FAIRCHILD KA79L24AZ

www.fairchildsemi.com
KA79LXXA
3-Terminal 0.1A Negative Voltage Regulator
Features
Description
•
•
•
•
•
•
These regulators employ internal current limiting and thermal shutdown, making them essentially indestructible.
Output current up to 100mA
No external components
Internal thermal over load protection
Internal short circuit current limiting
Output Voltage Offered in ± 5% Tolerance
Output Voltage of -5V, -8V, -12V, -15V, -18V
and -24V
TO-92
SOT-89
1
1
1.GND 2.Input 3.Output
8-SOP
1
1. Output 2.3.6.7. GND 4.5. NC 8. Input
Internal Block Diagram
Output
Input
Rev. 1.0.1
©2001 Fairchild Semiconductor Corporation
KA79LXXA
Absolute Maximum Ratings
Parameter
Symbol
Value
Unit
VI
-30
-35
-40
V
Operating Temperature Range
TOPR
0 ~ +125
°C
Storage Temperature Range
TSTG
-65 ~ +150
°C
Input Voltage (for Vo= -5V to -8V)
(for Vo= -12V to -18V)
(for Vo= -24V)
Electrical Characteristics(KA79L05A)
(VI = -10V, IO = 40mA, CI = 0.33µF, CO = 0.1µF, 0°C ≤TJ ≤ +125°C, unless otherwise specified)
Parameter
Symbol
Output Voltage
VO
Line Regulation (Note1)
Load Regulation (Note1)
Conditions
TJ = +25 °C
- 5.0
- 5.2
V
15
150
mV
-8V ≥ VI ≥-20V
-
-
100
mV
1.0mA ≤ IO ≤
100mA
-
20
60
mV
1.0mA ≤ IO ≤ 40mA
-
10
30
mV
-7.0V ≥ VI ≥ -20V, 1.0mA ≤ IO ≤ 40mA - 4.75
-
- 5.25
V
VI = -10V, 1.0mA≤ IO ≤70mA
- 4.75
-
- 5.25
V
TJ =+ 25 °C
-
2.0
5.5
TJ = +125 °C
-
-
6.0
TJ =+25 °C
IQ
Unit
-
∆VO
Quiescent Current
Max.
- 4.8
TJ =+25 °C
VO
Typ.
-7.0V ≥ VI ≥-20V
∆VO
Output Voltage
Min.
mA
with line
∆IQ
-8V≥ VI ≥-20V
-
-
1.5
mA
with load
∆IQ
1.0mA≤ IO ≤40mA
-
-
0.1
mA
Output Noise Voltage
VN
TA = +25°C,10Hz≤f≤100KHz
-
30
-
µV
Ripple Rejection
RR
f = 120Hz, -8V≥VI ≥-18V
TJ = +25°C
41
60
-
dB
Dropout Voltage
VD
TJ = +25°C
-
1.7
-
V
Quiescent Current
Change
Note
1. Load and line regulation are specified at constant junction temperature. Change in VO due to heating effects must be taken
into account separately. Pulse testing with low duty is used.
2
KA79LXXA
Electrical Characteristics (KA79L08A)
(VI = -14V, IO = 40mA, CI = 0.33µF, CO = 0.1µF, 0°C ≤TJ ≤ +125°C, unless otherwise specified)
Parameter
Symbol
Min.
Typ.
Max. Unit
- 7.7
- 8.0
- 8.3
V
-10.3V ≥ VI ≥ -23V
-
-
175
mV
-12V ≥ VI ≥ -23V
-
-
125
mV
1.0mA ≤ Io ≤ 100mA
-
-
80
mV
1.0mA ≤ Io ≤ 40mA
-
-
40
mV
-10.3V ≥ VI ≥ -23V, 1.0mA ≤ Io ≤ 40mA
- 7.6
-
- 8.4
VI = -14V, 1.0mA ≤ Io ≤ 70mA
- 7.6
-
- 8.4
Tj =+ 25 °C
-
-
6.0
Tj = +125 °C
-
-
5.5
-11.7V ≥ VI ≥ -23V
-
-
1.5
mA
1.0mA ≤ Io ≤ 40mA
-
-
0.1
mA
VN
Tj = +25°C,10Hz ≤ f ≤ 100KHz
-
50
-
µV
Ripple Rejection
RR
f = 120Hz, -11V ≥ VI ≥ -21V
Tj = +25°C
39
55
-
dB
Dropout Voltage
VD
Tj = +25°C
-
1.7
-
V
Output Voltage
Line Regulation (Note1)
Load Regulation (Note1)
VO
TJ = +25 °C
∆VO
TJ =+25 °C
∆VO
TJ =+25 °C
Output Voltage
VO
Quiescent Current
IQ
Quiescent Current
Change
with line
with load
Output Noise Voltage
Conditions
∆IQ
V
mA
Note
1. Load and line regulation are specified at constant junction temperature. Change in VO due to heating effects must be taken
into account separately. Pulse testing with low duty is used.
