T1/E1/OC3 TELECOM CLOCK GENERATOR WITH DUAL REFERENCE INPUTS IDT82V3010 FEATURES • • • • • • • • • • • • • • Supports AT&T TR62411 • Supports ETSI ETS 300 011, TBR 4, TBR 12 and TBR 13 timing for E1 interface • Selectable reference inputs: 8 kHz, 1.544 MHz, 2.048 MHz or 19.44 MHz • Accepts two independent reference inputs which may have same or different nominal frequencies applied to them • Provides C1.5o, C3o, C2o, C4o, C6o, C8o, C16o, C19o and C32o output clock signals • Provides 7 types of 8 kHz framing pulses: F0o, F8o, F16o, F19o, F32o, RSP and TSP • Provides a C2/C1.5 output clock signal with the frequency controlled by the selected reference input Fref0 or Fref1 Phase slope of 5 ns per 125 µs Attenuates wander from 2.1 Hz Fast lock mode Provides Time Interval Error (TIE) correction MTIE of 1 µs JTAG boundary scan Holdover status indication Freerun status indication Normal status indication Lock status indication Input reference quality indication 3.3 V operation with 5 V tolerant I/O Package: 56-pin SSOP (Green option available) FUNCTIONAL BLOCK DIAGRAM TDO TDI OSCi RST VDDD VSS VDDD VSS VDDD VSS VDDA VSS VDDA VSS TCLR C2/C1.5 TCK TMS TRST Fref0 Fref1 JTAG C32o C19o C19POS C19NEG OSC Reference Input Switch Virtual Reference TIE Control Block C16o C8o C4o C2o IN_sel MON_out0 MON_out1 C3o C1.5o C6o DPLL FLOCK F0o F8o Reference Input Monitor 0 F16o F19o F32o RSP TSP Feedback Signal Reference Input Monitor 1 LOCK Invalid Input Signal Detection Frequency Select Circuit 0 F0_sel0 F0_sel1 Frequency Select Circuit 1 F1_sel0 F1_sel1 State Control Circuit TIE_en MODE_sel1 MODE_sel0 Normal Holdover Freerun IDT and IDT logo are trademarks of Integrated Device Technology, Inc. 1 2006 Integrated Device Technology, Inc. June 19, 2006 DSC-6777/2 IDT82V3010 T1/E1/OC3 Telecom Clock Generator with Dual Reference Inputs DESCRIPTION The IDT82V3010 is compliant with AT&T TR62411 and ETSI ETS 300 011. It meets the jitter/wander tolerance, jitter/wander transfer, intrinsic jitter/wander, frequency accuracy, capture range, phase change slope, holdover frequency accuracy and MTIE (Maximum Time Interval Error) requirements for these specifications. The IDT82V3010 can be used in synchronization and timing control for T1, E1 and OC3 systems, or used as ST-BUS clock and frame pulse source. It also can be used in access switch, access routers, ATM edge switches, wireless base station controllers, or IADs (Integrated Access Devices), PBXs, line cards and SONET/SDH equipments. The IDT82V3010 is a T1/E1/OC3 telecom clock generator with dual reference inputs. It contains a Digital Phase-Locked Loop (DPLL), which generates low jitter ST-BUS and 19.44 MHz clock and framing signals that are phase locked to an 8 kHz, 1.544 MHz, 2.048 MHz or 19.44 MHz input reference. The IDT82V3010 provides 9 types of clock signals (C1.5o, C3o, C6o, C2o, C4o, C8o, C16o, C19o, C32o) and 7 types of framing signals (F0o, F8o, F16o, F19o, F32o, RSP, TSP) for multitrunk T1/E1 and STS3/OC3 links. PIN CONFIGURATION MODE_sel0 MODE_sel1 1 56 TIE_en 2 55 IC2 TCLR RST Fref0 3 54 C2/C1.5 4 53 IC0 5 HOLDOVER Fref1 MON_out0 6 7 8 52 51 50 49 9 48 F19o VDDA 47 VSS IN_sel 10 11 VSS 12 46 45 NORMAL FLOCK VDDD 13 44 LOCK C6o 14 43 C19o C1.5o 15 42 C3o C2o VSS 16 41 TSP RSP 17 40 F32o 18 19 20 39 38 37 F16o VSS 21 22 36 35 F8o F1_sel0 23 34 F1_sel1 C16o 24 C32o VDDD 25 26 33 32 F0o TDI 31 TMS VSS 27 30 TRST TCK 28 29 TDO MON_out1 F0_sel0 F0_sel1 VDDD C4o C19POS C19NEG C8o IDT82V3010 FREERUN OSCi VDDA Figure - 1 IDT82V3010 SSOP56 Package Pin Assignment Description 2 June 19, 2006 IDT82V3010 T1/E1/OC3 Telecom Clock Generator with Dual Reference Inputs TABLE OF CONTENTS 1 Pin Description...................................................................................................................................................................................................7 2 Functional Description ......................................................................................................................................................................................9 2.1 State Control Circuit ..................................................................................................................................................................................9 2.1.1 Normal Mode..............................................................................................................................................................................10 2.1.2 Fast Lock Mode..........................................................................................................................................................................10 2.1.3 Holdover Mode ...........................................................................................................................................................................10 2.1.4 Freerun Mode.............................................................................................................................................................................10 2.2 Frequency Select Circuit .........................................................................................................................................................................10 2.3 Reference Input Switch ...........................................................................................................................................................................10 2.4 Reference Input Monitor ..........................................................................................................................................................................11 2.5 Invalid Input Signal Detection ..................................................................................................................................................................11 2.6 TIE Control Block.....................................................................................................................................................................................11 2.7 DPLL Block..............................................................................................................................................................................................12 2.7.1 Phase Detector (PHD)................................................................................................................................................................12 2.7.2 Limiter.........................................................................................................................................................................................12 2.7.3 Loop Filter ..................................................................................................................................................................................13 2.7.4 Fraction Block.............................................................................................................................................................................13 2.7.5 Digital Control Oscillator (DCO)..................................................................................................................................................13 2.7.6 Lock Indicator .............................................................................................................................................................................13 2.7.7 Output Interface..........................................................................................................................................................................13 2.8 OSC.........................................................................................................................................................................................................14 2.8.1 Clock Oscillator ..........................................................................................................................................................................14 2.9 JTAG .......................................................................................................................................................................................................14 2.10 Reset, Lock and TIE Application .............................................................................................................................................................14 2.11 Power Supply Filtering Techniques .........................................................................................................................................................15 3 Measures of Performance ...............................................................................................................................................................................16 3.1 Intrinsic Jitter ...........................................................................................................................................................................................16 3.2 Jitter Tolerance........................................................................................................................................................................................16 3.3 Jitter Transfer ..........................................................................................................................................................................................16 3.4 Frequency Accuracy................................................................................................................................................................................16 3.5 Holdover Accuracy ..................................................................................................................................................................................16 3.6 Capture Range ........................................................................................................................................................................................16 3.7 Lock Range .............................................................................................................................................................................................16 3.8 Phase Slope ............................................................................................................................................................................................16 3.9 Time Interval Error (TIE)..........................................................................................................................................................................16 3.10 Maximum Time Interval Error (MTIE) ......................................................................................................................................................16 3.11 Phase Continuity .....................................................................................................................................................................................16 3.12 Phase Lock Time.....................................................................................................................................................................................17 4 Absolute Maximum Ratings ............................................................................................................................................................................18 5 Recommended DC Operating Conditions .....................................................................................................................................................18 6 DC Electrical Characteristics ..........................................................................................................................................................................18 6.1 Single End Input/Output Port...................................................................................................................................................................18 6.2 Differential Output Port (LVDS) ...............................................................................................................................................................19 7 AC Electrical Characteristics ..........................................................................................................................................................................20 7.1 Performance ............................................................................................................................................................................................20 7.2 Intrinsic Jitter Unfiltered ...........................................................................................................................................................................20 7.3 C1.5o (1.544 MHz) Intrinsic Jitter Filtered ...............................................................................................................................................21 7.4 C2o (2.048 MHz) Intrinsic Jitter Filtered ..................................................................................................................................................21 7.5 C19o (19.44 MHz) Intrinsic Jitter Filtered ................................................................................................................................................21 7.6 8 kHz Input to 8 kHz Output Jitter Transfer .............................................................................................................................................21 7.7 1.544 MHz Input to 1.544 MHz Output Jitter Transfer.............................................................................................................................22 7.8 2.048 MHz Input to 2.048 MHz Output Jitter Transfer.............................................................................................................................22 Table Of Contents 3 June 19, 2006 IDT82V3010 7.9 7.10 7.11 7.12 7.13 T1/E1/OC3 Telecom Clock Generator with Dual Reference Inputs 19.44 MHz Input to 19.44 MHz Output Jitter Transfer.............................................................................................................................22 8 kHz Input Jitter Tolerance.....................................................................................................................................................................23 1.544 MHz Input Jitter Tolerance ............................................................................................................................................................23 2.048 MHz Input Jitter Tolerance ............................................................................................................................................................23 19.44 MHz Input Jitter Tolerance ............................................................................................................................................................24 8 Timing Characteristics ....................................................................................................................................................................................26 8.1 Timing Parameter Measurement Voltage Levels ....................................................................................................................................26 8.2 Input/Output Timing .................................................................................................................................................................................26 9 Ordering Information .......................................................................................................................................................................................31 Table Of Contents 4 June 19, 2006 IDT82V3010 T1/E1/OC3 Telecom Clock Generator with Dual Reference Inputs LIST OF FIGURES Figure - 1 Figure - 2 Figure - 3 Figure - 4 Figure - 5 Figure - 6 Figure - 7 Figure - 8 Figure - 9 Figure - 10 Figure - 11 Figure - 12 Figure - 13 Figure - 14 Figure - 15 IDT82V3010 SSOP56 Package Pin Assignment ................................................................................................................................ 2 State Control Circuit ............................................................................................................................................................................ 9 State Control Diagram......................................................................................................................................................................... 9 TIE Control Block Diagram................................................................................................................................................................ 11 Reference Switch with TIE Control Block Enabled............................................................................................................................ 12 Reference Switch with TIE Control Block Disabled........................................................................................................................... 12 DPLL Block Diagram ......................................................................................................................................................................... 13 Clock Oscillator Circuit ...................................................................................................................................................................... 14 Power-Up Reset Circuit..................................................................................................................................................................... 14 IDT82V3010 Power Decoupling Scheme.......................................................................................................................................... 15 Timing Parameter Measurement Voltage Levels .............................................................................................................................. 26 Input to Output Timing (Normal Mode).............................................................................................................................................. 28 Output Timing 1................................................................................................................................................................................. 29 Output Timing 2................................................................................................................................................................................. 30 Input Control Setup and Hold Timing ................................................................................................................................................ 