Catalog: 1654001 Issue Date: 08.2010 Corcom Product Guide High Performance B Series RFI Line Filters SB Series UL Recognized CSA Certified VDE Approved 20VSB1 30ESB6 6VSB1 SB Series Specifications • Enhanced performance version of our popular B Series of RFI line filters • Small size with enhanced performance • 30A version half the size of other 30A filters • Low leakage version available that meets current requirements of VDE portable equipment and non-patient care medical equipment Ordering Information 20 E SB 6 Maximum leakage current each Line to Ground: @ 120 VAC 60 Hz: @250 VAC 50 Hz: VSB Models ESB Models .75 mA 1.25 mA .22 mA .36 mA Hipot rating (one minute): Line to Ground: Line to Line: Rated Voltage (max): 250 VAC 250 VDC Operating Frequency: 50/60 Hz Rated Current: Input / Output Style 1 – .250 [6.3] spade terminals 6 – Threaded bolt 2250 VDC 1450 VDC 6 to 30A Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculated as follows: Io = Ir √(85-Ta)/45 SB Series Leakage current designation E – Low leakage (<0.5 mA) V – Standard Current Rating 6, 10, 20 or 30A Available Part Numbers 6ESB1 10ESB1 10ESB6 20ESB1 20ESB6 30ESB6 6VSB1 10VSB1 10VSB6 20VSB1 20VSB6 30VSB6 Electrical Schematic LINE LOAD 70 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to tycoelectronics.com/help corcom.com Catalog: 1654001 Issue Date: 08.2010 Corcom Product Guide High Performance B Series RFI Line Filters (continued) SB Series Case Styles Case Dimensions Part No. 6ESB1 & 6VSB1 B Typical Dimensions: Line/Load Terminals (4): Ground Terminal (1): Mounting Holes (2): .250 [6.3] with .07 [1.8] Dia. hole .250 [6.3] with .07 x .16 [1.8 x 3.8] slot .188 [4.75] Dia. B C (max) (max) 3.36 85.34 3.36 85.34 3.47 88.14 3.85 97.79 4.00 101.60 4.92 124.97 1.82 46.23 1.82 46.23 1.82 46.23 2.07 52.58 2.07 52.58 2.07 52.58 0.91 23.11 1.28 32.51 1.53 38.86 1.31 33.27 1.53 38.86 1.53 38.86 D ± .015 ± .38 E (max) 1 2.375 2.78 60.325 70.61 2.375 2.78 60.325 70.61 2.375 2.78 60.325 70.61 2.938 3.35 74.625 85.09 2.938 3.35 74.625 85.09 3.947 4.33 100.254 109.98 RFI Power Line Filters D E A C 6ESB1, 6VSB1 10ESB1, 10VSB1 10ESB6, 10VSB6 20ESB1, 20VSB1 20ESB6, 20VSB6 30ESB6, 30VSB6 A (max) 10ESB1, 10VSB1, 20ESB1 & 20VSB1 B C Typical Dimensions: Line/Load Terminals (4): Ground Terminal (1): Mounting Holes (2): D E A .250 [6.3] with .07 [1.8] Dia. hole .250 [6.3] with .07 x .16 [1.8 x 3.8] slot .188 [4.75] Dia. ESB6 & VSB6 B C Typical Dimensions: Terminals (5): Mounting Holes (2): D E A 8-32, Torque 18 lbf-in. [2.03 N-m] max. ± 2 [.22] .188 [4.75] Dia. 71 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to tycoelectronics.com/help corcom.com Catalog: 1654001 Issue Date: 08.2010 Corcom Product Guide High Performance B Series RFI Line Filters (continued) SB Series Performance Data Typical Insertion Loss Measured in closed 50 Ohm system ESB Models 6ESB1 10ESB1 10ESB6 20ESB1 db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 70 70 70 70 60 60 60 60 80 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0 0.01 0.1 1 10 30 Frequency in MHz 0.01 0.1 20ESB6 30ESB6 db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 0 1 10 30 Frequency in MHz 1 10 30 Frequency in MHz 0 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 1 10 30 Frequency in MHz 1 10 30 Frequency in MHz 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 VSB Models 6VSB1 10VSB1 10VSB6 20VSB1 db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 20VSB6 30VSB6 db 100 db 100 90 90 80 10 30 Frequency in MHz 1 10 30 Frequency in MHz 0 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 80 70 70 60 60 50 50 40 40 30 30 20 20 10 0 1 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) 72 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to tycoelectronics.com/help corcom.com Catalog: 1654001 Issue Date: 08.2010 Corcom Product Guide High Performance B Series RFI Line Filters (continued) SB Series Performance Data (continued) 1 Minimum Insertion Loss Measured in closed 50 Ohm system Differential Mode / Symmetrical (Line to Line) Frequency – MHz Part No. .03 .05 .1 .15 .5 1 2 5 RFI Power Line Filters Common Mode / Asymmetrical (Line to Ground) Frequency – MHz 10 20 30 ESB Models Part No. .01 .03 .05 .1 .15 .5 1 2 5 10 20 30 ESB Models 6ESB1 3 8 13 17 31 37 40 47 50 58 62 6ESB1 5 14 20 25 29 41 49 47 50 60 74 72 10ESB1 3 9 15 19 31 39 41 44 47 54 51 10ESB1 5 15 20 26 29 41 47 50 54 64 74 74 10ESB6 3 9 14 18 31 39 41 44 47 54 54 10ESB6 5 14 20 25 29 41 47 48 50 60 62 64 15 21 26 29 41 45 48 54 63 70 66 20ESB1 3 7 13 15 30 35 37 39 40 46 40 20ESB1 5 20ESB6 3 7 13 16 30 35 39 40 44 58 46 20ESB6 5 15 21 26 29 41 44 48 54 63 70 66 30ESB6 3 7 13 17 30 34 37 40 42 49 58 30ESB6 5 14 20 25 29 40 46 50 50 58 70 70 6VSB1 3 8 14 19 37 47 51 58 66 59 49 6VSB1 5 14 20 25 29 40 41 57 66 78 56 62 VSB Models VSB Models 10VSB1 3 9 15 21 41 49 50 56 64 54 46 10VSB1 5 15 21 26 29 39 40 60 64 67 67 64 10VSB6 4 9 15 21 39 49 50 56 64 54 44 10VSB6 5 14 20 25 29 39 40 60 64 68 70 64 15 20 26 29 40 42 60 68 70 70 67 20VSB1 3 7 14 19 37 45 47 50 60 48 40 20VSB1 5 20VSB6 3 7 14 19 37 44 49 52 62 48 41 20VSB6 5 15 21 26 29 39 38 58 68 70 70 66 30VSB6 3 6 13 18 37 45 49 51 60 50 42 30VSB6 5 15 20 25 29 39 39 56 62 70 70 66 73 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to tycoelectronics.com/help corcom.com