FEDS82V48540-01 OKI Semiconductor MS82V48540 Issue Date:Nov. 8, 2002 393,216-Word × 32-Bit × 4-Bank FIFO-SGRAM GENERAL DESCRIPTION The MS82V48540 is a 48-Mbit system clock synchronous dynamic random access memory. In addition to the conventional random read/write access function, the MS82V48540 provides the automatic row address increment function and automatic bank switching function. Therefore, if once the row and column addresses are set, continuous serial accesses are possible while banks are automatically switched till input of the Precharge command. The MS82V48540 is ideal for digital camera and TV buffer memory applications. FEATURES • • • • • • • • • • 393,216 words × 32 bits × 4 banks memory (1,536 rows × 256 columns × 32 bits × 4 banks) Single 3.3 V ±0.3 V power supply LVTTL compatible inputs and outputs Programmable burst length (1, 2, 4, 8 and full page) Programmable CAS latency (2, 3) Automatic row address increment function and automatic bank switching function Power Down operation and Clock Suspend operation 3,072 refresh cycles/64 ms Auto refresh and self refresh capability Package: 86-pin 400 mil plastic TSOP (II) (TSOPII86-P-400-0.50-K) (Product : MS82V48540-xTA) x indicates speed rank. PRODUCT FAMILY Family Max. Operating Frequency Access Time MS82V48540-7 143 MHz 5 ns MS82V48540-8 125 MHz 6 ns Package 86-pin Plastic TSOP (II) (400 mil) 1/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 PIN CONFIGURATION (TOP VIEW) VCC DQ0 VCCQ DQ1 DQ2 VSSQ DQ3 DQ4 VCCQ DQ5 DQ6 VSSQ DQ7 NC VCC DQM0 WE CAS RAS CS NC BA0 BA1 A10/AP A0 A1 A2 DQM2 VCC NC DQ16 VSSQ DQ17 DQ18 VCCQ DQ19 DQ20 VSSQ DQ21 DQ22 VCCQ DQ23 VCC 1 86 2 85 3 84 4 83 5 82 6 81 7 80 8 79 9 78 10 77 11 76 12 75 13 74 14 73 15 72 16 71 17 70 18 69 19 68 20 67 21 66 22 65 23 64 24 63 25 62 26 61 27 60 28 59 29 58 30 57 31 56 32 55 33 54 34 53 35 52 36 51 37 50 38 49 39 48 40 47 41 46 42 45 43 44 VSS DQ15 VSSQ DQ14 DQ13 VCCQ DQ12 DQ11 VSSQ DQ10 DQ9 VCCQ DQ8 NC VSS DQM1 NC NC CLK CKE A9 A8 A7 A6 A5 A4 A3 DQM3 VSS NC DQ31 VCCQ DQ30 DQ29 VSSQ DQ28 DQ27 VCCQ DQ26 DQ25 VSSQ DQ24 VSS 86-Pin Plastic TSOP (II) (Type K) Pin Name Function A0 – A10 Row Address Inputs A0 – A7 Column Address Inputs BA0, BA1 Bank Address Pin Name WE DQM0 – DQM3 DQ0 – DQ31 Function Write Enable DQ Mask Enable Data Inputs/outputs CLK System Clock Input VCC Supply Voltage CKE Clock Enable VSS Ground CS Chip Select VCCQ Supply Voltage for DQ RAS Row Address Strobe VSSQ Ground for DQ CAS Column Address Strobe NC No Connection Note: The same power supply voltage must be provided to every VCC pin and VCCQ pin. The same GND voltage level must be provided to every VSS pin and VSSQ pin. 2/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 BLOCK DIAGRAM CKE CLK CS RAS CAS WE DQM0 to DQM3 I/O Timing Controller Register Bank Controller BA0, BA1 Internal Column Address Counter Column 8 Address Buffers Internal Input Row Data Address Counter Register Column Decoders Input 32 Buffers 32 11 Address Buffers Word Drivers Sense Amplifiers Row Row Decoders A0 to A10 BA0, BA1 12Mb Memory Cells Bank A Bank B Bank C Bank D Read 32 Data Register 32 Output Buffers 32 DQ0 to DQ31 3/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 PIN DESCRIPTION CLK Fetches all inputs at the "H" edge. CS Disables or enables device operation by asserting or deactivating all inputs except CLK, CKE, DQM0, DQM1, DQM2 and DQM3. CKE Masks system clock to deactivate the subsequent CLK operation. If CKE is deactivated, system clock will be masked so that the subsequent CLK operation is deactivated. CKE should be asserted at least one cycle prior to a new command. Address Row & column multiplexed. Row address: RA0 – RA10 Column address: CA0 – CA7 BA0, BA1 Selects bank to be activated during row address latch time and selects bank for precharge and read/write during column address latch time. BA0 = “L”, BA1 = “L”: Bank A BA0 = “H”, BA1 = “L”: Bank B BA0 = “L”, BA1 = “H”: Bank C BA0 = “H”, BA1 = “H”: Bank D RAS CAS WE Functionality depends on the combination. For details, see the function truth table. DQM0 – DQM3 Masks the read data of two clocks later when DQM0 - DQM3 are set "H" at the "H" edge of the clock signal. Masks the write data of the same clock when DQM0 - DQM3 are set "H" at the "H" edge of the clock signal. DQM0 controls DQ0 to DQ7, DQM1 controls DQ8 to DQ15, DQM2 controls DQ16 to DQ23, and DQM3 controls DQ24 to DQ31. DQ0 – DQ31 Data inputs/outputs are multiplexed on the same pin. *Notes: 1. When CS is set "High" at a clock transition from "Low" to "High", all inputs except CLK, CKE, DQM0, DQM1, DQM2, and DQM3 are invalid. 