AGILENT HCPL-7723-300

Agilent HCPL-7723 & HCPL-0723
50 MBd 2 ns PWD
High Speed CMOS Optocoupler
Data Sheet
Description
Available in either 8-pin DIP or
SO-8 package style respectively, the
HCPL-7723 or HCPL-0723
optocoupler utilize the latest CMOS
IC technology to achieve outstanding speed performance of
minimum 50 MBd data rate and
2 ns maximum pulse width
distortion.
Basic building blocks of HCPL7723/0723 are a CMOS LED
driver IC, a high speed LED and a
CMOS detector IC. A CMOS logic
input signal controls the LED
driver IC, which supplies current
to the LED. The detector IC
incorporates an integrated
photodiode, a high speed
transimpedance amplifier, and a
voltage comparator with an
output driver.
Functional Diagram
**VDD1
1
8
VDD2**
VI
2
7
NC*
*
3
6
VO
5
GND2
Features
• +5 V CMOS compatibility
• High speed: 50 MBd min.
• 2 ns max. pulse width distortion
• 22 ns max. prop. delay
• 16 ns max. prop. delay skew
• 10 kV/µs min. common mode
rejection
• –40 to 85°C temperature range
• Safety and regulatory approvals
(Pending)
UL recognized
– 2500 V rms for 1 min. per UL1577
for HCPL-7723
– 3750 V rms for 1 min. per UL1577
for HCPL-0723
CSA component acceptance
notice #5
VDE 0884
– Viorm = 630 Vpeak for HCPL-7723
option 060
– Viorm = 560 Vpeak for HCPL-0723
option 060
IO
LED1
GND1
4
SHIELD
* PIN 3 IS THE ANODE OF THE INTERNAL LED AND MUST BE LEFT
UNCONNECTED FOR GUARANTEED DATASHEET PERFORMANCE.
PIN 7 IS NOT CONNECTED INTERNALLY.
** A 0.1 µF BYPASS CAPACITOR MUST BE CONNECTED BETWEEN
PINS 1 AND 4, AND 5 AND 8.
TRUTH TABLE
(POSITIVE LOGIC)
VI, INPUT
LED1
VO, OUTPUT
H
L
OFF
ON
H
L
Applications
• Digital fieldbus isolation: CC-Link,
DeviceNet, Profibus, SDS
• Isolated A/D or D/A conversion
• Multiplexed data transmission
• High Speed Digital Input/Output
• Computer peripheral interface
• Microprocessor system interface
CAUTION: It is advised that normal static precautions be taken in handling and assembly of
this component to prevent damage and/or degradation, which may be induced by ESD.
Package Outline Drawings
HCPL-7723 8-Pin DIP Package
9.65 ± 0.25
(0.380 ± 0.010)
TYPE NUMBER
8
7
6
7.62 ± 0.25
(0.300 ± 0.010)
5
OPTION 060 CODE*
6.35 ± 0.25
(0.250 ± 0.010)
DATE CODE
A XXXXV
YYWW
1
1.19 (0.047) MAX.
2
3
4
1.78 (0.070) MAX.
5° TYP.
4.70 (0.185) MAX.
+ 0.076
0.254 - 0.051
+ 0.003)
(0.010 - 0.002)
0.51 (0.020) MIN.
2.92 (0.115) MIN.
1.080 ± 0.320
(0.043 ± 0.013)
2
0.65 (0.025) MAX.
2.54 ± 0.25
(0.100 ± 0.010)
DIMENSIONS IN MILLIMETERS AND (INCHES).
*OPTION 300 AND 500 NOT MARKED.
HCPL-7723 Package with Gull Wing Surface Mount Option 300
PAD LOCATION (FOR REFERENCE ONLY)
9.65 ± 0.25
(0.380 ± 0.010)
8
6
7
1.016 (0.040)
1.194 (0.047)
5
4.826 TYP.
(0.190)
6.350 ± 0.25
(0.250 ± 0.010)
1
3
2
9.398 (0.370)
9.906 (0.390)
4
1.194 (0.047)
1.778 (0.070)
9.65 ± 0.25
(0.380 ± 0.010)
1.780
(0.070)
MAX.
1.19
(0.047)
MAX.
7.62 ± 0.25
(0.300 ± 0.010)
4.19 MAX.
(0.165)
1.080 ± 0.320
(0.043 ± 0.013)
0.635 ± 0.25
(0.025 ± 0.010)
0.635 ± 0.130
(0.025 ± 0.005)
2.54
(0.100)
BSC
0.381 (0.015)
0.635 (0.025)
+ 0.076
0.254 - 0.051
+ 0.003)
(0.010 - 0.002)
12° NOM.
