MEANWELL HLG-240-36A

HLG-240
240W Single Output Switching Power Supply
series
Features :
Universal AC input / Full range
Built-in active PFC function
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potential meter
Suitable for LED lighting and moving sign applications
IP67 / IP65 design for indoor or outdoor installations
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
3 years warranty
110
F
HLG-240-12 A
SELV
IP65 IP67
Blank : IP67 rated. Cable for I/O connection.
A : IP65 rated. Output voltage and constant current level can be adjusted through internal potential meter.
B : IP67 rated. Constant current level adjustable through output cable.
C : Terminal block for I/O connection. Output voltage and constant current level can be adjusted through internal
potential meter.
SPECIFICATION
MODEL
HLG-240-12
HLG-240-15
12V
DC VOLTAGE
CONSTANT CURRENT REGION Note.4 6 ~12V
OUTPUT
HLG-240-30
HLG-240-36
HLG-240-42
HLG-240-48
HLG-240-54
42V
15V
20V
24V
30V
36V
48V
54V
7.5 ~ 15V
10 ~ 20V
12 ~ 24V
18 ~ 36V
21 ~ 42V
24 ~ 48V
27 ~ 54V
6.7A
5.72A
5A
4.45A
RATED CURRENT
16A
15A
12A
10A
RATED POWER
192W
225W
240W
240W
240W
241.2W
240.2W
240W
240.3W
RIPPLE & NOISE (max.) Note.2 150mVp-p
150mVp-p
150mVp-p
150mVp-p
200mVp-p
250mVp-p
250mVp-p
250mVp-p
350mVp-p
VOLTAGE ADJ. RANGE Note.6 11.2 ~ 12.8V
14 ~ 16V
18.6 ~ 21.4V 22.4 ~ 25.6V 28 ~ 32V
33.5 ~ 38.5V 39 ~ 45V
44.8 ~ 51.2V 50 ~ 57V
Can be adjusted by internal potential meter or through output cable
CURRENT ADJ. RANGE
8 ~ 16A
2.86 ~ 5.72A 2.5 ~ 5A
1.0%
1.0%
5 ~ 10A
4 ~ 8A
2.5%
2.0%
1.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
2.0%
1.5%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
VOLTAGE RANGE
7.5 ~ 15A
3.3 ~ 6.7A
6 ~ 12A
VOLTAGE TOLERANCE Note.3
Note.8 2500ms, 80ms at full load
15ms at full load
HOLD UP TIME (Typ.)
Note.5 90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR
PF 0.95/230VAC
EFFICIENCY (Typ.)
90%
AC CURRENT
INRUSH CURRENT (Typ.)
OVER CURRENT
Note.4
SHORT CIRCUIT
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
2.23 ~ 4.45A
1.0%
230VAC /115VAC
230VAC /115VAC
127 ~ 373VDC
PF 0.98/115VAC at full load and rated output voltage
92%
90%
4A / 115VAC
2A / 230VAC
COLD START 75A/230VAC
93%
93%
93.5%
PF 0.9 at 65 ~ 100% load
94%
94%
94%
53 ~ 62V
59 ~ 65V
<0.75mA / 240VAC
LEAKAGE CURRENT
PROTECTION
HLG-240-24
15 ~ 30V
8A
SETUP, RISE TIME
INPUT
HLG-240-20
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed.
32.5 ~ 36.5V 40 ~ 48V
26 ~ 33V
13.5 ~ 16V
16.5 ~ 19.5V 22 ~ 26V
46 ~ 50V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
105
5
95
(TSW1)
5
(TSW1)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-30 ~ +60
@ full load ; +70 @ 60% load (Refer to derating curve)
20 ~ 95% RH non-condensing
-40 ~ +80
0.03%/
, 10 ~ 95% RH
(0 ~ 50
)
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS Note.7 UL1012, TUV EN61347-1, EN61347-2-13 independent (except for HLG-240H C type), UL60950-1, UL8750, TUV EN60950-1, IP65 or IP67 approved
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMC
EMI CONDUCTION & RADIATION Compliance to EN55015, EN55022 (CISPR22) Class B
Compliance to EN61000-3-2 Class C ( 50% load) ; EN61000-3-3
HARMONIC CURRENT
EMS IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
NOTE
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, heavy industry level (surge 4KV), criteria A
207.9Khrs min. MIL-HDBK-217F (25 )
244.2*68*38.8mm (L*W*H)(HLG-240-Blank/A/B)
251*68*38.8mm (L*W*H)(HLG-240-C)
1.3Kg; 12pcs/16.6Kg/0.74CUFT(HLG-240-Blank/A/B)
1.23Kg; 12pcs/15.8Kg/1.16CUFT(HLG-240-C)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Type A and type C only.
7. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
HLG-240
240W Single Output Switching Power Supply
Mechanical Specification
Case No.954C
series
Unit:mm
Blank:(HLG-240)
244.2
220.2
12
9.4
9.6
300 20
+V(Red)
-V(Black)
34.2
68
300 20
2
2
SJTW 18AWG(0.75mm ) 3C
SJTW 14AWG(1.5mm ) 2C
9.4
AC/L(Brown)
AC/N(Blue)
FG (Green/Yellow)
38.8
4.2 4PL
IP67 rated. Cable for I/O connection.
A Type:(HLG-240-_A)
244.2
220.2
12
9.4
9.6
34.2
68
300 20
2
SJTW 18AWG(0.75mm ) 3C
300 20
Vo Io
ADJ. ADJ.
+V(Red)
-V(Black)
2
SJTW 14AWG(1.5mm ) 2C
4.2 4PL
38.8
9.4
AC/L(Brown)
AC/N(Blue)
FG (Green/Yellow)
IP65 rated. Output voltage and constant current level can be adjusted through internal potential meter.
(Can access by removing the rubber stopper on the case.)
File Name:HLG-240-SPEC 2010-06-14
HLG-240
240W Single Output Switching Power Supply
series
B Type:(HLG-240-_B)
244.2
220.2
12
9.6
9.4
2
SJTW 14AWG(1.5mm ) 2C
2
SJTW 18AWG(0.75mm ) 3C
2
SJTW 18AWG(0.75mm ) 2C
4.2 4PL
+V(Red)
-V(Black)
ADJ1(Blue)
ADJ2(White)
38.8
9.4
AC/L(Brown)
AC/N(Blue)
FG (Green/Yellow)
300 20
34.2
68
300 20
IP67 rated. Output constant current level can be adjusted through output cable by connecting a resistor between ADJ1 and ADJ2.
Reference resistance value for output current adjustment (Typical)
Model
12V
15V
20V
24V
30V
36V
42V
48V
54V
Open
Open
Open
Open
Open
Open
Open
Open
Open
75%
680
560
680
510
820
1.8K
680
620
820
50%
120
47
91
51
120
500
82
68
150
Slightly < 50%
Short
Short
Short
Short
Short
Short
Short
Short
Short
Percentage
of rated current
Slightly > 100%
C Type:(HLG-240-_C)
251
220.2
15.4
8
1
3
68
1
37
2
Vo Io
ADJ. ADJ.
2
O/P
8
4.2 4PL
Pin No.
1
2
3
Assignment
FG
AC/L
AC/N
DC Output Terminal Pin No.
Assignment
38.8
7.5
I/P
9.5
8
AC Input Terminal Pin No.
Assignment
Pin No.
1
2
Assignment
-V
+V
Output voltage and constant current level can be adjusted through internal potential meter.
(Can access by removing the rubber stopper on the case.)
File Name:HLG-240-SPEC 2010-06-14
HLG-240
240W Single Output Switching Power Supply
series
Block Diagram
Fosc : 100KHz
EMI FILTER
&
RECTIFIERS
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
PFC
CIRCUIT
+V
-V
ADJ1
ADJ2
(B Type)
O.L.P.
FG
O.L.P.
DETECTION
CIRCUIT
PWM & PFC
CONTROL
PFC
CONTROL
O.V.P.