30 List of Figures 5 June 19, 2006 IDT82V3010 T1/E1/OC3 Telecom Clock Generator with Dual Reference Inputs LIST OF TABLES Table - 1 Table - 2 Table - 3 Table - 4 Table - 5 List of Tables Operating Modes Selection ..................................................................................................................................................................9 Fref0 Frequency Selection .................................................................................................................................................................10 Fref1 Frequency Selection .................................................................................................................................................................10 Input Reference Selection ..................................................................................................................................................................11 C2/C1.5 Output Frequency Control....................................................................................................................................................14 6 June 19, 2006 IDT82V3010 1 T1/E1/OC3 Telecom Clock Generator with Dual Reference Inputs PIN DESCRIPTION Name Type Pin Number VSS Power 12, 18, 27 38, 47 VDDD Power 13, 19, 26 VDDA Power 37, 48 OSCi (CMOS) I 50 Fref0 Fref1 I 5 6 IN_sel I 11 F0_sel0 F0_sel1 I 9 10 F1_sel0 F1_sel1 I 35 34 MODE_sel0 MODE_sel1 I 1 2 RST I 4 TCLR I 3 TIE_en I 56 FLOCK I 45 LOCK (CMOS) O 44 HOLDOVER (CMOS) O 52 NORMAL (CMOS) O 46 FREERUN (CMOS) O 51 MON_out0 O 7 MON_out1 O 8 C19POS C19NEG (LVDS) O 21 22 Pin Description Description Ground. 0 V. All VSS pins should be connected to the ground. 3.3 V Digital Power Supply. Refer to “2.11 Power Supply Filtering Techniques”. 3.3 V Analog Power Supply. Refer to “2.11 Power Supply Filtering Techniques”. Oscillator Master Clock Input. This pin is connected to a clock source. Reference Input 0 and Reference Input 1. These are two input reference sources (falling edge of 8 kHz, 1.544 MHz and 2.048 MHz or rising edge of 19.44 MHz) used for synchronization. The IN_sel pin determines which one of the two reference inputs to be used. See Table - 4 for details. The frequency of the reference inputs can be 8 kHz, 1.544 MHz, 2.048 MHz or 19.44 MHz. These two pins are internally pulled up to VDDD. Input Reference Selection. A logic low at this pin selects Reference Input 0 (Fref0) and a logic high at this pin selects Reference Input 1 (Fref1). The logic level on this input is gated in by the rising edges of F8o. This Pin is internally pulled down to VSS. Frequency Selection Inputs for Fref0. These two inputs select one of the four possible frequencies (8 kHz, 1.544 MHz, 2.048 MHz or 19.44 MHz) for the Reference Input 0 (Fref0). See Table - 2 for details. Frequency Selection Inputs for Fref1. These two inputs select one of the four possible frequencies (8 kHz, 1.544 MHz, 2.048 MHz or 19.44 MHz) for the Reference Input 1 (Fref1). These two pins are internally pulled down to Vss. See Table - 3 for details. Mode Selection Inputs. These two inputs determine the operating mode of the IDT82V3010 (Normal, Holdover or Freerun). See Table - 1 for details. The logic levels on these two pins are gated in by the rising edges of F8o. These two pins are internally pulled down to VSS. Reset Input. Pulling this pin to logic low for at least 300 ns will reset the IDT82V3010. While the RST pin is low, all framing and clock outputs are at logic high. To ensure proper operation, the device must be reset after it is powered up. TIE Control Block Reset. Pulling this pin to logic low for at least 300 ns will reset the TIE (Maximum Time Interval Error) control block and result in a realignment of the output phase with the input phase. This pin is internally pulled up to VDDD. TIE Control Block Enable. A logic high at this pin enables the TIE control block while a logic low disables it. The logic level on this input is gated in by the rising edges of F8o. This pin is internally pulled down to Vss. Fast Lock Mode Enable. When this pin is set to logic high, the DPLL will quickly lock to the input reference within 500 ms. Lock Indicator. This output pin will go high when the DPLL is frequency locked to the input reference. Holdover Indicator. This output pin will go high whenever the DPLL enters Holdover mode. Normal Indicator. This output pin will go high whenever the DPLL enters Normal mode. Freerun Indicator. This output pin will go high whenever the DPLL enters Freerun mode. Frequency Out-of-range Indicator for Fref0. A logic high at this pin indicates that Fref0 is off the nominal frequency by more than ±12 ppm. Frequency Out-of-range Indicator for Fref1. A logic high at this pin indicates that Fref1 is off the nominal frequency by more than ±12 ppm. 19.44 MHz Clock Output (LVDS Level). This pair of outputs is used for OC3/STS3 applications. 7 June 19, 2006 IDT82V3010 T1/E1/OC3 Telecom Clock Generator with Dual Reference Inputs Name Type Pin Number C19o (CMOS) O 43 C32o (CMOS) O 25 C16o (CMOS) O 24 C8o (CMOS) O 23 C4o (CMOS) O 20 C2o (CMOS) O 17 C3o (CMOS) O 16 C1.5o (CMOS) O 15 C6o (CMOS) O 14 C2/C1.5 (CMOS) O 54 F19o (CMOS) O 49 F32o (CMOS) O 40 F16o (CMOS) O 39 F8o (CMOS) O 36 F0o (CMOS) O 33 RSP (CMOS) O 41 TSP (CMOS) O 42 TDO (CMOS) O 29 TDI I 32 TRST I 30 TCK I 28 TMS I 31 IC0, IC2 - 53, 55 Pin Description Description 19.44 MHz Clock Output (CMOS Level). This output is used for OC3/STS3 applications. 32.768 MHz Clock Output. This output is a 32.768 MHz clock used for ST-BUS operation. 16.384 MHz Clock Output. This output is a 16.384 MHz clock used for ST-BUS operation. 8.192 MHz Clock Output. This output is an 8.192 MHz clock used for ST-BUS operation. 4.096 MHz Clock Output. This output is a 4.096 MHz clock used for ST-BUS operation. 2.048 MHz Clock Output. This output is a 2.048 MHz clock used for ST-BUS operation. 3.088 MHz Clock Output. This output is used for T1 applications. 1.544 MHz Clock Output. This output is used for T1 applications. 6.312 MHz Clock Output. This output is used for DS2 applications. 2.048 MHz or 1.544 MHz Clock Output. This output is a 2.048 MHz or 1.544 MHz clock signal. If the selected reference input (Fref0 or Fref1) is 8 kHz, 2.048 MHz, or 19.44 MHz, the C2/C1.5 pin will output a 2.048 MHz clock signal. If the frequency of the selected reference input (Fref0 or Fref1) is 1.544 MHz, the C2/C1.5 pin will output a 1.544 MHz clock signal. Refer to Table - 5 for details. 8 kHz Frame Signal with 19.44 MHz Pulse Width. This output is used for OC3/STS3 applications. Frame Pulse ST-BUS 8.192 Mb/s. This is an 8 kHz 30 ns active low framing pulse, which marks the beginning of an ST-BUS frame. This framing signal is typically used for ST-BUS operation at 8.192 Mb/s. Frame Pulse ST-BUS 8.192 Mb/s. This is an 8 kHz 61 ns active low framing pulse, which marks the beginning of an ST-BUS frame. This framing signal is typically used for ST-BUS operation at 8.192 Mb/s. Frame Pulse. This is an 8 kHz 122 ns active high framing pulse, which marks the beginning of a frame. Frame Pulse ST-BUS 2.048 Mb/s. This is an 8 kHz 244 ns active low framing pulse, which marks the beginning of an ST-BUS frame. This framing signal is typically used for ST-BUS operation at 2.048 Mb/s and 4.096 Mb/s. Receive Sync Pulse. This is an 8 kHz 488 ns active high framing pulse, which marks the beginning of a ST-BUS frame. This framing signal is typically used to connect to the Siemens MUNICH-32 device. Transmit Sync Pulse. This is an 8 kHz 488 ns active high framing pulse, which marks the beginning of an ST-BUS frame. This framing is typically used to connect to the Siemens MUNICH-32 device. Test Serial Data Out. JTAG serial data is output on this pin on the falling edge of TCK. This pin is held in high impedance state when JTAG scan is not enabled. Test Serial Data In. JTAG serial test instructions and data are shifted in on this pin. This pin is internally pulled up to VDDD. Test Reset. Asynchronously initializes the JTAG TAP controller by putting it in the Test-Logic-Reset state. This pin is internally pulled up to VDDD. It is connected to the ground for normal applications. Test Clock. Provides the clock for the JTAG test logic. Test Mode Select. JTAG signal that controls the state transitions of the TAP controller. This pin is internally pulled up to VDDD. These pins should be connected to VSS. 8 June 19, 2006 IDT82V3010 2 T1/E1/OC3 Telecom Clock Generator with Dual Reference Inputs FUNCTIONAL DESCRIPTION TIE Block Enable/Disable The IDT82V3010 is a T1/E1/OC3 telecom clock generator with dual reference inputs, providing timing (clock) and synchronization (framing) signals to interface circuits for multitrunk T1/E1 and STS3/OC3 links. The details are described in the following sections. 