2. When issuing an active, read or write command, the bank is selected by BA0 and BA1. BA0 BA1 Active, read or write 0 0 Bank A 1 0 Bank B 0 1 Bank C 1 1 Bank D 3. The auto precharge function is enabled or disabled by the A10/AP input when the read or write command is issued. A10/AP BA0 BA1 0 0 0 After the end of burst, bank A holds the active status. Operation 1 0 0 After the end of burst, bank A is precharged automatically. 0 1 0 After the end of burst, bank B holds the active status. 1 1 0 After the end of burst, bank B is precharged automatically. 0 0 1 After the end of burst, bank C holds the active status. 1 0 1 After the end of burst, bank C is precharged automatically. 0 1 1 After the end of burst, bank D holds the active status. 1 1 1 After the end of burst, bank D is precharged automatically. 4/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 4. When issuing a precharge command, the bank to be precharged is selected by the A10/AP, BA0 and BA1 inputs. A10/AP BA0 BA1 0 0 0 Bank A is precharged. Operation 0 1 0 Bank B is precharged. 0 0 1 Bank C is precharged. 0 1 1 Bank D is precharged. 1 × × All banks are precharged. 5/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 COMMAND OPERATION Mode Register Set Command (CS, RAS, CAS, WE = “Low”) The MS82V48540 has the mode register that defines the operation mode “CAS Latency, Burst Length, Burst Sequence”. The Mode Register Set command should be executed just after the MS82V48540 is powered on. Before entering this command, all banks must be precharged. Next command can be issued after tRSC. Auto Refresh Command (CS, RAS, CAS = “Low”, WE = “High”) The Auto Refresh command performs refresh automatically by the address counter. The refresh operation must be performed 3,072 times within 64 ms and the next command can be issued after tRC from last Auto Refresh command. Before entering this command, all banks must be precharged. Self Refresh Entry/Exit Command (CS, RAS, CAS, CKE = “Low”, WE = “High”) The self refresh operation continues after the Self Refresh Entry command is entered, with CKE level left “low”. This operation terminates by making CKE level “high”. The self refresh operation is performed automatically by the internal address counter on the MS82V48540 chip. In self refresh mode, no external refresh control is required. Before entering self refresh mode, all banks must be precharged. Next command can be issued after tRC. Single Bank Precharge Command (CS, RAS, WE, A10/AP = “Low”, CAS = “High”) The Single Bank Precharge command triggers bank precharge operation. Precharge bank is selected by BA0 and BA1. All Banks Precharge Command (CS, RAS, WE = “Low”, CAS, A10/AP = “High”) The All Bank Precharge command triggers precharge of all banks. If this command is executed during special bank active mode, the special bank active mode is terminated. Bank Active Command (CS, RAS = “Low”, CAS, WE = ”High”) The Bank Active command activates the bank selected by BA0 and BA1. The Bank Active command corresponds to conventional DRAM's RAS falling operation. Row addresses “A0 – A10, BA0 and BA1” are strobed. Write Command (CS, CAS, WE, A10/AP = “Low”, RAS = “High”) The Write command is required to begin burst write operation. Then burst access initial bit column address is strobed. Write with Auto Precharge Command (CS, CAS, WE = “Low”, RAS, A10/AP = “High”) The Write with Auto Precharge command is required to begin burst write operation with automatic precharge after the burst write. Any command that interrupts this operation cannot be issued. Read Command (CS, CAS, A10/AP = “Low”, RAS, WE = “High”) The Read command is required to begin burst read operation. Then burst access initial bit column address is strobed. 