3
KA79LXXA
Electrical Characteristics(KA79L12A)
(VI = -19V, IO = 40mA, CI = 0.33µF, CO = 0.1µF, 0°C ≤TJ ≤ +125°C, unless otherwise specified)
Parameter
Symbol
Output Voltage
Line Regulation (Note1)
Load Regulation (Note1)
Output Voltage
VO
TJ = +25 °C
∆VO
TJ = +25 °C
∆VO
TJ = +25 °C
VO
Quiescent Current
Conditions
IQ
Min.
Typ.
Max.
-11.5 -12.0 -12.5
Unit
V
-14.5V ≥VI ≥-27V
-
-
250
mV
-16V≥VI ≥-27V
-
-
200
mV
1.0mA≤ IO ≤100mA
-
-
100
mV
1.0mA≤ IO ≤40mA
-
-
50
mV
-14.5V >VI > -27V, 1.0mA ≤IO ≤ 40mA -11.4
-
-12.6
V
VI = -19V, 1.0mA ≤ IO ≤ 70mA
V
-11.4
-
-12.6
TJ = +25 °C
-
-
6.0
TJ = +125 °C
-
-
6.5
mA
with line
∆IQ
-16V ≥ VI ≥ -27V
-
-
1.5
mA
with load
∆IQ
1.0mA ≤ IO ≤ 40mA
-
-
0.1
mA
VN
TA = +25°C,10Hz ≤ f ≤ 100KHz
-
80
-
µV
Ripple Rejection
RR
f = 120Hz, -15V ≥ VI ≥ -25V
TJ = +25°C
37
42
-
dB
Dropout Voltage
VD
TJ = +25°C
-
1.7
-
V
Quiescent Current
Change
Output Noise Voltage
Note
1. Load and line regulation are specified at constant junction temperature. Change in VO due to heating effects must be taken
into account separately. Pulse testing with low duty is used.
4
KA79LXXA
Electrical Characteristics(KA79L15A)
(VI = -23V, IO = 40mA, CI = 0.33µF, CO = 0.1µF, 0°C ≤TJ ≤ +125°C, unless otherwise specified)
Parameter
Output Voltage
Line Regulation (Note1)
Load Regulation (Note1)
Output Voltage
Quiescent Current
Symbol
Conditions
VO
TJ = +25 °C
∆VO
TJ = +25 °C
∆VO
TJ = +25 °C
VO
IQ
Min.
Typ.
Max.
-14.4 -15.0 -15.6
Unit
V
-17.5V ≥ VI ≥ -30V
-
-
300
mV
-20V ≥ VI ≥ -30V
-
-
250
mV
1.0mA ≤ IO ≤ 100mA
-
-
150
mV
1.0mA ≤ IO ≤ 40mA
-
-
75
mV
-17.5V ≥ VI ≥ -30V, 1.0mA ≤ IO ≤ 40mA
-14.25
-
-15.75
V
VI = -23V, 1.0mA ≤ IO ≤ 70mA
V
-14.25
-
-15.75
TJ = +25°C
-
-
6.0
TJ = +125°C
-
-
6.5
mA
Quiescent Current with line
Change
with load
∆IQ
-20V ≥ VI ≥ -30V
-
-
1.5
mA
∆IQ
1.0mA ≤ IO ≤ 40mA
-
-
0.1
mA
Output Noise Voltage
VN
TA = +25°C,10Hz ≤ f ≤ 100KHz
-
90
-
µV
Ripple Rejection
RR
f = 120Hz, -18.5V ≥ VI ≥ -28.5V
TJ = +25°C
34
39
-
dB
Dropout Voltage
VD
TJ = +25°C
-
1.7
-
V
Note
1. Load and line regulation are specified at constant junction temperature. Change in VO due to heating effects must be taken
into account separately. Pulse testing with low duty is used.