DIMENSIONS IN MILLIMETERS AND (INCHES).
LEAD COPLANARITY = 0.10 mm (0.004 INCHES).
HCPL-0723 Small Outline SO-8 Package
TYPE NUMBER
8
7
6
5
5.842 ± 0.203
(0.236 ± 0.008)
XXXV
YWW
3.937 ± 0.127
(0.155 ± 0.005)
1
2
3
0.381 ± 0.076
(0.016 ± 0.003)
OPTION 060 CODE*
DATE CODE
4
1.270 BSG
(0.050)
7°
5.080 ± 0.005
(0.200 ± 0.005)
3.175 ± 0.127
(0.125 ± 0.005)
45° X 0.432
(0.017)
0.228 ± 0.025
(0.009 ± 0.001)
1.524
(0.060)
0.152 ± 0.051
(0.006 ± 0.002)
DIMENSIONS IN MILLIMETERS AND (INCHES).
LEAD COPLANARITY = 0.10 mm (0.004 INCHES).
*OPTION 500 NOT MARKED.
3
0.305
MIN.
(0.012)
Device Selection Guide
8-Pin DIP (300 mil)
Small Outline SO-8
HCPL-7723
HCPL-0723
Ordering Information
Specify Part Number followed by Option Number (if desired)
Example:
HCPL-7723-XXX
060 = VDE0884 Option.
300 = Gull Wing Surface Mount Option (HCPL-7723 only).
500 = Tape and Reel Packaging Option.
No Option and Option 300 contain 50 units (HCPL-7723), 100 units (HCPL-0723) per tube. Option 500
contain 1000 units (HCPL-7723), 1500 units (HCPL-0723) per reel. Option data sheets available. Contact
sales representative or authorized distributor.
4
Solder Reflow Temperature Profile
300
TEMPERATURE (°C)
PREHEATING RATE 3°C + 1°C/–0.5°C/SEC.
REFLOW HEATING RATE 2.5°C ± 0.5°C/SEC.
PEAK
TEMP.
245°C
PEAK
TEMP.
240°C
PEAK
TEMP.
230°C
200
2.5°C ± 0.5°C/SEC.
30
SEC.
160°C
150°C
140°C
SOLDERING
TIME
200°C
30
SEC.
3°C + 1°C/–0.5°C
100
PREHEATING TIME
150°C, 90 + 30 SEC.
50 SEC.
TIGHT
TYPICAL
LOOSE
ROOM
TEMPERATURE
0
0
50
100
150
200
250
TIME (SECONDS)
Regulatory Information
The HCPL-7723/0723 will be
approved by the following
organizations:
UL
Recognized under UL1577,
component recognition program,
File E55361.
CSA
Approved under CSA Component
Acceptance Notice #5, File
CA88324.
VDE
(HCPL-7723 option 060)
Approved according to VDE
0884/06.92, File 6591-23-48801005.
TUV Rheinland
(HCPL-0723 Option 060)
Approved according to VDE
0884/06.92, Certificate
R9650938.
Insulation and Safety Related Specifications
Value
Parameter
Symbol
7723
0723
Units
Conditions
Minimum External Air Gap
(Clearance)
L(I01)
7.1
4.9
mm
Measured from input terminals to output
terminals, shortest distance through air.
Minimum External Tracking
(Creepage)
L(I02)
7.4
4.8
mm
Measured from input terminals to output
terminals, shortest distance path along body.
0.08
0.08
mm
Insulation thickness between emitter and
detector; also known as distance through
insulation.
≥ 175
≥ 175
Volts
DIN IEC 112/VDE 0303 Part 1
IIIa
IIIa
Minimum Internal Plastic Gap
(Internal Clearance)
Tracking Resistance
(Comparative Tracking Index)
Isolation Group
5
CTI
Material Group (DIN VDE 0110, 1/89, Table 1)
All Agilent data sheets report the
creepage and clearance inherent
to the optocoupler component
itself. These dimensions are
needed as a starting point for the
equipment designer when
determining the circuit insulation
requirements. However, once
mounted on a printed circuit
board, minimum creepage and
clearance requirements must be
met as specified for individual
equipment standards. For
creepage, the shortest distance
path along the surface of a
printed circuit board between the
solder fillets of the input and
output leads must be considered.