6/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 Read with Auto Prechaege Command (CS, CAS = “Low”, RAS, WE, A10/AP = “High”) The Read with Auto Precharge command is required to begin burst read operation with auto precharge after the burst read. Any command that interrupts this operation cannot be issued. No Operation Command (CS = “Low”, RAS, CAS, WE = “High”) The No Operation command does not trigger any operation. Device Deselect Command (CS = “High”) The Device Deselect command disables the RAS, CAS, WE and Address input. This command does not trigger any operation. Data Write/Output Enable Command (DQMi = “Low”) The Data Write/Output Enable command enables DQ0 - DQ31 in read or write. The each DQM0, 1, 2 and 3 corresponds to DQ0 - DQ7, DQ8 - DQ15, DQ16 - DQ23 and DQ24 - DQ31 respectively. Data Mask/Output Disable Command (DQMi = “High”) The Data Mask/Output Disable command disables DQ0 - DQ31 in read or write. In read cycle output buffers are disabled after 2 clocks . In write cycle input buffers are disabled at the same clock. The each DQM0, 1, 2 and 3 corresponds to DQ0 - DQ7, DQ8 - DQ15, DQ16 - DQ23 and DQ24 - DQ31 respectively. Burst Stop Command (CS, WE = “Low”, RAS, CAS = “High”) The Burst Stop command stops burst access. After the Burst Stop command is entered, the output buffer goes into high impedance state. 7/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 SPECIAL READ/WRITE OPERATION The special read or write operation is activated by executing the Read or Write command after selecting the special page mode with the Mode Register command. The automatic bank switching and automatic row address increment operations are activated by executing the Bank Active command during Special Page mode, and the serial access starts from the address fetched with the Read or Write command. The burst operation starts from the start address toward the column. When the last column address is reached, the bank is automatically switched and the row address is also automatically incremented and the serial access continues from the start column address. The automatic bank switching and automatic row address increment operations continue until the All Bank Precharge command is executed each time the last column address is reached. Since the bank switching and row address increment are automatically made during the special read or write operation, the row address proceeds as shown in the following figure. 0 1535 256 1535 256 0 Bank B BA0 = “H”, BA1 = “L” 0 3073 3075 3077 3079 Start address 6143 Bank A BA0 = “L”, BA1 = “L” Row 6144 1535 256 0 Bank C BA0 = “L”, BA1 = “H” Column ➀ ➂ ➄ ➆ 0 3174 3076 3078 3080 1535 256 0 Operation is ended by input of All Bank Precharge command. Bank D BA0 = “H”, BA1 = “H” 0 3071 ➁ ➃ ➅ ➇ 0 3072 Note) The circled numbers indicate the orders of row address increment. 8/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 TRUTH TABLE Command Truth Table Address CS RAS CAS WE BA0, 1 A10/AP A9 – A0 Device Deselect H × × × × × × No Operation L H H H × × × Mode Register Set L L L L Auto Refresh L L L H × Bank Activate L L H H BA Read L H L H BA L CA (A7 – A0) Read with Auto Precharge L H L H BA H CA (A7 – A0) Function OP. CODE × × RA Write L H L L BA L CA (A7 – A0) Write with Auto Precharge L H L L BA H CA (A7 – A0) Precharge Select Bank L L H L BA L × Precharge All Banks L L H L × H × Burst Stop L H H L × × × DQM Truth Table Function DQMi Data Write/Output Enable L Data Mask/Output Disable H 9/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 Function Truth Table (1/3) Note 1 Current State Idle Active (ACT) CS WE BA Address H RAS CAS × × × × × NOP L H H H × × NOP L H H L BA × ILLEGAL 2 L H L × BA CA, A10 ILLEGAL 2 L L H H BA L L L L L L L H L BA RA Action Row Active Op-Code Mode Register Write A10 NOP 4 5 L L L H × × Auto Refresh/Self refresh H × × × × × NOP L H H × × × NOP L H L H BA CA, A10 Read L H L L BA CA, A10 Write L L H H BA RA ILLEGAL L L H L BA A10 Precharge L L L × × × ILLEGAL Active (Special Page Mode) H × × × × × NOP L H H × × × NOP (SACT) L H L H BA CA Serial Read L H L L BA CA Serial Write L L H H BA RA ILLEGAL Read (RD) Write (WT) Note L L H L BA A10: L ILLEGAL L L H L BA A10: H Precharge L L L × × × ILLEGAL 2 H × × × × × NOP (Continue Row Active after Burst ends) L H H H × × NOP (Continue Row Active after Burst ends) L H H L × × Burst Stop → Row Active L H L H BA CA, A10 Term Burst, new Read 3 L H L L BA CA, A10 Term Burst, start Write 3 L L H H BA RA ILLEGAL 2 L L H L BA A10 Term Burst, execute Precharge L L L × × × ILLEGAL H × × × × × NOP (Continue Row Active after Burst ends) L H H H × × NOP (Continue Row Active after Burst ends) L H H L × × Burst Stop → Row