MACOM 2-1393127-3

General Purpose Relays
Industrial Relays
Potter & Brumfield
PRD Series Power Relay
n
Contact ratings to 50 amps
Magnetic blowouts available for switching DC loads
n Contact arrangement up to 2 form C (2CO)
n 1 Form C auxiliary switch available
n UL class B insulation
n
Typical applications
Industrial controls, lighting
Approvals
UL E22575; CSA LR15734; VDE Reg.Nr.C144
Models with all screw terminals are UL Listed. Others are UL Recognized.
Technical data of approved types on request
Contact Data
Contact arrangement 1 and 2 Form A (NO); 1 and 2 Form C (CO);
1 Form X (NO-DM)
Rated voltage
600VAC,125VDC
Rated current
50A
Contact material
Ag, AgCdO, W
Min. recommended contact load 1A, 12VDC or 12VAC
Initial contact resistance
75mΩ Max
Initial voltage drop
75mV
Frequency of operation
7200 ops/hr
Operate/releases time max.
40/20ms
Bounce time max.
10ms
Contact ratings (continued)
Type
Load
UL 508 1)
Models with screws or quick connects for main terminals
Code F, AgCdO, 1 pole
50A, 240VAC, general purpose 2)
30A, 277VAC, resistive
1.5HP, 120VAC 2HP, 250VAC
10A, 600VAC
Code F, AgCdO, 2 pole
50A, 240VAC, general purpose 2)
30A, 240VAC
20A, 277VAC
1.5HP, 120VAC
2HP, 250VAC
10A, 600VAC
Cycles
20x103
100x103
100x103
100x103
100x103
20x103
100x103
100x103
100x103
100x103
100x103
2) In order to achieve 50A rating with Contact Code F, Termination Code 0 or A is required.
Contact ratings
Type
Load
UL 508 1)
Models with screws or quick connects for main terminals
Code Y, Ag, 1 pole
25A, 277VAC
1HP, 120VAC 2HP, 250VAC
10A, 600VAC
7A, 50VDC, resistive
Code Y, Ag, 2 pole
25A, 240VAC
20A, 277VAC
1HP, 120VAC
2HP, 250VAC
7A, 50VDC, resistive
10A, 600VAC
Code G, AgCdO, 1 pole
30A, 277VAC, resistive
1.5HP, 120VAC
2HP, 250VAC
10A, 600VAC
Code G, AgCdO, 2 pole
30A, 240VAC
20A, 277VAC
1.5HP, 120VAC
2HP, 250VAC
10A, 600VAC
Cycles
100x103
100x103
100x103
100x103
100x103
100x103
100x103
100x103
100x103
100x103
100x103
100x103
100x103
100x103
100x103
100x103
100x103
100x103
100x103
100x103
Code H, Ag with magnetic blowout, 1 or 2 pole
20A, 125VDC
1/3HP, 125VDC Code J, AgCdO with magnetic blowout, 1 or 2 pole
20A, 125VDC
1/3HP, 125VDC Code N, W stationary with AgCdO movable, 1 or 2 pole
25A, 250VAC
1HP, 125VAC
2HP, 250VAC
UL 508 1)
Models with box lugs for main terminals
Code P, Ag, 1 form X
50A, 277VAC, general purpose
30A, 277VAC, ballast
15A, 277VAC, tungsten 102LRA, 17FLA, 240VAC
120LRA, 20FLA, 120VAC
1.5HP, 120VAC
3HP, 240VAC
Factory ratings
Models with box lugs for main terminals
Code R, Ag with magnetic blowout, 1 form X
60A, 28VDC, resistive
30A, 125VDC
Mechanical endurance
100x103
100x103
100x103
100x103
100x103
100x103
100x103
100x103
6x103
6x103
30x103
30x103
30x103
30x103
100x103
100x103
DC Coil, 1x106 ops.; AC Coil 5x105 ops.
1) Any PRD relay deviating electrically or physically from the standard models in the table is
not UL or CSA listed. All horsepower ratings are for single phase motors..