5
KA79LXXA
Electrical Characteristics(KA79L18A)
(VI = -27V, IO = 40mA, CI = 0.33µF, CO = 0.1µF, 0°C ≤TJ ≤ +125°C, unless otherwise specified)
Parameter
Symbol
Output Voltage
Line Regulation (Note1)
Load Regulation (Note1)
Output Voltage
VO
TJ = +25 °C
∆VO
TJ = +25 °C
∆VO
TJ = +25 °C
VO
Quiescent Current
Conditions
IQ
Min. Typ.
Max.
-17.3 -18.0 -18.7
Unit
V
-20.7V ≥ VI ≥ -33V
-
-
325
mV
-21V ≥ VI ≥ -33V
-
-
275
mV
1.0mA ≤ IO ≤ 100mA
-
-
170
mV
1.0mA ≤ IO ≤ 40mA
-
-
85
mV
-20.7V > VI > -33V, 1.0mA ≤ IO ≤ 40mA -17.1
-
-18.9
V
VI = -27V, 1.0mA ≤ IO ≤ 70mA
V
-17.1
-
-18.9
TJ = +25°C
-
-
6.5
TJ = +125°C
-
-
6.0
mA
with line
∆IQ
-21V ≥ VI ≥ -33V
-
-
1.5
mA
with load
∆IQ
1.0mA ≤ IO ≤ 40mA
-
-
0.1
mA
VN
TA =+25°C,10Hz ≤ f ≤ 100KHz
-
150
-
µV
Ripple Rejection
RR
f = 120Hz, -23V ≥ VI ≥ -33V
TJ = +25°C
33
48
-
dB
Dropout Voltage
VD
TJ = +25°C
-
1.7
-
V
Quiescent Current
Change
Output Noise Voltage
Note
1. Load and line regulation are specified at constant junction temperature. Change in VO due to heating effects must be taken
into account separately. Pulse testing with low duty is used.
6
KA79LXXA
Electrical Characteristics(KA79L24A)
(VI = -33V, IO = 40mA, CI = 0.33µF, CO = 0.1µF, 0°C ≤TJ ≤ +125°C, unless otherwise specified)
Parameter
Symbol
Output Voltage
Line Regulation (Note1)
Load Regulation (Note1)
Output Voltage
Min.
Typ.
Max.
Unit
-23
-24
-25
V
-27V ≥ VI ≥ -38V
-
-
350
mV
-28V ≥ VI ≥ -38V
-
-
300
mV
1.0mA ≤ IO ≤100mA
-
-
200
mV
1.0mA ≤ IO ≤ 40mA
-
-
100
mV
-27V ≥ VI ≥ -38V, 1.0mA ≤ IO ≤ 40mA
-22.8
-
-25.2
V
VI = -33V, 1.0mA ≤ IO ≤ 70mA
V
VO
TJ = +25 °C
∆VO
TJ = +25 °C
∆VO
TJ = +25 °C
VO
Quiescent Current
Conditions
IQ
-22.8
-
-25.2
TJ = +25°C
-
-
6.5
TJ = +125°C
-
-
6.0
mA
with line
∆IQ
-28V ≥ VI ≥ -38V
-
-
1.5
mA
with load
∆IQ
1.0mA ≤ IO ≤ 40mA
-
-
0.1
mA
VN
TA = +25°C,10Hz ≤ f ≤100KHz
-
200
-
µV
Ripple Rejection
RR
f = 120Hz, -29V ≥ VI ≥ -35V
TJ = +25°C
31
47
-
dB
Dropout Voltage
VD
TJ = +25°C
-
1.7
-
V
Quiescent Current
Change
Output Noise Voltage
Note
1. Load and line regulation are specified at constant junction temperature. Change in VO due to heating effects must be taken
into account separately. Pulse testing with low duty is used.
