ROITHNER LD1430-C003

LD1430-C003
TECHNICAL DATA
Infrared Laser Diode
Features
•
•
•
•
Lasing Mode Structure: single mode
Peak Wavelength : typ. 1430 nm
Optical Ouput Power: 3 mW, CW
Package: 5.6 mm, flat window
Absolute Maximum Ratings (TC=15°C)
Item
CW Output Power
LD Reverse Voltage
LD Forward Current
PD Reverse Voltage
PD Forward Current
Operating Case Temperature
Storage Temperature
Symbol
PO
Vr
Iop
VrPD
IPD
TC
Tstg
Value
20
2
150
20
10
-40 … +60
-40 … +85
Unit
mW
V
mA
V
mA
°C
°C
Specifications (TC=15°C)
Item
Optical Specifications
CW Output Power
Conditions
-40 .. +60 °C
25°C, PO=3mW
Center Wavelength
-40..60°C, PO=3mW
Spectral Width
25°C, PO=3mW
Wavelength Temp. Coefficient -40..60°C, PO=3mW
FWHM Beam Divergence
Modulation Bandwidth
Resonance Frequency
25°C, PO=3mW
25°C, Iop= Ith +16mA
60°C, Iop= Ith +16mA
25°C, Iop= Ith +16mA
60°C, Iop= Ith +16mA
Symbol
Min.
Typ.
Max.
Unit
PO
3
1420
1400
4
2
-
1430
0.9
0.5
21
36
7
6
5
4
1450
1470
4
-
mW
0.16
0.12
100
-
12
19
21
29
0.32
0.29
1.1
6
250
0.1
5
18
33
40
60
1.6
700
1.0
10
λC
Δλ
Δλ / ΔT
Θ║
Θ┴
f-3dB
fr
nm
nm
nm/K
deg.
deg.
GHz
GHz
Electrical Specifications
Threshold Current
Operating Current
Slope Efficiency
Operating Voltage
Serial resistance
Monitor Current
Monitor Dark Current
Monito Capacitance
25 °C
60 °C
25°C, PO=3mW
60°C, PO=3mW
25°C, PO=3mW
60°C, PO=3mW
25°C, PO=3mW
25°C, PO=3mW
25°C, PO=3mW
25°C, VRPD=5V
F=1MHz, VRPD=5V
Ith
Iop
η
Vop
RS
Im
Id
Cm
mA
mA
W/A
V
Ω
µA
µA
pF
The above specifications are for reference purpose only and subjected to change without prior notice.
13.09.2011
LD1430-C003
1 of 4
Package Dimensons
5.6 mm Package (Unit:mm)
Bottom View
PIN
1
2
3
4
13.09.2011
LD1430-C003
Funciton
Case, LD Anode
PD Anode
PD Cathode
LD Cathode
2 of 4
Typical Performance Curves
13.09.2011
LD1430-C003
3 of 4
Safety of Laser light
•
•
Laser Light can damage the human eyes and skin. Do not expose the
eye or skin directly to any laser light and/or through optical lens. When
handling the LDs, wear appropriate safety glasses to prevent laser
light, even any reflections from entering to the eye. Focused laser
beam through optical instruments will increase the chance of eye
hazard.
The LD emitts invisible light
Cautions
1. Operating methode
• This LD shall change its forward voltage requirement and optical ouput power according to
temperature change. Also, the LD will require more operation current to maintain same ouput
power as it degrades. In order to maintain output power, use of APC (Automatic Power
Control) is recommended. Which use monitor feedback to adjust the operation current.
• Confirm that electrical spike current generated by switching on and off does not exceed the
maximum operating current level specified herein above as absolute maximum rating. Also,
employ appropriat countermeasures to reduce chattering and/or overshooting in the circuit.
2. Static Electricity
• Static electricity or electrical surges will reduce and degrade the reliability of the LDs. It is
recommended to use a wrist trap or anti-electrostatic glove when handeling the product.
3. Absolute Maximum Rating
• Active layer of LDs shall have high current density and generate high electric field during its
operation. In order to prevent excessive damage, the LD must be operated striclty below
absolute maximum rating.
13.09.2011
LD1430-C003
4 of 4