POWERDYNAMICS HGN-367A01S-28-2JS

HGN-367A
FUSED WITH DISTANCE SWITCH, IEC 60320 POWER INLET SOCKET
WITH FUSE/S (5X20MM)
MECHANICAL DIMENSIONS (Unit: mm)
33
2x 3.6
4
31
20
49.5
36 44
28.3
H.S. TUBING
125 C, 600V
BLACK
FEATURES
18 AWG,
UL1015
105 C,
BLUE
18 AWG, UL1015
105 C, BROWN
31.0
The HGN-367A series line filters feature an IEC connector
with an integral fuse holder and distance switch; available
for one or two 5 x 20mm fuses. (IEC 601 prescribes fusing
both lines.) Fully enclosed metal housing prevents input of
high frequency noise and protects ultra-sensitive equipment.
These filters are also available for Medical equipment with
low leakage current.
20+- 3
51 42.6
A ground choke can be added to enhance the grounding
ability of the circuit. A bleeder resistor can also be added
to prevent excessive voltages from developing across the
filter capacitors when there is no load.
APPLICATIONS
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
36.0
TECHNICAL DATA
Filter
• Rated Voltage: 125/250VAC
• Rated Current: 1A, 2A, 3A, 4A, 6A, 8A, 10A
• Power Line Frequency: 50/60Hz
• Max. Leakage Current each
Line to Ground:
@ 250VAC 50Hz: 0.5mA
@ 250VAC 50Hz: 2µA*
• Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
• Temperature Range: -25C to +85C
Switch
• Rated Voltage: 250VAC
• Rated Current: 8A
• Temperature Range: -10C to +60C
• SPST
* Medical application
28.5
2x M3x0.5
20
RECOMMENDED
SWITCH LAYOUT
31.2 Typ.
2x
3.5
RECOMMENDED
PANEL CUTOUT
(MOUNTING FROM FRONT)
Specifications subject to change without notice. Dimensions (mm). See Appendix A for
recommended power cord. See PDI full line catalog for detailed specifications on power cords.
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: [email protected] • www.powerdynamics.com
73
HGN-367A Series Example & Ordering Code
HGN-367A 01
A
S
SCHEMATICS
1
L
L mH
Fuse
L'
R
Cy
CX
G'
L
Cy
N
LOAD
01
02
03
04
06
08
10
N'
Fuse
L mH
G
3.0 -3.6L
8.0
6.3/0.25
2.0 -3.0L
=Q
SOLDER
=S
2
L
L mH
Fuse
LINE
6.6
Lg
QUICK CONNECT
L'
R
N
L
CX
Cy
G'
Cy
LOAD
TERMINAL:
=
=
=
=
=
=
=
5 - 1
LINE
CURRENT RATING (A):
Q - 1
N'
Fuse
L mH
G
NO BLEEDER RESISTOR & NO GROUND CHOKE
BLEEDER RESISTOR (1/4 W, 1M)
BLEEDER RESISTOR (1/2 W, 1M)
BLEEDER RESISTOR (1/4 W, 1M) & GROUND CHOKE
BLEEDER RESISTOR (1/2 W, 1M) & GROUND CHOKE
GROUND CHOKE (100µH)
COMPONENT LOCATIONS:
=
=
=
=
=
=
3
0
5
6
7
8
9
L
1A (mH)
6.5
1.9
3.7
*
4.6
9.5
6.5
10.5
5.0
TYPE OF MOUNTING:
74
4A (mH) 6A (mH)
1.6
0.8
0.8
0.6
1.3
*
1.7
*
1.4
6.0
1.2
0.85
2.0
0.8
0.9
0.53
1.1
0.6
N'
Lg
STANDARD TYPE
WITH C(X) & C(Y) BEHIND L
WITHOUT C(X); C(Y) ONLY
WITHOUT C(Y); C(X) ONLY
WITHOUT C(Y); C(X) BEHIND L
=
=
=
=
=
1
2✢
3✢
1M
2M✢
MEDICAL
SCHEMATICS
1M
=A
=B
=C
=D
=E
=F
=G
=H
=I
=J
=K
8A (mH)
1.05
*
*
*
*
*
1.05
*
*
10A (mH)
0.2
0.3
0.3
*
0.3
0.3
0.3
*
0.2
L
L'
R
CX
L
N
N'
Fuse
L mH
G
G'
Lg
2M
L
M1
M2
M3
M4
M5
M6
M7
M8
M9
= BLANK
FLANGE MOUNT
* VDE submitted
=T
SNAP-IN TABS - TOP BOTTOM
=S
SNAP-IN TABS - SIDE
L mH
Fuse
L'
R
N
=
=
=
=
=
=
=
=
=
L mH
Fuse
LINE
1A (mH) 2A (mH) 3A (mH) 4A (mH) 6A (mH) 8A (mH) 10A (mH)
6.5
3.8
2.5
1.6
0.8
1.05
0.2
1.9
1.5
1.1
0.8
0.6
*
0.3
3.7
2.7
1.8
1.3
0.8
1.05
0.3
10.5
4.2
2.5
1.7
1.05
*
0.3
4.6
3.4
2.5
1.4
0.9
*
0.3
9.5
4.3
1.8
1.2
0.85
*
0.3
6.5
4.0
2.5
2.0
0.85
1.05
0.3
6.5
4.0
2.5
2.0
0.85
1.05
0.3
10.5
4.0
1.2
0.9
0.53
*
0.3
5
3.7
1.8
1.1
0.6
*
0.2
10.5
6.5
2.5
2.7
1.05
*
0.3
2A (mH) 3A (mH)
3.8
2.5
1.5
1.1
2.7
1.8
4.2
*
3.4
2.5
4.3
1.8
4.0
2.5
4.0
1.2
3.7
*
Cy
L mH
G
Medical applications, select Attenuation code with corresponding component values from the table.
Cap C(x)
0.1µF
0.015µF
0.1µF
0.1µF
0.047µF
0.033µF
0.22µF
0.047µF
0.033µF
G'
L
Fuse
LINE
Cap C(y)
2200pF
3300pF
3300pF
1000pF
3300pF
3300pF
2200pF
3300pF
2200pF
2200pF
*
L'
Cy
R
N
ATTENUATION CODE TABLE:
Non-Medical applications, select Attenuation code with corresponding component values from the table.
Cap C(x)
0.1µF
0.015µF
0.1µF
0.1µF
0.047µF
0.033µF
0.22µF
0.22µF
0.047µF
0.033µF
*
L mH
Fuse
LOAD
OPTIONS:
Lg
Fuse
G
L
LOAD
2 FUSE (5X20MM)
=1
= 2✝
LOAD
1 FUSE (5X20MM)
LINE
FUSE OPTION:
CX
N'
L mH
G'
Lg
Contact PDI for attenuation numbers
Flange mount only
*Contact PDI for availability
✢
✝
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: [email protected] • www.powerdynamics.com