Auxiliary Snap-Action Switch Contact Data
Contact arrangement
Rating Contact material
08-2011, Rev. 0811
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
1 Form C (CO)
5A, 120VAC, 60 Hz., 25°C
Ag
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
1
General Purpose Relays
Industrial Relays
Potter & Brumfield
PRD Series Power Relay (Continued)
Coil Data
Coil voltage range
6 to 110VDC
6 to 480VAC
Coil insulation system according UL
Class B
Coil versions, DC coil
Coil
Rated
Operate
Release
Coil
code
voltage
voltage
voltage
resistance
VDC
VDC
VDC
Ω±10%
6
6
4.5
0.6
18
12
12
9
1.2
71
24
24
18
2.4
288
48
48
36
4.8
1150
110
110
82.5
11
6050
Insulation Data
Initial dielectric strength
between open contacts
between contact and coil
between adjacent contacts
Initial insulation resistance
between insulated elements
Rated coil
power
W
2
2
2
2
2
Release
voltage
VAC
0.6
1.2
2.4
12
24
48
Coil
resistance
Ω±15%
0.86
3.2
12
290
1200
4500
100MΩ
Other Data
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
refer to the Product Compliance Support Center at
www.te.com/customersupport/rohssupportcenter
Ambient temperature
AC coil: -55ºC to 45ºC
DC coil: -55°C to 80°C
Category of environmental protection
IEC 61810
RT0 - open relay
Terminal type
Screw, Quick connects, Box lugs
Weight
284g
Packaging/unit
tray/20 pcs., box/40pcs.
All figures are given for coil without preenergization, at ambient temperature +23°C.
Other coil voltages on request.
Coil versions, AC coil
Coil
Rated
Operate
code
voltage
voltage
VAC
VAC
6
6
5.1
12
12
10.2
24
24
20.4
120
120
102
240
240
204
480
480
408
2000Vrms
2000Vrms
2000Vrms
Rated coil
power
VA
9.8
9.8
9.8
9.8
9.8
9.8
Accessories
Product Code Description
35D013 Metal dust cover
All figures are given for coil without preenergization, at ambient temperature +23°C.
Other coil voltages on request.
Dimensions
PRD/PRDA 1, 3, 5 and 7
PRD/PRDA 11
2.5 MAX.
(63.3)
.81
(20.6)
.875 MAX.
(22.23)
4
2
.31
(7.9)
1
3.375 MAX.
(85.73)
4
6
2.51 MAX.
(63.75)
COIL
3
.875 MAX.
(22.23)
PRD-3_P and R
2
2.51 MAX. 2.50
(63.5)
(63.8)
1.875
1.875
(47.63)
(47.63)
5
1
(
)
)
)
6
COIL
1
2 MTG. HOLES
DIA.
.187 + .005
– .003
4.75 + .13
– .08
2 MTG. HOLES
DIA.
.187 + .005
– .003
4.75 + .13
– .08
(
2
8
7
3
(
6
COIL
1.875
(47.63)
5
.31
(7.9)
1.687
(42.85)
2 MTG. HOLES
DIA.
.187 + .005
– .003
4.75 + .13
– .08
.31
(7.9)
BOX LUG
CONNECTOR
5
.81
(20.6)
.59 MAX.
(15.0)
2.5 MAX.
(64)
2.28 MAX.
(57.9)
2.50 MAX.
(63.5)
2.50 MAX. ON PRD7
(63.5)
.375
(9.53)
2.23
3.375 (56.6)
(85.73)
2.5 MAX.
(63.5) W/O AUX SWITCH
2
08-2011, Rev. 0811
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
3.00
.375
4.250 MAX. (76.2)
(9.53)
(107.95)
3.375 MAX. W/O AUX SWITCH
(85.73)
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
2.28 MAX.
(57.9)
.375
(9.53)
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
General Purpose Relays
Industrial Relays
Potter & Brumfield
PRD Series Power Relay (Continued)
Terminal assignment for models with magnetic blowout
PRD3 with blowout
PRD7 with blowout PRD 11 with blowout
THIS SIDE OF MAGNET
ATTRACTS NORTH SEEKING
POLE OF COMPASS.
