OMRON H7CX

Multifunction Preset Counter
H7CX
Counters
• Highly visible display with backlit negative transmissive LCD.
• Programmable PV color to visually alert when output status
changes (screw terminal block models).
• Intuitive setting enabled using ergonomic up/down digit keys (4digit models) and DIP switch.
• Configurable as 1-stage counter, 2-stage counter, total and preset counter, batch counter, dual counter, or tachometer. (Configurability varies with model.)
• PNP/NPN switchable input.
• Finger-safe terminals (screw terminal block models).
• Meets a variety of mounting requirements:
Screw terminal block models, and pin-style terminal models.
• NEMA4/IP66 compliance.
• Six-language instruction manual.
Contents
Model Number Structure.............................................................. C-88
Ordering Information.................................................................... C-88
Specifications............................................................................... C-89
Connections................................................................................. C-93
Nomenclature .............................................................................. C-98
Dimensions .................................................................................. C-99
Precautions.................................................................................. C-103
Operating Procedures.................................................................. C-106
Setting Procedure Guide ....................................................... C-106
Operating Procedures (Counter Function) ............................ C-107
Operating Procedures (Tachometer Function) ...................... C-118
Operation in Configuration Selection Mode........................... C-124
Additional Information .................................................................. C-125
Multifunction Preset Counter
H7CX
C-87
Model Number Structure
■ Model Number Legend
H7CX-A@@@@@@
1 2 3 4 5 6
4. Output type
None: Contact output or contact and transistor in combination
S:
Transistor output
5. Supply voltage/external power supply
None: 100 to 240 VAC at 50/60 Hz with 12 VDC power supply
D:
12 to 24 VDC without external power supply
D1: 12 to 24 VDC or 24 VAC at 50/60 Hz with 12 VDC power
supply
6. Case color
None: Black
G:
Light gray (Munsell 5Y7/1): Produced upon request.
1. External connection
None: Screw terminals
11: 11-pin socket
2. No. of digits
None: 6 digits
4:
4 digits
3. Stage setting
None: 1-stage setting
U:
Factory-set to 1-stage setting
W:
Factory-set to 2-stage setting
Ordering Information
■ List of Models
Supported configurations
Sensor
power
supply
12 VDC
None
Output type
• 1-stage counter
• 1-stage counter with total counter
Supply voltage
• 1-stage counter
• 2-stage counter
• 1-stage counter with total
counter
• 1-stage counter with batch
counter
• Dual counter (addition/subtraction)
• Tachometer
11-pin socket
Screw terminal
1-stage
Contact output
1-stage
(See note.)
2-stage
6 digits
4 digits
6 digits
4 digits
6 digits
6 digits
4 digits
H7CX-A11@
H7CX-A114@
H7CX-A@
H7CX-A4@
H7CX-AU@
H7CX-AW@
H7CX-A4W@
100 to 240 VAC
H7CX-A11
H7CX-A114
H7CX-A
H7CX-A4
---
H7CX-AW
H7CX-A4W
12 to 24 VDC/
24 VAC
H7CX-A11D1
H7CX-A114D1
---
---
---
H7CX-AWD1
---
Contact and
transistor output
100 to 240 VAC
---
---
---
---
H7CX-AU
---
---
12 to 24 VDC/
24 VAC
---
---
---
---
H7CX-AUD1
---
---
Transistor output
100 to 240 VAC
H7CX-A11S
H7CX-A114S
H7CX-AS
H7CX-A4S
---
H7CX-AWS
---
12 to 24 VDC/
24 VAC
H7CX-A11SD1
---
---
---
H7CX-AUSD1
H7CX-AWSD1
---
12 to 24 VDC
---
---
H7CX-AD
H7CX-A4D
---
---
---
---
---
H7CX-ASD
H7CX-A4SD
---
H7CX-AWSD
H7CX-A4WSD
Contact output
Transistor output
Note: Can be used as a 2-stage counter. In this case, each output can be flexibly allocated to either stage 1 or 2.
■ Accessories (Order Separately)
Name
Flush Mounting Adapter (See note 1.)
Waterproof Packing (See note 1.)
Models
Y92F-30
Y92S-29
Track Mounting/Front Connecting
Socket
11-pin
11-pin, finger-safe type
P2CF-11-E
Back Connecting Socket
11-pin
P3GA-11
11-pin, finger-safe type
Hard Cover
Mounting Track
P2CF-11
P3GA-11 with Y92A-48G (See note 2.)
Y92A-48
Soft Cover
Y92A-48F1
50 cm (l) × 7.3 mm (t)
PFP-50N
1 m (l) × 7.3 mm (t)
PFP-100N
1 m (l) × 16 mm (t)
PFP-100N2
End Plate
PFP-M
Spacer
PFP-S
Note: 1. Supplied with screw-terminal models (i.e., excluding H7CX-A11@/-A114@ models).
