MACOM 2-1415055-1

General Purpose Relays
Force Guided Relays
SCHRACK
Force Guided Relay SR4 D/M
n4
pole relay with force guided contacts according to EN 50205
design & space efficient
nCompact
Typical applications
Emergency shut-off, press control, machine control, elevator and escalator
control, safety relays
F0244-C
ZT
Approvals
Coil Data (continued)
Technical data of approved types on request
Coil versions, DC-coil
Coil
Rated
Operate
Release
Coil
Rated coil
codevoltagevoltagevoltage
resistancepower
VDCVDCVDC
Ω±10%
mW
0212116.0 2.1551800
0242418.0 2.4720800
036 36 27.0 3.61620800
040 40 30.0 4.02000800
048 48 36.0 4.82880800
060 60 45.0 6.04500800
085 85 63.8 8.59031800
110 110 83.0 11.015125800
VDE 40005334, UL E214025, TUV 968/EL 230, CQC 06017015578
Contact Data
Contact arrangement 3 form A + 1 form B contacts
3 NO + 1 NC
2 form A + 2 form B contacts
2 NO + 2 NC
Rated voltage
250VAC
Max. switching voltage
400VAC
Rated current
8A
Contact material
AgSnO2
Contact style single contact, force guided
type A according to EN 50205
Min. recommended contact load
5V/10mA
Initial contact resistance
≤100mΩ at 1A, 24VDC
≤20Ω at 10mA, 5VDC
Frequency of operation, with/without load
6/150min-1
Contact ratings, IEC60947-5-1,
on 1 form A (NO) contact
AC15-3A
DC13-3A
Mechanical endurance
10x106 operations
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Insulation Data
Coil data
Coil voltage range
5 to 110VDC
Coil versions, DC-coil
Coil
Rated
Operate
Release
Coil
Rated coil
codevoltagevoltagevoltage
resistancepower
VDCVDCVDC
Ω±10%
mW
0055 3.80.531806
0066 4.50.645800
009 9 6.8 0.9101802
01212 9.0 1.2180800
0151511.3 1.5281801
0181813.5 1.8405800
10-2012, Rev. 1012
www.te.com
© 2012 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Initial dielectric strength
between open contacts
1500Vrms
between contact and coil
4000Vrms
between adjacent contacts
2500Vrms
Clearance/creepage
between open contacts
microdisconnection
between contact and coil
≥10/10mm
between adjacent contacts
≥3/3.5mm
Insulation to EN 50178, type of insulation
between contact and coil
reinforced
between adjacent contacts
basic
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
1
General Purpose Relays
Force Guided Relays
SCHRACK
Force Guided Relay SR4 D/M (Continued)
Other Data
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
refer to the Product Compliance Support Center at
www.te.com/customersupport/rohssupportcenter
Ambient temperature
-25 to 70°C
Category of environmental Protection
IEC 61 810
RTIII
Weight30g
Resistance to soldering heat THT
IEC 60068-2-20
260°C/5s
Packaging/unit
tube/10 pcs.
For more detailed information see product specification 2158002
PCB layout / terminal assignment
Bottom view on solder pins
S0413-BC
2 form A + 2 form B, 2 NO + 2 NC contacts
S0413-BB
Dimensions
3 form A + 1 form B, 3 NO + 1 NC contacts
S0413-BA
S0412-BH
Product code structure
Typical product code SR4D 4 012
Type
SR4 Relay with force guided contacts SR4
Contact arrangement
D 2 form A + 2 form B contacts (2 NO + 2 NC)
M 3 form A + 1 form B contacts (3 NO + 1 NC)
Contact material
4 AgSnO2
Coil
Coil code: please refer to coil versions table (e.g. 012=12VDC)
Other types on request
2
10-2012, Rev. 1012
www.te.com
© 2012 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
General Purpose Relays
Force Guided Relays
SCHRACK
Force Guided Relay SR4 D/M (Continued)
Product code
Type
Contact arrangement Contact material
Coil
Part number
SR4D4005
4 pole
2 form A + 2 form B,
AgSnO2 5VDC7-1415054-1
SR4D4006
relay with
2 NO + 2 NC
6VDC
8-1415054-1
SR4D4009
force guided contacts
contacts
9VDC
9-1415054-1
SR4D4012
12VDC
1415055-1
SR4D4018
18VDC
1-1415055-1
SR4D4021
21VDC
2-1415055-1
SR4D4024
24VDC
3-1415055-1
SR4D4036
36VDC
4-1415055-1
SR4D4040
40VDC
5-1415055-1
SR4D4048
48VDC
6-1415055-1
SR4D4060
60VDC
7-1415055-1
SR4D4085
85VDC
8-1415055-1
SR4D4110
110VDC
9-1415055-1
SR4M4005
3 form A + 1 form B,
5VDC
5-1415053-1
SR4M4006
3 NO + 1 NC
6VDC
6-1415053-1
SR4M4009contacts9VDC
7-1415053-1
SR4M4012
12VDC
8-1415053-1
SR4M4018
18VDC
9-1415053-1
SR4M4021
21VDC
1415054-1
SR4M4024
24VDC
4-1415053-1
SR4M4036
36VDC
1-1415054-1
SR4M4040
40VDC
2-1415054-1
SR4M4048
48VDC
3-1415054-1
SR4M4060
60VDC
4-1415054-1
SR4M4085
85VDC
5-1415054-1
SR4M4110
110VDC
6-1415054-1
10-2012, Rev. 1012
www.te.com
© 2012 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
3