ETC HFA35HB120

PD-20370
HFA35HB120
HEXFRED
TM
Ultrafast, Soft Recovery Diode
Features
•
•
•
•
•
•
VR = 1200V
(ISOLATED BASE)
Reduced RFI and EMI
Reduced Snubbing
Extensive Characterization of Recovery Parameters
Hermetic
Electrically Isolated
Ceramic Eyelets
VF = 3.1V
Qrr = 510 nC
CATHODE
di(rec)M/dt = 350A/µs
ANODE
Description
TM
HEXFRED diodes are optimized to reduce losses and
EMI/RFI in high frequency power conditioning systems.
An extensive characterization of the recovery behavior
for different values of current, temperature and di/dt
simplifies the calculations of losses in the operating
conditions. The softness of the recovery eliminates the
need for a snubber in most applications. These devices
are ideally suited for power converters, motors drives and
other applications where switching losses are significant
portion of the total losses.
TO-254AA
Absolute Maximum Ratings (per Leg)
Parameter
VR
IF @ TC = 100°C
IFSM @ TC = 25°C
PD @ TC = 25°C
TJ
TSTG
D.C. Reverse Voltage
Continuous Forward Current 
Single Pulse Forward Current ‚
Maximum Power Dissipation
Operating Junction and
Storage Temperature Range
Max.
Units
1200
11
190
83
-55 to +150
V
A
W
°C
Thermal - Mechanical Characteristics
Parameter
RθJC
Junction-to-Case, Single Leg Conducting
Weight
Typ.
Max.
Units
—
9.3
1.5
—
°C/W
g
Note:  D.C. = 50% rect. wave
‚ 1/2 sine wave, 60 Hz , P.W. = 8.33 ms
www.irf.com
1
6/30/99
HFA35HB120
Electrical Characteristics (per Leg) @ TJ = 25°C (unless otherwise specified)
Parameter
VBR
VFM
Min. Typ. Max. Units
Cathode Anode Breakdown Voltage
Max Forward Voltage
IRM
Max Reverse Leakage Current
CT
LS
Junction Capacitance
Series Inductance
1200 —
—
—
—
—
—
—
—
—
—
—
—
28
—
8.7
—
3.1
4.0
2.7
10
1.0
42
—
V
V
µA
mA
pF
nH
Test Conditions
IR = 100µA
IF = 11A
IF = 22A
See Fig. 1
IF = 11A, TJ = 125°C
VR = VR Rated
See Fig. 2
TJ = 125°C, VR = 960V
VR = 200V
See Fig. 3
Measured from center of bond pad to
end of anode bonding wire
Dynamic Recovery Characteristics (per Leg) @ TJ = 25°C (unless otherwise specified)
Parameter
trr1
trr2
IRRM1
IRRM2
Q rr1
Q rr2
di(rec)M/dt1
di(rec)M/dt2
Min. Typ. Max. Units
Reverse Recovery Time
Peak Recovery Current
Reverse Recovery Charge
Peak Rate of Fall of Recovery Current
During tb
—
—
—
—
—
—
—
—
80
130
7.25
10.2
340
825
230
160
120
ns
195
10.9
A
15.3
510
nC
1240
350
A/µs
240
Test Conditions
TJ = 25°C
TJ = 125°C
TJ = 25°C
TJ = 125°C
TJ = 25°C
TJ = 125°C
T J = 25°C
TJ = 125°C
See Fig.
5
IF = 11A
See Fig.
6
VR = 200V
See Fig.
7
dif/dt = 200A/µs
See Fig.
8
Case Outline and Dimensions — TO-254AA
.12 ( .00 5 )
1 3.8 4 ( .545 )
1 3.5 9 ( .535 )
3.7 8 ( .149 )
3.5 3 ( .139 )
-A-
20 .3 2 ( .8 00 )
20 .0 7 ( .7 90 )
17.4 0 ( .68 5 )
16.8 9 ( .66 5 )
3 1.40 ( 1.2 35 )
3 0.39 ( 1.1 99 )
6 .6 0 ( .2 60 )
6 .3 2 ( .2 49 )
1
2
-B1 .2 7 ( .0 50 )
1 .0 2 ( .0 40 )
13 .84 ( .5 45 )
13 .59 ( .5 35 )
L E G E ND
1 - C O L LE C TO R
W
2 - E M ITT E R
3
-C -
3X
3.81 ( .15 0 )
2X
1 .1 4 ( .0 45 )
0 .8 9 ( .0 35 )
.5 0 ( .0 20 )
.2 5 ( .0 10 )
1 2 3
3 - G A TE
3 .81 ( .1 50 )
M C A M B
M C
N O TE S :
1 . D IM E N S IO N ING & TO L E R A NC IN G P E R A N S I Y 14 .5 M , 198 2.
2 . A L L D IM E N S IO N S A RE S H O W N IN M IL LIM E TE RS ( IN C H E S ) .
LEGEND
1- CATHODE
2- N/C
3- ANODE
Conforms to JEDEC Outline TO-254AA
Dimensions in Millimeters and ( Inches )
CAUTION
BERYLLIA WARNING PER MIL- PRF-19500
Package containing beryllia shall not be ground, sandblasted,machined, or have other operations performed on them
which will produce beryllia or beryllium dust. Furthermore, beryllium oxide packages shall not be placed in acids that
will produce fumes containing beryllium.