Active L H L H BA CA, A10 Term Burst, start Read 3 L H L L BA CA, A10 Term Burst, new Write 3 L L H H BA RA ILLEGAL 2 L L H L BA A10 Term Burst, execute Precharge 3 L L L × × × ILLEGAL 10/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 Function Truth Table (2/3) Note 1 Current State CS Read with Auto Precharge (RAP) H Write with Auto Precharge (WAP) RAS CAS × WE BA Address Action × × × × NOP (Continue Burst to End and enter Precharge) L H H H × × NOP (Continue Burst to End and enter Precharge) L H H L × × ILLEGAL L H L H BA CA, A10 ILLEGAL L H L L BA CA, A10 ILLEGAL L L H H BA RA ILLEGAL 2 L L H L BA A10 ILLEGAL 2 L L L × × × ILLEGAL H × × × × × NOP (Continue Burst to End and enter Precharge) L H H H × × NOP (Continue Burst to End and enter Precharge) L H H L × × ILLEGAL L H L H BA CA, A10 ILLEGAL L H L L BA CA, A10 ILLEGAL L L H H BA RA ILLEGAL 2 L L H L BA A10 ILLEGAL 2 L L L × × × ILLEGAL Read (Special Page Mode) H × × × × × NOP (Continue serial read) L H H H × × NOP (Continue serial read) (SRD) L H H L × × ILLEGAL L H L × BA CA ILLEGAL L L H H BA RA ILLEGAL L L H L BA A10: L ILLEGAL L L H L BA A10: H Precharging Write (Special Page Mode) (SWT) Precharging (PRE) Note L L L × × × ILLEGAL H × × × × × NOP (Continue serial write) L H H H × × NOP (Continue serial write) L H H L × × ILLEGAL L H L × BA CA ILLEGAL L L H H BA RA ILLEGAL L L H L BA A10: L ILLEGAL L L H L BA A10: H Precharging L L L × × × ILLEGAL H × × × × × NOP → Idle after tRP L H H H × × NOP → Idle after tRP L H H L BA × ILLEGAL 2 L H L × BA CA ILLEGAL 2 L L H H BA RA ILLEGAL 2 L L H L BA A10 NOP 4 L L L × × × ILLEGAL 11/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 Function Truth Table (3/3) Note 1 Current State Refreshing (REF) CS WE BA Address H RAS CAS × × × × × NOP → Idle after tRC L H H H × × NOP → Idle after tRC L H H L BA × ILLEGAL L H L × BA CA ILLEGAL Action L L H H BA RA ILLEGAL L L H L BA A10 ILLEGAL L L L × × × ILLEGAL ABBREVIATIONS BA = Bank Address NOP = No Operation command RA = Row Address Note CA = Column Address Notes: 1. All inputs are enabled when CKE is set high for at least 1 cycle prior to the inputs. 2. Illegal to bank in specified state, but may be legal in some cases depending on the state of bank selection. 3. To avoid bus contention, satisfy tCCD and tDPL. 4. NOP to bank precharging or in idle state. Precharges activated bank by BA or A10/AP. 5. Illegal if any bank is not idle. 12/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 Function Truth Table for CKE Current State (n) Self Refresh (SREF) Power Down (PD) All Banks Idle (ABI) Any State Other than Listed Above Note: CKEn-1 CKEn CS RAS CAS WE Address Action H × × × × × × INVALID L H H × × × × Exit Self Refresh → ABI L H L H H H × Exit Self Refresh → ABI L H L H H L × ILLEGAL L H L H L × × ILLEGAL L H L L × × × ILLEGAL L L × × × × × NOP (Maintain Self Refresh) H × × × × × × INVALID L H H × × × × Exit Self Refresh → ABI L H L H H H × Exit Self Refresh → ABI L H L H H L × ILLEGAL L H L H L × × ILLEGAL L H L L × × × ILLEGAL Note L L × × × × × NOP (Continue power down mode) H H × × × × × Refer to Truth Table 6 H L H × × × × Enter Power Down 6 H L L H H H × Enter Power Down 6 H L L H H L × ILLEGAL 6 H L L H L × × ILLEGAL 6 H L L L H L × ILLEGAL 6 H L L L L H × Enter Self Refresh 6 H L L L L L × ILLEGAL 6 L L × × × × × NOP 6 H H × × × × × Refer to Truth Table H L × × × × × Begin Clock Suspend Next Cycle L H × × × × × Enable Clock of Next Cycle L L × × × × × Continue Clock Suspension 6. Power-down and self refresh can be entered only when all the banks are in an idle state. 13/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 Mode Set Address Keys CAS Latency Operation Code A8 A7 0 TM A6 A5 A4 CL A3 BT BT = 0 BT = 1 Reserved 0 Sequential 0 0 0 1 Reserved 0 1 Reserved 1 Interleave 0 0 1 2 Reserved 1 0 2 0 1 0 4 4 1 3 0 1 1 8 8 Mode Setting 0 0 1 0 0 1 1 Vender Use Only 0 1 0 1 Write Burst Length Burst Length 0 0 *Note 1 Burst Type 0 A2 A1 A0 1 0 0 Reserved 1 0 0 Reserved Reserved A9 Length 1 0 1 Reserved 1 0 1 Reserved Reserved 0 Burst 1 1 0 Reserved 1 1 0 Special page Reserved 1 Single Bit 1 1 1 Reserved 1 1 1 Full Page Reserved *Note 1: To select Special Page mode, set A9 to “L”. The write burst length during Special Page mode is set only for Burst. POWER ON SEQUENCE 1. With CKE = "H", DQM = "H" and the other inputs in NOP state, turn on the power supply and start the system clock. 