HITRON HDC350P

H HiTRON
18-36VDC INPUT RANGE DC-DC CONVERTER HOT-SWAP CompactPCI
382 WATTS QUAD OUTPUT ACTIVE CURRENT SHARING SWITCHING
POWER SUPPLIES HDC350P-24B-490 SERIES
FEATURES:








382W 6U X 8HP EUROCARD PACKAGE
INTERNAL OR-ING DIODES FOR
N+1 REDUNDANCY
HOT-SWAPPABLE
ACTIVE CURRENT SHARING
CONSTANT CURRENT LIMIT
EMI MEET EN 55022 CLASS A
CE MARKING COMPLIANCE
FULLY COMPLIANT WITH PICMG
SPECIFICATION
INPUT SPECIFICATION
Input Voltage: Typ. 18-36Vdc, nominal input 24Vdc.
Under Voltage Shutdown: Installed.
Input Connector: Positronic 47-pin PCIH47M400A1.
Soft Start: Installed.
Inrush Current: 56.5A (peak) at 36Vdc.
Input Current: 19.7A at nominal input 24Vdc (Full load).
Dielectric Withstand: Meet IEC 60950-1 regulation.
EMI: Meet CISPR EN 55022 Class A.
Remote ON/OFF: Available at [INH#] &[EN#] pins.
Power Fail Signal: Available at [FAL#] pins.
Status LED: <Green> means valid input voltage.
<Amber> means a critical fault.
Thermal Protection (OTP): Installed NTC for
thermal sensor at [DEG#] pin.
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Power: Typ. 382W continuous.
Output Connector: Positronic 47-Pin PCIH47M400A1.
Line Regulation: Typ. 0.5%.
Load Regulation: Typ. VO1/2 ±1.5%; VO3 ±3%;VO4 ±5%.
Total Regulation: Typ. VO1/2 2% , VO3 4%, VO4 5%.
Noise & Ripple: 1% peak-peak or 50mV, whichever is greater.
OVP: Built-in at all outputs.(Latch).
Adjustability: Available for all outputs.
Output Trim: Electrical trim available at VO1/VO2.[ADJ #].
Remote Sensing: Available for VO1,VO2 & VO3.
Hot-Swap: Available.
N+1 Redundancy: Available with OR-ing diodes at all outputs
for N+1 redundancy.
Current Sharing: Active current sharing at VO1,2&3.
Constant Current Limit: Available for each outputs &
shutdown in 3-8 sec.
Power OK Signal: Available for all outputs.
DC OK Signal: Available for all outputs.
Over Current Protection (OCP): Installed at each rail.
Overload Protection (OLP): Fully protected.
GENERAL SPECIFICATION
Efficiency: Typ. 81.8%.
Switching Frequency: 120K Hz.
Circuit Topology: Forward circuit.
Transient Response: Peak transient less than 250mV and
recovers within 3mS after 25% load-change.
Safety Standard: IEC 60950-1 Class I.
Construction: Eurocard 6U X 8HP X 160mm
CompactPCI format. Front Panel with Extractor handle.
Operating Temperature: -20 °C to +50 °C at full load with
600LFM air flow. Derates linearly to 50% at +70 °C.
Or -20 °C to +70 °C at full load with 800LFM air flow.
Derates linearly to 60% at +80 °C.
Storage Temperature: -40 °C to +85 °C.
Cooling: At least 600LFM or 800LFM moving air is required
to achieve full rating power 382W in a confined area.
Power Density: 3.45 Watts/ Cubic Inch.
NOTE: (1)All measurement are at nominal input, full load and +25°C unless otherwise specifications.
(2)Due to requests in market and advances in technology, specifications subject to change without notification.
-119-
OUTPUT VOLTAGE / CURRENT RATINGS CHART
QUAD OUTPUT
MAIN +VO1 @★⊙#≡
AUX. +VO2 @★⊙#≡
AUX. +VO3 ▲@★⊙#≡
AUX. –VO4 ▲@★⊙
MODEL NO.
Min. Typ. Volt. Max Pk.
HDC350P-24B-490
0A
33A +5V 50A 50A
Min. Typ. Volt.
0A
Max
Pk. Min. Typ. Volt.
33A +3.3V 50A 50A 0A
7A
+12V
Max Pk. Min. Typ. Volt. Max Pk.
9A 10A 0A
2A -12V 4A
5A
Symbol: "★" OVP built-in. "@" Adjustable. "#" Remote sensing. "≡" Active Load Sharing.
"⊙" Installed with Or-ing diode. "▲" Magnetic Amplifier.
Remark: Peak load less than 60sec. with duty cycle <10%.
Max. load is the continuous operating load of each rail. But the max. load of each rail can't be drawn from all outputs at the same time.
Total Max, Power of VO1 and VO2 must be less than 300Watt.
MECHANICAL DIMENSIONS: MM [INCHES]
WEIGHT: 1.72kg (3.78 lb.)
INPUT & OUTPUT CONNECTORS PIN ASSIGNMENT
DC
INPUT
ASSIGNMENT
CNTR &PIN #
+Vin -Vin
46
47
QUAD OUTPUT
G
45
VO1 VO1 VO1 VO1
VO2 VO2 VO2
VO3 VO3
VO1
VO2
VO3
VO4 DC COM
S+
S- Adj. C.S.
S+ Adj. C.S.
S+ C.S
13,14,
5,6,7,8,9,
1,2,
30
34
29
35 15,16, 33
32
41
20
36
44
21 10,11,12,
3,4
17,18
19,24
Mating connector: PCIH47F400A1.
-120-
STATUS/CONTROL
EN#
27
DEG# INH# FAL#
38
39
42