2.1 Output of the Invalid Input Signal Detection State Control Circuit STATE CONTROL CIRCUIT IN_sel The State Control Circuit is an important part in the IDT82V3010. It is used to control the TIE block and the DPLL block as shown in Figure - 2. The control is based on the result of Invalid Input Signal Detection and the logic levels on the MODE_sel0, MODE_sel1, IN_sel and TIE_en pins. The IDT82V3010 can be operated in three different modes: Normal, Holdover and Freerun. The operating mode is selected by the MODE_sel1 and MODE_sel0 pins, as shown in Table - 1. Figure - 3 shows the state control diagram. All state changes occur synchronously on the rising edge of F8o. Three operating modes, Normal (S1), Holdover (S3) and Freerun (S0) can be switched from one to another by changing the logic levels on the MODE_sel0 and MODE_sel1 pins. DPLL Block Mode Control TIE_en MODE_sel1 F8o MODE_sel0 Figure - 2 State Control Circuit Table - 1 Operating Modes Selection Mode Selection Pins Operating Mode MODE_sel1 MODE_sel0 0 0 Normal 0 1 Holdover 1 0 Freerun 1 1 Reserved Reset * oT Aut S0 Freerun Mode_sel1 = 1 Mode_sel0 = 0 ble i sa IE D oT Aut ble i sa IE D Auto Aut oTI E TIE Disa ble Dis abl e (Valid Input Reference Signal) TIE Enable (TIE_en = H) (Valid Input Reference Signal) TIE Disable (TIE_en = L) S1 Normal Mode_sel1 = 0 Mode_sel0 = 0 S2 Auto - Holdover Mode_sel1 = 0 Mode_sel0 = 0 (Invalid Input Reference Signal) Auto TIE Disable TI E TIE E Dis ab le (TI E Aut oTI E nab le ( _e n= nt s ie an Tr le el ab _s IN Dis TIE to Au t sien Tran _sel ) n=L IE_e le (T isab No IN D TIE No IN_ sel TIE Tra En nsi abl ent e (T IE_ en =H ) L) Dis abl e TIE _en = H) t Au IE oT a Dis ble S3 Holdover Mode_sel1 = 0 Mode_sel0 = 1 S4 Short Time Holdover Mode_sel1 = 0 Mode_sel0 = 0 el IN_s t sien Tran Auto ble Disa TIE * Note: After reset, the Mode_sel1 and Mode_sel0 should be initially set to '10' or '00'. Figure - 3 State Control Diagram Functional Description 9 June 19, 2006 IDT82V3010 T1/E1/OC3 Telecom Clock Generator with Dual Reference Inputs 2.1.4 The mode changes between Normal (S1) and Auto-Holdover (S2) are triggered by the Invalid Input Reference Detection Circuit and are irrelative to the logic levels on the MODE_sel0 and MODE_sel1 pins. At the stage of S1, if the input reference is invalid (out of the capture range), the operating mode will be changed to Auto-Holdover (S2) automatically. At the stage of S2, if no IN_sel transient occurs and the input reference becomes valid, the operating mode will be changed back to Normal (S1) automatically. If an IN_sel transient is detected at the stage of S2, the operating mode will be changed to Short Time Holdover (S4) with the TIE Control Block automatically disabled. Refer to “2.5 Invalid Input Signal Detection” for more information. The mode changes between Normal (S1) and Short Time Holdover (S4) are triggered by the IN_sel transient. At the stage of S1, if a voltage transient occurs on the IN_sel pin, the operating mode will be changed to Short Time Holdover (S4) automatically. At the stage of S4, if no voltage transient occurs on the IN_sel pin, the operating mode will be changed back to S1 automatically. See “2.3 Reference Input Switch” for details. When the operating mode is changed from one to another, the TIE control block is automatically disabled as shown in Figure - 3, except the changes from Short Time Holdover (S4), Holdover (S3) or AutoHoldover (S2) to Normal (S1). In the case of changing from S4, S3 or S2 to S1, the TIE control block is enabled or disabled by the TIE_en pin. 2.1.1 The Freerun mode is typically used when a master clock source is required, or used when a system is just powered up and the network synchronization has not been achieved. In this mode, the IDT82V3010 provides timing and synchronization signals which are based on the master clock frequency (OSCi) only, and are not synchronized to the input reference signal. The accuracy of the output clock is equal to the accuracy of the master clock (OSCi). So if a ±32 ppm output clock is required, the master clock must also be ±32 ppm. Refer to “2.8 OSC” for more information. Whenever the IDT82V3010 works in the Freerun mode, the FREERUN pin will be set to logic high. 2.2 NORMAL MODE Table - 2 Fref0 Frequency Selection Frequency Selection Pins F0_sel0 0 0 19.44 MHz 0 1 8 kHz 1 0 1.544 MHz 1 1 2.048 MHz Frequency Selection Pins FAST LOCK MODE HOLDOVER MODE The Holdover mode is typically used for short duration (e.g., 2 seconds) while network synchronization is temporarily disrupted. In the Holdover mode, the IDT82V3010 provides timing and synchronization signals that are not locked to an external reference signal, but are based on storage techniques. In the Normal mode, when the output frequency is locked to the input reference signal, a numerical value corresponding to the output frequency is stored alternately in two memory locations every 30 ms. When the device is changed to the Holdover mode, the stored value from between 30 ms and 60 ms is used to set the output frequency of the device. Whenever the IDT82V3010 works in the Holdover mode, the HOLDOVER pin will be set to logic high. Functional Description Fref0 Input Frequency F0_sel1 Table - 3 Fref1 Frequency Selection The Fast Lock mode is a submode of the Normal mode. It allows the DPLL to lock to a reference more quickly than the Normal mode allows. Typically, the locking time in the Fast Lock mode is less than 500 ms. When the FLOCK pin is set to high, the Fast Lock mode will be enabled. 2.1.3 FREQUENCY SELECT CIRCUIT The input reference can be 8 kHz, 1.544 MHz, 2.048 MHz or 19.44 MHz. The F0_sel1 and F0_sel0 pins select one of the four frequencies for the reference input 0 (Fref0). The F1_sel1 and F1_sel0 pins select one of the four frequencies for the reference input 1 (Fref1). See Table 2 and Table - 3 for details. The reference inputs Fref0 and Fref1 may have different frequencies applied to them. Every time the frequency is changed, the device must be reset to make the change effective. The Normal mode is typically used when a slave clock source synchronized to the network is required. In this mode, the IDT82V3010 provides timing (C1.5o, C3o, C2o, C4o, C8o, C16o, C19o, C32o) and synchronization (F0o, F8o, F16o, F19o, F32o, TSP, RSP) signals. All these signals are synchronous to one of the two input references. The nominal frequency of the input reference can be 8 kHz, 1.544 MHz, 2.048 MHz or 19.44 MHz. After reset, the IDT82V3010 will take 30 seconds at most to make the output signals synchronous (phase locked) to the input reference. Whenever the IDT82V3010 works in the Normal mode, the NORMAL pin will be set to logic high. 2.1.2 FREERUN MODE 2.3 Fref1 Input Frequency F1_sel1 F1_sel0 0 0 19.44 MHz 0 1 8 kHz 1 0 1.544 MHz 1 1 2.048 MHz REFERENCE INPUT SWITCH The IDT82V3010 accepts two simultaneous reference signals Fref0 and Fref1, and operates on the falling edge (8 kHZ, 1.544 MHz and 2.048 MHz) or rising edge (19.44 MHz). One of the two reference signals will be input to the device, as determined by the IN_sel pin. See Table - 4. The selected reference signal is sent to the TIE control block, 10 June 19, 2006 IDT82V3010 T1/E1/OC3 Telecom Clock Generator with Dual Reference Inputs 2.5 Reference Input Monitor and Invalid Input Signal Detection block for further processing. INVALID INPUT SIGNAL DETECTION When a transient voltage occurs on the IN_sel pin, the operating mode will be changed to Short Time Holdover (S4) with the TIE Control Block automatically disabled. At the stage of S4, if no IN_sel transient occurs, the reference signal will be switched from one to the other, and the operating mode will be changed back to Normal (S1) automatically. During the change from S4 to S1, the TIE Control Block can be enabled or disabled, depending on the logic level on the TIE_en pin. See Figure 3 for details. This circuit is used to detect if the selected input reference (Fref0 or Fref1) is out of the capture range. Refer to “3.6 Capture Range” for details. This includes a complete loss of the input reference and a large frequency shift in the input reference. If the input reference is invalid (out of the capture range), the IDT82V3010 will be automatically changed to the Holdover mode (AutoHoldover). When the input reference becomes valid, the device will be changed back to the Normal mode and the output signals will be locked to the input reference. In the Holdover mode, the output signals are based on the output reference signal 30 ms to 60 ms prior to entering the Holdover mode. The amount of phase drift while in holdover can be negligible because the Holdover mode is very accurate. Consequently, the phase delay between the input and output after switching back to the Normal mode is preserved. 2.4 2.6 Table - 4 Input Reference Selection IN_sel Input Reference 0 Fref0 1 Fref1 REFERENCE INPUT MONITOR TIE CONTROL BLOCK If the current reference is badly damaged or lost, it is necessary to use the other reference or the one generated by storage techniques instead. But when switching the reference, a step change in phase on the input reference will occur. A step change in phase in the input to DPLL may lead to an unacceptable phase change on the output signals. The TIE control block, when enabled, prevents a step change in phase on the input reference signals from causing a step change in phase on the output of the DPLL block. Figure - 4 shows the TIE Control Block diagram. The IDT82V3010 monitors the Fref0 and Fref1 frequencies and outputs two signals at MON_out0 pin and MON_out1 pin to indicate the monitoring results respectively. Whenever the Fref0 frequency is off the nominal frequency by more than ±12 ppm, the MON_out0 pin will go high. The MON_out1 pin indicates the monitoring result of Fref1 in the same way. The MON_out0 and MON_out1 signals are updated every 2 seconds. Step Generation TIE_en IN_sel Fref0 Fref1 Reference Select Circuit Fref Storage Circuit Measure Circuit Feedback Signal Trigger Circuit Virtual Reference Signal TCLR Figure - 4 TIE Control Block Diagram When the IDT82V3010 primarily enters the Holdover mode for a short time period and then returns back to the Normal mode, the TIE Control Circuit should not be enabled. This will prevent undesired accumulated phase change between the input and output. If the TIE Control Block is disabled manually or automatically, a reference switch will result in a phase alignment between the input signal and the output signal as shown in Figure - 6. The slope of the phase adjustment is limited to 5 ns per 125 µs. When the TIE Control Block is enabled manually or automatically (by the TIE_en pin or TIE auto-enable logic generated by the State Control Circuit), it works under the control of the Step Generation circuit. At the Measure Circuit stage, the selected reference signal (Fref0 or Fref1) is compared with the feedback signal (current output feed back from the Frequency Select Circuit). The phase difference between the input reference and the feedback signal is stored in the Storage Circuit for TIE correction. According to the value stored in the storage circuit, the Trigger Circuit generates a virtual reference with the same phase as the previous reference. In this way, the reference can be switched without generating a step change in phase. Figure - 5 shows the phase transient that will result if a reference switch is performed with the TIE Control Block enabled. The value of the phase difference in the Storage Circuit can be cleared by applying a logic low reset signal to the TCLR pin. The minimum width of the reset pulse should be 300 ns. Functional Description 11 June 19, 2006 IDT82V3010 T1/E1/OC3 Telecom Clock Generator with Dual Reference Inputs Input Clock Ref1 Ref2 Output Clock Time = 0.00 s Time = 0.25 s Time = 0.50 s Time = 0.75 s Time = 1.0 s Time = 1.25 s Time = 1.50 s Time = 1.75 s Figure - 5 Reference Switch with TIE Control Block Enabled Input Clock Ref1 Ref2 Output Clock Time = 0.00 s Time = 0.25 s Time = 0.50 s Time = 0.75 s Time = 1.0 s Time = 1.25 s Time = 1.50 s Time = 1.75 s Figure - 6 Reference Switch with TIE Control Block Disabled 2.7 DPLL BLOCK In the Freerun or Holdover mode, the Frequency Select Circuit, the Phase Detector and the Limiter are inactive, and the input reference signal is not used. As shown in Figure - 7, the DPLL Block consists of a Phase Detector, a Limiter, a Loop Filter, a Digital Control Oscillator and Divider. 