IRF HFA35HB60

PD-20379
HFA35HB60
HEXFRED
TM
Ultrafast, Soft Recovery Diode
Features
VR = 600V
(ISOLATED BASE)
• Reduced RFI and EMI
• Reduced Snubbing
• Extensive Characterization of Recovery Parameters
• Hermetic
• Electrically Isolated
• Ceramic Eyelets
VF = 1.75V
Qrr = 290nC
CATHODE
di(rec)M/dt = 400A/µs
ANODE
Description
TM
HEXFRED diodes are optimized to reduce losses and
EMI/RFI in high frequency power conditioning systems.
An extensive characterization of the recovery behavior
for different values of current, temperature and di/dt
simplifies the calculations of losses in the operating
conditions. The softness of the recovery eliminates the
need for a snubber in most applications. These devices
are ideally suited for power converters, motors drives and
other applications where switching losses are significant
portion of the total losses.
TO-254AA
Absolute Maximum Ratings (per Leg)
Parameter
VR
IF @ TC = 100°C
IFSM @ TC = 25°C
PD @ TC = 25°C
TJ
TSTG
D.C. Reverse Voltage
Continuous Forward Current 
Single Pulse Forward Current ‚
Maximum Power Dissipation
Operating Junction and
Storage Temperature Range
Max.
Units
600
22
225
83
-55 to +150
V
A
W
°C
Thermal - Mechanical Characteristics
Parameter
RθJC
Junction-to-Case, Single Leg Conducting
Weight
Typ.
Max.
Units
—
9.3
1.5
—
°C/W
g
Note:  D.C. = 50% rect. wave
‚ 1/2 sine wave, 60 Hz , P.W. = 8.33 ms
www.irf.com
1
6/30/99
HFA35HB60
Electrical Characteristics (per Leg) @ TJ = 25°C (unless otherwise specified)
Parameter
VBR
VFM
Min. Typ. Max. Units
Cathode Anode Breakdown Voltage
Max Forward Voltage
IRM
Max Reverse Leakage Current
CT
LS
Junction Capacitance
Series Inductance
600
—
—
—
—
—
—
—
—
—
—
—
—
—
56
8.7
—
1.75
2.25
1.64
10
1.0
59
—
Test Conditions
V
IR = 100µA
IF = 22A
IF = 45A
See Fig. 1
IF = 22A, TJ = 125°C
VR = VR Rated
See Fig. 2
TJ = 125°C, VR = 480V
VR = 200V
See Fig. 3
Measured from center of bond pad to
end of anode bonding wire
V
µA
mA
pF
nH
Dynamic Recovery Characteristics (per Leg) @ TJ = 25°C (unless otherwise specified)
Parameter
trr1
trr2
IRRM1
IRRM2
Qrr1
Qrr2
di(rec)M/dt1
di(rec)M/dt2
Min. Typ. Max. Units
Reverse Recovery Time
—
—
—
—
—
—
—
—
Peak Recovery Current
Reverse Recovery Charge
Peak Rate of Fall of Recovery Current
During tb
60
110
5.2
8.5
190
560
270
170
90
165
7.8
13
290
840
400
250
ns
A
nC
A/µs
Test Conditions
TJ = 25°C
See Fig.
TJ = 125°C
5
IF = 22A
TJ = 25°C
See Fig.
TJ = 125°C
6
VR = 200V
TJ = 25°C
See Fig.
TJ = 125°C
7
dif/dt = 200A/µs
TJ = 25°C
See Fig.
TJ = 125°C
8
Case Outline and Dimensions — TO-254AA
.12 ( .0 05 )
13 .84 ( .5 45 )
13 .59 ( .5 35 )
3 .7 8 ( .1 49 )
3 .5 3 ( .1 39 )
-A-
2 0.32 ( .80 0 )
2 0.07 ( .79 0 )
17.40 ( .68 5 )
16.89 ( .66 5 )
3 1.40 ( 1.23 5 )
3 0.39 ( 1.19 9 )
6.60 ( .260 )
6.32 ( .249 )
1
2
-B 1 .2 7 ( .0 50 )
1 .0 2 ( .0 40 )
1 3.84 ( .54 5 )
1 3.59 ( .53 5 )
L EGEN D
1 - C O L LE C TO R
- C-
3X
3.81 ( .15 0 )
2X
1.14 ( .045 )
0.89 ( .035 )
.50 ( .02 0 )
.25 ( .01 0 )
1 2 3
W
2 - E M ITT E R
3 - G A TE
3
3.81 ( .15 0 )
M C A M B
M C
N O TE S :
1 . D IM E N S IO NIN G & TO L E RA N C IN G P E R A N S I Y 1 4.5M , 1 982 .
2 . A L L D IM E N S IO N S A R E S HO W N IN M IL LIM E TE R S ( IN CH E S ).
LEGEND
1- DRAIN
2- SOURCE
3- GATE
LEGEND
1- DRAIN
2- SOURCE
3- GATE
Conforms to JEDEC Outline TO-254AA
Dimensions in Millimeters and ( Inches )
CAUTION
BERYLLIA WARNING PER MIL- PRF-19500
Package containing beryllia shall not be ground, sandblasted,machined, or have other operations performed on them
which will produce beryllia or beryllium dust. Furthermore, eryllium oxide packages shall not be placed in acids that will
produce fumes containing beryllium.
