SENSORTECHNICS KTUM6010G4CXS

KTE6000 / KTU6000...CS Series
OEM submersible pressure transducers
FEATURES
· 0...250 to 0...5000 mbar,
0...5 to 0...70 psi gage
· For corrosive media
· 4...20 mA output
· Field interchangeable
MEDIA COMPATIBILITY
Wetted materials:
stainless steel 1.4404 (316L), ceramic Al2O3, PVC,
PUR, NBR11
Housing:
protection class IP 68 (according to DIN EN 60529)
respectively NEMA 6P1
ELECTRICAL CONNECTION
SPECIFICATIONS9,10
Maximum ratings
Supply voltage2
(reverse polarity protection)
Temperature limits
Storage
Operating
Compensated
12...30 V
+Vs
+12 V to 30 V
red
-40 to 85°C
-25 to 85°C
0 to 70°C
sensor
V
-Vs
Vibration (5 to 500 Hz)
Mechanical shock
10 gRMS
black
RL
GND
50 g
bare
Proof pressure3
August 2008 / 595
2 x rated pressure
1/4
www.sensortechnics.com
KTE6000 / KTU6000...CS Series
OEM submersible pressure transducers
PERFORMANCE CHARACTERISTICS
(unless otherwise noted, VS = 15 V, RL = 100 Ω, tamb = 25°C)
Characteristics
Operating pressure
Min.
KTEM6250...
KTEM6400...
KTEM6600...
KTEM61K0...
KTEM61K6...
KTEM62K0...
KTEM65K0...
KTU6005...
KTU6010...
KTU6015...
KTU6020...
KTU6030...
KTU6070...
Zero pressure offset
7
Full scale span
Thermal effects (0 to 70°C)4
Thermal effects (-25 to 0°C, 70 to 85°C)
Offset (250 mbar/5 psi)
Offset (< 1 bar/15 psi)
Offset (all others)
Span
Offset (<1 bar/15 psi)
Offset (all others)
Span
Non-linearity, hysteresis (BSL) and repeatability5
Typ.
0
0
0
0
0
0
0
0
0
0
0
0
0
250
400
600
1000
1600
2000
5000
5
10
15
20
30
70
3.8
4.0
4.2
15.8
16.0
16.2
0.04
0.03
0.02
0.02
0.06
0.03
0.03
0.08
0.06
0.04
0.04
±0.1
±0.3
Output noise (0 < f < 1 kHz)
±0.04
Long term stability6
±0.2
Response time (10 to 90 %)
Power supply rejection
Power consumption (IL = 20 mA)
1
Offset
Span
Max.
Unit
mbar
p si
mA
%FSO/°C
%FSO
5
ms
0.05
0.05
%FSO/V
260
mW
Specification notes (for all devices):
1. The package is an all-sealed housing. For proper function the gage port is vented to the atmosphere through the connecting
cable. Thus the vent tube of the cable end must have access to the ambient pressure.
2. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the
load limitation diagram.
3. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element.
4. Thermal effects tested and guaranteed from 0°C to 70°C relative to 25°C. All specifications shown are relative to 25°C.
5. Non-linearity refers to the Best Straight Line fit measured for offset, full scale span and 1/2 full scale span.
6. Long term stability is the change in output after one year or 1 million pressure cycles.
7. Span is the arithmetic difference in transmitter output signal measured at zero pressure and the maximum operating pressure.
8. Tests are in accordance with EN61000-6-2, April 99.
9. CE-labelling is in accordance with 89/336/EEC.
10. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC.
11. Other sealing materials are available on request.
August 2008 / 595
2/4
www.sensortechnics.com
KTE6000 / KTU6000...CS Series
OEM submersible pressure transducers
ELECTROMAGNETIC CAPABILITY8
Test conditions
Criterion
Interference
Grade 3
10 V/m, 80 MHz to 1000 MHz
80 % AMC (1 kHz)
A
<1 % FSO
Radiated, radio frequency
electromagnetic field
immunity (RFI)
EN61000-4-3:
Electrical fast transient /
burst immunity (EFT)
EN61000-4-4:
Grade 3
±2 kV
B
<1 % FSO
Electrostatic discharge
immunity test (ESD)
EN61000-4-2:
Grade 4
±8 kV, contact discharge
B
<1 % FSO
Immunity to conducted
disturbances induced by
radio-frequency fields
EN61000-4-6:
Grade 3
0,15 to 80 MHz
10 V, 80 % AMC (1 kHz)
A
<1 % FSO
LOAD LIMITATION
1400
Ohm
1200
1000
800
op
e
ra ratin
ng g
e
600
400
200
0
August 2008 / 595
5
12 15 18
25
30 V
supply voltage
3/4
www.sensortechnics.com
KTE6000 / KTU6000...CS Series
OEM submersible pressure transducers
OUTLINE DRAWING
NOM 134
(5.28)
NOM 2000
(78.74)
NOM 70
(2.76)
Ø 27
(1.06)
Ø 24
(0.95)
other cable lengths
on request
Hydrophobic filter
(incl. in delivery)
WIRE CONNECTION
mass: typ. 350 g (without cable)
Color
Electrical connection
red
+Vs
black
-Vs
transparent
vent tube1
bare
case/shield
dimensions in mm (inches)
ORDERING INFORMATION
KTx
M
6xxx
G
4
C
x
S
calibration
E: calibration in bar
U: calibration in psi
submersible
mbar-ranges
cable version
pressure range
250: 0...250 mbar
400: 0...400 mbar
600: 0...600 mbar
1K0: 0...1000 mbar
1K6: 0...1600 mbar
2K0: 0...2000 mbar
5K0: 0...5000 mbar
Note:
cable length in m
005:
010:
015:
020:
030:
070:
0...5
0...10
0...15
0...20
0...30
0...70
output signal
4: 4...20 mA
psi
psi
psi
psi
psi
psi
pressure mode
G: gage pressure
Other pressure ranges and options are widely available.
Please contact your nearest Sensortechnics sales representative.
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the
application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
August 2008 / 595
4/4
www.sensortechnics.com