2. Y92A-48G is a finger-safe terminal cover attached to the P3GA-11 Socket.
C-88
• 1-stage counter
• 2-stage counter
• 1-stage counter
with total counter
• 1-stage counter
with batch counter
• Dual counter (addition only)
Multifunction Preset Counter H7CX
Specifications
■ Ratings
H7CX-A4@
H7CX-A@
Preset counter
Supported
configurations
1-stage counter, 1-stage counter with total counter (selectable)
Rated supply voltage
(See note 1.)
100 to 240 VAC (50/60 Hz), 12 to 24 VDC
H7CX-A114@
H7CX-A11@
Counters
Item
Classification
100 to 240 VAC (50/60 Hz)
24 VAC (50/60 Hz)/12 to 24 VDC
Operating voltage range 85% to 110% of rated supply voltage (90% to 110% at 12 VDC)
Power consumption
Approx. 9.2 VA at 264 VAC
Approx. 7.2 VA at 26.4 VAC
Approx. 3.7 W at 12 VDC
Mounting method
Flush mounting
Flush mounting, surface mounting, or DIN track mounting
External connections
Screw terminals
11-pin socket
Terminal screw
tightening torque
0.5 N·m max.
---
Display
7-segment, negative transmissive LCD;
PV
11.5-mm-high characters, red or 9-mm-high characters, red or
green (programmable)
green (programmable)
SV
6-mm-high characters, green
6 digits (−99,999 to 999,999)
SV range: −99,999 to 999,999
(See note 2.) or 0 to 999,999
11.5-mm-high characters, red
9-mm-high characters, red
4 digits (−999 to 9,999)
SV range: 0 to 9,999
6 digits (−99,999 to 999,999)
SV range: −99,999 to 999,999
(See note 2.) or 0 to 999,999
Digits
4 digits (−999 to 9,999)
SV range: 0 to 9,999
Max. counting speed
30 Hz or 5 kHz (selectable, ON/OFF ratio 1:1), common setting for CP1 and CP2
Input modes
Increment, decrement, command, individual, and quadrature
Input signals
CP1, CP2, reset, and total reset
Input method
No-voltage input/voltage input (switchable)
No-voltage input
ON impedance: 1 kΩ max. (Leakage current: 5 to 20 mA at 0 Ω)
ON residual voltage: 3 V max.
OFF impedance: 100 kΩ min.
Voltage input
High (logic) level: 4.5 to 30 VDC
Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ)
Reset input
Minimum reset input signal width: 1 or 20 ms (selectable), common setting for all inputs
Reset system
External, manual, and automatic reset (internal according to C, R, P, and Q mode operation)
Output modes
N, F, C, R, K-1, P, Q, A
One-shot output time
0.01 to 99.99 s
Output type
Contact type: SPDT
Transistor type: 1 transistor
Control output
Contact output:
3 A at 250 VAC/30 VDC, resistive load (cosφ=1)
Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value)
Transistor output:
NPN open collector, 100 mA at 30 VDC
Residual voltage: 1.5 VDC max. (approx. 1 V)
Leakage current: 0.1 mA max.
N, F, C, R, K-1, P, Q, A,
K-2, D, L
N, F, C, R, K-1, P, Q, A
N, F, C, R, K-1, P, Q, A,
K-2, D, L
NEMA B300 Pilot Duty, 1/4 HP 3-A resistive load at 120 VAC, 1/3 HP 3-A resistive load at 240 VAC
External power supply
12 VDC (±10%), 100 mA (except for H7CX-A@D models)
Refer to Precautions for details.
Key protection
Yes
Prescaling function
Yes (0.001 to 9.999)
Decimal point
adjustment
Yes (rightmost 3 digits)
Sensor waiting time
250 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)
Memory backup
EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.
Ambient temperature
Operating:
Storage:
Ambient humidity
25% to 85%
Case color
Black (N1.5), light gray (Munsell 5Y7/1, produced upon request)
Attachments
Waterproof packing, flush mounting adapter
Yes (0.001 to 99.999)
Yes (0.001 to 9.999)
Yes (0.001 to 99.999)
−10 to 55°C (−10 to 50°C if counters are mounted side by side) (with no icing or condensation)
−25 to 65°C (with no icing or condensation)
None
Note: 1. Permissible ripple: 20% (p-p) max.
2. Only when the following modes are selected.
Input mode: command, individual, or quadrature; output mode: K-2, D, or L
Multifunction Preset Counter
H7CX
C-89
■ Ratings (contd.)