THIS SIDE OF MAGNET
ATTRACTS NORTH SEEKING
POLE OF COMPASS.
-
-
+
POLARITY
MARKING
THIS SIDE OF MAGNET
ATTRACTS NORTH SEEKING
POLE OF COMPASS.
-
+
POLARITY
MARKING
POLARITY
MARKING
Product code structure
-
Typical product code
PRD
-7
A
Y
0
-120
Type
PRD Open relay
PRDA Open relay with aux. 1 form C (CO) snap-action switch
Main contact arrangement
1 1 form A (1 NO)
3 1 form X (1 NO-DM)
5 1 form C (1 CO) 7 2 form A (2 NO)
7V 2 form A (2 NO) with 3mm contact gap 1)
11 2 form C (2 CO)
1) Code 7V is only available as a UL Recognized model, not UL Listed
Coil input
A AC, 50/60Hz
D DC
Main contact material and type
Y .312” (7.92mm) dia. Ag [25A max. rating]
G .312” (7.92mm) dia. AgCdO [30A max. rating]
F .312” (7.92mm) dia. AgCdO [50A max. rating] 2)
H Ag with magnetic blowout [20A DC max. rating] 3)
J AgCdO with magnetic blowout [20A DC max. rating]
N W stationary & AgCdO movable [25A max. rating] 4)
P Ag [50A max. rating] 5)
R Ag with magnetic blow out [50A max. rating] 5)
2) Available with Main contact arrangement code (step 2 above) 1, 5, 7 or 11 only, and Termination code (step 5 below) 0 or A only.
3) Available with Main contact arrangement code (step 2 above) 3, 7 or 11 only
4) Available with Main contact arrangement code (step 2 above) 1, 5, 7 or 11 only.
5) Available with Main contact arrangement code (step 2 above) 3 only, and Termination code (step 5 below) 4 only.
Termination
PRD types only
0 #8-32 screw term. for main contacts, #6-32 screw term. for coil.
1 .250” (6.35mm) QC for main contacts and coil
3 #8-32 screw term. for main contacts, .250” (6.35mm) QC for coil.
4 Box lug term. which accept #6 - #14 wire for main contacts, #6-32 screw term. for coil. 6)
6) Available with Main contact arrangement code (step 2 above) 3 only, and Main contact material code (step 4 above) P or R only.
PRDA (with aux. switch) types only
A #8-32 screw term. for main contacts, #6-32 screw term. for coil, screw term. for aux. switch
B .250” (6.35mm) QC for main contacts, coil and aux. switch
L Twin .250” (6.35mm) QC for main contacts, .250” (6.35mm) QC for coil and aux. switch
Coil voltage
Coil code: please refer to coil versions table
08-2011, Rev. 0811
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
3
General Purpose Relays
Industrial Relays
Potter & Brumfield
PRD Series Power Relay (Continued)
Product Code
Arrangement
Material
Coil
Terminals
Part Number
PRD-3AY0-120
PRD-3AG0-120
PRD-3AJ0-120
PRD-3AJ3-24
PRD-3DH0-24
PRD-3DY0-12
PRD-3DY0-24
PRD-3DY0-110
PRD-5AY0-24
PRD-5AY0-120
PRD-5AY1-120
PRD-5AY0-240
PRD-5DF0-12