2.7.1 2.7.2 PHASE DETECTOR (PHD) In the Normal mode, the Phase Detector compares the reference signal from the TIE Control Circuit with the feedback from the Frequency Select Circuit, and outputs an error corresponding to the phase difference. This error signal is sent Limiter circuit for phase slope control. Functional Description LIMITER The Limiter is used to limit the phase slope. It ensures that the maximum output phase slope is limited to 5 ns per 125 µs for all input transient conditions. This well meets the AT&T TR62411specification which specify the maximum phase slope of 7.6 ns per 125 µs. virtual signal signal to the 12 June 19, 2006 IDT82V3010 T1/E1/OC3 Telecom Clock Generator with Dual Reference Inputs Fx_sel1 Fx_sel0 (x = 0 or 1) Output Interface 19.44 MHz Fraction_C19 155.52 MHz APLL C2/C1.5 C19POS C19NEG C19o C19_Divider F19o 24.704 MHz Digital Control Oscillator Fraction_T1 C1.5o T1_Divider C3o C2o C4o C8o C16o C32o 32.768 MHz E1_Divider F0o F8o F16o F32o RSP TSP 25.248 MHz Fraction_C6 Loop Filter Limiter FLOCK Phase Detector C6_Divider Frequency Selection Circuit 1 Feedback Signal Virtual Reference IN_sel F1_sel1 F1_sel0 C6o Frequency Selection Circuit 0 F0_sel1 F0_sel0 Figure - 7 DPLL Block Diagram 2.7.5 In the Normal mode, the Limiter receives the error signal from the Phase Detector, limits the phase slope within 5 ns per 125 µs and sends the limited signal to the Loop Filter. In the Fast Lock mode, the Limiter is disabled, and the DPLL locks to the input reference within 500 ms, which is much shorter than that in the Normal mode. 2.7.3 LOOP FILTER The Loop Filter ensures that the jitter transfer meets the ETS 300 011 and AT&T TR62411 requirements. It works similarly to a first order low pass filter with 2.1 Hz cutoff frequency for the four valid input frequencies (8 kHz, 1.544 MHz, 2.048 MHz or 19.44 MHz). The output of the Loop Filter goes to the Digital Control Oscillator directly or through the Fraction blocks, in which E1, T1, C6 and C19 signals are generated. 2.7.4 2.7.6 LOCK INDICATOR If the output frequency of the DPLL is identical to the input frequency, and the input phase offset is small enough so that no slope limiting is exhibited, the LOCK pin will be set high. FRACTION BLOCK 2.7.7 By applying some algorithms to the incoming E1 signal, the Fraction_C19, Fraction_C6 and Fraction_T1 blocks generate C19, C6 and T1 signals respectively. Functional Description DIGITAL CONTROL OSCILLATOR (DCO) In the Normal mode, the DCO receives four limited and filtered signals from Loop Filter or Fraction blocks. Based on the values of the received signals, the DCO generates four digital outputs: 19.44 MHz, 25.248 MHz, 32.768 MHz and 24.704 MHz for C19, C6, E1 and T1 dividers respectively. In the Holdover mode, the DCO is running at the same frequency as that generated by storage techniques. In the Freerun mode, the DCO is running at the same frequency as that of the master clock. OUTPUT INTERFACE The Output Interface uses three output signals from the DCO to generate totally 9 types of clock signals and 7 types of framing signals All these output signals are synchronous to F8o. 13 June 19, 2006 IDT82V3010 T1/E1/OC3 Telecom Clock Generator with Dual Reference Inputs FOX F7C-2E3-20.0 MHz Frequency: 20.0 MHz Tolerance: 25 ppm 0°C to 70°C Rise & Fall Time:10 ns (0.33 V, 2.97 V, 15 pF) Duty Cycle: 40% to 60% The 32.768 MHz signal is used by the E1_divider to generate five types of clock signals (C2o, C4o, C8o, C16o and C32o) with nominal 50% duty cycle and six types of framing signals (F0o, F8o, F16o, F32o, RSP and TSP). The 24.704 MHz signal is used by the T1_divider to generate two types of T1 signals (C1.5o and C3o) with nominal 50% duty cycle. The 25.248 MHz signal is used by the C6_divider to generate a C6o signal with nominal 50% duty cycle. The 19.44 MHz signal is sent to an APLL, which outputs a 155.52 MHz signal. The 155.52 MHz signal is used by the C19_divider to generate 19.44 MHz clock signals (C19o, C19POS and C19NEG) with nominal 50% duty cycle and a framing signal F19o. Additionally, the IDT82V3010 provides an output clock (C2/C1.5) with the frequency controlled by the frequency selection pins Fx_sel0 and Fx_sel1 (see Table - 5 for details). If the selected reference input (Fref0 or Fref1) is 8 kHz, 2.048 MHz or 19.44 MHz, the C2/C1.5 pin will output a 2.048 MHz clock signal. If the selected reference input (Fref0 or Fref1) is 1.544 MHz, the C2/C1.5 pin will output a 1.544 MHz clock signal. The electrical and timing characteristics of this output (2.048 MHz or 1.544 MHz) is the same as that of C2o or C1.5o. The output clock should be connected directly (not AC coupled) to the OSCi input of the IDT82V3010, as shown in Figure - 8. IDT82V3010 2.9 JTAG Fx_sel1 Fx_sel0 Frefx Input Frequency C2/C1.5 Output Frequency 0 0 19.44 MHz 2.048 MHz 2.10 0 1 8 kHz 2.048 MHz 1 0 1.544 MHz 1.544 MHz 1 1 2.048 MHz 2.048 MHz A simple power-up reset circuit is shown as Figure - 9. The logic low reset pulse is about 50 µs. The resistor Rp is used for protection only and limits current into the RST pin during power down. The logic low reset pulse width is not critical but should be greater than 300 ns. When the DPLL operates in Normal mode after power-up or reset, the lock pin may indicate frequency lock before the output phase is synchronized with the input. The phase lock requires 30 seconds (at most) after frequency lock. If users want to switch the input reference, it is highly recommended to do the switch after phase lock, with TIE control block enabled. After TIE control block is cleared, the DPLL requires some time for the phase relationship to stabilize. In general, the phase lock requires 30 seconds (at most) after frequency lock. The IDT82V3010 supports IEEE 1149.1 JTAG Scan. OSC The IDT82V3010 can use a clock as the master timing source. In the Freerun mode, the frequency tolerance of the clock outputs is identical to that of the source at the OSCi pin. For applications not requiring an accurate Freerun mode, the tolerance of the master timing source may be ±100 ppm. For applications requiring an accurate Freerun mode, such as AT&T TR62411, the tolerance of the master timing source must be no greater than ±32 ppm. The desired capture range should be taken into consideration when determining the accuracy of the master timing source. The sum of the accuracy of the master timing source and the capture range of the IDT82V3010 will always equal 230 ppm. For example, if the master timing source is 100 ppm, the capture range will be 130 ppm. 2.8.1 0.1 µF Figure - 8 Clock Oscillator Circuit Note: ‘x’ can be 0 or 1, as selected by IN_sel pin. IN_sel = 0: x = 0, Fref0 is the selected reference input. The frequency of Fref0 is determined by F0_sel0 and F0_sel1 pins. IN_sel = 1: x = 1, Fref1 is the selected reference input. The frequency of Fref1 is determined by F1_sel0 and F1_sel1 pins. 2.8 +3.3 V 20 MHz OUT GND OSCi Table - 5 C2/C1.5 Output Frequency Control Frequency Selection Pins +3.3 V RESET, LOCK AND TIE APPLICATION IDT82V3010 3.3 V R 10 kΩ RST Rp 1 kΩ C 1 µF CLOCK OSCILLATOR When selecting a Clock Oscillator, numerous parameters must be considered. This includes absolute frequency, frequency change over temperature, output rise and fall times, output levels and duty cycle. For applications requiring ±32 ppm clock accuracy, the following clock oscillator module may be used. Functional Description Figure - 9 Power-Up Reset Circuit 14 June 19, 2006 IDT82V3010 2.11 T1/E1/OC3 Telecom Clock Generator with Dual Reference Inputs POWER SUPPLY FILTERING TECHNIQUES 3.3V internal PLL. VDDD and VDDA should be individually connected to the power supply plane through vias, and bypass capacitors should be used for each pin. To achieve optimum jitter performance, power supply isolation is required. Figure - 10 illustrated how bypass capacitor and ferrite bead should be connected to each power pin. For the 82V3010, the decoupling for VDDA and VDDD must all be handled individually. The switching power supply should be filtering with a large bulk capacitor of 47 uF (1210 case size, ceramic) and a 0.1 uF (0402 case size, ceramic). VDDA provides power to the analog circuits. The analog power supply VDDA should have low impedance. This can be achieved