Item
H7CX-A4W@
H7CX-AW@
H7CX-AU@
Classification
Preset counter
Supported configurations
1-stage counter, 2-stage counter, 1-stage 1-stage counter, 2-stage counter, 1-stage counter with total counter, 1-stage counter with batch
counter with total counter, 1-stage counter counter, dual counter (addition/subtraction), tachometer (selectable)
with batch counter, dual counter (addition
only) (selectable)
Rated supply voltage (See note 1.)
100 to 240 VAC (50/60 Hz),
12 to 24 VDC
Operating voltage range
85% to 110% of rated supply voltage (90% to 110% at 12 VDC)
Power consumption
Approx. 9.2 VA at 264 VAC
Approx. 7.2 VA at 26.4 VAC
Approx. 3.7 W at 12 VDC
Mounting method
Flush mounting
External connections
Screw terminals
Terminal screw tightening torque
0.5 N·m max.
Display
7-segment, negative transmissive LCD
PV
11.5-mm-high characters, red or green
(programmable)
SV
6-mm-high characters, green
Preset counter/tachometer
100 to 240 VAC (50/60 Hz),
24 VAC (50/60 Hz)/12 to 24 VDC,
12 to 24 VDC
9-mm-high characters, red or green (programmable)
Digits
4 digits (−999 to 9,999)
SV range: 0 to 9,999
Input signals
CP1, CP2, reset 1, and reset 2
Input method
No-voltage input/voltage input (switchable)
No-voltage input
ON impedance: 1 kΩ max. (Leakage current: 5 to 20 mA at 0 Ω)
ON residual voltage: 3 V max.
OFF impedance: 100 kΩ min.
Voltage input
High (logic) level: 4.5 to 30 VDC
Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ)
Counter
Tachometer
100 to 240 VAC (50/60 Hz),
24 VAC (50/60 Hz)/12 to 24 VDC
6 digits (−99,999 to 999,999 or 0 to 999,999 when using as Tachometer)
SV range: −99,999 to 999,999 (See note 2.) or 0 to 999,999
Max. counting speed
30 Hz or 5 kHz (selectable, ON/OFF ratio 1:1), common setting for CP1 and CP2
Input mode
Increment, decrement, command, individual, and quadrature
Reset input
Minimum reset input signal width: 1 or 20 ms (selectable), common setting for all inputs
Reset system
External, manual, and automatic reset (internal according to C, R, P, and Q mode operation)
Output modes
N, F, C, R, K-1, P, Q, A
One-shot output time
0.01 to 99.99 s
Pulse measurement
method
---
Max. counting speed
---
30 Hz or 10 kHz (selectable)
Measuring ranges
---
30 Hz: 0.01 to 30.00 Hz
10 kHz: 0.01 Hz to 10 kHz
N, F, C, R, K-1, P, Q, A, K-2, D, L, H
Periodic measurement (Sampling period: 200 ms)
Measuring accuracy
---
±0.1% FS ±1 digit max. (at 23 ±5°C)
Output modes
---
HI-LO, AREA, HI-HI, LO-LO
Auto-zero time
---
0.1 to 99.9 s
Startup time
---
0.0 to 99.9 s
Average processing
---
OFF/2/4/8 times
Output type
H7CX-A4W/-AW/-AWD1: SPDT (OUT2) and SPST-NO (OUT1)
H7CX-A4WSD/-AWS/-AWSD/-AWSD1: 2 transistors
Control output
Contact output:
3 A at 250 VAC/30 VDC, resistive load (cosφ=1)
Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value)
Transistor output:
NPN open collector, 100 mA at 30 VDC
Residual voltage: 1.5 VDC max. (approx. 1 V)
Leakage current: 0.1 mA max.
H7CX-AU/-AUD1: SPDT and 1 transistor
H7CX-AUSD1: 2 transistors
(Output allocation possible)
NEMA B300 Pilot Duty, 1/4 HP 3-A resistive load at 120 VAC, 1/3 HP 3-A resistive load at 240 VAC
External power supply
12 VDC (±10%) 100 mA (except for H7CX-A@D models)
Refer to Precautions for details.
Key protection
Yes
Prescaling function
Yes (0.001 to 9.999)
Decimal point adjustment
Yes (rightmost 3 digits)
Sensor waiting time
250 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)
Memory backup
EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.
Ambient temperature
Operating:
Storage:
Ambient humidity
25% to 85%
Case color
Black (N1.5), light gray (Munsell 5Y7/1, produced upon request)
Attachments
Waterproof packing, flush mounting adapt- Waterproof packing, flush mounting adapter, labels for counter/tachometer DIP switch settings
er
Yes (0.001 to 99.999)
−10 to 55°C (−10 to 50°C if counters are mounted side by side) (with no icing or condensation)
−25 to 65°C (with no icing or condensation)
Note: 1. Permissible ripple: 20% (p-p) max.