Derating Curve
Static Characteristics
fosc : 100KHz
230VAC
100
100
90
80
80
100VAC
70
LOAD (%)
LOAD (%)
60
40
20
-30
-25
-10
0
15
30
50
60
(HORIZONTAL)
70
60
50
40
90
100
125
AMBIENT TEMPERATURE ( )
135
145
155 165
175
180
200
230
264
INPUT VOLTAGE (V) 60Hz
Power Factor Characteristic
Power factor will be higher than 0.9 when output loading is 65% or higher.
PF
Constant Current Mode
1 .0 2
1
0 .9 8
0 .9 6
0 .9 4
0 .9 2
0 .9
0 .8 8
0 .8 6
0 .8 4
0 .8 2
0 .8
110V
30%
40%
50%
60%
70%
80%
90%
230V
100%
LOAD
EFFICIENCY vs LOAD (48V Model)
HLG-240 series possess superior working efficiency that up to 94% can be reached in field applications.
96
94
EFFICIENCY (%)
92
90
88
86
110V
230V
84
82
80
78
76
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
LOAD
File Name:HLG-240-SPEC 2010-06-14
HLG-240
240W Single Output Switching Power Supply
series
DRIVING METHODS OF LED MODULE
There are two major kinds of LED drive method "direct drive" and "with LED driver".
A typical LED power supply may either work in "constant voltage mode (CV) or constant current mode (CC)" to drive the LEDs.
Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode (with LED driver, at area (A) and CC mode (direct drive, at area (B).
(B)
Constant
Current area
Vo(%)
100
(A) Constant
Voltage area
50
(max.)
(C)
Hiccup
Protection
50
95
Io (%)
Typical LED power supply I-V curve
~
~
Direct driving :
Under direct driving, the power supply will work in "constant current mode (CC)" and output voltage of the power supply will be clamped by sum of
forward voltage (V F ) of the LED strip.
The total forward voltage of series connecting LEDs is suggested for 75%~95% of power supply rated output voltage due to concern of the best PF
value and efficiency.
AC
source
I/P
HLG-240
O/P
AC
source
I/P
~
~
With LED driver
Using additional driver, the power supply will work in "constant voltage mode (CV)" and output voltage of the power supply will be kept in rated value.
In this drive mode, several design issues need to be considered:
1.Output voltage of PSU must be higher than total forward voltage of series connecting LEDs by 3V minimum.
2.Input capacitor (Cin) of LED driver circuit should use 2.2uF ~ 22uF(typ.) of rating depends on the operating frequency of the LED driver.
The higher the operating frequency is used, the smaller value of Cin should be chosen, and vice versa.
HLG-240
O/P
R
Cin
Cout
VF
L
IC Circuit
File Name:HLG-240-SPEC 2010-06-14
HLG-240
240W Single Output Switching Power Supply
series
EMI DEBUG SUGGESTION
Chassis of LED Lamp
C
~
~
LED CC driver
AC
source
I/P
HLG-240
CC
IC
O/P
FG
B
A
D
A
A. Add a common mode ferrite choke on output wires to reduce the common emission between 10M ~ 300MHz per lighting EMI regulation.
B. Chassis of LED lamp and chassis of HLG-240 or the FG wire should be connected to the safety ground to reduce the EMI noise, including the conduction
and radiation emission.
C. The additional X-Cap and discharge resistor can reduce the low frequency conduction noise between 9K ~ 1MHz per lighting EMI regulation.
D. L-C filter should be added at the DC input of LED constant current driver to avoid the differential emission and high frequency noise generated by the
CC driver.
WATERPROOF CONNECTION
Waterproof connector
Waterproof connector can be assembled on the output cable of HLG-240 to operate in wet/damp or outdoor environment.
AC
source
HLG-240
I/P
Size
O/P
Pin Configuration (Female)
M12
Order No.
Suitable Current
4-PIN
5A/PIN
M12-04
10A max.
5-PIN
5A/PIN
M12-05
10A max.
Size
Pin Configuration (Female)
M15
2-PIN
12A/PIN
M15-02
12A max.
Order No.
Suitable Current
LED Lamp
Cable Joiner
Suitable for 14AWG~22AWG
20
25
66
26
Up to four wires can be connected through this cable joiner by
soldering or clamping by tools.
LED Lamp
HLG-240
O/P Wires
File Name:HLG-240-SPEC 2010-06-14