2
www.irf.com
HFA35HB120
R eve rse C urre nt - I R (µA )
10000
TJ = 150°C
TJ = 125°C
1000
TJ = 15 0 °C
100
TJ = 1 25 °C
10
1
0.1
T J = 2 5 °C
0.01
T J = -5 5°C
0.001
TJ = 25°C
0
10
300
600
900
1200
R e ve rse V o lta g e - V R (V )
Fig. 2 - Typical Reverse Current vs. Reverse
Voltage
Ju nction C a pa citan ce - C T (p F )
Instantaneous Forward C urrent - I F (A)
100
1000
1
0.0
2.0
4.0
6.0
8.0
10.0
Forward V oltage Drop - V FM (V )
Fig. 1 - Maximum Forward Voltage Drop
vs. Instantaneous Forward Current
A
TJ = 25°C
100
10
1
10
100
1000
R e verse V oltag e - V R (V )
Fig. 3 - Typical Junction Capacitance vs.
Reverse Voltage
Thermal Response (Z thJC)
10
1
D = 0.50
0.20
0.10
0.1
PDM
0.05
0.02
0.01
0.01
0.00001
t1
t2
SINGLE PULSE
(THERMAL RESPONSE)
0.0001
Notes:
1. Duty factor D = t 1 / t 2
2. Peak TJ = P DM x Z thJC + TC
0.001
0.01
0.1
1
10
t1 , Rectangular Pulse Duration (sec)
Fig. 4 - Maximum Thermal Impedance Zthjc Characteristics
www.irf.com
3
HFA35HB120
250
100
I F = 22A
I F = 11A
200
I F = 5.5A
I F = 22 A
Irr- ( A)
150
trr - (n s )
IF = 1 1 A
I F = 5 .5 A
10
100
50
VR = 2 0 0 V
T J = 1 2 5 °C
T J = 2 5 °C
0
100
VR = 2 0 0 V
T J = 1 2 5 °C
T J = 2 5 °C
d i f /d t - (A /µ s)
1
100
1000
Fig. 5 - Typical Reverse Recovery vs. dif/dt,
di f /d t - (A /µs)
1000
Fig. 6 - Typical Recovery Current vs. dif/dt,
10000
10000
VR = 2 0 0V
T J = 1 2 5 °C
T J = 2 5 °C
I F = 22 A
IF = 11A
d i(re c )M /d t - (A /µ s )
Q R R - (n C )
I F = 5 .5A
1000
1000
100
I F = 5.5A
I F = 11 A
I F = 22 A
VR = 2 0 0 V
TJ = 1 2 5 °C
TJ = 2 5 °C
100
100
d i f /d t - (A /µ s)
1000
Fig. 7 - Typical Stored Charge vs. dif/dt
4
10
100
1000
d i f /d t - (A /µ s )
Fig. 8 - Typical di(rec)M/dt vs. dif/dt
www.irf.com
HFA35HB120
3
t rr
IF
R E V E R S E R E C O V E R Y C IR C U IT
tb
ta
0
Q rr
VR = 200V
2
I RRM
4
0 .5 I R R M
d i(re c)M /d t
0.0 1 Ω
0 .7 5 I R R M
L = 7 0µ H
D .U .T .
d if/d t
ADJUST
D
G
5
IR F P 2 5 0
S
Fig. 9 - Reverse Recovery Parameter Test
Circuit
1
d i f /d t
1. dif/dt - Rate of change of current
through zero crossing
2. IRRM - Peak reverse recovery current
3. trr - Reverse recovery time measured
from zero crossing point of negative
going IF to point where a line passing
through 0.75 IRRM and 0.50 IRRM
extrapolated to zero current
4. Qrr - Area under curve defined by trr
and IRRM
trr X IRRM
Qrr =
2
5. di(rec)M/dt - Peak rate of change of
current during tb portion of trr
Fig. 10 - Reverse Recovery Waveform and
Definitions
WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, Tel: (310) 322 3331
IR GREAT BRITAIN: Hurst Green, Oxted, Surrey RH8 9BB, UK Tel: ++ 44 1883 732020
IR CANADA: 15 Lincoln Court, Brampton, Ontario L6T3Z2, Tel: (905) 453 2200
IR GERMANY: Saalburgstrasse 157, 61350 Bad Homburg Tel: ++ 49 6172 96590
IR ITALY: Via Liguria 49, 10071 Borgaro, Torino Tel: ++ 39 11 451 0111
IR FAR EAST: K&H Bldg., 2F, 30-4 Nishi-Ikebukuro 3-Chome, Toshima-Ku, Tokyo Japan 171 Tel: 81 3 3983 0086
IR SOUTHEAST ASIA: 1 Kim Seng Promenade, Great World City West Tower, 13-11, Singapore 237994 Tel: ++ 65 838 4630
IR TAIWAN:16 Fl. Suite D. 207, Sec. 2, Tun Haw South Road, Taipei, 10673, Taiwan Tel: 886-2-2377-9936
http://www.irf.com/
Data and specifications subject to change without notice.
6/99
www.irf.com
5