2. Only when the following modes are selected.
- Input mode: command, individual, or quadrature; output mode: K-2, D, L, or H
- Dual count calculating mode: SUB; output mode: K-2, D, L, or H in dual counter operation
C-90
Multifunction Preset Counter H7CX
■ Characteristics
H7CX
100 MΩ min. (at 500 VDC) between current-carrying terminal and exposed non-current-carrying metal parts, and between non-continuous contacts
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-carrying metal parts
2,000 VAC (for 100 to 240 VAC), 50/60 Hz for 1 min between power supply and input circuit (1,000 VAC for 24 VAC/
12 to 24 VDC)
1,000 VAC (for H7CX-@SD/-@SD1), 50/60 Hz for 1 min between control output, power supply, and input circuit
(2,000 VAC for models other than H7CX-@SD/-@SD1)
1,000 VAC, 50/60 Hz for 1 min between non-continuous contacts
Impulse withstand
voltage
3 kV (between power terminals) for 100 to 240 VAC, 1 kV for 24 VAC/12 to 24 VDC and 12 to 24 VDC
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 240 VAC,
1.5 kV for 24 VAC/12 to 24 VDC and 12 to 24 VDC
Noise immunity
±1.5 kV (between power terminals) for 100 to 240 VAC and 24 VAC/12 to 24 VDC, ±480 V for 12 to 24 VDC
±600 V (between input terminals)
Square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)
Static immunity
Destruction: 15 kV
Malfunction: 8 kV
Vibration resistance
Destruction: 10 to 55 Hz with 0.75-mm single amplitude, four cycles each in three directions (8 minutes per cycle)
Malfunction: 10 to 55 Hz with 0.35-mm single amplitude, four cycles each in three directions (8 minutes per cycle)
Shock resistance
Destruction: 294 m/s2 each in three directions
Malfunction: 98 m/s2 each in three directions
Life expectancy
Mechanical: 10,000,000 operations min.
Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load)
See Life-test Curve on page 92.
Approved safety
standards
(See note 1.)
UL508/Listing, CSA C22.2 No. 14, conforms to EN61010-1 (Pollution degree 2/overvoltage category II)
Conforms to VDE0106/P100 (finger protection).
EMC
(EMI)
Emission Enclosure:
Emission AC mains:
(EMS)
Immunity ESD:
Degree of protection
Panel surface: IP66 and NEMA Type 4 (indoors) (See note 2.)
Weight
Approx. 140 g
EN61326
EN55011 Group 1 class A
EN55011 Group 1 class A
EN61326
EN61000-4-2:
4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference:
EN61000-4-3:
10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3);
10 V/m (Pulse-modulated, 900 MHz ±5 MHz) (level 3)
Immunity Conducted Disturbance: EN61000-4-6:
10 V (0.15 to 80 MHz) (level 3)
Immunity Burst:
EN61000-4-4:
2 kV power-line (level 3);
1 kV I/O signal-line (level 4)
Immunity Surge:
EN61000-4-5:
1 kV line to lines (power and output lines) (level 2);
2 kV line to ground (power and output lines) (level 3)
Immunity Voltage Dip/Interruption EN61000-4-11: 0.5 cycle, 100% (rated voltage)
Note: 1. To meet UL listing requirements with the H7CX-A11@ models, an OMRON P2CF-11-@ or P3GA-11 Socket must be mounted on the
H7CX. Otherwise, H7CX-A11@ models are considered to meet UL508 recognition requirements.
2. A waterproof packing is necessary to ensure IP66 waterproofing between the H7CX and installation panel.
Multifunction Preset Counter
H7CX
C-91
Counters
item
Insulation resistance
■ Life-test Curve (Reference Values)
Resistive Load
Inductive Load
1,000
No. of operations (×103)
No. of operations (×103)
1,000
700
500
300
30 VDC (cosφ=1)
250 VAC (cosφ=1)
700
500
300
30 VDC (L/R=7 ms)
100
100
70
70
250 VAC cosφ=0.4
50
50
0
1
2
3
0
4
1
2
Load current (A)
3
4
Load current (A)
Reference: A current of 0.15 A max. can be switched at 125 VDC (cosφ=1) and current of 0.1 A max. can be switched if L/R=7 ms. In both cases,
a life of 100,000 operations can be expected. The minimum applicable load is 10 mA at 5 VDC (failure level: P).
■ Inrush Current (Reference Values)
Model
H7CX-A11/-AW
Voltage
Applied voltage Inrush current (peak value)
0.7 ms
H7CX-A11D1/-AWD1 24 VAC/12 to 24 VDC 26.4 VAC
10.4 A
1.2 ms
H7CX-AD
6.0 A
1.2 ms
12 to 24 VDC
264 VAC
Time
5.8 A
C-92
100 to 240 VAC
26.4 VDC
Multifunction Preset Counter H7CX
Connections
■ Block Diagram
(Basic
insulation)
Output circuit
(Basic
insulation)
Power supply
circuit
Counters
(See note.)
