ambient Temp. [˚C]
80
20
40
480Vrms
120/240Vrms
LOAD A
A2
B1
A1
B2
LOAD B
60
80 100 10
Load Current [Arms]
FastFax Document No. 165
DUAL.
Rev. 111203
PAGE 2 OF 2
40
50
LOAD B
60
70
80
480Vrms
120/240Vrms
A1 A2
B1 B2
480V Model
W IRING DIAGRAM S
APPROVALS
UL E116949
CSA LR81689 (240V only)
VDE 5902 UG
30
Max Ambient Temp. [˚C]
LOAD A
240V Model
-- B CONTROL
+ B CONTROL
-- A CONTROL
+ A CONTROL
20
-- A CONTROL
+ A CONTROL
+ B CONTROL
-- B CONTROL
©2003 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: [email protected] WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: [email protected].
GERMANY: +49 (0)180 3000 506