2
www.irf.com
HFA35HB60
R ev erse C u rre n t - I R (µ A )
1000
100
TJ = 1 50°C
TJ = 1 25°C
10
1
0.1
TJ = 25°C
0.01
TJ = -55°C
0.001
0.0001
0
10
200
400
600
R e ve rse V o lta g e - V R (V )
Fig. 2 - Typical Reverse Current vs. Reverse
Voltage
J un ctio n C a pa cita n ce - C T (pF )
Instantane ous Forward C u rrent - I F (A )
100
1000
T J = 1 50 °C
T J = 1 25 °C
1
1.0
2.0
TJ = 25°C
100
T J = 25 °C
0.0
A
3.0
4.0
Forward V olta ge D ro p - V FM (V )
Fig. 1 - Maximum Forward Voltage Drop
vs. Instantaneous Forward Current
10
1
10
100
1000
R ev ers e V olta ge - VR (V )
Fig. 3 - Typical Junction Capacitance vs.
Reverse Voltage
Thermal Response (Z thJC )
10
1
D = 0.50
0.20
0.10
0.1
P DM
0.05
0.02
0.01
0.01
0.00001
t1
t2
SINGLE PULSE
(THERMAL RESPONSE)
0.0001
Notes:
1. Duty factor D = t 1 / t 2
2. Peak TJ = P DM x Z thJC + TC
0.001
0.01
0.1
1
10
t1 , Rectangular Pulse Duration (sec)
Fig. 4 - Maximum Thermal Impedance Zthjc Characteristics
www.irf.com
3
HFA35HB60
100
150
I F = 44A
I F = 22A
120
I F = 44 A
I F = 11A
I F = 2 2A
Irr- ( A)
I F = 11 A
trr- (nC)
90
10
60
30
VR = 2 0 0 V
T J = 1 2 5 °C
TJ = 2 5 ° C
VR = 2 0 0 V
T J = 1 2 5 °C
T J = 2 5 °C
0
100
d i f /d t - (A /µs )
1
100
1000
1000
d i f /d t - (A /µ s )
Fig. 5 - Typical Reverse Recovery vs. dif/dt
Fig. 6 - Typical Recovery Current vs. dif/dt
10000
2000
VR = 2 0 0 V
T J = 1 2 5 °C
T J = 2 5 °C
VR = 2 0 0 V
T J = 1 2 5 °C
T J = 2 5 °C
di (rec) M/dt- (A /µs)
1600
Qrr- (nC)
I F = 44 A
1200
I F = 2 2A
I F = 1 1A
800
1000
I F = 2 2A
I F = 1 1A
400
I F = 4 4A
0
100
di f /dt - (A /µs)
1000
Fig. 7 - Typical Stored Charge vs. dif/dt
4
100
100
1000
d i f /d t - (A /µ s )
Fig. 8 - Typical di(rec)M/dt vs. dif/dt
www.irf.com
HFA35HB60
3
t rr
IF
R E V E R S E R E C O V E R Y C IR C U IT
tb
ta
0
Q rr
VR = 200V
2
I RRM
4
0 .5 I R R M
d i(re c)M /d t
0.0 1 Ω
0 .7 5 I R R M
L = 7 0µ H
D .U .T .
d if/d t
ADJUST
D
G
5
IR F P 2 5 0
S
Fig. 9 - Reverse Recovery Parameter Test
Circuit
1
d i f /d t
1. dif/dt - Rate of change of current
through zero crossing
2. IRRM - Peak reverse recovery current
3. trr - Reverse recovery time measured
from zero crossing point of negative
going IF to point where a line passing
through 0.75 IRRM and 0.50 IRRM
extrapolated to zero current
4. Qrr - Area under curve defined by trr
and IRRM
trr X IRRM
Qrr =
2
5. di(rec)M/dt - Peak rate of change of
current during tb portion of trr
Fig. 10 - Reverse Recovery Waveform and
Definitions
WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, Tel: (310) 322 3331
IR GREAT BRITAIN: Hurst Green, Oxted, Surrey RH8 9BB, UK Tel: ++ 44 1883 732020
IR CANADA: 15 Lincoln Court, Brampton, Ontario L6T3Z2, Tel: (905) 453 2200
IR GERMANY: Saalburgstrasse 157, 61350 Bad Homburg Tel: ++ 49 6172 96590
IR ITALY: Via Liguria 49, 10071 Borgaro, Torino Tel: ++ 39 11 451 0111
IR FAR EAST: K&H Bldg., 2F, 30-4 Nishi-Ikebukuro 3-Chome, Toshima-Ku, Tokyo Japan 171 Tel: 81 3 3983 0086
IR SOUTHEAST ASIA: 1 Kim Seng Promenade, Great World City West Tower, 13-11, Singapore 237994 Tel: ++ 65 838 4630
IR TAIWAN:16 Fl. Suite D. 207, Sec. 2, Tun Haw South Road, Taipei, 10673, Taiwan Tel: 886-2-2377-9936
http://www.irf.com/
Data and specifications subject to change without notice.
6/99
www.irf.com
5