7
KA79LXXA
Typical Application
Design Considerations
The KA79LXXA Series of fixed voltage regulators are designed with Thermal Overload Protection that shuts down the circuit
when subjected to an excessive power overload condition. Internal Short Circuit Protection that limits the maximum current
the circuit will pass. In many low current applications, compensation capacitors are not required. However, it is recommended
that the regulator input be bypassed with a capacitor if the regulator is connected to the power supply filter with long wire
lengths, or if the output load capacitance is large. An input bypass capacitor should be selected to provide good high frequency
characteristics to insure stable operation under all load conditions. A 0.33µF or larger tantalum, mylar, or other capacitor having low internal impedance at high frequencies should be chosen. The bypass capacitor should be mounted with the shortest
possible leads directly across the regulator's input terminals. Normally good construction techniques should be used to minimize ground loops and lead resistance drops since the regulator has no external sense lead. Bypassing the output is also recommended.
I
Figure 1. Positive And Negative Regulator
Figure 2. Typical Application
A common ground is required between the input and the output voltages. The input voltage must remain typically 2.0V above
the output voltage even during the low point on the input ripple voltage.
* C1 is required if regulator is located an appreciable distance from power supply filter.
* CO improves stability and transient response.
8
KA79LXXA
Mechanical Dimensions
Package
TO-92
+0.25
4.58 ±0.20
4.58 –0.15
14.47 ±0.40
0.46 ±0.10
1.27TYP
[1.27 ±0.20]
1.27TYP
[1.27 ±0.20]
+0.10
0.38 –0.05
(0.25)
+0.10
0.38 –0.05
1.02 ±0.10
3.86MAX
3.60 ±0.20
(R2.29)
9
KA79LXXA
Mechanical Dimensions(Continued)
Package
8-SOP
MIN
#5
10
°
0~
8
+0.10
0.15 -0.05
+0.004
0.006 -0.002
3.95 ±0.20
0.156 ±0.008
5.72
0.225
0.50 ±0.20
0.020 ±0.008
1.80
MAX
0.071
MAX0.10
MAX0.004
6.00 ±0.30
0.236 ±0.012
0.41 ±0.10
0.016 ±0.004
#4
1.27
0.050
#8
5.13
MAX
0.202
#1
4.92 ±0.20
0.194 ±0.008
(
0.56
)
0.022
1.55 ±0.20
0.061 ±0.008
0.1~0.25
0.004~0.001
KA79LXXA
Mechanical Dimensions (Continued)
Package
SOT-89
1.50 ±0.20
4.50 ±0.20
(0.40)
(1.10)
2.50 ±0.20
C0.2
4.10 ±0.20
(0.50)
1.65 ±0.10
0.50 ±0.10
0.40 ±0.10
0.40
+0.10
–0.05
1.50 TYP 1.50 TYP
11
KA79LXXA
Ordering Information
Product Number
Package
Operating Temperature
KA79L05AZ
KA79L08AZ
KA79L12AZ
KA79L15AZ
TO-92
0 ~ + 125°C
KA79L18AZ
KA79L24AZ
12
KA79L05AD
8-SOP
KA79L05AM
SOT-89
KA79LXXA
13
KA79LXXA
DISCLAIMER
FAIRCHILD SEMICONDUCTOR RESERVES THE RIGHT TO MAKE CHANGES WITHOUT FURTHER NOTICE TO ANY
PRODUCTS HEREIN TO IMPROVE RELIABILITY, FUNCTION OR DESIGN. FAIRCHILD DOES NOT ASSUME ANY
LIABILITY ARISING OUT OF THE APPLICATION OR USE OF ANY PRODUCT OR CIRCUIT DESCRIBED HEREIN; NEITHER
DOES IT CONVEY ANY LICENSE UNDER ITS PATENT RIGHTS, NOR THE RIGHTS OF OTHERS.
LIFE SUPPORT POLICY
FAIRCHILD’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES
OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF FAIRCHILD SEMICONDUCTOR
CORPORATION. As used herein:
1. Life support devices or systems are devices or systems
which, (a) are intended for surgical implant into the body,
or (b) support or sustain life, and (c) whose failure to
perform when properly used in accordance with
instructions for use provided in the labeling, can be
reasonably expected to result in a significant injury of the
user.
2. A critical component in any component of a life support
device or system whose failure to perform can be
reasonably expected to cause the failure of the life support
device or system, or to affect its safety or effectiveness.
www.fairchildsemi.com