There are recommended
techniques such as grooves and
ribs, which may be used on a
printed circuit board to achieve
desired creepage and clearances.
Creepage and clearance distances
will also change depending on
factors such as pollution degree
and insulation level.
VDE 0884 Insulation Related Characteristics (Option 060)
HCPL-7723
Option 060
HCPL-0723
Option 060
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150 V rms
for rated mains voltage ≤ 300 V rms
for rated mains voltage ≤ 450 V rms
I-IV
I-IV
I-III
I-IV
I-III
Climatic Classification
55/85/21
55/85/21
Pollution Degree (DIN VDE 0110/1.89)
2
2
Description
Symbol
Units
Maximum Working Insulation Voltage
VIORM
630
560
V peak
Input to Output Test Voltage, Method b*
VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
Partial Discharge < 5 pC
VPR
1181
1050
V peak
Input to Output Test Voltage, Method a*
VIORM x 1.5 = VPR, Type and Sample Test, tm = 60 sec,
Partial Discharge < 5 pC
VPR
945
840
V peak
Highest Allowable Overvoltage*
(Transient Overvoltage, tini = 10 sec)
VIOTM
6000
4000
V peak
150
150
600
°C
mA
mW
≥ 109
Ω
Safety Limiting Values (maximum values allowed in the
event of a failure, also see Thermal Derating curve,
Figure 11)
Case Temperature
Input Current
Output Power
175
TS
230
IS,INPUT
PS,OUTPUT 600
Insulation Resistance at TS, VIO = 500 V
RIO
≥ 109
*Refer to the front of the optocoupler section of the Isolation and Control Component Designer’s Catalog, under Product Safety Regulations section
(VDE 0884), for a detailed description.
Note: These optocouplers are suitable for “safe electrical isolation” only within the safety limit data. Maintenance of the safety data shall be
ensured by means of protective circuits.
Note: The surface mount classification is Class A in accordance with CECC 00802.
6
Absolute Maximum Ratings
Parameter
Symbol
Min.
Max.
Units
Storage Temperature
TS
–55
125
°C
Ambient Operating Temperature[1]
TA
–40
85
°C
Supply Voltages
VDD1 , VDD2
0
6.0
Volts
Input Voltage
VI
–0.5
VDD1 +0.5
Volts
Output Voltage
VO
–0.5
VDD2 +0.5
Volts
Average Output Current
IO
10
mA
Lead Solder Temperature
260°C for 10 sec., 1.6 mm below seating plane
Solder Reflow Temperature Profile
See Solder Reflow Temperature Profile Section
Recommended Operating Conditions
Parameter
Symbol
Min.
Max.
Units
Ambient Operating Temperature
TA
–40
85
°C
Supply Voltages
VDD1 , VDD2
4.5
5.5
V
Logic High Input Voltage
VIH
2.0
VDD1
V
Logic Low Input Voltage
VIL
0.0
0.8
V
Input Signal Rise and Fall Times
tr, tf
1.0
ms
Electrical Specifications
Test conditions that are not specified can be anywhere within the recommended operating range.
All typical specifications are at TA = +25°C, VDD1 = VDD2 = +5 V.
Parameter
Symbol
Logic Low Input Supply Current[2]
Logic High Input Supply Current [2]
Output Supply Current
Min.
Typ.
Max.
Units
Test Conditions
IDD1L
7
10
mA
VI = 0 V
IDD1H
1.8
3
mA
VI = VDD1
IDD2L
12.5
17.5
mA
IDD2H
12
16.5
mA
10
µA
Input Current
II
–10
Logic High Output Voltage
VOH
4.4
5.0
V
IO = –20 µA, VI = VIH
4.0
4.8
V
IO = –4 mA, V I = VIH
Logic Low Output Voltage
7
VOL
0
0.1
V
IO = 20 µA, VI = VIL
0.5
1.0
V
IO = 4 mA, V I = VIL
Switching Specifications
Test conditions that are not specified can be anywhere within the recommended operating range.
All typical specifications are at T A = +25°C, VDD1 = VDD2 = +5 V.
Parameter
Symbol
Propagation Delay Time to Logic
Low Output[3]
Typ.
Max.
Units
Test Conditions
t PHL
16
22
ns
CL = 15 pF CMOS Signal Levels
Propagation Delay Time to Logic
High Output[3]
tPLH
16
22
ns
CL = 15 pF CMOS Signal Levels
Pulse Width
PW
20
ns
CL = 15 pF CMOS Signal Levels
50
MBd
CL = 15 pF CMOS Signal Levels
2
ns
CL = 15 pF CMOS Signal Levels
16
ns
CL = 15 pF CMOS Signal Levels
Maximum Data Rate
Min.