2. After the VCC voltage has reached the specified level, pause for 200 µs or more with the input kept in NOP state. 3. Issue the precharge all bank command. 4. Apply an Auto-refresh 8 or more times. 5. Enter the mode register command. 14/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 Burst Length and Sequence BL = 2 Starting Address (column address A0, binary) Sequential Type Interleave Type 0 0, 1 Not supported 1 1, 0 Not supported Starting Address (column address A1, A0, binary) Sequential Type Interleave Type 00 0, 1, 2, 3 0, 1, 2, 3 01 1, 2, 3, 0 1, 0, 3, 2 10 2, 3, 0, 1 2, 3, 0, 1 11 3, 0, 1, 2 3, 2, 1, 0 Starting Address (column address A2 - A0, binary) Sequential Type Interleave Type 000 0, 1, 2, 3, 4, 5, 6, 7 0, 1, 2, 3, 4, 5, 6, 7 001 1, 2, 3, 4, 5, 6, 7, 0 1, 0, 3, 2, 5, 4, 7, 6 010 2, 3, 4, 5, 6, 7, 0, 1 2, 3, 0, 1, 6, 7, 4, 5 011 3, 4, 5, 6, 7, 0, 1, 2 3, 2, 1, 0, 7, 6, 5, 4 100 4, 5, 6, 7, 0, 1, 2, 3 4, 5, 6, 7, 0, 1, 2, 3 101 5, 6, 7, 0, 1, 2, 3, 4 5, 4, 7, 6, 1, 0, 3, 2 110 6, 7, 0, 1, 2, 3, 4, 5 6, 7, 4, 5, 2, 3, 0, 1 111 7, 0, 1, 2, 3, 4, 5, 6 7, 6, 5, 4, 3, 2, 1, 0 BL = 4 BL = 8 BL = Special, Full : Sequential only 15/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 READ/WRITE COMMAND INTERVAL Read to Read Command Interval BL = 4, CL = 2 0 1 2 3 4 5 6 7 8 CLK RD-A RD-B QA1 DQ QB1 QB2 QB3 Hi-Z QB4 1cycle Write to Write Command Interval BL = 4, CL = 2 0 1 2 3 4 5 6 7 8 CLK WT-A WT-B DB1 DA1 DQ DB3 DB2 Hi-Z DB4 1cycle Write to Read Command Interval BL = 4 0 1 2 3 4 5 6 7 8 CLK CL = 2 DQ CL = 3 DQ WT-A RD-B DA1 Hi-Z QB1 QB2 QB3 QB4 QB1 QB2 QB3 WT-A RD-B DA1 Hi-Z QB4 1cycle 16/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 Read to Write Command Interval BL = 4, CL = 2, 3 0 1 2 3 4 5 6 5 6 7 8 CLK CL = 2, 3 RD-A WT-B DQM DQ Hi-Z DB1 DB2 DB3 DB4 1cycle BL = 4, CL = 2, 3 0 1 2 3 4 7 8 CLK CL = 2 WT-B RD-A DQM DQ CL = 3 Hi-Z QA1 QA2 QA3 DB1 DB2 Hi-Z is necessary WT-B QA1 QA2 RD-A DQM DQ Hi-Z DB1 DB2 Hi-Z is necessary 17/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 BURST TERMINATION Burst Read Termination by Precharging in READ Cycle BL = 2, 4, 8, Full 0 1 2 3 4 5 6 7 8 CLK tRP RD CL = 2 PRE Q1 DQ Q2 Q3 ACT Hi-Z Q4 tRP RD CL = 3 PRE Q1 DQ Q2 ACT Q3 Hi-Z Q4 Burst Read Termination by Precharging in WRITE Cycle BL = 2, 4, 8, Full 0 1 2 3 4 5 6 7 8 CLK tRP CL = 2 WT DQ D1 PRE D2 D3 D4 D5 ACT Hi-Z tRP CL = 3 WT DQ D1 PRE D2 D3 D4 D5 ACT Hi-Z Note: D5 data will not be written 18/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 Read Burst Stop Command BL = 2, 4, 8, Full 0 1 2 3 4 5 6 7 8 CLK RD BST CL = 2 DQ Q1 CL = 3 DQ Q2 Q3 Q4 Q1 Q2 Q3 Hi-Z Hi-Z Q4 Write Burst Stop Command BL = 2, 4, 8, Full 0 1 2 3 4 5 6 7 8 CLK WT CL = 2, 3 DQ D1 BST D2 D3 D4 Hi-Z 19/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 AUTO PRECHARGE Read with Auto Precharge BL = 4 0 1 2 3 4 5 6 7 8 CLK RAP CL = 2 Auto precharge starts Q1 DQ RAP CL = 3 Q2 Q3 Hi-Z Q4 Auto precharge starts Q1 DQ Q2 Q3 Hi-Z Q4 (tRAS is satisfied) Write with Auto Precharge BL = 4 0 1 2 3 4 5 6 7 8 CLK CL = 2 DQ CL = 3 DQ WAP D1 Auto precharge starts D2 D3 Hi-Z Auto precharge starts WAP D1 D4 D2 D3 D4 Hi-Z (tRAS is satisfied) 20/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 ELECTRICAL CHARACTERISTICS Absolute Maximum Ratings Parameter Symbol Voltage on Power Supply Pin Relative to GND Rating Unit VCC –0.5 to 4.6 V VIN, VOUT –0.5 to VCC + 0.5 ≤ 4.6 V Short Circuit Output Current IOS 50 mA Power Dissipation PD* 1 W Operating Temperature Topr 0 to 70 °C Storage Temperature Tstg –55 to 150 °C Voltage on Input Pin Relative to GND *: Ta = 25 °C Recommended Operating Conditions (Ta = 0 to 70°C) Parameter Power Supply Voltage Symbol Min. Typ. Max. Unit VCC 3.0 3.3 3.6 V VSS 0 0 0 V Input High Voltage VIH 2.0 — VCC + 0.3 V Input Low Voltage VIL –0.3 — 0.8 V Capacitance (VCC = 3.3 V ±0.3 V, Ta = 25°C, f = 1 MHz) Symbol Min. Max. Unit Input Capacitance (A0 – A10, BA0, BA1) Parameter CIN1 — 5 pF Input Capacitance (CLK, CKE, CS, RAS, CAS, WE DQM 0 – DQM3) CIN2 — 5 pF Output Capacitance (DQ0 – DQ31) COUT — 6 pF 21/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 DC Characteristics Parameter Symbol Test Condition MS82V48540-7 MS82V48540-8 CKE Other Min. Max. Min. Max. 2.4 — 2.4 — Output High Voltage VOH — IOH= –2.0 