ALLEN-BRADLEY MSR127RP

Safety Relays
Monitoring Safety Relays
Minotaur MSR127RP/TP
Specifications
Description
Standards
EN954-1, ISO13849-1, IEC/
EN60204-1, IEC60947-4-1,
IEC60947-5-1, ANSI B11.19,
AS4024.1
Category
Cat. 4 per EN 954-1 (ISO 13849-1)
Approvals
CE marked for all applicable
directives, cULus and BG
Power Supply
24V AC/DC, 115V AC or 230V AC
0.8 to 1.1 x rated voltage, 50/60Hz
Power Consumption
2W
Safety Inputs
1 N.C. or 2 N.C. or 2 PNP (light
curtain)
Input Simultaneity
Infinite
Max. Allowable Input Resistance
110 ohms
Reset
Monitored Manual or Auto./Manual
The MSR127RTP can be connected in three different input wiring
configurations: 1 N.C., 2 N.C., or with 2 PNP connections from a
light curtain. When connected in the 2 N.C. fashion, the
MSR127RTP checks for cross faults across the two inputs. When
connected to light curtains, the light curtain must perform the cross
fault detection.
Outputs
3 N.O. Safety; 1 N.C. Auxiliary
Output Utilization per IEC
60947-4-1 (Resistive)
AC-1: 5A/250V AC
DC-1: 5A/24V DC
➊ Output Utilization per IEC
60947-5-1 (Inductive)
B300, AC-15; 5A/250V AC,
5A/125V AC
P300, DC-13; 3A/24V DC
5A/24V DC @ 6 ops/min
The MSR127RP has a monitored manual reset. The MSR127TP has
an automatic/manual reset. Models with automatic/manual reset
can have the reset jumpered or can be converted to an unmonitored
manual reset by adding a normally open switch in the monitoring
loop. Models with monitored manual reset provide checking of the
output monitoring circuit.
Thermal Current (non switching)
Units with 24V AC/DC supply:
Units with 115/230V AC supply:
3x4A or 2x5A
3x3A or 2x4A or 1x5A
Fuses Output (external)
6A Slow Blow or 10A Quick Blow
The outputs include 3 normally open safety rated outputs as well as
1 normally closed auxiliary output. The safety outputs have
independent and redundant internal contacts to help ensure the
safety function. The auxiliary output is a nonsafety output intended
to provide an external signal about the status of the safety outputs.
Min. Switched Current/Voltage
10mA/10V
Contact Material
AgSnO2 + 0.5mAu
Power On Delay
1s
Response Time
15ms
Recovery Time
100ms
Indication LEDs
Green = Power
Green = CH1 Closed
Green = CH2 Closed
Features
•
•
•
•
•
•
•
•
Category 4 per EN 954-1
Stop category 0
3 Safety contacts
1 Auxiliary contact
Cross fault monitoring
Monitored or automatic reset
Removable terminals
Light curtain, E-Stop or safety gate applications
Impulse Withstand Voltage
2500V
Pollution Degree
2
Operating Temperature
-5°C to +55°C (+23°F to 131°F)
Humidity
90% RH
Enclosure Protection
IP40 (NEMA 1)
Terminal Protection
IP20
Maximum Conductor Size
0.2 to 4mm2 (24-12AWG)
Torque Settings—term. screws
0.4Nm (3.54lb•in)
Case Material
Polyamide PA 6.6
Mounting
35mm DIN rail
Weight 24V DC
110V AC or 230V AC
210g (0.463lbs)
260g (0.573lbs)
Electrical Life (w/Surge Supp.)
250V AC/6A/1500VA cosϕ=1
250V AC/2.5A/625VA cosϕ=1
250V AC/1.5A/375VA cosϕ=0.35
250V AC/5A/1250VA cosϕ=0.6
24V DC/2A/48W
10V DC/0.01A/0.1W
100,000 operations
500,000 operations
300,000 operations
100,000 operations
1,000,000 operations
2,000,000 operations
Mechanical Life
2,000,000 operations
Vibration
10-55Hz, 0.35mm
Shock
10g, 16ms, 100 shocks
➊ See Output Ratings on page 1-29 for details. Consult factory for ratings not
shown.
4-38
Safety Relays
Monitoring Safety Relays
Minotaur MSR127RP/TP
Product Selection
Inputs
Safety Outputs
Auxiliary Outputs
Terminal
s
Type
Reset
Catalogue
Number
MSR127T
Automatic/Manual
440R-N23126
MSR127R
Monitored Manual
440R-N23129
MSR127T
Automatic/Manual
440R-N23125
MSR127R
Monitored Manual
440R-N23128
MSR127T
Automatic/Manual
440R-N23124
MSR127R
Monitored Manual
440R-N23127
MSR127TP
Automatic/Manual
440R-N23132
MSR127RP
Monitored Manual
440R-N23135
MSR127TP
Automatic/Manual
440R-N23131
MSR127RP
Monitored Manual
440R-N23134
MSR127TP
Automatic/Manual
440R-N23130
MSR127RP
Monitored Manual
440R-N23133
Power Supply
24V AC/DC
Fixed
115V AC
230V AC
1NC,
2NC, or
Light Curtain
3 N.O.
1 N.C.
24V AC/DC
Removable
115V AC
230V AC
Dimensions—mm (inches) Block Diagram
22.5 (0.88)
99 (3.89)
13
A1
S12
23
S11(+)
K1
114.5
(4.5)
33
41
S52
S12
13 23 33 41
S52
S21
K2
14 24 34 42
S22
S22
24
S21(-)
14
S34
34
A2
42
Typical Wiring Diagrams
L1
L1
Reset
Light curtain, 24V DC
Out1 Out2
L1 L2 L3
A1
S11
S52
S12
23
13
33
E-Stop
41
L1 L2 L3
A1
S11
S52
S12
13
23
33
41
K1
K1
MSR127TP
MSR127RP
K2
S21
S22
S34
A2
34
14
24
K1
K2
42
S21
S22
S34
A2
M
14
24
34
42
M
K1
N
N
Light Curtain, Monitored Manual Reset,
Monitored Output
Single Channel E-Stop, Automatic Reset,
No Output Monitoring
L1
L1
Reset
L1 L2 L3
E-Stop
A1
S11
S52
S12
13
23
33
L1 L2 L3
open
41
A1
S11
S52
S12
13
23
33
41
K1
K1
MSR127RP
MSR127RP
K2
S21
S22
S34
A2
14
24
K1
K2
34
K2
42
N
M
S21
closed
S22
S34
A2
14
24
K1
K2
34
42
M
N
Dual Channel E-Stop, Monitored
Manual Reset, Monitored Output
Dual Channel Safety Gates,
Automatic Reset, Monitored Output
4-39