Pulse Width Distortion[4] |t PHL - tPLH|
|PWD|
Propagation Delay Skew[5]
tPSK
Output Rise Time (10% – 90%)
tR
8
ns
CL = 15 pF CMOS Signal Levels
Output Fall Time (90% - 10%)
tF
6
ns
CL = 15 pF CMOS Signal Levels
Common Mode Transient Immunity
at Logic High Output[6]
|CMH|
10
15
kV/µs
VCM = 1000 V , TA = 25°C,
VI = VDD1, V O > 0.8 VDD2
Common Mode Transient Immunity
at Logic Low Output[6]
|CML|
10
15
kV/µs
VCM = 1000 V , TA = 25°C,
VI = 0 V , VO < 0.8 V
8
1
Package Characteristics
All Typical Specifications are at T A = 25°C.
Parameter
Input-Output Momentary
Withstand Voltage[7,8,9]
Symbol Min.
–7723
–0723
V ISO
Typ.
Max.
2500
3750
Units
Test Conditions
V rms
RH ≤ 50%, t = 1 min,
T A = 25°C
Input-Output Resistance [7]
R I-O
10 12
Ω
VI-O = 500 V dc
Input-Output Capacitance
C
0.6
pF
f = 1 MHz
Input Capacitance [10]
CI
3.0
pF
–7723
θjci
145
°C/W
–0723
–7723
–0723
θjco
160
145
135
°C/W
Input IC Junction-to-Case
Thermal Resistance
Output IC Junction-to-Case
Thermal Resistance
Package Power Dissipation
I-O
PPD
150
Thermocouple located at
center underside of package
mW
Notes:
1. Absolute Maximum ambient operating temperature means the device will not be damaged if operated under these conditions. It does not
guarantee functionality.
2. The LED is ON when VI is low and OFF when VI is high.
3. tPHL propagation delay is measured from the 50% level on the falling edge of the VI signal to the 50% level of the falling edge of the VO signal.
tPLH propagation delay is measured from the 50% level on the rising edge of the VI signal to the 50% level of the rising edge of the VO signal.
4. PWD is defined as |tPHL - tPLH|. %PWD (percent pulse width distortion) is equal to the PWD divided by pulse width.
5. tPSK is equal to the magnitude of the worst case difference in tPHL and/or tPLH that will be seen between units at any given temperature within
the recommended operating conditions.
6. CMH is the maximum common mode voltage slew rate that can be sustained while maintaining VO > 0.8 VDD2. CML is the maximum common
mode voltage slew rate that can be sustained while maintaining VO < 0.8 V. The common mode voltage slew rates apply to both rising and
falling common mode voltage edges.
7. Device considered a two-terminal device: pins 1, 2, 3, and 4 shorted together and pins 5, 6, 7, and 8 shorted together.
8. In accordance with UL1577, each HCPL-0723 is proof tested by applying an insulation test voltage ≥ 4500 Vrms for 1 second (leakage detection
current limit, II-O ≤ 5 µA). Each HCPL-7723 is proof tested by applying an insulation test voltage ≥ 3000 Vrms for 1 second (leakage detection
current limit. II-O ≤ 5 µA.)
9. The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous
voltage rating. For the continuous voltage rating refer to your equipment level safety specification or Agilent Application Note 1074 entitled
“Optocoupler Input-Output Endurance Voltage.”
10. CI is the capacitance measured at pin 2 (VI).
9
should be between 0.01 µF and 0.1
µF. For each capacitor, the total
lead length between both ends of
the capacitor and the power-supply
pins should not exceed 20 mm.
Figure 2 illustrates the
recommended printed circuit
board layout for the HCPL-7723/
0723.
Application Information
Bypassing and PC Board Layout
The HCPL-7723/0723
optocouplers are extremely easy
to use. No external interface
circuitry is required because the
HCPL-7723/0723 use high-speed
CMOS IC technology allowing
CMOS logic to be connected
directly to the inputs and outputs.
Propagation Delay, Pulse-Width
Distortion and Propagation Delay Skew
Propagation Delay is a figure of
merit which describes how quickly
a logic signal propagates through
As shown in Figure 1, the only
external components required for
proper operation are two bypass
capacitors. Capacitor values
VDD1
VDD2
8
1
a system as illustrated in Figure 3.
