General Purpose Relays Force Guided Relays SCHRACK Force Guided Relay SR4 D/M n4 pole relay with force guided contacts according to EN 50205 design & space efficient nCompact Typical applications Emergency shut-off, press control, machine control, elevator and escalator control, safety relays F0244-C ZT Approvals Coil Data (continued) Technical data of approved types on request Coil versions, DC-coil Coil Rated Operate Release Coil Rated coil codevoltagevoltagevoltage resistancepower VDCVDCVDC Ω±10% mW 0212116.0 2.1551800 0242418.0 2.4720800 036 36 27.0 3.61620800 040 40 30.0 4.02000800 048 48 36.0 4.82880800 060 60 45.0 6.04500800 085 85 63.8 8.59031800 110 110 83.0 11.015125800 VDE 40005334, UL E214025, TUV 968/EL 230, CQC 06017015578 Contact Data Contact arrangement 3 form A + 1 form B contacts 3 NO + 1 NC 2 form A + 2 form B contacts 2 NO + 2 NC Rated voltage 250VAC Max. switching voltage 400VAC Rated current 8A Contact material AgSnO2 Contact style single contact, force guided type A according to EN 50205 Min. recommended contact load 5V/10mA Initial contact resistance ≤100mΩ at 1A, 24VDC ≤20Ω at 10mA, 5VDC Frequency of operation, with/without load 6/150min-1 Contact ratings, IEC60947-5-1, on 1 form A (NO) contact AC15-3A DC13-3A Mechanical endurance 10x106 operations All figures are given for coil without pre-energization, at ambient temperature +23°C. Insulation Data Coil data Coil voltage range 5 to 110VDC Coil versions, DC-coil Coil Rated Operate Release Coil Rated coil codevoltagevoltagevoltage resistancepower VDCVDCVDC Ω±10% mW 0055 3.80.531806 0066 4.50.645800 009 9 6.8 0.9101802 01212 9.0 1.2180800 0151511.3 1.5281801 0181813.5 1.8405800 10-2012, Rev. 1012 www.te.com © 2012 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Initial dielectric strength between open contacts 1500Vrms between contact and coil 4000Vrms between adjacent contacts 2500Vrms Clearance/creepage between open contacts microdisconnection between contact and coil ≥10/10mm between adjacent contacts ≥3/3.5mm Insulation to EN 50178, type of insulation between contact and coil reinforced between adjacent contacts basic Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change. 1 General Purpose Relays Force Guided Relays SCHRACK Force Guided Relay SR4 D/M (Continued) Other Data Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content refer to the Product Compliance Support Center at www.te.com/customersupport/rohssupportcenter Ambient temperature -25 to 70°C Category of environmental Protection IEC 61 810 RTIII Weight30g Resistance to soldering heat THT IEC 60068-2-20 260°C/5s Packaging/unit tube/10 pcs. For more detailed information see product specification 2158002 PCB layout / terminal assignment Bottom view on solder pins S0413-BC 2 form A + 2 form B, 2 NO + 2 NC contacts S0413-BB Dimensions 3 form A + 1 form B, 3 NO + 1 NC contacts S0413-BA S0412-BH Product code structure Typical product code SR4D 4 012 Type SR4 Relay with force guided contacts SR4 Contact arrangement D 2 form A + 2 form B contacts (2 NO + 2 NC) M 3 form A + 1 form B contacts (3 NO + 1 NC) Contact material 4 AgSnO2 Coil Coil code: please refer to coil versions table (e.g. 012=12VDC) Other types on request 2 10-2012, Rev. 1012 www.te.com © 2012 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change. General Purpose Relays Force Guided Relays SCHRACK Force Guided Relay SR4 D/M (Continued) Product code Type Contact arrangement Contact material Coil Part number SR4D4005 4 pole 2 form A + 2 form B, AgSnO2 5VDC7-1415054-1 SR4D4006 relay with 2 NO + 2 NC 6VDC 8-1415054-1 SR4D4009 force guided contacts contacts 9VDC 9-1415054-1 SR4D4012 12VDC 1415055-1 SR4D4018 18VDC 1-1415055-1 SR4D4021 21VDC 2-1415055-1 SR4D4024 24VDC 3-1415055-1 SR4D4036 36VDC 4-1415055-1 SR4D4040 40VDC 5-1415055-1 SR4D4048 48VDC 6-1415055-1 SR4D4060 60VDC 7-1415055-1 SR4D4085 85VDC 8-1415055-1 SR4D4110 110VDC 9-1415055-1 SR4M4005 3 form A + 1 form B, 5VDC 5-1415053-1 SR4M4006 3 NO + 1 NC 6VDC 6-1415053-1 SR4M4009contacts9VDC 7-1415053-1 SR4M4012 12VDC 8-1415053-1 SR4M4018 18VDC 9-1415053-1 SR4M4021 21VDC 1415054-1 SR4M4024 24VDC 4-1415053-1 SR4M4036 36VDC 1-1415054-1 SR4M4040 40VDC 2-1415054-1 SR4M4048 48VDC 3-1415054-1 SR4M4060 60VDC 4-1415054-1 SR4M4085 85VDC 5-1415054-1 SR4M4110 110VDC 6-1415054-1 10-2012, Rev. 1012 www.te.com © 2012 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change. 3