PANASONIC HE1AN-P-DC6V-H18

Automation Controls Catalog
VDE
Ideal for solar inverter
compact size,
1a 35A/48A power relays
HE RELAYS
PV Type
FEATURES
• 35A/48A current at 250 V AC
achieved in compact size (L: 33 × W:
38 × H: 36.3 mm L: 1.299 × W: 1.496 ×
H: 1.429 inch)
Due to improved conduction efficiency,
wide terminal blades are used. (for high
capacity type)
• High insulation and 10,000 V surge
breakdown voltage (between contacts
and coil) achieved.
• Conforms to various safety
standards
UL/C-UL and VDE
TYPICAL APPLICATIONS
• Photovoltaic power generation
systems (Solar inverter)
RoHS compliant
• Contact gap: 2.5 mm (VDE0126
compliant)
Compliant with European photovoltaic
standard VDE0126
Compliant with EN61810-1 2.5 kV surge
breakdown voltage (between contacts)
• Contributes to energy saving in
devices thanks to reduced coil hold
voltage
Coil hold voltage can be reduced down to
40% of the nominal coil voltage (ambient
temperature 20°C 68°F). This equals to
operating power of approximately 310
mW.
*Coil hold voltage is the coil voltage after
100 ms following application of the
nominal coil voltage.
ORDERING INFORMATION
HE 1a
N
P
DC
Contact arrangement
1a: 1 Form A (Single side stable type)
Pick-up voltage
N: 70% of nominal voltage
Terminals
P: PC board terminal type
Coil voltage (DC)
6, 9, 12, 24V
Type, contact material and switching capacity
Y5: PV type, AgNi type (1 Form A 48A high capacity)
H18: PV type, AgSnO2 type (1 Form A 35A standard)
2013.07
industrial.panasonic.com/ac/e/
–1–
© Panasonic Corporation 2013
ASCTB101E 201307-T
HE PV Type
TYPES
Standard type*
Part No.
HE1aN-P-DC6V-H18
HE1aN-P-DC9V-H18
HE1aN-P-DC12V-H18
HE1aN-P-DC24V-H18
Nominal coil
voltage
6V DC
9V DC
12V DC
24V DC
High capacity type
Part No.
HE1aN-P-DC6V-Y5
HE1aN-P-DC9V-Y5
HE1aN-P-DC12V-Y5
HE1aN-P-DC24V-Y5
Standard packing: Carton: 20 pcs.; Case: 100 pcs.
*Standard 6V, 12V and 24V DC type: Certified by UL/C-UL (Standard 9V type: Certified by UL/C-UL and VDE)
RATING
1. Coil data
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
(Initial)
Drop-out voltage
(at 20°C 68°F)
(Initial)
70%V or less of
nominal voltage
10%V or more of
nominal voltage
6V DC
9V DC
12V DC
24V DC
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
320mA
18.8Ω
213mA
160mA
80mA
42.2Ω
75.0Ω
300.0Ω
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
1,920mW
110%V of
nominal voltage
2. Specifications
Characteristics
Contact
Rating
Item
Arrangement
Contact resistance (Initial)
Contact material
Nominal switching capacity
Contact carring power
Max. switching voltage
Max. switching current
Nominal operating power
Min. switching capacity (Reference value)*1
Insulation resistance (Initial)
Specifications
Standard type
High capacity type
1 Form A
Max. 100 mΩ (By voltage drop 6 V DC 1A)
AgNi type
AgSnO2 type
35 A 250 V AC (Resistive load)
48 A 250 V AC (Resistive load)
8,750 VA (Resistive load)
12,000 VA (Resistive load)
250 V AC
35 A (AC)
48 A (AC)
1,920 mW
100 mA 5 V DC
Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Between open contacts
Between contact and coil
Surge breakdown voltage*2
(Between contact and coil) (Initial)
2,000 Vrms for 1 min. (Detection current: 10 mA)
5,000 Vrms for 1 min. (Detection current: 10 mA)
Breakdown
voltage (Initial)
Max. 60°C 140°F (By resistive method,
contact carrying current: 35A, 100%V of nominal
coil voltage at 55°C 131°F.)
Temperature rise
Coil hold voltage*3
Operate time (at 20°C 68°F)
Release time (at 20°C 68°F)*5
Functional
Shock
resistance
Destructive
Vibration
resistance
Functional
Destructive
Mechanical
Resistive load
Expected life
Conditions
Electrical
Max. 60°C 140°F (By resistive method,
contact carrying current: 48A, 100%V of nominal
coil voltage at 55°C 131°F.)