The propagation delay from low to
high (tPLH) is the amount of time
required for an input signal to
propagate to the output, causing
the output to change from low to
high. Similarly, the propagation
delay from high to low (tPHL) is
the amount of time required for
the input signal to propagate to
the output, causing the output to
change from high to low.
C1
C2
2
NC 3
GND1
HCPL-7723
OR
HCPL-0723
VI
7 NC
6
VO
5
4
GND2
C1, C2 = 0.01 µF TO 0.1 µF
Figure 1. Functional diagram.
VDD1
VDD2
HCPL-7723
OR
HCPL-0723
VI
C1
C2
VO
GND1
GND2
C1, C2 = 0.01 µF TO 0.1 µF
Figure 2. Recommended printed circuit board layout.
INPUT
VI
5 V CMOS
50%
0V
tPLH
OUTPUT
VO
90%
10%
tPHL
90%
10%
VOH
2.5 V CMOS
VOL
Figure 3. Timing diagram to illustrate propagation delay, tplh and tphl.
10
Pulse-width distortion (PWD) is
the difference between tPHL and
tPHL and often determines the
maximum data rate capability of
a transmission system. PWD can
be expressed in percent by
dividing the PWD (in ns) by the
minimum pulse width (in ns)
being transmitted. Typically,
PWD on the order of 20-30% of
the minimum pulse width is
tolerable.
Propagation delay skew, tPSK, is
an important parameter to
consider in parallel data applications where synchronization of
signals on parallel data lines is a
concern. If the parallel data is
being sent through a group of
VI
optocouplers, differences in
propagation delays will cause the
data to arrive at the outputs of
the optocouplers at different
times. If this difference in
propagation delay is large enough
it will determine the maximum
rate at which parallel data can be
sent through the optocouplers.
Propagation delay skew is defined
as the difference between the
minimum and maximum
propagation delays, either tPLH or
tPHL, for any given group of
optocouplers which are operating
under the same conditions (i.e.,
the same drive current, supply
voltage, output load, and
operating temperature). As
50%
2.5 V,
CMOS
VO
tPSK
VI
50%
2.5 V,
CMOS
VO
Figure 4. Timing diagram to illustrate propagation delay skew, tpsk.
DATA
INPUTS
CLOCK
DATA
OUTPUTS
tPSK
CLOCK
tPSK
Figure 5. Parallel data transmission example.
11
illustrated in Figure 4, if the
inputs of a group of optocouplers
are switched either ON or OFF at
the same time, tPSK is the
difference between the shortest
propagation delay, either tPLH or
tPHL, and the longest propagation
delay, either tPLH or t PHL.
As mentioned earlier, tPSK can
determine the maximum parallel
data transmission rate. Figure 5
is the timing diagram of a typical
parallel data application with
both the clock and data lines
being sent through the
optocouplers. The figure shows
data and clock signals at the
inputs and outputs of the
optocouplers. In this case the
data is assumed to be clocked off
of the rising edge of the clock.
Propagation delay skew
represents the uncertainty of
where an edge might be after
being sent through an
optocoupler. Figure 5 shows that
there will be uncertainty in both
the data and clock lines. It is
important that these two areas of
uncertainty not overlap,
otherwise the clock signal might
arrive before all of the data
outputs have settled, or some of
the data outputs may start to
change before the clock signal
has arrived. From these
considerations, the absolute
minimum pulse width that can be
sent through optocouplers in a
parallel application is twice tPSK .
A cautious design should use a
slightly longer pulse width to
ensure that any additional
uncertainty in the rest of the
circuit does not cause a problem.
The HCPL-7723/0723
optocouplers offer the advantage
of guaranteed specifications for
propagation delays, pulse-width
distortion, and propagation delay
skew over the recommended
temperature and power supply
ranges.
www.agilent.com/semiconductors
For product information and a complete list of
distributors, please go to our web site.
For technical assistance call:
Americas/Canada: +1 (800) 235-0312 or
(408) 654-8675
Europe: +49 (0) 6441 92460
China: 10800 650 0017
Hong Kong: (+65) 6271 2451
India, Australia, New Zealand: (+65) 6271 2394
Japan: (+81 3) 3335-8152(Domestic/International), or 0120-61-1280(Domestic Only)
Korea: (+65) 6271 2194
Malaysia, Singapore: (+65) 6271 2054
Taiwan: (+65) 6271 2654
Data subject to change.
Copyright © 2002 Agilent Technologies, Inc.
December 2, 2002
5988-7986EN