Display circuit
Internal control
circuit
Input circuit
Key switch
circuit
Note: All models except for H7CX-@D (models with 12 to 24-VDC power supplies) have basic insulation.
■ I/O Functions
Using as a Counter
Inputs
Outputs
CP1, CP2
• In general (except for dual counter mode)
Reads counting signals
Increment, decrement, command, individual, and quadrature inputs accepted.
• When used as a dual counter
Reads CP1 count signals with CP1 input and CP2 count signals with CP2 input.
Increment signals can be input.
Reset or Reset 1
• In general (except for dual counter mode)
Resets present value and outputs (OUT2 when using the batch counter). (See note 1.)
Counting cannot be performed during reset/reset 1 input.
The reset indicator is lit during reset input.
• When used as a dual counter
Resets the CP1 present value (to 0).
Counting for CP1 input cannot be performed during reset 1 input.
The reset indicator is lit during reset 1 input.
Total Reset or
Reset 2
(See note 2.)
• When used as a 1-stage/2-stage counter
Does not operate (Not used).
• When used as a total and preset counter
Resets the total count value.
Holds the total count value at 0 during total reset input.
• When used as a batch counter
Resets the batch count value and batch output (OUT1).
Holds the batch count value at 0 during reset 2 input.
• When used as a dual counter
Resets the CP2 present value.
Counting for CP2 input cannot be performed during reset 2 input.
OUT1, OUT2
Outputs take place according to designated output mode when corresponding preset is reached.
Note: 1. In increment mode or increment/decrement mode, the present value returns to 0; in decrement mode, the present value returns to the
set value with 1-stage models, and returns to set value 2 with 2-stage models.
2. The reset indicator will not be lit when the total reset or reset 2 input is ON.
Using as a Tachometer
Inputs
Outputs
CP1, CP2
Reads counting signals. (CP2 input is not used.)
Reset 1, Reset 2
Holds the measurement value and outputs. (Reset 2 input is not used.)
The reset indicator is lit during hold.
OUT1, OUT2
Outputs signals according to the specified output mode when a set value is reached.
Multifunction Preset Counter
H7CX
C-93
■ Terminal Arrangement
Confirm that the power supply meets specifications before use.
CP1
6
Total reset
10
CP2
CP1
Total reset
CP2
Reset
0V
Reset
H7CX-AD/-A4D
1-stage Contact Output
H7CX-A/-A4
1-stage Contact Output
7
8
9
10
0V
6
(−)
7
8
9
Sensor, etc.
Unused
(+) 12 VDC
11
Unused
12
Unused
13
11
5
1
Unused
Unused
12
13
External power
supply
1
2
3
4
2
3
4
5
OUT
OUT
(−)
(+)
Note: Terminals 1 and 6 are connected internally.
Total reset
6
CP1
10
CP2
0V
Reset
CP1
H7CX-ASD/-A4SD
1-stage Transistor Output
Total reset
CP2
Reset
H7CX-AS/-A4S
1-stage Transistor Output
7
8
9
10
0V
6
(−)
7
8
9
Sensor, etc.
Unused
(+) 12 VDC
11
Unused
12
Unused
13
11
5
1
Unused
Unused
12
13
External power
supply
1
2
3
4
2
3
4
OUT
5
OUT
(+)
(−)
Note: Terminals 1 and 6 are connected internally.
H7CX-A11/-A114/-A11D1/-A114D1
1-stage Contact Output
H7CX-A11S/-A114S/-A11SD1
1-stage Transistor Output
Reset
Reset
CP1
CP1
Internal circuit
CP2
0V
(−)
(+)
4
8
9
10
1 11
4
0V
(−)
(+)
8
3
2
Sensor, etc.
12 VDC
1 11
9
10
12 VDC
External power supply
External power supply
OUT
OUT
(−)
(+)
Note: Do not connect unused terminals as relay terminals.
C-94
Internal circuit
5 6 7
Total reset
3
2
Sensor, etc.
CP2
5 6 7
Total reset
Multifunction Preset Counter H7CX
(−)
(+)
10
6
(−)
8
9
10
Sensor, etc.
Sensor, etc.