by using one 10 uF (1210 case size, ceramic) and at least two 0.1 uF (0402 case size, ceramic) capacitors in parallel. The 0.1 uF (0402 case size, ceramic) capacitors must be placed right next to the VDDA pins as close as possible. Note that the 10 uF capacitor must be of 1210 case size, and it must be ceramic for lowest ESR (Effective Series Resistance) possible. The 0.1 uF should be of case size 0402, this offers the lowest ESL (Effective Series Inductance) to achieve low impedance towards the high speed range. VDDD is the power rail for the core logic as well as I/O driver circuits. For the VDDD, at least three 0.1 uF (0402 case size, ceramic) and one 10 uF (1210 case size, ceramic) capacitors are recommended. The 0.1 uF capacitors should be placed as close to the VDDD pins as possible. Please refer to evaluation board schematic for details. IDT82V3010 SLF7028T-100M1R1 10 µF 37 VDDA VSS 0.1 µF VSS 48 VSS VDDA VSS VSS 0.1 µF 12 18 27 38 47 3.3V SLF7028T-100M1R1 10 µF 13 VDDD 0.1 µF 19 VDDD 0.1 µF 26 VDDD 0.1 µF Figure - 10 IDT82V3010 Power Decoupling Scheme As in any high speed analog circuitry, the power supply pins are vulnerable to random noise. The 82V3010 provides separate power supplies to isolate any high switching noise from the outputs to the Functional Description 15 June 19, 2006 IDT82V3010 3 MEASURES MANCE T1/E1/OC3 Telecom Clock Generator with Dual Reference Inputs OF PERFOR- large input jitter signals (e.g., 75% of the specified maximum jitter tolerance). 3.4 The following are some synchronizer performance indicators and their corresponding definitions. 3.1 Frequency accuracy is defined as the absolute tolerance of an output clock signal when it is not locked to an external reference, but is operating in a free running mode. For the IDT82V3010, the Freerun accuracy is equal to the Master Clock (OSCi) accuracy. INTRINSIC JITTER Intrinsic jitter is the jitter produced by the synchronizing circuit and is measured at its output. It is measured by applying a reference signal with no jitter to the input of the device, and measuring its output jitter. Intrinsic jitter may also be measured when the device is in a nonsynchronizing mode, such as free running or holdover, by measuring the output jitter of the device. Intrinsic jitter is usually measured with various band limiting filters depending on the applicable standards. For the IDT82V3010, the intrinsic Jitter is limited to less than 0.02 UI on the 2.048 MHz and 1.544 MHz clocks. 3.2 3.5 JITTER TOLERANCE 3.6 CAPTURE RANGE Also referred to as pull-in range. This is the input frequency range over which the synchronizer must be able to pull into synchronization. The IDT82V3010 capture range is equal to ±230 ppm minus the accuracy of the master clock (OSCi). For example, a 32 ppm master clock results in a capture range of 198 ppm. The IDT82V3010 provides two pins, MON_out0 and MON_out1, to respectively indicate whether the reference inputs Fref0 and Fref1 are within ±12 ppm of the nominal frequency. JITTER TRANSFER Jitter transfer or jitter attenuation refers to the magnitude of jitter at the output of a device for a given amount of jitter at the input of the device. Input jitter is applied at various amplitudes and frequencies, and output jitter is measured with various filters depending on the applicable standards. For the IDT82V3010, two internal elements determine the jitter attenuation. This includes the internal 2.1 Hz low pass loop filter and the phase slope limiter. The phase slope limiter limits the output phase slope to 5 ns per 125 µs. Therefore, if the input signal exceeds this rate, such as for very large amplitude, low frequency input jitter, the maximum output phase slope will be limited (i.e., attenuated) to 5 ns per 125 µs. The IDT82V3010 has 16 outputs with 4 possible input frequencies for a total of 64 possible jitter transfer functions. Since all outputs are derived from the same signal, the jitter transfer values for the four cases, 8 kHz to 8 kHz, 1.544 MHz to 1.544 MHz, 2.048 MHz to 2.048 MHz and 19.44 MHz to 19.44 MHz can be applied to all outputs. It should be noted that 1 UI at 1.544 MHz is 644 ns, which is not equal to 1 UI at 2.048 MHz, which is 488 ns. Consequently, a transfer value using different input and output frequencies must be calculated in common units (e.g., seconds). Using the above method, the jitter attenuation can be calculated for all combinations of inputs and outputs based on the four jitter transfer functions provided. Note that the resulting jitter transfer functions for all combinations of inputs (8 kHz, 1.544 MHz, 2.048 MHz, 19.44 MHz) and outputs (8 kHz, 1.544 MHz, 3.088 MHz, 6.312 MHz, 2.048 MHz, 4.096 MHz, 8.192 MHz, 16.384 MHz, 19.44 MHz, 32.768 MHz) for a given input signal (jitter frequency and jitter amplitude) are the same. Since intrinsic jitter is always present, jitter attenuation will appear to be lower for small input jitter signals than for large ones. Consequently, accurate jitter transfer function measurements are usually made with Measures of Performance HOLDOVER ACCURACY Holdover accuracy is defined as the absolute tolerance of an output clock signal, when it is not locked to an external reference signal, but is operating using storage techniques. For the IDT82V3010, the storage value is determined while the device is in Normal mode and locked to an external reference signal. The absolute Master Clock (OSCi) accuracy of the IDT82V3010 does not affect Holdover accuracy, but the change in OSCi accuracy while in Holdover mode does. Jitter tolerance is a measure of the ability of a DPLL to operate properly (i.e., remain in lock and or regain lock in the presence of large jitter magnitudes at various jitter frequencies) when jitter is applied to its reference. The applied jitter magnitude and jitter frequency depends on the applicable standards. 3.3 FREQUENCY ACCURACY 3.7 LOCK RANGE This is the input frequency range over which the synchronizer must be able to maintain synchronization. The lock range is equal to the capture range for the IDT82V3010. 3.8 PHASE SLOPE Phase slope is measured in seconds per second and is the rate at which a given signal changes phase with respect to an ideal signal. The given signal is typically the output signal. The ideal signal is of constant frequency and is nominally equal to the value of the final output signal or final input signal. 3.9 TIME INTERVAL ERROR (TIE) TIE is the time delay between a given timing signal and an ideal timing signal. 3.10 MAXIMUM TIME INTERVAL ERROR (MTIE) MTIE is the maximum peak to peak delay between a given timing signal and an ideal timing signal within a particular observation period. 3.11 PHASE CONTINUITY Phase continuity is the phase difference between a given timing signal and an ideal timing signal at the end of a particular observation 16 June 19, 2006 IDT82V3010 T1/E1/OC3 Telecom Clock Generator with Dual Reference Inputs Lock time is very difficult to determine because it is affected by many factors including: 1. Initial input to output phase difference 2. Initial input to output frequency difference 3. Synchronizer loop filter 4. Synchronizer limiter Although a short lock time is desirable, it is not always possible to achieve due to other synchronizer requirements. For instance, better jitter transfer performance is achieved with a lower frequency loop filter which increases lock time. And better (smaller) phase slope performance (limiter) results in longer lock times. The IDT82V3010 loop filter and limiter are optimized to meet the AT&T TR62411 jitter transfer and phase slope requirements. Consequently, phase lock time, which is not a standard requirement, may be longer than in other applications. See “7.1 Performance”for details. The IDT82V3010 provides a FLOCK pin to enable the Fast Lock mode. When this pin is set to high, the DPLL will lock to an input reference within approximately 500 ms. period. Usually, the given timing signal and the ideal timing signal are of the same frequency. Phase continuity applies to the output of the synchronizer after a signal disturbance due to a mode change. The observation period is usually the time from the disturbance, to just after the synchronizer has settled to a steady state. In the case of the IDT82V3010, the output signal phase continuity is maintained to within ±5 ns at the instance (over one frame) of all mode changes. The total phase shift, depending on the type of mode change, may accumulate up to 200 ns over many frames. The rate of change of the 200 ns phase shift is limited to a maximum phase slope of approximately 5 ns per 125 µs. This meets the AT&T TR62411 maximum phase slope requirement of 7.6 ns per 125 µs. 3.12 PHASE LOCK TIME This is the time it takes the synchronizer to phase lock to the input signal. Phase lock occurs when the input signal and output signal are not changing in phase with respect to each other (not including jitter). Measures of Performance 17 June 19, 2006 IDT82V3010 4 T1/E1/OC3 Telecom Clock Generator with Dual Reference Inputs ABSOLUTE MAXIMUM RATINGS Ratings Min. Max. Unit Power supply voltage -0.5 5.0 V Voltage on any pin with respect to ground -0.5 5.5 V 200 mW 125 °C Package power dissipation Storage temperature -55 Note: Stresses greater than those listed under ABSOLUTE MAXIMUM RATINGS may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect reliability. 