mA Output Low Voltage Unit V VOL — IOL= 2.0 mA — 0.4 — 0.4 V Input Leakage Current ILI — — –10 10 –10 10 µA Output Leakage Current ILO — — –10 10 –10 10 µA Operating Current (1 Bank) ICC1 tCK = tCK min. CKE ≥ VIH tRC = tRC min. No Burst — 200 — 180 mA ICC2P CKE ≤ VIL tCK = tCK min. — 2 — 2 mA ICC2PS CKE ≤ VIL CLK ≤ VIL tCK = ∞ — 2 — 2 mA ICC2N CKE ≥ VIH CS ≥ VIH tCK = tCK min. — 40 — 40 mA CLK ≤ VIL tCK = ∞ — 20 — 20 mA Precharge Standby Current in Power Down Mode Precharge Standby Current in Non Power Down Mode Active Standby Current in Power Down Mode Active Standby Current in Non Power Down Mode ICC2NS CKE ≥ VIH ICC3P CKE ≤ VIL tCK = tCK min. — 3 — 3 mA — 3 — 3 mA ICC3PS CKE ≤ VIL CLK ≤ VIL tCK = ∞ ICC3N CKE ≥ VIH CS ≥ VIH tCK = tCK min. — 50 — 50 mA CLK ≤ VIL tCK = ∞ — 30 — 30 mA ICC3NS CKE ≥ VIH Operating Current (Burst Mode) ICC4 CKE ≥ VIH tCK = tCK min. — 240 — 200 mA Refresh Current ICC5 CKE ≥ VIH tRC ≥ tRC min. — 200 — 180 mA Self Refresh Current ICC6 CKE ≤ 0.2V — 3 — 3 mA — Note 1, 2 1, 2 Notes 1. The maximum value of power supply current is obtained with the output open. 2. Address and data are changed only one time during one cycle. 22/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 AC Characteristics Test conditions • AC measurements assume tT = 1 ns. • Reference level for measuring timing of input signals is 1.4 V. Transition times are measured between VIH and VIL. • If tT is longer than 1 ns, reference level for measuring timing of input signals is VIH (MIN.) and VIL (MAX). • An access time is measured at 1.4 V. • Input levels at the AC testing are 2.4 V/0.4 V. tCK tCH tCL 2.4 V CLK 1.4 V 0.4 V tSetup tHold 2.4 V Input 1.4 V 0.4 V tAC tOH Output 1.4 V 1.4 V 23/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 Synchronous Characteristics Parameter Clock Cycle Time Access Time from CLK Symbol MS82V48540-7 MS82V48540-8 Min. Max. Min. Max. Unit Note CAS Latency = 3 tCK3 7 — 8 — CAS Latency = 2 tCK2 12 — 12 — ns CAS Latency = 3 tAC3 — 5 — 6 ns 1 CAS Latency = 2 tAC2 — 8 — 8 ns 1 ns CLK High Level Width tCH 2.5 — 3 — ns CLK Low Level Width tCL 2.5 — 3 — ns Data-out Hold Time tOH 2 — 2 — ns Data-out Low-impedance Time tLZ 0 — 0 — ns Data-out High-impedance Time tHZ — 5 — 6 ns Data-in Setup Time tDS 2 — 2 — ns Data-in Hold Time tDH 1 — 1 — ns Address Setup Time tAS 2 — 2 — ns Address Hold Time tAH 1 — 1 — ns CKE Setup Time tCKS 2 — 2 — ns CKE Hold Time tCKH 1 — 1 — ns Command (CS, RAS, CAS, WE, DQM) Setup Time tCMS 2 — 2 — ns Command (CS, RAS, CAS, WE, DQM) Hold Time tCMH 1 — 1 — ns Note 1. Output load. 1.4 V Z = 50Ω 50Ω Output 30 pF 24/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 Asynchronous Characteristics Parameter MS82V48540-7 MS82V48540-8 Min. Max. Min. Max. tRC 63 — 72 — ACT to PRE Command Period tRAS 42 120k 48 120k ns SACT to PRE Command Period tRASS 6 — 6 — CLK tRP 21 — 24 — ns REF to REF/ACT/SACT Command Period PRE to ACT Command Period Symbol Unit ns PRE-ALL (Special Page) to SACT Command Period tRPS 9 — 9 — CLK Delay Time ACT/SACT to READ/WRITE Command tRCD 21 — 24 — ns ACT (0) to ACT (1) Command Period tRRD 14 — 16 — ns READ/WRITE to READ/WRITE Command Period tCCD 7 — 8 — ns Data-in to PRE Command Period tDPL 7 — 8 — ns Data Output to WRITE Command Input Time tOWD 14 — 16 — ns Mode Register Set Cycle Time tRSC 14 — 16 — ns tT 1 30 1 30 ns tREF — 64 — 64 ms Transition Time Refresh Time Note 25/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 TIMING WAVEFORM READ/WRITE CYCLE (BL = 2, CL = 3) 0 CLK 1 2 tCK tCKS tCH 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 tCKH tCL CKE tCMS tCMH CS RAS CAS WE tAS tAH BA0 BA1 A10 /AP RAa ADD RAa RDa CAa tCMS DQM 0-3 DQ CAb tAC tOH Hi-Z tHZ tDS tDH DAb1 DAb2 QAa1 QAa2 tRCD RDa tCMH tLZ tOWD tDPL tRAS tRP tRC ACT-A RD-A WT-A PRE-A ACT-D 26/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 Special READ CYCLE (BL = Special Page, CL = 3) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 CLK CKE H CS RAS CAS WE BA0 BA1 A10 /AP RAa ADD RAa DQM 0-3 DQ RDa CAa RDa L Hi-Z QAa1 QAa2 QAa3 QAa4 tRCD SACT-A Qn-1 Qn Qn+1 Qn+2 tRASS SRD-A Special Read Start tRPS PRE-ALL SACT-D 27/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 Special WRITE CYCLE (BL = Special Page, CL = 3) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 CLK CKE H CS RAS CAS WE BA0 BA1 A10 /AP RAa ADD RAa DQM 0-3 