(+)
(+) 12 VDC
External power
supply
7
0V
11
12
13
Counters
(−)
Reset 2
9
CP1
8
CP2
CP1
Reset 2
7
0V
6
Reset 1
CP2
H7CX-AWS/-AWSD1
2-stage Transistor Output
Reset 1
H7CX-AW/-A4W/-AWD1
2-stage Contact Output
12 VDC
11
OUT1
12
13
OUT1
External power
supply
1
2
3
4
1
5
2
3
5
(−)
(+)
9
10
Reset 2
8
CP1
CP1
Reset 2
7
CP2
CP2
H7CX-AUSD1
1 or 2-stage Transistor Output
Reset 1
H7CX-AWSD/-A4WSD
2-stage Transistor Output
(+)
Reset 1
(−)
4
OUT2
OUT2
7
8
9
10
0V
0V
6
6
(−)
Sensor, etc.
Unused
(+)
11
12
13
12 VDC
11
OUT1
12
13
OUT1 or 2
External power
supply
1
2
3
4
5
1
2
3
(−)
4
5
OUT 1 or 2
OUT2
(+)
Note: 1. Terminals 1 and 6 are connected internally.
2. Do not connect unused terminals as relay terminals.
(−)
(+)
Note: Each output can be flexibly allocated to
either stage 1 or 2 in function selection
mode.
Reset 1
CP2
CP1
Reset 2
H7CX-AU/-AUD1
1-stage Contact, 1-stage Transistor Output
7
8
9
10
0V
6
(−)
Sensor, etc.
(+)
12 VDC
External power
supply
11
1
12
2
3
13
4
OUT1 or 2
5
OUT 1 or 2
(−)
(+)
Note: Each output can be flexibly allocated to either
stage 1 or 2 by setting in function selection mode.
Multifunction Preset Counter
H7CX
C-95
■ Input Circuits
CP1, CP2, Reset/Reset 1, and Total Reset/Reset 2 Input
+14 V
1 kΩ
Internal
circuit
IN
Note: The circuit shown above is for no-voltage input (NPN input).
■ Input Connections
The inputs of the H7CX are no-voltage (short-circuit or open) inputs or voltage inputs.
No-voltage Inputs (NPN Inputs)
Open Collector
Voltage Output
H7CX-A@
H7CX-A11@
6
7
8
9
10
3
7
5
6
4
H7CX-A@
H7CX-A11@
6
7
8
9
10
3
7
5
6
4
Operates when the transistor turns ON.
Operates when the transistor turns ON.
No-voltage Input Signal Levels
No-contact input
Short-circuit level
Transistor ON
Residual voltage: 3 V max.
Impedance when ON: 1 KΩ max.
(The leakage current is 5 to 20 mA when the
impedance is 0 Ω.)
Open level
Transistor OFF
Impedance when OFF: 100 KΩ min.
Contact input
Use contact which can adequately switch
5 mA at 10 V.
Maximum applicable voltage: 30 VDC max.
Total reset/reset 2 input
DC Two-wire Sensor
CP1 input
CP2 input
Input
Reset/reset 1 input
0V
H7CX-A@
H7CX-A11@
6
7
8
9
10
3
7
5
6
4
Operates when the transistor turns ON.
Applicable Two-wire Sensor
Leakage current:1.5 mA max.
Switching capacity:5 mA min.
Residual voltage:3 VDC max.
Operating voltage:10 VDC
C-96
Multifunction Preset Counter H7CX
H7CX-A@
H7CX-A11@
Total reset/reset 2 input
CP1 input
CP2 input
Reset/reset 1 input
0V
Input
CP1 input
CP2 input
Reset/reset 1 input
0V
Input
CP1 input
CP2 input
Input
Reset/reset 1 input
0V
Total reset/reset 2 input
Sensor
Total reset/reset 2 input
PLC or
sensor
Contact Input
6
7
8
9
10
3
7
5
6
4
Operates when the contact turns ON.
Voltage Inputs (PNP Inputs)
No-contact Input
(NPN Transistor)
6
7
8
9
10
3
7
5
6
4
H7CX-A@
H7CX-A11@
6
7
8
9
10
3
7
5
6
4
Operates when the transistor turns ON.
Operates when the transistor turns OFF.
H7CX-A@
H7CX-A11@
6
7
8
9
10
3
7
5
6
4
Counters
Total reset/reset 2 input
CP1 input
CP2 input
Reset/reset 1 input
0V
Input
CP1 input
CP2 input
Reset/reset 1 input
0V
Input
CP1 input
CP2 input
Input
Reset/reset 1 input
0V
Total reset/reset 2 input
Sensor
Total reset/reset 2 input
Sensor
H7CX-A@
H7CX-A11@
Contact Input
No-contact Input
(PNP Transistor)
Operates when the contact turns ON.
Voltage Input Signal Levels
High level (Input ON):
Low level (Input OFF):
Maximum applicable voltage:
Input resistance:
4.5 to 30 VDC
0 to 2 VDC
30 VDC max.
Approx. 4.7 kΩ
Multifunction Preset Counter
H7CX
C-97
Nomenclature
Indicators
A Reset Indicator (Orange)
Lit when the reset input (1) or reset key
is ON.