Max. 30°C 86°F (By resistive method, contact
carrying current: 35A, 60%V of nominal coil
voltage at 85°C 185°F.)
40 to 100%V (Contact carrying current:
35A, at 20°C 68°F),
50 to 100%V (Contact carrying current:
35A, at 55°C 131°F),
50 to 60%V (Contact carrying current:
35A, at 85°C 185°F)
Electrical
characteristics
Mechanical
characteristics
10,000 V
Inductive load
Conditions for operation, transport and
storage*4
Max. operating speed
Unit weight
Max. 30°C 86°F (By resistive method, contact
carrying current: 48A, 60%V of nominal coil
voltage at 85°C 185°F.)
40 to 100%V (Contact carrying current:
48A, at 20°C 68°F),
50 to 100%V (Contact carrying current:
48A, at 55°C 131°F),
50 to 60%V (Contact carrying current:
48A, at 85°C 185°F)
Max. 30 ms (nominal coil voltage, excluding contact bounce time)
Max. 10 ms (nominal coil voltage, excluding contact bounce time) (without diode)
Min. 98 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10 µs.)
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 1.0 mm (Detection time: 10 µs.)
10 to 55 Hz at double amplitude of 1.5 mm
Min. 106 (at 180 times/min.)
Min. 3×104 (35 A 250 V AC) (ON : OFF = 1s : 9s) Min. 3×104 (48 A 250 V AC) (ON : OFF = 1s : 9s)
Endurance: 48 A 250 V AC (cosφ = 0.8),
Min. 3×104 (ON : OFF = 0.1s : 10s)
—
Overload: 72 A 250 V AC (cosφ = 0.8),
Min. 50 (ON : OFF = 0.1s : 10s)
Ambient temperature:
–50 to +55°C –58 to +131°F (When nominal coil voltage applied)
–50 to +85°C –58 to +185°F (When applied coil hold voltage is 50% to 60% of nominal coil voltage)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature);
Atmospheric pressure: 86 to 106 kPa
6 times/min. (at nominal switching capacity ON : OFF = 1s : 9s)
Approx. 80 g 2.82 oz
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981
*3. Coil hold voltage is the coil voltage after 100 ms following application of the nominal coil voltage.
*4. The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
*5. Release time will lengthen if a diode, etc., is connected in parallel to the coil. Be sure to verify operation under actual conditions.
Panasonic Corporation Automation Controls Buisiness Division
industrial.panasonic.com/ac/e/
–2–
© Panasonic Corporation 2013
ASCTB101E 201307-T
HE PV Type
REFERENCE DATA
1.-(1) Coil temperature rise
(Standard type)
1.-(2) Coil temperature rise
(High capacity type)
Sample: HE1aN-P-DC9V-H18, 6 pcs.
Point measured: coil inside
Ambient temperature: 25°C 77°F, 60°C 140°F, 85°C
185°F
Contact carrying current: 35A
Sample: HE1aN-P-DC9V-Y5, 6 pcs.
Point measured: coil inside
Ambient temperature: 25°C 77°F, 60°C 140°F, 85°C
185°F
Contact carrying current: 48A
70
25°C
50
60°C
40
85°C
30
60
10
10
60
70
80
90
0
100
85°C
30
20
50
60°C
40
20
0
25°C
50
50
Coil applied voltage, %V
60
70
80
90
100
Coil applied voltage, %V
2.-(1) Electrical life test (Standard type, Resistive load 250V AC, 35A at 85°C 185°F)
Sample: HE1aN-P-DC9V-H18, 6 pcs.
Change of pick-up and drop-out voltage
Circuit:
250V AC
9V DC
Contact
welding
detection
and Miscontacting
detection
circuit
Pick-up and drop-out voltage, V
Operation frequency: 6 times/min.
(ON/OFF = 1.0s : 9.0s)
Change of contact resistance
9
100
8
90
7
6
5
Pick-up voltage
Max.
x
Min.
4
3
2
Drop-out voltage
Contact resistance, mΩ
60
Temperature rise, °C
Temperature rise, °C
70
Max.
x
Min.
1
80
70
60
50
40
30
20
0
0
3
No. of operations, ×104
9V DC
Change of contact resistance
9
100
8
90
7
6
5
Pick-up voltage
Max.
x
Min.
4
3
2
Drop-out voltage
Max.
x
Min.
1
Contact resistance, mΩ
250V AC
Contact
welding
detection
and Miscontacting
detection
circuit
Pick-up and drop-out voltage, V
Circuit:
80
70
60
50
40
30
20
Max.
x
Min.