DQ RBa CAa RBa L Hi-Z DAa1 DAa2 DAa3 DAa4 DAa5 tRCD SACT-A tRASS SWT-A Special Write Start Dn-2 Dn-1 Dn tDPL PRE-ALL tRPS SACT-B 28/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 Mode Register Set 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 CLK CKE H CS RAS CAS WE BA A10 /AP ADD DQM 0-3 DQ Hi-Z MRA PRE-ALL tRP ACT tRSC 29/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 Auto Reflesh 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 CLK CKE H CS RAS CAS WE BA A10 /AP ADD DQM 0-3 L DQ Hi-Z REF PRE-ALL tRP REF tRC ACT tRC 30/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 Self Reflesh (Entry and Exit) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 CLK CKE H CS RAS CAS WE BA A10 /AP ADD DQM 0-3 DQ L Hi-Z PRE-ALL tRP SELF Entry SELF Exit tRC SELF Entry SELF Exit ACT tRC 31/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 Burst Termination by Precharging (BL = 8, CL = 3) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 CLK CKE H CS RAS CAS WE BA0 BA1 A10 /AP RAa ADD RAa DQM 0-3 DQ RAb CAa RAb CAb L Hi-Z ACT-A DAa1 DAa2 WT-A QAb1 QAb2 QAb3 QAb4 PRE-A ACT-A PRE Command Termination RD-A PRE-A PRE Command Termination 32/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 Auto Precharging (BL = 4, CL = 3) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 CLK CKE H CS RAS CAS WE BA0 BA1 A10 /AP RAa RBa ADD RAa CAa RBa DQM 0-3 DQ CBa L Hi-Z ACT-A QAa1 QAa2 QAa3 QAa4 RAP-A ACT-B DBa1 DBa2 DBa3 DBa4 WAP-B AP-A AP-B 33/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 Power Down Mode and Clock Suspension (BL = 4, CL = 2) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 CLK tCKS CKE CS RAS CAS WE BA0 BA1 A10 /AP RAa ADD RAa DQM 0-3 DQ CAa L Hi-Z QAa1 QAa2 ACT-A PD Entry RD-A PD Exit ACTIVE STANDBY QAa3 QAa4 PRE-A Clock Mask Start Clock Mask End PD Entry PD Exit PRECHARGE STANDBY 34/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 CLOCK Suspend Exit & Power Down Exit 1) Clock Suspend (= Active Power Down) Exit 2) Power Down (= Precharge Power Down) Exit CLK CLK CKE CKE Note 3 Internal CLK Command tCKS Internal CLK Note 1 RD tCKS Note 2 Command NOP ACT Notes: 1. Active power down: one or both bank active state. 2. Precharge power down: both bank precharge state. 3. NOP should be issued. And new command can be issued after 1 Clock. 35/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 Byte Read/Write Operation (by DQM) (BL = 4, CL = 3) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 CLK CKE H CS RAS CAS WE BA0 BA1 A10 /AP RBa ADD RBa CBa CBb DQM0 DQM1 DQM2 DQM3 DQ 0-7 QBa1 QBa2 QBa3 DQ 8 - 15 DBb2 DBb3 DBb4 QBa2 QBa3 QBa4 DQ 16 - 23 QBa1 DQ 24 - 31 QBa1 QBa2 ACT-B RD-B QBa3 QBa4 QBa4 DBb1 DBb3 DBb4 DBb1 DBb2 DBb4 DBb1 DBb2 DBb3 WT-B Byte of Byte of Byte of Byte of DQ8-15 DQ24-31 DQ0-7 DQ16-23 not Read not Read not Write not Write Byte of Byte of Byte of Byte of DQ16-23 DQ0-7 DQ8-15 DQ24-31 not Read not Read not Write not Write 36/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 Burst Read and Single Write (BL = 4, CL = 3) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 CLK CKE H CS RAS CAS WE BA0 BA1 A10 /AP RAa ADD RAa DQM 0-3 L DQ Hi-Z ACT-B CAa QAa1 QAa2 QAa3 QAa4 RD-B CBb CBb DBb DBc Single WT-B Single WT-B PRE-B 37/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 Random Column Read (Continuous Read of Same Bank) (BL = 4, CL = 3) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 CLK CKE H CS RAS CAS WE BA0 BA1 A10 /AP RAa ADD RAa DQM 0-3 RAi CAa CAb CAc RAi L DQ QAa1 QAa2 QAa3 QAa4 QAb1 QAb2 QAc1 QAc2 QAc3 QAc4 ACT-A RD-A RD-A RD-A PRE-A ACT-A 38/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 Random Column Write (Continuous Write of Same Bank) (BL = 4, CL = 3) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 CLK CKE H CS RAS CAS WE BA0 BA1 A10 /AP RBa ADD RBa DQM 0-3 RBi CBa CBb CBc RBi L DQ DBa1 DBa2 DBa3 DBa4 DBb1 DBb2 DBc1 DBc2 DBc3 DBc4 ACT-B WT-B WT-B WT-B PRE-B ACT-B 39/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 Interleaved Column Read (BL = 4, CL = 3) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 CLK CKE H CS RAS CAS WE BA0 BA1 A10 /AP RAa RBa ADD RAa CAa RBa DQM 0-3 CBa CBb CAb L DQ QAa1 QAa2 QAa3 QAa4 QBa1 QBa2 QBb1 QBc2 QAb1 QAb2 QAb3 QAb4 ACT-A RD-A ACT-B RD-B RD-B RD-A PRE-B PRE-A tRCD tRRD 40/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 Interleaved