B Key Protection Indicator (Orange)
C Control Output Indicator (Orange)
OUT:
One stage
OUT1, OUT2: Two stages
D Total Count Indicator
Lit when the total count value is
displayed.
E Batch Indicator
Lit when the batch count value is
displayed.
F Set Value 1, 2 Stage Indicator
G Present Value (Main Display)
Character height: 11.5 mm (6-digit: 9mm)
H Set Value (Sub-display)
Character height: 6 mm
Operation Keys
1
2
7
3
4
5
6
9
11
10
12
8
Front view of 4-digit model
I Mode Key
Used to switch mode and setting items.
J Reset Key
The operation of the reset function
depends on the configuration selected
as shown in the table below.
K Up Keys: 1 to 4
(6-digit models: 1 to 6)
L Down Keys: 1 to 4
Switches
M Key Protect Switch
1
(Factory setting) OFF
2
7
3
4
5
6
8
ON
N DIP Switch
9
11
10
Front view of 6-digit model
13
14
Reset Operation by Reset Key
Configuration
1-stage/2-stage
counter
Reset operation
Resets the present value and outputs.
Total and preset • Resets the present value and outputs.
counter
• When the total count value is displayed, resets
the present value, the total count value, and
outputs.
C-98
Multifunction Preset Counter H7CX
Batch counter
• Resets the present value and OUT2.
• When the batch count value is displayed,
resets the present value, the batch count
value, and outputs.
Dual counter
Resets the CP1 present value, CP2 present value, dual count value, and outputs.
Tachometer
Maintains the measured value and outputs (hold
function).
Dimensions
Note: All units are in millimeters unless otherwise indicated.
■ Counter (without Flush Mounting Adapter)
Screw-terminal Models with External Power Supplies (Flush Mounting)
• H7CX-AW
• H7CX-AWS
• H7CX-A4W
• H7CX-AWD1
• H7CX-AWSD1
• H7CX-AU
• H7CX-AUD1
• H7CX-AUSD1
Counters
• H7CX-A
• H7CX-AS
• H7CX-A4
• H7CX-A4S
48×48
6
100
44.8×44.8
Note: M3.5 terminal screw (effective length: 6 mm)
Screw-terminal Models without External Power Supplies (Flush Mounting)
• H7CX-AD
• H7CX-ASD
• H7CX-A4D
• H7CX-A4SD
• H7CX-AWSD
• H7CX-AWSD
48×48
6
64
44.8×44.8
Note: M3.5 terminal screw (effective length: 6 mm)
11-pin Socket Models (Flush Mounting/Surface Mounting)
• H7CX-A11
• H7CX-A11S
• H7CX-A11D1
• H7CX-A11SD1
• H7CX-A114
• H7CX-A114S
• H7CX-A114D1
48×48
6
72.5
14.4
44.8×44.8
Multifunction Preset Counter
H7CX
C-99
■ Dimensions with Flush Mounting Adapter
Screw-terminal Models with External Power Supplies
Panel Cutouts
(Provided with Adapter and Waterproof Packing)
• H7CX-AW
• H7CX-AWS
• H7CX-A4W
• H7CX-AWD1
• H7CX-AWSD1
• H7CX-A
• H7CX-AS
• H7CX-A4
• H7CX-A4S
• H7CX-AU
• H7CX-AUD1
• H7CX-AUSD1
Panel cutouts are as
shown below.
(according to DIN43700).
Y92S-29 (provided)
Waterproof Packing
Panel
60 min.
Y92F-30 (provided)
Flush Mounting Adapter
45+0.6
−0
45+0.6
−0
60 min. 15 min.
(51)
58
48
7.5
98.5
Screw-terminal Models without External Power Supplies
(Provided with Adapter and Waterproof Packing)
• H7CX-AD
• H7CX-ASD
• H7CX-A4D
• H7CX-A4SD
• H7CX-AWSD
• H7CX-A4WSD
Y92S-29 (provided)
Waterproof Packing
58
Panel
Y92F-30 (provided)
Flush Mounting Adapter
Note: 1. The mounting panel thickness
should be 1 to 5 mm.
2. To allow easier operability, it is
recommended that Adapters are
mounted so that the gap between
sides with hooks is at least 15 mm
(i.e., so that the panel cutout interval
is at least 60 mm).
3. It is possible to mount counters
side by side, but only in the
direction without the hooks.
If they are mounted side-by-side,
water-resistant specifications
cannot be ensured.
(51)
n side by side mounting
A
48
7.5
A = (48n − 2.5)+10
62.5
11-pin Socket Models
With Y92A-48F1 attached.