10
0
0
3
0
0
No. of operations, ×104
Panasonic Corporation Automation Controls Buisiness Division
industrial.panasonic.com/ac/e/
3
No. of operations, ×104
2.-(2) Electrical life test (High capacity type, Resistive load 250V AC, 48A at 85°C 185°F)
Sample: HE1aN-P-DC9V-Y5, 6 pcs.
Change of pick-up and drop-out voltage
Operation frequency: 6 times/min.
(ON/OFF = 1.0s : 9.0s)
Max.
x
Min.
10
0
0
–3–
3
No. of operations, ×104
© Panasonic Corporation 2013
ASCTB101E 201307-T
HE PV Type
DIMENSIONS (mm inch)
The CAD data of the products with a
Standard type
External dimensions
CAD Data
38.0
1.496
CAD Data
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
Schematic (Bottom view)
PC board pattern (Bottom view)
Single side stable type
33
1.299
1
4
4.7
.185
24
.945
8.4
.331
0.5
.020
1.6
.063
0.8
.031
4.7
.185
36.3
1.429
6
4
.157
1.6
.063
5
32
1.260
0.8
.031
General tolerance: ±0.3 ±.012
High capacity type
External dimensions
38.0
1.496
Tolerance: ±0.1 ±.004
Schematic (Bottom view)
PC board pattern (Bottom view)
Single side stable type
33
1.299
18.6
.732
6-2 dia. hole
6-.079 dia. hole
1
4
6.5
.256
24
.945
8.4
.331
0.5
.020
0.8
.031
6.3
.248
36.3
1.429
4
.157
6
5
18.6
.732
1.3
.051
2-2 dia. hole
2-.079 dia. hole
1.6
.063
32
1.260
0.8
.031
General tolerance: ±0.3 ±.012
Tolerance: ±0.1 ±.004
SAFETY STANDARDS
Certification body
C-UL
High capacity type
VDE (VDE0435)
Standard type
UL/CSA
VDE (VDE0435)**
Contact rating
48A 277V AC (at 85°C 185°F)
*60A 277V AC (general use, at 60°C 140°F, 10k cycle), in use at 60% of rated coil voltage
48A 250V AC cosφ = 0.8 (at 85°C 185°F)
*72A 250V AC (cosφ = 0.8 at 85°C 185°F, 50 cycle)
*60A 250V AC (cosφ = 0.8 at 85°C 185°F, 10k cycle)
*50A 20V DC (0ms, at 85°C 185°F, 30k cycle)
35A 277V AC (at 25°C 77°F)
35A 250V AC cosφ = 1 (at 80°C 176°F)
* Under development. Please contact us.
** Only 9V DC type is Certified by VDE
Panasonic Corporation Automation Controls Buisiness Division
industrial.panasonic.com/ac/e/
–4–
© Panasonic Corporation 2013
ASCTB101E 201307-T
HE PV Type
NOTES
Usage, transport and storage
conditions
1) Temperature:
–50 to +55°C –58 to +131°F
–50 to +85°C –58 to +185°F (When
applied coil hold voltage is 50% to 60% of
nominal coil voltage)
2) Humidity: 5 to 85% RH
(Avoid freezing and condensation.)
The humidity range varies with the
temperature. Use within the range
indicated in the graph below.
3) Atmospheric pressure: 86 to 106 kPa
Temperature and humidity range for
usage, transport, and storage
Humidity, %RH
85
Tolerance range
(Avoid freezing
when used at
temperatures
lower than
0°C 32°F)
5
–50
–58
(Avoid
condensation
when used at
temperatures
higher than
0°C 32°F)
0
+32
Certification
This relay is UL/C-UL certified.
48 A 277 V AC (High capacity type)
35 A 277 V AC (Standard type)
This relay is certified by VDE
48 A 250 V AC cosφ = 0.8
(High capacity type)
35 A 250 V AC cosφ = 1
(Standard type)
55
+131
Temperature, °C °F
Humidity, %RH
85
Tolerance range
(Avoid freezing
when used at
temperatures
lower than
0°C 32°F)
5
–50
–58
(Avoid
condensation
when used at
temperatures
higher than
0°C 32°F)
0
+32
Temperature, °C °F
85
+185
∗ –50 to +85°C –58 to +185°F (When applied
coil hold voltage is 50% to 60% of nominal
coil voltage)
Panasonic Corporation Automation Controls Buisiness Division
industrial.panasonic.com/ac/e/
–5–
© Panasonic Corporation 2013
ASCTB101E 201307-T