Dual Relays 25-40Amp • 120/240, 480 Vac • AC OUTPUT • Zero Voltage and Random Turn-On Swi tching • SCR Output • Industry Standard Package • Panel M ount MODEL NUMBERS OUTPUT SPECIFICATIONS ➀ D2425D D2425DE D2440D D2440DE Two totally independent AC output relays come in a single standard panelmount package. Utilizing an AC switch output with internal snubber, relays provide greater protection against false triggering. Model choices include zerovoltage or random turn-on (phase controllable) switching. Manufactured in Crydom's ISO 9001 Certified facility for optimum product performance and reliability. H12D4825D H12D4825DE H12D4840D H12D4840DE Operating Voltage (47-63 Hz) [Vrms] 24-280 24-280 48-530 48-530 Load Current Range ➂ [Arms] .15-25 .15-40 .15-25 .15-40 Transient Overvoltage [Vpk] 600 600 1200 1200 Max. Surge Current, (16.6ms) [Apk] 250 625 250 625 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6 1.6 1.02 .63 1.02 .63 260 1620 260 1620 10 10 10 10 500 500 500 500 1/2 cycle 1/2 cycle 1/2 cycle 1/2 cycle 1/2 cycle 1/2 cycle 1/2 cycle 1/2 cycle 0.5 0.5 0.5 0.5 Thermal Resistance Junction to Case (RθJC) [ûC/W] ➀ Maximum I2 t for Fusing, (8.3 msec.) [A2sec] Max. Off-State Leakage Current @ Rated Voltage [mArms] Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]➁ Max. Turn-On Time ➃ Max. Turn-Off Time Power Factor (Min.) with Max. Load INPUT SPECIFICATIONS ➀ D24XXD H12D48XXD E-SUFFIX Control Voltage Range 4-15Vdc 4-15Vdc 15-32Vdc Max. Turn-On Voltage 4.0 Vdc 4.0 Vdc 15 Vdc Min. Turn-Off Voltage 1.0 Vdc 1.0 Vdc 1.0 Vdc 300 Ohms 240 Ohms 13mA 13mA Nominal Input Impedance Typical Input Current @ 5Vdc (@ 24Vdc for E-Suffix) 15mA © 2003 CRYDOM CORP, Specifications subject to change without notice. GENERAL NOTES ➀ All parameters at 25˚C and per section unless otherwise specified. ➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 ➂ Heat sinking required, for derating curves see page 2. ➃ Turn-on time for random turn-on (-10) versions is 0.1 msec. FastFax Document No. 165 DUAL. Rev. 111203 PAGE 1 OF 2 1500 Ohms Crydom Heat Sinks offer excellent thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request Crydom's Heat Sink specification sheet for all the details. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: [email protected] WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: [email protected]. GERMANY: +49 (0)180 3000 506 Dual Relays 25-40Amp • 120/240, 480 Vac • AC OUTPUT GENERAL SPECIFICATIONS Dielectric Strength50/60Hz Input/Output/Base 4000 Vrms 109 Ohm Insulation Resistance (Min.) @ 500 Vdc 10 pF Max. Capacitance Input/Output Ambient Operating Temperature Range -40 to 80˚C Ambient Storage Temperature Range -40 to 125˚C M ECHANICAL SPECIFICATIONS Weight: (typical) 3.0 oz. (86.5g) Encapsulation: Thermally Conductive Epoxy Terminals: .25' Fastons, .025' Square Pins 120/240 V MO DEL AVAILABLE OPTIONS -10 1.17 (29.7) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. Random Turn-On, Phase Controllable Example: D2440D-10 1.00 (25.4) A2 15-32Vdc Control Example: H12D4840DE B1 B2 120/24OV - 20A 120/24OV - 20A 120/24OV - 20A 2.30 (58.4) 2.30 1.87 (58.4) (47.5) CONTROL A 1.87 1.60 (47.5) (40.6) CONTROL B 4-15VDC ± H A1 A2 B2 A1 MOUNTING HOLE/SLOT .017 (4.3) DIA. 2 PLC'S .250 X .032 FASTON TERMINAL (4 PLACES) .55 (14.0) B1 120/24OV - 20A E 480V MO DEL FASTON TERMINAL .250 X .032 (4 PLACES) .15 (3.8) ± 4-15VDC CONTROL Heat Transfer Pad (Attached) Example: D2440DH - .50 (12.7) PIN .025 SQ. .100 CENTERS 4 PLACES A 1.80 (45.7) B + - .77 (19.6) .85 (21.6) 1.31 (33.2) .45 (11.4) CONTROL + .187 X .032 FASTON TERMINAL (4 PLACES) 1.37 (34.8) 1.80 .85 (21.6) 1.31 (33.2) All dimensions are in inches (millimeters) 85 25A LIMIT (1 SECTION) 2.0˚C/W 1.0˚C/W 95 5.0˚C/W 105 20 0 100 40A 80A LIMIT (2 SECTIONS) 80 60 0.5˚C/W 40A LIMIT (1 SECTION) 40 90 95 1.0˚C/W 100 2.0˚C/W 20 105 5.0˚C/W Max Allowable Base Temp. [˚C] 40 Power Dissipation [W] Power Dissipation [W] 75 0.5˚C/W Max Allowable Base Temp. [˚C] CURRENT DERATING CURVES 25A 50A LIMIT (2 SECTIONS) 0 10 20 30 40 50 10 20 Load Current [Arms] 30 40 50 60 70 Max Ambient Temp. [˚C] 80 20 40 480Vrms 120/240Vrms LOAD A A2 B1 A1 B2 LOAD B 60 80 100 10 Load Current [Arms] FastFax Document No. 165 DUAL. Rev. 111203 PAGE 2 OF 2 40 50 LOAD B 60 70 80 480Vrms 120/240Vrms A1 A2 B1 B2 480V Model W IRING DIAGRAM S APPROVALS UL E116949 CSA LR81689 (240V only) VDE 5902 UG 30 Max Ambient Temp. [˚C] LOAD A 240V Model -- B CONTROL + B CONTROL -- A CONTROL + A CONTROL 20 -- A CONTROL + A CONTROL + B CONTROL -- B CONTROL ©2003 CRYDOM CORP, Specifications subject to change without notice. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: [email protected] WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: [email protected]. GERMANY: +49 (0)180 3000 506