5 RECOMMENDED DC OPERATING CONDITIONS Parameter Min. Max. Unit Operating temperature -40 +85 °C Power supply voltage 3.0 3.6 V 6 DC ELECTRICAL CHARACTERISTICS 6.1 SINGLE END INPUT/OUTPUT PORT Parameter Description Min. Typ. Max. Units Test Conditions * IDDS Supply current with OSCi = 0 V 10 mA Outputs unloaded IDD Supply current with OSCi = Clock 60 mA Outputs unloaded VCIH CMOS high-level input voltage VCIL CMOS low-level input voltage VTIH TTL high-level input voltage VTIL TTL low-level input voltage IIL Input leakage current: Normal (low level) Normal (high level) Pull up (low level) Pull up (high level) Pull down (low level) Pull down (high level) -15 -15 -100 -15 -15 0 VOH High-level output voltage 2.4 VOL Low-level output voltage 0.7VDDD 0.3VDDD 2.0 0.8 15 15 0 15 15 100 0.4 V OSCi, Fref0 and Fref1 V OSCi, Fref0 and Fref1 V All input pins except for OSCi, Fref0 and Fref1 V All input pins except for OSCi, Fref0 and Fref1 µA VI = VDDD or 0 V V IOH = 8 mA V IOL = 8 mA * Note: 1. Voltages are with respect to ground (VSS) unless otherwise stated. 2. Supply voltage and operating temperature are as per Recommended Operating Conditions. Absolute Maximum Ratings 18 June 19, 2006 IDT82V3010 6.2 T1/E1/OC3 Telecom Clock Generator with Dual Reference Inputs DIFFERENTIAL OUTPUT PORT (LVDS) Parameter VOD ∆VOD VOS Description Differential Output Voltage Min. Typ. Max. Units Test Conditions 250 350 450 mV RL = 100 Ω 4 35 mV RL = 100 Ω 1.25 1.375 V RL = 100 Ω 5 25 mV RL = 100 Ω 1.38 1.6 V RL = 100 Ω V RL = 100 Ω Change in Magnitude of VOD for Complementary Output States Offset Voltage 1.125 ∆VOS Change in Magnitude of VOS for Complementary Output States VOH Output Voltage High VOL Output Voltage Low tTLH Output Rise time 0.38 1.5 ns RL = 100 Ω tTHL Output Fall time 0.40 1.5 ns RL = 100 Ω IOS Output Short Circuit Current 6.0 IOSD Differential Output Short Circuit Current 6.0 DC Electrical Characteristics 0.9 1.03 19 mA 10 mA June 19, 2006 IDT82V3010 T1/E1/OC3 Telecom Clock Generator with Dual Reference Inputs 7 AC ELECTRICAL CHARACTERISTICS 7.1 PERFORMANCE Description Min. Typ. Max. Units Test Conditions / Notes (see “Notes” on page 25) Freerun Mode accuracy with OSCi at: 0 ppm -0 +0 ppm 5-9 Freerun Mode accuracy with OSCi at: ±32 ppm -32 +32 ppm 5-9 Freerun Mode accuracy with OSCi at: ±100 ppm -100 +100 ppm 5-9 Capture range with OSCi at: 0 ppm -230 +230 ppm 1-3, 6-9 Capture range with OSCi at: ±32 ppm -198 +198 ppm 1-3, 6-9 Capture range with OSCi at: ±100 ppm -130 +130 ppm 1-3, 6-9 s 1-3, 6-15, 45 Phase lock time 50 Output phase continuity with reference switch 200 ns 1-3, 6-15 Output phase continuity with mode switch to Normal 200 ns 1-2, 4-15 Output phase continuity with mode switch to Freerun 200 ns 1-4, 6-15 Output phase continuity with mode switch to Holdover 50 ns 1-3, 6-15 Fref0 Frequency accuracy when MON_out0 is logic low -12 +12 ppm Fref1 Frequency accuracy when MON_out1 is logic low -12 +12 ppm MTIE (maximum time interval error) 1 µs 1-15, 28 Output phase slope 40 µs/s 1-15, 28 Reference input for Auto-Holdover with 8 kHz -18 k +18 k ppm 1-3, 6, 10-12 Reference input for Auto-Holdover with 1.544 MHz -36 k +36 k ppm 1-3, 7, 10-12 Reference input for Auto-Holdover with 2.048 MHz -36 k +36 k ppm 1-3, 8, 10-12 Reference input for Auto-Holdover with 19.44 MHz -36 k +36 k ppm 1-3, 9, 10-12 7.2 INTRINSIC JITTER UNFILTERED Max. Units Test Conditions / Notes (see “Notes” on page 25) Intrinsic jitter at F8o (8 kHz) 0.0001 UIpp 1-15, 22-25, 29 Intrinsic jitter at F0o (8 kHz) 0.0001 UIpp 1-15, 22-25, 29 Intrinsic jitter at F16o (8 kHz) 0.0001 UIpp 1-15, 22-25, 29 Intrinsic jitter at C1.5o (1.544 MHz) 0.015 UIpp 1-15, 22-25, 30 Intrinsic jitter at C3o (3.088 MHz) 0.03 UIpp 1-15, 22-25, 32 Intrinsic jitter at C2o (2.048 MHz) 0.01 UIpp 1-15, 22-25, 31 Intrinsic jitter at C6o (6.312 MHz) 0.06 UIpp 1-15, 22-25, 34 Intrinsic jitter at C4o (4.096 MHz) 0.02 UIpp 1-15, 22-25, 33 Intrinsic jitter at C8o (8.192 MHz) 0.04 UIpp 1-15, 22-25, 35 Intrinsic jitter at C16o (16.834 MHz) 0.04 UIpp 1-15, 22-25, 36 Intrinsic jitter at TSP (8 kHz) 0.0001 UIpp 1-15, 22-25, 29 Intrinsic jitter at RSP (8 kHz) 0.0001 UIpp 1-15, 22-25, 29 0.08 UIpp 1-15, 22-25, 38 Description Min. Typ. Intrinsic jitter at C32o (32.768 MHz) AC Electrical Characteristics 20 June 19, 2006 IDT82V3010 7.3 T1/E1/OC3 Telecom Clock Generator with Dual Reference Inputs C1.5o (1.544 MHZ) INTRINSIC JITTER FILTERED Max. Units Test Conditions / Notes (see “Notes” on page 25) Intrinsic jitter (4 Hz to 100 kHz filter) 0.008 UIpp 1-15, 22-25, 30 Intrinsic jitter (10 Hz to 40 kHz filter) 0.006 UIpp 1-15, 22-25, 30 Intrinsic jitter (8 kHz to 40 kHz filter) 0.006 UIpp 1-15, 22-25, 30 Intrinsic jitter (10 Hz to 8 kHz filter) 0.003 UIpp 1-15, 22-25, 30 Max. Units Test Conditions / Notes (see “Notes” on page 25) Intrinsic jitter (4 Hz to 100 kHz filter) 0.005 UIpp 1-15, 22-25, 31 Intrinsic jitter (10 Hz to 40 kHz filter) 0.004 UIpp 1-15, 22-25, 31 Intrinsic jitter (8 kHz to 40 kHz filter) 0.003 UIpp 1-15, 22-25, 31 Intrinsic jitter (10 Hz to 8 kHz filter) 0.002 UIpp 1-15, 22-25, 31 Typ. Max. Units Test Conditions / Notes (see “Notes” on page 25) Intrinsic jitter (500 Hz to 1.3 MHz filter) 0.4 0.5 nspp 1-15, 22-25, 37 Intrinsic jitter (65 kHz to 1.3 MHz filter) 0.2 0.3 nspp 1-15, 22-25, 37 Max. Units Test Conditions / Notes (see “Notes” on page 25) Description 7.4 Min. Typ. C19o (19.44 MHZ) INTRINSIC JITTER FILTERED Description 7.6 Typ. C2o (2.048 MHZ) INTRINSIC JITTER FILTERED Description 7.5 Min. Min. 8 KHZ INPUT TO 8 KHZ OUTPUT JITTER TRANSFER Description Min. Typ. Jitter attenuation for 1 [email protected] UIpp input 0 6 dB 1-3, 6, 10-15, 22-23, 25, 29, 39 Jitter attenuation for 1 [email protected] UIpp input 6 16 dB 1-3, 6, 10-15, 22-23, 25, 29, 39 Jitter attenuation for 10 [email protected] UIpp input 15 22 dB 1-3, 6, 10-15, 22-23, 25, 29, 39 Jitter attenuation for 60 [email protected] UIpp input 32 38 dB 1-3, 6, 10-15, 22-23, 25, 29, 39 Jitter attenuation for 300 [email protected] UIpp input 42 dB 1-3, 6, 10-15, 22-23, 25, 29, 39 Jitter attenuation for 3600 [email protected] UIpp input 50 dB 1-3, 6, 10-15, 22-23, 25, 29, 39 AC Electrical Characteristics 21 June 19, 2006 IDT82V3010 7.7 T1/E1/OC3 Telecom Clock Generator with Dual Reference Inputs 1.544 MHZ INPUT TO 1.544 MHZ OUTPUT JITTER TRANSFER Description Min. Typ. Max. Units Test Conditions / Notes (see “Notes” on page 25) Jitter attenuation for 1 Hz@20 UIpp input 0 6 dB 1-3, 7, 10-15, 22-23, 25, 30, 39 Jitter attenuation for 1 Hz@104 UIpp input 6 16 dB 1-3, 7, 10-15, 22-23, 25, 30, 39 Jitter attenuation for 10 Hz@20 UIpp input 17 22 dB 1-3, 7, 10-15, 22-23, 25, 30, 39 Jitter attenuation for 60 Hz@20 UIpp input 33 38 dB 1-3, 7, 10-15, 22-23, 25, 30, 39 Jitter attenuation for 300 Hz@20 UIpp input 45 dB 1-3, 7, 10-15, 22-23, 25, 30, 39 Jitter attenuation for 10 [email protected] UIpp input 48 dB 1-3, 7, 10-15, 22-23, 25, 30, 39 Jitter attenuation for 40 [email protected] UIpp input 50 dB 1-3, 7, 10-15, 22-23, 25, 30, 39 7.8 2.048 MHZ INPUT TO 2.048 MHZ OUTPUT JITTER TRANSFER Max. Units Test Conditions / Notes (see “Notes” on page 25) Jitter at output for 1 [email protected] UIpp input 2.5 UIpp 1-3, 8, 10-15, 22-23, 25, 31, 39 Jitter at output for 1 [email protected] UIpp input with 40 Hz to 100 kHz filter 0.07 UIpp 1-3, 8, 10-15, 22-23, 25, 31, 40 Jitter at output for 3 [email protected] UIpp input 1.4 UIpp 1-3, 8, 10-15, 22-23, 25, 31, 39 Jitter at output for 3 [email protected] UIpp input with 40 Hz to 100 kHz filter 0.10 UIpp 1-3, 8, 10-15, 22-23, 25, 31, 40 Jitter at output for 5 [email protected] UIpp input 0.90 UIpp 1-3, 8, 10-15, 22-23, 25, 31, 39 Jitter at output for 5 [email protected] UIpp input with 40 Hz to 100 kHz filter 0.10 UIpp 1-3, 8, 10-15, 22-23, 25, 31, 40 Jitter at output for 10 [email protected] UIpp input 0.40 UIpp 1-3, 8, 10-15, 22-23, 25, 31, 39 Jitter at output for 10 [email protected] UIpp input with 40 Hz to 100 kHz filter 0.10 UIpp 1-3, 8, 10-15, 22-23, 25, 31, 40 Jitter at output for 100 [email protected] UIpp input 0.06 UIpp 1-3, 8, 10-15, 22-23, 25, 31, 39 Jitter at output for 100 [email protected] UIpp input with 40 Hz to 100 kHz filter 0.05 UIpp 1-3, 8, 10-15, 22-23, 25, 31, 40 Jitter at output for 2400 [email protected] UIpp input 0.04 UIpp 1-3, 8, 10-15, 22-23, 25, 31, 39 Jitter at output for 2400 [email protected] UIpp input with 40 Hz to 100 kHz filter 0.03 UIpp 1-3, 8, 10-15, 22-23, 25, 31, 40 Jitter at output for 100 [email protected] UIpp input 0.04 UIpp 1-3, 8, 10-15, 22-23, 25, 31, 39 Jitter at output for 100 [email protected] UIpp input with 40 Hz to 100 kHz filter 0.02 UIpp 1-3, 8, 10-15, 22-23, 25, 31, 40 Description 7.9 Min. Typ. 19.44 MHZ INPUT TO 19.44 MHZ OUTPUT JITTER TRANSFER Description Min. Typ. Max. Units Test Conditions / Notes (see “Notes” on page 25) Jitter attenuation for 1 Hz@20 UIpp input 0 6 dB 1-3, 9-15, 22-23, 25, 37, 39 Jitter attenuation for 1 Hz@104 UIpp input 6 16 dB 1-3, 9-15, 22-23, 25, 37, 39 Jitter attenuation for 10 Hz@20 UIpp input 17 22 dB 1-3, 9-15, 22-23, 25, 37, 39 Jitter attenuation for 60 Hz@20 UIpp input 33 38 dB 1-3, 9-15, 22-23, 25, 37, 39 Jitter attenuation for 300 Hz@20 UIpp input 45 dB 1-3, 9-15, 22-23, 25, 37, 39 Jitter attenuation for 10 [email protected] UIpp input 48 dB 1-3, 9-15, 22-23, 25, 37, 39 Jitter attenuation for 40 [email protected] UIpp input 50 dB 1-3, 9-15, 22-23, 25, 37, 39 AC Electrical Characteristics 22 June 19, 2006 IDT82V3010 7.10 T1/E1/OC3 Telecom Clock Generator with Dual Reference Inputs 8 KHZ INPUT JITTER TOLERANCE Description Min. Typ. Max. Units Test Conditions / Notes (see “Notes” on page 25) Jitter tolerance for 1 Hz input 0.80 UIpp 1-3, 6, 10-15, 22-23, 25-27, 29 Jitter tolerance for 5 Hz input 0.70 UIpp 1-3, 6, 10-15, 22-23, 25-27, 29 Jitter tolerance for 20 Hz input 0.60 UIpp 1-3, 6, 10-15, 22-23, 25-27, 29 Jitter tolerance for 300 Hz input 0.16 UIpp 1-3, 6, 10-15, 22-23, 25-27, 29 Jitter tolerance for 400 Hz input 0.14 UIpp 1-3, 6, 10-15, 22-23, 25-27, 29 Jitter tolerance