PRD-5DY0-12
PRD-5DY0-24
PRD-7AG0-120
PRD-7AY0-24
PRD-7AY0-120
PRD-7AY0-240
PRD-7AY3-120
PRD-7DG0-24
PRD-7DH0-48
PRD-7DY0-12
PRD-7DY0-24
PRD-11AF0-240
PRD-11AG0-24
PRD-11AG0-120
PRD-11AG0-240
PRD-11AH0-120
PRD-11AY0-24
PRD-11AY0-120
PRD-11AY0-240
PRD-11AY0-480
PRD-11DF0-12
PRD-11DF0-110
PRD-11DG0-12
PRD-11DG0-24
PRD-11DH0-12
PRD-11DH0-24
PRD-11DH0-48
PRD-11DH0-110
PRD-11DJ0-24
PRD-11DY0-12
PRD-11DY0-24
PRD-11DY0-48
PRD-11DY0-110
PRDA-11AGA-120
PRDA-11AYA-120
1 form X, 1 NO-DM
Ag
AgCdO, 30A
AgCdO, mag blowout
120VAC
Screw
24VAC
24VDC
12VDC
24VDC
110VDC
24VAC
120VAC
Screw / QC
Screw
7-1393127-9
6-1393127-9
7-1393127-4
7-1393127-5
8-1393127-6
9-1393127-5
9-1393127-6
9-1393127-4
1393128-6
1393128-5
1-1393128-1
1393128-7
2-1423100-4
1-1393128-6
1-1393128-7
9-1393129-5
1393130-9
1393130-7
1-1393130-0
1-1393130-2
1-1393130-6
2-1393130-1
2-1393130-8
2-1393130-9
3-1423100-0
1-1393127-1
1393127-9
1-1393127-2
1-1393127-6
2-1393127-9
2-1393127-6
3-1393127-0
3-1393127-1
2-1423100-2
2-1423100-9
3-1393127-5
3-1393127-8
4-1393127-7
4-1393127-9
5-1393127-0
4-1393127-6
5-1393127-5
6-1393127-1
6-1393127-2
6-1393127-3
6-1393127-0
7-1393131-4
7-1393131-9
Ag, mag blowout
Ag
1 form C, 1 CO
AgCdO, 50A
Ag
2 form A, 2 NO
24VDC
120VAC
24VAC
120VAC
240VAC
120VAC
24VDC
48VAC
12VDC
24VDC
240VAC
24VAC
120VAC
240VAC
120VAC
24VAC
120VAC
240VAC
480VAC
12VDC
110VDC
12VDC
24VDC
12VDC
24VDC
48VDC
110 VDC
24 VDC
12 VDC
24 VDC
48 VAC
110 VDC
120 VAC
AgCdO, 30A
Ag
AgCdO, 30A
Ag, mag blowout
Ag
2 form C, 2 CO
QC
Screw
240VAC
12VDC
AgCdO, 50A
AgCdO, 30A
Ag, mag blowout
Ag
AgCdO, 50A
AgCdO, 30A
Ag, mag blowout
AgCdO, mag blowout
Ag
AgCdO, 30A
Screw / QC
Screw
PRD accessory
Product Code
Description
35D013
Part Number
Metal dust cover enclosure
35D013 Dust Cover
PRD dust cover has a steel base
with knockouts for 0.5” (12.7mm) dia.
conduit and a cover fitted with two
screws. Fits PRD relays, except with
auxiliary contacts. Finished in gray
baked enamel.
Mounting:
Three No. 10 holes on
1.875” (47.63mm) x
4.125” (104.77mm)
centers.
5-1393158-2
5.31 MAX.
(134.9)
4.125
(104.77)
.687
2.06
(17.45)
(52.3)
.50
(12.7)
1.875
(47.63)
.093
(2.36)
1.625
(41.28)
.937
(23.86)
.218 DIA.
(5.54)
3 MTG. HOLES
2.56
(65.0)
1.50
(38.1) .75
(19.1)
08-2011, Rev. 0811
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
3.38 MAX.
(85.9)
.812
(20.62)
5.125
(130.18)
.88 DIA. KNOCKOUT HOLES
(22.4)
2 KNOCKOUT HOLES EACH END
4
4 HOLES TAPPED #8-32
Note: Additional unused holes may be present in dust cover base.
4
3.13 MAX.
(79.5)
.97
(24.64)
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.