Column Write (BL = 4, CL = 3) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 CLK CKE H CS RAS CAS WE BA0 BA1 A10 /AP RCa RDa ADD RCa CCa RDa DQM 0-3 CDa CDb CCb L DQ DCa1 DCa2 DCa3 DCa4 DDa1 DDa2 DDb1 DDb2 DCb1 DCb2 DCb3 DCb4 ACT-C WT-C ACT-D WT-D WT-D WT-C PRE-D PRE-C tRCD tRRD 41/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 PACKAGE DIMENSIONS (Unit: mm) TSOP(2)86-P-400-0.50-K Mirror finish 5 Package material Lead frame material Pin treatment Package weight (g) Rev. No./Last Revised Epoxy resin 42 alloy Solder plating (≥5µm) 0.53 TYP. 1/Jul. 14, 1998 Notes for Mounting the Surface Mount Type Package The surface mount type packages are very susceptible to heat in reflow mounting and humidity absorbed in storage. Therefore, before you perform reflow mounting, contact Oki’s responsible sales person for the product name, package name, pin number, package code and desired mounting conditions (reflow method, temperature and times). 42/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 REVISION HISTORY Document No. Date Page Previous Current Edition Edition – – Description First edition Changed the speed rank indication in “Package” of the FEATURES Section from “XX to “x”. 1 1 Changed the device names in the Family column in the table of the PRODUCT FAMILY Section. FEDS82V48540-01 22 22 Changed the names of the family devices in the table of the DC Characteristics Section. 24 24 Changed the names of the family devices in the table of the Synchronous Characteristics Section. 25 Changed the names of the family devices in the table of the Asynchronous Characteristics Section. Nov. 8, 2002 25 43/44 FEDS82V48540-01 OKI Semiconductor MS82V48540 NOTICE 1. The information contained herein can change without notice owing to product and/or technical improvements. Before using the product, please make sure that the information being referred to is up-to-date. 2. The outline of action and examples for application circuits described herein have been chosen as an explanation for the standard action and performance of the product. When planning to use the product, please ensure that the external conditions are reflected in the actual circuit, assembly, and program designs. 3. When designing your product, please use our product below the specified maximum ratings and within the specified operating ranges including, but not limited to, operating voltage, power dissipation, and operating temperature. 4. Oki assumes no responsibility or liability whatsoever for any failure or unusual or unexpected operation resulting from misuse, neglect, improper installation, repair, alteration or accident, improper handling, or unusual physical or electrical stress including, but not limited to, exposure to parameters beyond the specified maximum ratings or operation outside the specified operating range. 5. Neither indemnity against nor license of a third party’s industrial and intellectual property right, etc. is granted by us in connection with the use of the product and/or the information and drawings contained herein. No responsibility is assumed by us for any infringement of a third party’s right which may result from the use thereof. 6. The products listed in this document are intended for use in general electronics equipment for commercial applications (e.g., office automation, communication equipment, measurement equipment, consumer electronics, etc.). These products are not authorized for use in any system or application that requires special or enhanced quality and reliability characteristics nor in any system or application where the failure of such system or application may result in the loss or damage of property, or death or injury to humans. Such applications include, but are not limited to, traffic and automotive equipment, safety devices, aerospace equipment, nuclear power control, medical equipment, and life-support systems. 7. Certain products in this document may need government approval before they can be exported to particular countries. The purchaser assumes the responsibility of determining the legality of export of these products and will take appropriate and necessary steps at their own expense for these. 8. No part of the contents contained herein may be reprinted or reproduced without our prior permission. Copyright 2002 Oki Electric Industry Co., Ltd. 44/44