for 700 Hz input 0.07 UIpp 1-3, 6, 10-15, 22-23, 25-27, 29 Jitter tolerance for 2400 Hz input 0.02 UIpp 1-3, 6, 10-15, 22-23, 25-27, 29 Jitter tolerance for 3600 Hz input 0.01 UIpp 1-3, 6, 10-15, 22-23, 25-27, 29 Units Test Conditions / Notes (see “Notes” on page 25) 7.11 1.544 MHZ INPUT JITTER TOLERANCE Description Min. Typ. Max. Jitter tolerance for 1 Hz input 150 UIpp 1-3, 7, 10-15, 22-23, 25-27, 30 Jitter tolerance for 5 Hz input 140 UIpp 1-3, 7, 10-15, 22-23, 25-27, 30 Jitter tolerance for 20 Hz input 130 UIpp 1-3, 7, 10-15, 22-23, 25-27, 30 Jitter tolerance for 300 Hz input 38 UIpp 1-3, 7, 10-15, 22-23, 25-27, 30 Jitter tolerance for 400 Hz input 25 UIpp 1-3, 7, 10-15, 22-23, 25-27, 30 Jitter tolerance for 700 Hz input 15 UIpp 1-3, 7, 10-15, 22-23, 25-27, 30 Jitter tolerance for 2400 Hz input 5 UIpp 1-3, 7, 10-15, 22-23, 25-27, 30 Jitter tolerance for 10 kHz input 1.2 UIpp 1-3, 7, 10-15, 22-23, 25-27, 30 Jitter tolerance for 40 kHz input 0.5 UIpp 1-3, 7, 10-15, 22-23, 25-27, 30 Units Test Conditions / Notes (see “Notes” on page 25) 7.12 2.048 MHZ INPUT JITTER TOLERANCE Description Min. Typ. Max. Jitter tolerance for 1 Hz input 150 UIpp 1-3, 8, 10-15, 22-23, 25-27, 31 Jitter tolerance for 5 Hz input 140 UIpp 1-3, 8, 10-15, 22-23, 25-27, 31 Jitter tolerance for 20 Hz input 130 UIpp 1-3, 8, 10-15, 22-23, 25-27, 31 Jitter tolerance for 300 Hz input 40 UIpp 1-3, 8, 10-15, 22-23, 25-27, 31 Jitter tolerance for 400 Hz input 33 UIpp 1-3, 8, 10-15, 22-23, 25-27, 31 Jitter tolerance for 700 Hz input 18 UIpp 1-3, 8, 10-15, 22-23, 25-27, 31 Jitter tolerance for 2400 Hz input 5.5 UIpp 1-3, 8, 10-15, 22-23, 25-27, 31 Jitter tolerance for 10 kHz input 1.3 UIpp 1-3, 8, 10-15, 22-23, 25-27, 31 Jitter tolerance for 100 kHz input 0.4 UIpp 1-3, 8, 10-15, 22-23, 25-27, 31 AC Electrical Characteristics 23 June 19, 2006 IDT82V3010 7.13 T1/E1/OC3 Telecom Clock Generator with Dual Reference Inputs 19.44 MHZ INPUT JITTER TOLERANCE Units Test Conditions / Notes (see “Notes” on page 25) 2800 UIpp 1-3, 9-15, 22-23, 25-27, 37 Jitter tolerance for 178 µHz input 2800 UIpp 1-3, 9-15, 22-23, 25-27, 37 Jitter tolerance for 0.0016 Hz input 311 UIpp 1-3, 9-15, 22-23, 25-27, 37 Jitter tolerance for 0.0156 Hz input 311 UIpp 1-3, 9-15, 22-23, 25-27, 37 Jitter tolerance for 0.125 Hz input 39 UIpp 1-3, 9-15, 22-23, 25-27, 37 Jitter tolerance for 19.3 Hz input 39 UIpp 1-3, 9-15, 22-23, 25-27, 37 Jitter tolerance for 500 Hz input 1.5 UIpp 1-3, 9-15, 22-23, 25-27, 37 Jitter tolerance for 6.5 kHz input 1.5 UIpp 1-3, 9-15, 22-23, 25-27, 37 Jitter tolerance for 65 kHz input 0.15 UIpp 1-3, 9-15, 22-23, 25-27, 37 Jitter tolerance for 1.3 MHz input 0.15 UIpp 1-3, 9-15, 22-23, 25-27, 37 Description Min. Jitter tolerance for 12 µHz input AC Electrical Characteristics Typ. 24 Max. June 19, 2006 IDT82V3010 T1/E1/OC3 Telecom Clock Generator with Dual Reference Inputs Notes: Voltages are with respect to ground (VSS) unless otherwise stated. Supply voltage and operating temperature are as per Recommended Operating Conditions. Timing parameters are as per Timing Parameter Measurement Voltage Levels. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. 41. 42. 43. 44. 45. Fref0 reference input selected. Fref1 reference input selected. Normal mode selected. Holdover mode selected. Freerun mode selected. 8 kHz frequency mode selected. 1.544 MHz frequency mode selected. 2.048 MHz frequency mode selected. 19.44 MHz frequency mode selected. Master clock input OSCi at 20 MHz ±0 ppm. Master clock input OSCi at 20 MHz ±32 ppm. Master clock input OSCi at 20 MHz ±100 ppm. Selected reference input at ±0 ppm. Selected reference input at ±32 ppm. Selected reference input at ±100 ppm. For Freerun mode of ±0 ppm. For Freerun mode of ±32 ppm. For Freerun mode of ±100 ppm. For capture range of ±230 ppm. For capture range of ±198 ppm. For capture range of ±130 ppm. AC Electrical Characteristics 25 25 pF capacitive load. OSCi Master Clock jitter is less than 2 nspp, or 0.04 UIpp where 1 UIpp = 1/20 MHz. Jitter on reference input is less than 7 nspp. Applied jitter is sinusoidal. Minimum applied input jitter magnitude to regain synchronization. Loss of synchronization is obtained at slightly higher input jitter amplitudes. Within 10 ms of the state, reference or input change. 1 UIpp = 125 µs for 8 kHz signals. 1 UIpp = 648 ns for 1.544 MHz signals. 1 UIpp = 488 ns for 2.048 MHz signals. 1 UIpp = 323 ns for 3.088 MHz signals. 1 UIpp = 244 ns for 4.096 MHz signals. 1 UIpp = 158 ns for 6.312 MHz signals. 1 UIpp = 122 ns for 8.192 MHz signals. 1 UIpp = 61 ns for 16.484 MHz signals. 1 UIpp = 51 ns for 19.44 MHz signals. 1 UIpp = 30 ns for 32.968 MHz signals. No filter. 40 Hz to 100 kHz bandpass filter. With respect to reference input signal frequency. After a RST or TCLR. Master clock duty 40% to 60%. Prior to Holdover mode, device as in Normal mode and phase locked. With input frequency offset of 100 ppm. June 19, 2006 IDT82V3010 8 T1/E1/OC3 Telecom Clock Generator with Dual Reference Inputs TIMING CHARACTERISTICS 8.1 TIMING PARAMETER MEASUREMENT VOLTAGE LEVELS Parameter Description CMOS Units Threshold Voltage 0.5VDDD V VHM Rise and Fall Threshold Voltage High 0.7VDDD V VLM Rise and Fall Threshold Voltage Low 0.3VDDD V VT Timing Reference Points VHM All Siganls tIRF,tORF tIRF,tORF VT VLM Figure - 11 Timing Parameter Measurement Voltage Levels Notes: 1. Voltages are with respect to ground (VSS) unless otherwise stated. 2. Supply voltage and operating temperature are as per Recommended Operating Conditions. 3. Timing for input and output signals is based on the worst case result of the CMOS thresholds. 8.2 INPUT/OUTPUT TIMING Parameter tRW Description Reference input pulse width high or low tIRF Reference input rise or fall time tR8D 8 kHz reference input to F8o delay tR15D Min. Typ. Max. Units 51 ns 5 ns 10 ns 1.544 MHz reference input to F8o delay 332 ns tR2D 2.048 MHz reference input to F8o delay 253 ns tR19D 19.44 MHz reference input to F8o delay 8 ns tF0D F8o to F0o delay 118 tF16S F16o setup to C16o falling tF16H 124 ns 25 40 ns F16o hold to C16o falling 25 40 ns tF19S F19o setup to C19o falling 20 35 ns tF19H F19o hold to C19o falling 20 35 ns tC15D F8o to C1.5o delay -3 0 +3 ns tC3D F8o to C3o delay -3 1.6 +3 ns tC6D F8o to C6o delay -3 1.6 +3 ns tC2D F8o to C2o -2 0 +2 ns tC4D F8o to C4o -2 0 +2 ns tC8D F8o to C8o delay -2 0 +2 ns tC16D F8o to C16o delay -2 0 +2 ns Timing Characteristics 26 8 kHz, 1.544 MHz or 2.048 MHz reference input 19.44 MHz reference input ns 8 121 Test Conditions June 19, 2006 IDT82V3010 Parameter T1/E1/OC3 Telecom Clock Generator with Dual Reference Inputs Description Min. Typ. Max. Units tC19D F8o to C19o delay -8 0 +8 ns tC32D F8o to C32o delay -2 2 +2 ns tTSPD F8o to TSP delay -3 0 +3 ns tRSPD F8o to RSP delay -3 0 +3 ns tC15W C1.5o pulse width high or low 323 ns tC3W C3o pulse width high or low 161 ns tC6W C6o pulse width high or low 82 ns tC2W C2o pulse width high or low 244 ns tC4W C4o pulse width high or low 122 ns tC8W C8o pulse width high or low 61 ns tC16W C16o pulse width high or low 30.5 ns tC19W C19o pulse width high or low 25 ns tC32WH C32o pulse width high 14.4 ns tTSPW TSP pulse width high 486 ns tRSPW RSP pulse width high 490 ns tF0WL F0o pulse width low 243 ns tF8WH F8o pulse width high 123.6 ns tF16WL F16o pulse width low 60.9 ns tF19WH F19o pulse width high 25 ns Output clock and frame pulse rise or fall time 3 ns t0RF tS Input controls setup Time 100 ns tH Input controls hold Time 100 ns tF16D F8o to F16o delay 27.1 30.1 33.1 ns tF19D F8o to F19o delay 17 25 33 ns tF32D F8o to F32o delay 12 15.8 19 ns tF32S F32o setup to C32o falling 11 ns tF32H F32o hold to C32o falling 11 ns tF32WL F32o pulse width low Timing Characteristics 30.6 27 Test Conditions ns June 19, 2006 IDT82V3010 T1/E1/OC3 Telecom Clock Generator with Dual Reference Inputs tR8D Fref0/Fref1 8 kHz Fref0/Fref1 1.544 MHz Fref0/Fref1 2.048 MHz tRW tR15D tRW VT VT tR2D tRW VT tRW Fref0/Fref1 19.44 MHz tR19D VT VT F8o Figure - 12 Input to Output Timing (Normal Mode) Timing Characteristics 28 June 19, 2006 IDT82V3010 T1/E1/OC3 Telecom Clock Generator with Dual Reference Inputs tF8WH F8o tF0D tF0WL F0o F16o F32o VT tF16WL tF16D tF16S tF16H tF32WL tF32D tF32S tF32H tC32WH VT VT tC32D VT C32o tC16W tC16D VT C16o tC8W tC8W tC8D VT C8o tC4W tC4W tC4D C4o tC2W VT tC2D C2o (see Note 1) VT VT tC6W tC6W tC6D VT C6o tC3W tC3D C3o VT tC15D tC15W C1.5o (see Note 1) tF19WH tF19D VT F19o tF19S tC19W tF19H tC19D C19o tC19W VT VT tC19D VT C19POS tC19W C19NEG tC19D VT Figure - 13 Output Timing 1 Timing Characteristics 29 June 19, 2006 IDT82V3010 T1/E1/OC3 Telecom Clock Generator with Dual Reference Inputs F8o VT VT C2o tRSPD RSP tRSPW VT tTSPW TSP VT tTSPD Figure - 14 Output Timing 2 Note 1: The timing characteristic of C2/C1.5 (2.048 MHz or 1.544 MHz) is the same as that of C2o or C1.5o. VT F8o MODE_sel0 MODE_sel1 TIE_en IN_sel tS tH VT Figure - 15 Input Control Setup and Hold Timing Timing Characteristics 30 June 19, 2006 IDT82V3010 9 T1/E1/OC3 Telecom Clock Generator with Dual Reference Inputs ORDERING INFORMATION IDT XXXXXXX XX Device Type Package X Process/ Temperature Range Blank Industrial (-40 °C to +85 °C) PV Shrink Small Outline Package (SSOP, PV56) PVG Green - Shrink Small Outline Package (SSOP, PVG56) 82V3010 T1/E1/OC3 Telecom Clock Generator with Dual Reference Inputs DATASHEET DOCUMENT HISTORY 11/25/2004 pgs. 1, 10, 30 06/19/2006 pgs. 1, 2, 7, 15 CORPORATE HEADQUARTERS 6024 Silver Creek Valley Road San Jose, CA 95138 for SALES: 1-800-345-7015 or 408-284-8200 fax: 408-284-2775 www.idt.com The IDT logo is a registered trademark of Integrated Device Technology, Inc. 31 for Tech Support: 408-360-1552 email:[email protected]