A = {48n−2.5 + (n−1) x 4}+10
(Adapter and Waterproof Packing Ordered Separately)
• H7CX-A11
• H7CX-A11S
• H7CX-A11D1
• H7CX-A11SD1
• H7CX-A114
• H7CX-A114S
• H7CX-A114D1
With Y92A-48 attached.
A = (51n−5.5)+10
Y92S-29 (order separately)
Waterproof Packing
58
Panel Y92F-30 (order separately)
Flush Mounting Adapter
P3GA-11
(order separately)
Back Connecting
Socket
(51)
48
7.5
98.7
■ Dimensions with Front Connecting Socket
H7CX
-A11@
109.7
112
P2CF-11
Note: These dimensions vary with the kind of DIN track (reference value).
C-100
Multifunction Preset Counter H7CX
■ Accessories (Order Separately)
Note: All units are in millimeters unless otherwise indicated.
7.8
M3.5 x 7.5 sems
3
4.5
70 max.
Terminal Arrangement/
Internal Connections
(Top View)
35.4
Two, 4.5-dia.
holes
Counters
Track Mounting/Front Connecting Socket
P2CF-11
Eleven,
Surface Mounting Holes
Two, 4.5 dia. or two, M4
4
50 max.
31.2 max.
40±0.2
Note: Track mounting is also possible.
P2CF-11-E (Finger Safe Terminal Type)
Conforming to VDE0106/P100
Eleven,
M3.5 x 7.5 sems
4.5
5
7.8
3
1.2
70 max.
35.4
Two, 4.5-dia.
holes
4
40±0.2
50 max.
30
31.2 max.
Back Connecting Socket
P3GA-11
Terminal Arrangement/
Internal Connections
(Bottom View)
27 dia.
45
25.6
45
4.5
6.2
16.3
Note: Finger protection can be ensured by using in combination with the Y92A-48G Terminal Cover.
Finger Safe Terminal Cover
Conforming to VDE0106/P100
Y92A-48G
(Attachment for P3GA-11
Socket)
Twelve, 6.4-dia. holes
34
47.7 x 47.7
16.5
48 x 48
24.6 27.6
47.4
Multifunction Preset Counter
H7CX
C-101
Hard Cover
Y92A-48
Note: 1. Depending on the operating environment, the condition of
the Soft Cover may deteriorate, and it may shrink or become
harder. Therefore, it is recommended that the Soft Cover is
replaced regularly.
2. The H7CX’s panel surface is water-resistive (conforming to
IP66) and so even if drops of water penetrate the gaps between the keys, there will be no adverse effect on internal
circuits. If, however, there is a possibility of oil being present
on the operator’s hands, use the Soft Cover. The Soft Cover
ensures protection equivalent to IP54F against oil. Do not,
however, use the H7CX in locations where it would come in
direct contact with oil.
Soft Cover
Y92A-48F1
Flush Mounting Adapter
(provided with screw-terminal models)
Waterproof Packing
(provided with screw-terminal models)
Y92F-30
Y92S-29
Mounting Track
PFP-100N, PFP-50N
PFP-100N2
16
7.3±0.15
4.5
4.5
15 25
25
10
35±0.3
27±0.15
35±0.3
25 *
25
1,000 (500) 10
(see note)
15
1
25
25 15
25
25
10
1,000
27
24
1
10
Note: The values shown in parentheses are for the PFP-50N.
End Plate
PFP-M
Spacer
PFP-S
10
6.2
16
12
5
1.8
1
50
1.8
11.5
C-102
10 M4 x 8
pan head
screw
35.5 35.3
34.8
44.3
1.3
4.8
Multifunction Preset Counter H7CX
16.5
29.2
1.5
Precautions
■ Transistor Output
The service life of the output relays depends on the switching
capacity and switching conditions. Consider the actual application
conditions and use the product within the rated load and electrical
service life. Using the product beyond its service life may result in
contact deposition or burning.
The transistor output of the H7CX is isolated from the internal circuitry by a photocoupler, so the transistor output can be used as both
NPN and PNP output.
NPN output
Do not disassemble, repair, or modify the product. Doing so may
result in electric shock, fire, or malfunction.
Do not allow metal objects or conductive wires to enter the product.
Doing so may result in electric shock, fire, or malfunction.
Load
Load
+
+
Power for load
Power for load
The diode connected to the collector of the output transistor is used
to absorb inverted voltage that is generated when an inductive load is
connected to the H7CX.
■ External Power Supply
The capacity of the external power supply is 100 mA at 12 V. When
using a 24 VAC/12 to 24 VDC power supply, reduce the load with the
power supply voltage, as shown in the following diagram (DC power
supplies only).
(DC v ltage
PNP output
Counters
!Caution
Do not