MEANWELL LPF-40D-12

LPF-40D
40W Single Output Switching Power Supply
series
Features :
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
High efficiency up to 89%
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
Fully isolated plastic case
Fully encapsulated with IP67 level (Note.6)
Class
power unit, no FG
Built-in 3 in 1 dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
3 years warranty
F
110
M
M
IP67
SELV
( for 48V,54V only)
( except for 48V,54V )
SPECIFICATION
LPF-40D-12 LPF-40D-15 LPF-40D-20 LPF-40D-24 LPF-40D-30 LPF-40D-36 LPF-40D-42 LPF-40D-48 LPF-40D-54
MODEL
12V
DC VOLTAGE
CONSTANT CURRENT REGION Note.4 7.2 ~12V
OUTPUT
24V
30V
36V
42V
48V
54V
12 ~ 20V
14.4 ~ 24V
21.6 ~ 36V
25.2 ~ 42V
28.8 ~ 48V
32.4 ~ 54V
1.12A
0.96A
0.84A
0.76A
RATED CURRENT
3.34A
2.67A
2A
1.67A
RATED POWER
40.08W
40.08W
40W
40.08W
40.2W
40.32W
40.32W
40.32W
41.04W
150mVp-p
150mVp-p
150mVp-p
200mVp-p
250mVp-p
250mVp-p
250mVp-p
350mVp-p
RIPPLE & NOISE (max.) Note.2 150mVp-p
VOLTAGE TOLERANCE Note.3
4.0%
4.0%
4.0%
4.0%
4.0%
4.0%
4.0%
4.0%
4.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
2.0%
1.5%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
Note.7 1000ms, 80ms / 115VAC at full load
16ms/230VAC
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.5 90 ~ 305VAC
1000ms, 80ms / 230VAC
16ms/115VAC at full load
127 ~ 431VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.97/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
EFFICIENCY (Typ.)
84%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
OVER CURRENT
86%
85%
0.6A / 115VAC
0.3A / 230VAC
COLD START 75A/230VAC
87%
88%
88%
88.5%
89%
89%
54 ~ 63V
59 ~ 66V
<0.75mA / 240VAC
LEAKAGE CURRENT
Note.4
SHORT CIRCUIT
PROTECTION
20V
9 ~ 15V
18 ~ 30V
1.34A
SETUP, RISE TIME
INPUT
15V
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed.
34 ~ 40V
15 ~ 17V
17.5 ~ 21V 23 ~ 27V
28 ~ 35V
41 ~ 49V
46 ~ 54V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
90
10
(RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
-40 ~ +70
(Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80
0.03%/
, 10 ~ 95% RH
(0 ~ 50
)
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS Note.6 UL8750, EN61347-1, EN61347-2-13 independent, J61347-1, J61347-2-13, IP67 approved ; Design refer to UL60950-1, TUV EN60950-1
SAFETY &
EMC
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC
ISOLATION RESISTANCE
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
NOTE
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level(surge 2KV), criteria A
394.9Khrs min. MIL-HDBK-217F (25 )
162.5*43*32mm (L*W*H)
0.45Kg; 32pcs/15.4Kg/0.93CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 60% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minutes.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
File Name:LPF-40D-SPEC 2011-07-28
LPF-40D
40W Single Output Switching Power Supply
Mechanical Specification
Case No.LPF-60B
series
Unit:mm
162.5
3.5
300 20
3.6
T case
3.5
300 20
60
13
3.5
SJTW 18AWG 2C
43
3.6
AC/N(Blue)
AC/L(Brown)
UL2464 18AWG 2C(+V,-V)
UL2464 22AWG 2C(DIM+,DIM-)
3.5
+V(Red)
-V(Black)
DIM+(Blue)
DIM-(White)
32
T case: Max. Case Temperature.
Block Diagram
Fosc : 100KHz
EMI FILTER
&
RECTIFIERS
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
PFC
CIRCUIT
+V
-V
DIM+
DIM-
O.L.P.
O.L.P.
DETECTION
CIRCUIT
PWM & PFC
CONTROL
O.V.P.
Derating Curve
Static Characteristics
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-40
-30
0
15
30
40
50
AMBIENT TEMPERATURE ( )
60
70 (HORIZONTAL)
60
50
40
90
100
125
135
145
155 165
175
180
200
230
305
INPUT VOLTAGE (V) 60Hz
File Name:LPF-40D-SPEC 2011-07-28
40W Single Output Switching Power Supply
LPF-40D
series
Power Factor Characteristic
Constant Current Mode
PF
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
.9 9
.9 8
.9 7
.9 6
.9 5
.9 4
.9 3
.9 2
.9 1
0 .9
.8 9
.8 8
.8 7
.8 6
.8 5
.8 4
277VAC
230VAC
115VAC
50%
60%
70%
80%
90%
100%
(40W)
LOAD
EFFICIENCY vs LOAD (48V Model)
EFFICIENCY (%)
LPF-40D series possess superior working efficiency that up to 89% can be reached in field applications.
93
92
91
90
89
88
87
86
85
84
83
82
81
80
79
78
77
76
75
74
73
72
71
70
277VAC
230VAC
115VAC
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
DRIVING METHODS OF LED MODULE
There are two major kinds of LED drive method "direct drive" and "with LED driver".
A typical LED power supply may either work in "constant voltage mode (CV) or constant current mode (CC)" to drive the LEDs.
Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode (with LED driver, at area (A) and CC mode (direct drive, at area (B).
(B)
Constant
Current area
Vo(%)
100
(A) Constant
Voltage area
60
(max.)
(C)
Hiccup
Protection
50
95
Io (%)
Typical LED power supply I-V curve
File Name:LPF-40D-SPEC 2011-07-28
LPF-40D
40W Single Output Switching Power Supply
series
DIMMING OPERATION
AC/N(Blue)
AC/L(Brown)
+V(Red)
-V(Black)
DIM+(Blue)
DIM-(White)
LPF-40D
Built-in 3 in 1 dimming function, o utput constant current level can be adjusted through output cable by 1 ~ 10Vdc, 10V PWM signal or resistance
between DIM+ and DIM-.
Please DO NOT connect "DIM-" to "-V".
Reference resistance value for output current adjustment (Typical)
Resistance value
Output current
20K
10K
10%
20%
30K
30%
40K
40%
50K
60K
50%
60%
70K
70%
80K
80%
90K
100K
90%
100%
OPEN
100%~108%
1 ~ 10V dimming function for output current adjustment (Typical)
Dimming value
1V
2V
3V
4V
5V
6V
7V
8V
9V
10V
OPEN
Output current
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
100%~108%
10V PWM signal for output current adjustment (Typical): Frequency range :100Hz ~ 3KHz
Duty value
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
OPEN
Output current
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
100%~108%
Using the built-in dimming function on LPF-40D can't turn the lighting fixture totally dark. Please refer to the connection method below to
achieve 0% brightness of the lighting fixture connecting to the LED power supply unit.
Dimming connection diagram for turning the lighting fixture ON/OFF :
N
L
Switch
Relay
Adjuster
0~100K Ohms resistance
1~10V DC Voltage
10V PWM Signal
Brown
Blue
AC/L
LPF-40D
AC/N
DIM+
DIMV(-)
V(+)
Blue
White
Black
Red
LED Lighting Fixture
Using a switch and relay can turn ON/OFF the lighting fixture.
1.Output constant current level can be adjusted through output cable by connecting a resistor or 1~10Vdc or 10V PWM signal between DIM+ and DIM-.
2.The LED lighting fixture can be turned ON/OFF by the switch.
File Name:LPF-40D-SPEC 2011-07-28